Cisco Switching/Routing :: 4503 - Get Switch For Datacenter?
Feb 9, 2013
We have microsoft servers and other application servers (around 12 in nos) which should have gig connections to the access switch. In turn this access switch will be connected to our distribution switch 4503. Which model of access switch best fits from the below 3 models. It should be cost effective as well.
I have 2 6504's running HSRP as my core. They are each etherchannel'd to my Datacenter switch (3750 Stack) -- see image below.The problem i a having is with the etherchannel status:
Core1 PO11 status w (waiting) Core2 PO11 status P(bundled)
DC11 PO48 status P -- but only to Core2 - the interfaces to Core1 are suspended. (See attached configuration documents) None of the devices have any information in the logs. I run this same configuration in my central location, but we are running Nexus 7000's. With the 6500's, do I need to split the port channels on the 3750 to allow them to negotiate the etherchannel? If I split the portchannels, are there any concerns? Should I expect to see the etherchannel status as P (Bundled) or H (Hot-Standby)?
We have two catalyst 6506 switches with 10 gb u plinks and around 120 edge switches cat 3750-x switches. Still the module on the core wheere servers are connected is 1000mbps port.Now if we induct a nexus switch to the datacenter what kinds of benefits we can reap In a virtulised environment as well as real environment?following are the some of the queries.Can we reduce the number of edge switches? ( by virtual environment), Inter operabaility between cat ios and nexus ios, how this will affect the environement,What will be the over all benefits ?, What are the cons of this induction ?
Currently we have cisco 4503 switch in one of our location without redundancy which servers below,
300 user (desktop & ip phones) 5 vlans 15 access switches are connected one L3 connectivity.
Actually i want to understand is it really necessary to have 4503 or we can go for 4900 series as we are planning to have redundancy in distribution segment.
Which is the best L3 switch in the above scenario and how to measure the overall performance of the current 4503 switch...
We have Cisco 4503-E switch and software version is cat4500e-universal.SPA.03.01.01.SG.150-1.xo1.bin. Now i have uploaded cat4500e-universal.SPA.03.02.01.SG.150-2.SG1.bin IOS-XE software in the switch and want to boot the switch from this image.
We had a core switch(30 vlans) in our environment and it's noticed that CPU utilization of the core switch is showing high during recent days. I have checked logs and processes, but couldn't find the root cause. The issue found only in the office hourly only(after that the cpu utilization is idle and normal). I have already referred the following link to troubleshoot the issue " [URL]
see the following outputs from the core switch
CPU utilization for five seconds: 99%/0%; one minute: 99%; five minutes: 99% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 30 6687557041432420936 466 47.52% 47.10% 45.98% 0 Cat4k Mgmt LoPri 55 30667074884269560256 0 45.36% 45.50% 45.85% 0 IP Input 29 28552856922870089254 0 3.59% 3.50% 3.57% 0 Cat4k Mgmt HiPri
[code]....
Note: Each Invalid source mac entry in each day from same port (above is the output after clearing logs before 3 days)
My queries regarding the issues are following
1) How can we find root cause regarding the high cpu utilization?
2) Is a single invalid mac address makes the cpu highly utilized for suppressing it?
We have two core switches in our network (Cisco WS-4503). HSRP is working as Active-Standby mode. Recently it has been found that core 1 (which is in active mode) shown high CPU load (60% - 100%). Also found that the below mentioned process takes more CPU. Our network consist of around 30 Vlans. We have already checked for the solution in Cisco website [URL] but couldn't find exact reason. see the below outputs for core 1 switch.
Core1# sh processes cpu sorted CPU utilization for five seconds: 55%/3%; one minute: 65%; five minutes: 71%PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 30 1606933521086983644 147 24.79% 29.93% 35.85% 0 Cat4k Mgmt LoPri 29
We had a core switch(4503) in our environment and recently we tried to enable syslog in the switch. But the syslog server doesnt receives all the configured level messages from the switch. Following is the only message getting in syslog server after the configuration change in switch.
