Cisco Switching/Routing :: Error In Logging Observed On 6513 Switch
Jul 15, 2012
I have been getting the logs in my cisco 6513 switch [code] On further investigating in the module 9 which has a DFC card also , we found the source of this error whether it is a source of any upcoming potential impact or can be simply ignored
View 3 Replies
ADVERTISEMENT
Jan 18, 2012
Ask this question, if someone came across a 6513, one of the RJ45 ports are constantly falling.The question is how to disable logging on a specific portno logging event link-status does not work.
View 1 Replies
View Related
Dec 8, 2012
I have a Cisco catalyst 6513 with sup720-3bxl and WS-X6724-SFP modules , the switch was working fine until yesterday ,but after a maintenance the modue WS-X6724-SFP failed to bring online , the error code is (Module Failed SCP dnld) does it mean the module has hardware problem or i need to replace it ?
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
ios version
s72033-adventerprisek9_wan-vz.122-33.SXH7.bin
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
show module
Mod Ports Card Type
Model
[code]....
View 3 Replies
View Related
Apr 28, 2012
We have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".
View 4 Replies
View Related
Mar 20, 2013
Need your expert input in sorting out the below problem.I have a cisco 6513 switch which is going into SP mode after a reboot whci i have done during BCP activity in my organization.Below are the log for your reference.
Code...
View 1 Replies
View Related
May 9, 2012
i have a Cisco 6513 it is used one, i have tryed to boot it but it did not work, it alwayes go to rommon mode and i am not able to know what is the issue,
when it boot i get the below outpot from the switch.
System Bootstrap, Version 8.1(3)
Copyright (c) 1994-2004 by cisco Systems, Inc.
Testing lower main memory - data equals address
[Code].....
View 3 Replies
View Related
Sep 3, 2012
I am working on Multicast scenario, There is one 6513E switch one 2960 switch. Two VRF's are configured in core switch (6513) IPTV-SRV and Villa-VRF IPTV-SRV vrf has IPTV server and Villa-VRF has IPTV i.e. client.
V LAN 30 is mapped to IPTV-SRV vrf with subnet address 192.168.30.0/24
V LAN 12 is mapped to Villa-VRF with sub net address 192.168.12.0/24
I did the following configuration for VRF but its not working . i am not an expert in multicast design but seems i did most of the configs.
ip vrf IPTV-SRV
rd 30:1
mdt default 232.1.1.1
route-target export 30:1
route-target import 10:1
[code]...
View 3 Replies
View Related
Mar 2, 2012
I have two servers, connected on two(Different) 6513 directly connected switches. Both these servers are in the same Vlan.
I have to monitor communication these two servers. I have a system connected on one of the 6513 switch, where network tool wireshark is installed.
How to configure span port.
switch 6513-1# show run int Gi10/43 --------------------Server 1 is connected
switch 6513-2# show run int Gi9/45 ------------------------Server 2 is connected
switch 6513-2# show run int Gi9/46 ------------------------System on which network tool wireshark is installed.
View 9 Replies
View Related
Apr 7, 2012
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command:
Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
View 6 Replies
View Related
Jun 18, 2012
I have a supervisor blade, (VS-S720-10G-3C), in a 6513 that is faulty and needs replaced. Do I need to replace the IOS on the new supervisor blade to make sure it is the same as the IOS image that is on the Active supervisor module, or will it synchronize automatically?
In the synchronization process, the active supervisor engine checks the standby supervisor engine run-time image to make sure that it matches its own run-time image. The active supervisor engine checks three conditions:
#
•If it needs to copy its boot image to the standby supervisor engine
#
•If the standby supervisor engine bootstring needs to be changed
#
•If the standby supervisor engine needs to be reset
I was reading the above documentation that mentioned the active supervisor should copy the image if it detects a newly installed standby supervisor blade with a different image, is this correct or was it referring to synchronizing the configuration file?
View 3 Replies
View Related
Oct 29, 2012
we have a chassis 6513-E and a module WS-X6748-GE-TX, I'd like to know if could I put this module in any slot, since the documentation from Cisco says that any slot from a chassis 6500-E Series can support this module. And then in the documentation of WS-X6748-GE-TX says that this module is not compatible in the slots 1-8 of the 6513 chassis, only from 9th to 13th slots, in those slots from the 6513-E we already have 4x WS-X6748-GE-TX, and we'd like to know if could we put the module in the rest of the slots. The 6513, and 6513-E is kind of confusing.
