I noticed on my new cisco 2960s switches, that all the lights went orange for about 10 seconds then went off again, this was during normal operation, all ports were shutdown at the time apart from a few,the ones that were enabled, the led's went off.
I am looking to simply monitor Port-Security , Error-Disable and HSRP. I would like to receive an email when any of these are triggered.
Port Security - Port Is shut down Err-Disable - Port goes into err-disable state (securedown) HSRP - When HSRP standyby changes are detected
I need to receive emails with any of the able are triggered. What is the easiest way to do this? I know SNMP is the main option but I have never worked with SNMP and dont understand it too much.
I have a Cisco SG 300-20 as the core switch, layer 3. It is 192.168.4.6 on VLAN1 and 192.168.5.1 for VLAN2 (VOIP). All the ports are set in trunk mode. DHCP relay is setup on this switch.
The phones connected into a layer 2, Catalyst 2960-S switch. All ports are set in trunk mode. Default gateway on it is set to 192.168.5.1.
DHCP for both VLANs is provided by a Windows Server 2008 R2 server (the relay IP 192.168.4.15).
There is also an ASA 5510 in the mix which is 192.168.4.1. It has a route added to it for the 192.168.5.0 network to go to the SG 300 (192.168.5.1).
Just the two switches can ping each other on the 192.168.5.x network when I "add vlan 2" to the trunk port that is connected between the SG 300 and the 2960. The phones don't get DHCP on the 2960 switch. And I cannot ping 192.168.5.x from the ASA or anything else on the 192.168.4.x network.
After a bit of reading on intra-vlan routing for the SG 300 switch, I am thinking the SG 300 has to be the "center" of things so I need to make it 192.168.4.1 to be the gateway for both VLANs and change the ASA to 192.168.4.2 for VLAN1, etc. And I really can't do asymmetric routing with this switch.
I have a statck of 4 2960s switches, with POE powered access points on 2 of them. All of the access points appear to be functioning normally. For some reason, on 3 interfaces connected to access points, I get the following when issuing show interfaces status:
Gi3/0/9 connected: T 7 a-full a-1000 10/100/1000BaseTX ^
My question is regarding the "T" in the status field. I can't find any documentation on this.
I am trying to configure a new 2960 POE switch, but seem to me the int fa0 is layer 3 interface. Is any way we can convert it to a switchport, so we can connect it to other switch in trunk mode?
i try to implement layer 2 qos in 2960. when i complete to configure the switch, i want to test the qos.PC1 conect to switch port 1,PC2 conect to switch port 2 . PC1 is source teminal. i use skydata.exe and FTP for the test.
when use the skydata ,the PC2 speed can reach 10mbps.when use the FTP , the PC2 only can reach 1.2mbps. why?
I can use Putty to SSH into my new switch (Directly connected to my laptop with ethernet cable), but I cant log into my switch.
Sent username "admin" admin@192.168.251.1's password: Access denied
It doesnt like my password, but I have only set 1 password (king) on this switch. I've configured 3 other switches with SSH and had no problem. Been trouble shooting for awhile and It'd be great if I could have a 2nd set of eyes take a peek, Also, my running config is attached.
I am setting up a new 2960-S switch and none of the recommended username and passwords combinations work. I have tried CIsco Cisco, <blank> cisco and various other permutations.
I have tried to reset the switch to factory defaults and it still doesn't work. The switch is currently connected to a 3560G and has been assigned an IP. If I try to access it from Network assistant it shows as unmanaged and I get prompted for a username and password.The switch is connected to another new 2960-S via a FlowStack module.
I need to know the 172cisco 1 router support to IPv6 & it support to IPv6 then which IOS is required for it.Also I need to know the cisco 2960 switch is support to IPv6?
I am a new network engineer on a retail company and I am having a problem on the High utilization of my 3-stack switch 2960 only during Peak Hours of the Store Sales.