%SYS-5-CONFIG_I: Configured from console by CWLMS onvty1
(No Traffic related messages like acl deny traffic, spanning tree events etc are getting to syslog server as well as log buffer of the switch)
Following are the logging configuration for the core switch
Small datacenter design. My requirements and setup will be as follows Dell PowerEdge M1000E Blade Chassis (initially one full chassis)Dell Powerconnect 10GbE Blade SwitchesDell Compellent Storage Array 10Gb iSCSI with redundant controllersDell Powerconnect 7024 dedicated external storage Virtual host blade servers 2 x Cisco ASA for firewall (5525-X or similar in active-active configuration)2 x redundant routers or switches as gateway to public internet I am looking to be able to segregate customers (approximately 100) into seperate VLANs at the access layer and route them up to the Cisco ASA firewalls using Dot1Q trunking for segregation. The Cisco ASA's will perform NAT functionality and route to the redundant gateways. I then need to police each customers traffic at the gateway to limit bandwidth and perform specific traffic marking along with simply routing out to the internet.
Budget is somewhat restrictive so I am looking for the most "cost effective" devices I can use at the gateway to perform the traffic policing/marking/routing for each customer.
we are planning a Nexus datacenter project with this layout:Our experiences with Nexus switches are not so large until now and the manuals are very extensive.Both N5K´s should be connected directly with all 4 N2K switches. I did not find a layout like this in the manuals. Only a design,where only 2 N2K are connected to one N5K, with this fex config:Now I´m not sure if it is right to make a config like this with the same slots and fex´s or with different slots and fex´s.
There is some way to increase the speed of changing the interface state from DOWN to UP when the cable is connected. I need to configure a port of Cisco 4503 in a way that when a cable is connected the port goes immediatly UP.
A solution can be to keep Cisco interface always UP and I remember that with "no keepalive" command to the interface configuration it was possible. But I tried and nothing happens.
I need to implement over an ethernet link L2 tunnel because I want to isolate another VLANs domain.On the first side I can use the command : sw mo dot1q-tunnel on a new C4503 on the other side I cannot configure the command : sw mo dot1q-tunnel.
the other side is an old C4503 we upgrade the flash with a compact flash to upgrade to a new IOS v15 but the command doesn't exist also.I red the cisco feature navigator feature and I am sure the dot1Q-tunnel is available on my image : cat4500-ipbasek9-mz.150-2.SG.binso I don't know why I can use it.
I am installing a connection between Brocade MLX and Cisco 4503 using SE and SVI's. Below is the config for each. Am I missing anything like MTU Ignore or something along that nature?
*** Cisco 4503 (v15.01) Config *** VLAN 35 name EOC_Gi1/2
I am trying to connect a 6509 switch to a 4503-E switch using single mode dark fiber over a distance of less than half a mile. Although a routine task, it does not work..We have a care 6509 switch where we concentrate all of our dark fiber connections for our remote sites. The 6509 switch already has 30 remote sites, most of them with 4503-E switches, connected in this way therefore it is a tested scenario. For the connections we use the GLC-LH-SM SFPs on both switches. Out of these 30 sites we had a similar problem with two of them, which we solved with the use of CWDM SFPs. With the CWDMs the fiber came up right away. However, I cannot keep using this solution because it is way too expensive! I had the losses of the fiber measured end-to-end and they are negligible (>0.5 dB).
In this latest case, like I said, we could not bring the connection up between the core 6509 switch and the 4503-E switch using the GLC-LH-SM SFPs. I then replaced the 4503-E switch with a 3560 and the link came up! Then I tried using a CWDM-SFP in the 4503-E, while keeping the GLC-LH-SM SFP in the 6509 and the link came alive again! Of course we already tried replacing the fiber patch cords with no luck. [code] I find it very weird for the link to work with the 3560 or with a CWDM in the 4503 but NOT with the SFP in the 4503!