View 4 Replies
View Related
Mar 7, 2012
I just added a X6704 card to our 6513 switch, and it is not working correctly. We are running 12.2(33)SXI5. [code]
View 5 Replies
View Related
Feb 20, 2012
How much is the limit for the creation of PortChanel in a Core Switch 6509 and 6513?Is there a limitation byu hardware?
View 7 Replies
View Related
Apr 23, 2012
We had a core switch(4503) in our environment and recently we tried to enable syslog in the switch. But the syslog server doesnt receives all the configured level messages from the switch. Following is the only message getting in syslog server after the configuration change in switch.
%SYS-5-CONFIG_I: Configured from console by CWLMS onvty1
(No Traffic related messages like acl deny traffic, spanning tree events etc are getting to syslog server as well as log buffer of the switch)
Following are the logging configuration for the core switch
logging monitor informational
logging facility syslog
logging source-interface Vlan44
[Code]....
1) Is there any more configurations required for getting all traffic related messages, (i mean all possible messages - upto level 7 - debugging)?
View 3 Replies
View Related
Mar 13, 2013
My cisco 4948 switch is generating the below error,how do i troubleshoot this error.
*Mar 13 00:09:33.451: %C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET: (Suppressed 14 times)Packet received with invalid source MAC addre ss (00:00:00:00:00:00) on port Gi1/37 in vlan 1Gi1/37- to this port another 2950 switch is connected by trunk link.and to this switch end host is connected i.e.thin client
View 3 Replies
View Related
Nov 8, 2011
I have a 4507 cisco switch loaded with two sup-modules.. [code]
View 5 Replies
View Related
Sep 4, 2012
i have a problem with a cisco cat. 4507 edge switch as when i have a login ssh session to the switch the supervisor engine restart and the redundant Sup. engine becomes the active and so on this problem mainly happen when i have multible SSH session to the switch and it happened very rarely with a single ssh login
the ios version i use is cat4500-entservicesk9-mz.122-54.SG which im using on all my edge switch and they are all working fine excpt this one
View 1 Replies
View Related
Feb 22, 2013
I have a switch connect to 2 backbone(BB).
Now i saw the lights when connect to BB1 is not light but i do not know which command will show the root cause or troubleshooting.
I want to know its caused by hardware, physical port or whatever. Any on can sharing the experiences how to show and troubleshooting this issue?
I also checked the connection and port 1g is fine. Show tech-support is alread here.
View 10 Replies
View Related
Nov 21, 2012
We are getting some error logs on Nexus VDC,as follows:2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times 2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times 2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times.
View 1 Replies
View Related
Dec 3, 2011
power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW PID,Serial# Status Sys Pwr PoE Pwr Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?
View 3 Replies
View Related
Feb 18, 2013
We are using Cisco Router 1841 and users reporting issue related to VoIP. After investigation, seeing input errors on Router LAN interface, but there is no error on connected switch interface. [code]
View 2 Replies
View Related
Oct 17, 2012
We have network topo ( attach file)Two switch run VRRP, if I ping 10.0.10.3 from switch SW-6504-01 with source 10.0.10.2, ping lost one packet every 10 packets.We have other interface vlan with same problem
this is some config:
!
interface Port-channel1
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
no ip address
!
interface GigabitEthernet3/47
[code]....
View 5 Replies
View Related
Feb 13, 2012
As always, the Cisco LMS is keep sending the follwoing high discard error from the Cisco switches WS-C2950T-24:
EVENT ID = 0004SX3
ALERT ID = 00019LF
TIME = Tue 14-Feb-2012 08:56:35 GMT
[Code].....
View 4 Replies
View Related
Apr 29, 2013
I am trying to copy IOS from my TFTP server which is on my laptop to cisco 2960 switch
I am able to ping to switch from my laptop, connectivity is fine, tftp server is running
Current Image on Switch --> C2960-LANBASE-MZ.122-25.SEE3.bin --> trying to upgrade to --> c2960-lanbasek9-mz.122-53.SE2
I am getting below error when trying to upgarde IOS:
2960-SW#copy tftp: flash:
Address or name of remote host []? 10.1.x.x
Source filename []? c2960-lanbasek9-mz.122-53.SE2
[Code].....
View 6 Replies
View Related
Oct 29, 2012
We are getting some error logs on Nexus switch 7K.