Note: on Peak hours, it is peaking at 90-95 % here is the utilization after Peak hours: 4444333334444433333333333333333333333333333333333333333333
I can understand it 's one of those very basic questions , but how do I identify a Switch is Layer 2 or Layer 3 ?Looking through # show version command and checking the IOS version to be IP BASE or LAN BASE . Is it the right way ?Cisco 2960 is a Layer 2 or a Layer 3 Switch ? I noticed that access-lists could be configured which means that it 's a Layer 3 Switch , right?
I have a Cisco 1841 router connected to a Cisco 2960 switch.Users behind the router can't access the internet but when someone is directly connected to the switch with his PC and uses the IP Address found on the WAN port of the router, he's able to go on to the internet. [code]
Today in my rush to get home I plugged in a new 2960 stack and did a little bit of very basic configuration, but no passwords were set. I tried to telnet in and the message says that a password is required, but none is set. I tried the SDM as I hadn't turned it off yet and it is prompting me for a user/pass but I have no idea what to put in there. No console is available, it's a new office so no employees around either.
i am facing time daely issues on cisco 2960 s series switch while booting .It is taking time for electing masrer and sleeve for stacking.can i disable the election process for stcking while booting.
Configuration details: I have 2 nexus 5K switches and both 5K is connected to four 2960 access switches in each floor through fiber(shown in the attached picture). I have configured each VPC for each floor and portchannel configuration on 2960s switch to communicate to 5K switches. Now I am not able to communicate PC 1 connected in 1st floor to PC2 connected in 4th Floor.
I have attached topology map of my infra and the configuration files also. 1st floor switch and 4th floor swich have same configuration except IP address and switch name.
Document at url... is quite interesting,One of these goes about the behavior of a switch (2960-S and 3750G) when QoS is not enabled vs the one when QoS is simply enabled with "mls qos".What additional commands, beside "mls qos", would be needed so as to simulate as accurately as possible the switch's behavior when QoS is not enabled?
I have a client whom has asked me to enable web management on some of his 2960 switches. I did not think this was going to be an issue, and so I told the customer I would set this up for him.
Much to my dismay, I have been able to get http and https enabled, and then authenticating locally for the HTTP access. I then come to the screen once authenticated which is shown below:
The issue is that when I select "Web Console", it gives me a "Web Page Cannot be found".
I have a Cisco 2960-S Switch, It is connected to a jack in the building to check the settings, Interface VLAN 1 has an ip, there is a default gateway, Any host connected to switch can access the network resources. But the problem is that I have to use Serial Cable to configure it. I cant ping or telnet into it from any other device. PC's are on different subnets/VLANS.
Basically this switch is connected to a port in a different switch, Do i have to make a trunk?
I have a 2960 that bounced several times over the weekend and then appears to have lost its configuration. Using CDP from the backbone switch pulls up the information below. Is there any way for me to configure the downed switch from another switch on the network? I am trying to avoid having someone from the site try to find a console cable and a suitable computer with a serial port. [code]
I am trying to upgrade my cisco WS 2960 24 TC-L switch with the IOS image c2960-lanbasek9-mz.122-55.SE6.bin and my existing IOS image is c2960-lanbasek9-mz.122-50.SE5.bin. when i am copying it to flash, it is getting copied but when i tried to boot it after entering command boot system c2960-lanbasek9-mz.122-55.SE6.bin , it gave me an error.
I have a 2960 switch and every then and now the ports are flapping, while i was on console i saw ports going down and coming up...when the ping to machine ip addresses timed out the port status on switch was still up...no errors collisions seen on sw port. Below is sh int when the port was flapping
I am working on Multicast scenario, There is one 6513E switch one 2960 switch. Two VRF's are configured in core switch (6513) IPTV-SRV and Villa-VRF IPTV-SRV vrf has IPTV server and Villa-VRF has IPTV i.e. client.
V LAN 30 is mapped to IPTV-SRV vrf with subnet address 192.168.30.0/24 V LAN 12 is mapped to Villa-VRF with sub net address 192.168.12.0/24
I did the following configuration for VRF but its not working . i am not an expert in multicast design but seems i did most of the configs.