I have a 4503 switch (in L2 mode) running 12.1 hooked into a C2950 running 12.1, using regular 4 pair Cat5e cables to connect between them. The 4503 has Gigabit port 2/1 trunking to the 2950's Fa port 0/13.
When I set the duplex mode to DUPLEX FULL and SPEED to SPEED 100 on both switches (for their trunk ports) the link fails, and my 4503 loses connectivity (since it gets it from the 2950).
Here is my config from the switches (per description):
After deleting configuration with „write erase“ and reloading, our Cisco Catalyst 4503 with version cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin, and licence ipbase, doesn't recognize any command regarding SSH. We tried configuring SSH key with „crypto key generate“, but that command is not recognized either.
I am working with a Catalyst 4503-E with a Sup7-E. I'm trying to enable Netflow, and I have read the following guides: Catalyst 4500 Series Switch SW Configuration Guide, Release IOS ...
I have also enabled Netflow in IOS 12.1/12.2 and figured the process was similar (It seems to be). CEF is enabled, and I have all the pre-reqs according to the document above, however, the flow commands don't exist, they simply say "command unrecognized". I have included my sh version below.
sh version (edited): Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSAL-M), Version 03.01.01.SG RELEASE SOFTWARE (fc1)
I have a 4503-e with WS-X4013+TS supervisor and WS-X4548-GB-RJ45 card. I purchased a WS-X4648-RJ45-E card and installed but IOS says its unsupported. Supervisor is running 12.2(46)SG software and 12.2(31r)SGA firmware. Obviously I'm hoping this cars can be supported somehow. Do I need to upgrade software or firmware, or return the linecard and get equivalent supported card? Oh, system is running Catalyst 4500 L3 Switch Software. (cat4500-IPBASEK9-M)
We have a gateway on a 4503, say on port 2/1, and we only want the other devices that are plugged into the 4503 to be able to talk to the gateway and thats it. The other devices are Motorola TUT DSL devices and they plug into the 4503 directly.
Normally "switchport protected" would make this very easy to keep stuff on one port from talking to other ports but with 4500's you are not able to do that command. So we implemented a MAC Access-List Extended ACL. Here is what we did
mac access-list extended BLAH permit #host 0000.XXXX.YYYY any interface range fa 2/5 - 20 mac access-group BLAH out
The MAC address 0000.XXXX.YYYY is the MAC address of the gateway that is plugged into Fa2/1 and the DSL TUT devices are plugged into ports Fa2/5-20. We would think that this config would only allow devices on the TUT DSL to talk only to the Gateway but we don't really think this is happening. The TUT devices are learning about MAC addresses that are on other TUT devices.
Do the cisco 4503 switches support virtual clustering feature ? I have a requirement where switch ports on two different 4503 switches need to combined in the same Link aggregation group . This is needed because the firewall notes say that the aggregated interfaces need to be conected to a single switch and combined in the same LAG . So according to the diagram below , the interfaces marked RED need to be in the same LAG in the switches , same for the interfaces marked BLUE . I have done the same setup using Juniper switches where it uses VIRTUAL CLUSTERING to group the different switch ports in the same LAG.
We had a core switch (4503), distribution switches and access in our network and consists of many vlans. Almost all vlans uses DHCP Pools. But for few vlans DHCP is not yet configured. Recently one of the rogue user in vlan 1 gave the corresponding interface vlan ip of core switch (gateway) as his ip and caused a prolonged network outage for the vlan. Any way we are going to seggregate vlan 1 into different vlans, but before that we need a temporary plan to block such kinds of attack.What are the possible ways we can avoid the network outage problem even if a user gave the gateway ip to the machine?
recommend a cisco core switch and access switches in IPTV network infrastructure?I was ask to implement a network for IPTV system but i don't have idea what will be the model i will use.