Loggs:
----------
2012 Oct 30 22:36:07 SWITCH %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 6) is now UP
2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service "ipqosmgr" on active supervisor failed to sto
re its snapshot (error-id 0x40480005).
2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up.
2012 Oct 30 22:36:42 SWITCH %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAF1550ATBR)
2012 Oct 30 22:42:08 SWITCH %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting
[code]....
View 8 Replies
View Related
Dec 28, 2011
when I want to recover my 2960 switch in rommon mode with xmodem command, It shows me these errors. when I reset the switch, still shoes these errors:
Unknown cmd: 1;2c1;2c[?1;21;2c[?1;21;2c[?1;2;21;2c[?1;2[
switch: ?1;2c[?1;21;2c[?1;21;2c
switch: ccknown cmd:
*** line too large *****tch: c1;2[?1
switch:
Unknown cmd: cc?1;2c[?1;21;2c[
[code]....
View 1 Replies
View Related
Apr 6, 2013
we have two 6509E which are configured in VSS mode with the following modules in each:
1 48 CEF720 48 port 10/100/1000mb Ethernet
2 8 DCEF2T 8 port 10GE
3 4 CEF720 4 port 10-Gigabit Ethernet
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G
I need to know if the temperature of the attached modules are normal or there is a problem?
the status of one of the supervisor engines is "MajFail" as shown below:
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Major Error
View 3 Replies
View Related
Jul 9, 2012
I've Nexus 7010 switch installed in my DC. I've conncected Cisco router to one of the Ports. On the same port I'm getting following error message and hence, unable to form EIGRP neighborship.
DR-CORE-SW-S01-NEXUS7K %MODULE-2-MOD_SOMEPORTS_FAILED:
Module 1 (serial: JAF*******NGK) reported failure on ports 1/2-1/2 (Ethernet) due
to R2D2 : Speed patch failed - no frames transmitted in device 143 (error 0xc8f0
1273)
View 1 Replies
View Related
Jan 31, 2012
Well I have been back and forth on this a while now...I have a 6513E chassis that is getting prepped for prod. I am currently testing sso functionality and I can only get it to work using the following images on both Sup Cards.
s72033-adventerprise_wan-mz.122-33.SXI5.bin
If I try any other image, smaller or bigger in size...it forces my Sup card in mod 8 to recycle " proxy request from peer ". I have tried K9 images and non K9 images. Here is an output from sh redundancy.
Redundant System Information : Available system up time = 4 minutes Switch overs system experienced = 0 Standby failures = 0 Last switchover reason = none [code]...
View 2 Replies
View Related
Jul 31, 2012
I have a new 6513 with 2 sup32's with IOS. This chassis will replace a working 6513 with 2 sup2's with CatOS.I need to pull the running config from the CatOS chassis and make it work on the IOS chassis. i can do this manually but was wondering if there are any trade secrets on doing this.
View 3 Replies
View Related
Nov 21, 2011
I am replacing a faulty sup720 on a 6513. It s the backup/hot not the active sup. It has the same IOS on it. Is it correct that all I need to do is remove the faulty and replace it with the new sup and do a wr mem? Fromwat I have read their should be no down time all connectivity should remain stable?
View 6 Replies
View Related
Aug 9, 2012
I have a 6513 with redundant sup 720-3B's that I cannot get onto. In short, one of the power supplies failed, it still passes traffic but I can't console or ssh to the box. Other than the two sup 720's, I have a 4 port 10gig card, a 16 port GBIC Card and an IDS module. I have tried removing the 10Gig, IDS and one of the sup's but still don't get anything on the console. I have rebooted the entire chassis and don't get anything on my console while booting. I have tried changing the speed of my terminal to every setting available incase someone has changed it at some stage but to no avail. I have tried swapping sup's, using only one at a time in the chassis but not getting anything. Is there anything else I can try to get onto this chassis? The power supply is a 3000w with a 32amp input. The failed power supply had tripped a switch, when i brought it back up, the power supply came out but the output failed LED is on. My #questions are, is there anything else I can do to try get onto the console, and is the power supply goosed when the RED LED is lit? I have reseated the power supply also but the same result.
View 2 Replies
View Related
Apr 18, 2013
Are there any EOL notices out for the Catalyst 6513, 6509 etc E chassis? I cant find anything on the internet for the E variant, so assume this hasn't had a notice published yet.
View 2 Replies