we have Core-Siwtch 4503 in the main building which is connected to another Core 4503-E in another building ,, now our PCs connected to the 4503-E ,,, any XP M/C can pick an Dhcp-ip but and M/C run Win.7 Cannot !!
action taken :
1st we try to connect our win 7 pc in the node which was connected to xp M/C ,, and it didnot take ip from the DHCP . ,, 2
2nd we ensure from the core-switch configuration and its normal with no mistake
3rd trying to use tool from Microsoft Fix-it Center whih name is ( Microsoftfixit 50475 ) which is just .msi file but the problem face us is that this tool donnot accept to run on win 7 cause its made for vista .
4th after some researchs we notic that there is some modifications have to be performed on registery by disabling the dhcp broadcast flag we did it but nothing change yet
5th now we are waiting to perform another action which is Disable the IP Helper service in win 7
I need 10gigbit uplink for this switch. What are the other devices that i need order along with this device.And what is the diff between X2-10GB-LR= and CVR-X2-SFP.if i take CVR-X2-SFP, in future how can i upgrade from one gig to 10 gig?for current use i need 10gig support required. so what are all the other devices that i need to order.Fiber multimode and distance 15Mt only.
i have an issue to connect a trunk between cisco switch and extreme switch i have many vlans that i want to cross via a link between cisco 3750 switch and a Extreme Alpine 3800 switch
I have two 3750-X configured to be a stack and I am planning to re-rack these somewhere else. What I would like to know is what are the effects of having the master switch itself lose power? Does it immediately just make the member take over master (there should be no election since there are only 2 switches??) and there would be no loss of connectivity?
I have a Catalyst 4006 switch in production and a spare switch of same model. I have to quickly copy the configuration from production switch to spare switch (both L2 and L3 configurations) How do I do that?
The last few days I've been exploring options in getting rid of some old routers accross a wan connections. I have a cat 3560 to play with and I thought I would try and use the no switchport command test out routing with switch. I've got some type of route issue and I tried a few things which I thought would fix the issue but had no effect. I'll post the config and a few commands so you can see what the basic setup is.
Here we can see in the arp that it knows about both 10.7.1.2 (PC unable to ping 10.3.3.254) as well as 10.3.3.254 (ASA).I tried adding in a ip route of 10.7.0.0 255.255.0.0 10.3.3.110 as well as 10.3.3.254. Neither produced the results I wanted allowing 10.7.1.2 (PC) to ping the ASA (10.3.3.254). [code]
I have been looking into this for a while and I can't seem to figure out why my 2nd vlan is not able to connect properly to the net.
My switch has 12 ports where my devices connects directly, they are all on Vlan 1 and they all work perfectly. on Port 12 I have a dlink router that is connected to a cable modem. the dlink router has an Ip address of 192.168.0.20
I created a second vlan (vlan2) and enabled dhcp relay on it. then I assigned port 9 on the switch to (vlan2)my laptop which is connected to port 9 seems to get an ip address fine and able to ping only some devices on my network (vlan1) and is not able to go out to the internet. I think it has to do with the routes. [code]
I have the task of replicating the router config on a 3825 router on a 3750 switch. Reason is we are taking out the router and replacing it with the switch to make use of the router for other functions.
Below is main part of the router config:
! ip source-route ip cef ! ! multilink bundle-name authenticated ! license udi pid CISCO3825 sn FCZxxxxxxx ! vlan internal allocation policy ascending
[code].....
The 3750 switch I have runs C3750E-UNIVERSALK9-M, Version 12.2(55)SE3 on a LAN BASE license.
The first thing I have done is to order for a license upgrade to IP BASE which would give the support for OSPF routing.I do not see much of an issue with the Interface configs, however, I am not too sure about replicating the routing config on the switch.
My question is can I run the commands as shown for the OSPF routing on the switch? If not, can I get suggestions on how best to set this up on the switch?