Cisco Switching/Routing :: Faulty State In New Module Inserted In 4500
May 18, 2010
We inserted a new module with 48 rj45 ports in a 4500 with just one supervisor module. We have two 4500, and we tried the new model in the other 4500 and it´s working properly and giving a OK status. Furthermore, the module´s LED status is green. We saw that there are 8 ports (from 17 to 24) that are in faulty state, so probably this is the cause for the faulty state for the module.
We tried already a Hw reset, replace/insert again the module...
We are almost sure that it can be a Hw failure. We are getting the following results different commands:
show module :
Mod Ports Card Type Model Serial No.
7 48 10/100/1000BaseT (RJ45) WS-X4548-GB-RJ45 JAXXXXXXXH
M MAC addresses Hw Fw Sw Status
[Code].....
View 10 Replies
ADVERTISEMENT
Jun 3, 2013
I have configured a SVI in my 4500 ( Sup 7-E 10GE,,,,,,and,,,,,cat4500e-universalk9.SPA.03.02.00.SG.150-2.SG.bin) switch and it is showing Down Down, because there were no active switch port in the vlan, I added one switch port to this vlan but this port also in the down state, so i added the SWITCH PORT AUTO STATE EXCLUDE command under this port, even after this also the SVI never came up, So i added one systen to the port so both the switch port and the SVI came up...So why SWITCH PORT AUTO STATE EXCLUDE command have no effect in this model of the switch..
View 4 Replies
View Related
Apr 7, 2012
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command:
Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
View 6 Replies
View Related
Jan 7, 2013
We have recently purchased a Cisco 4506 that has several Gigabit Ethernet modules installed.One of the Ethernet Gigabit modules - a WS-X4424-GB-RJ45 - is being picky with who it talks to at Gigabit Ethernet.
If I plug a laptop into one of it's RJ45 ports using a Cat 6 cable, nothing happens. No link light, no notification of link up or down on port statistics, absolutely nothing.If I plug a server into the same port it works fine at Gigabit Ethernet (even using the same Cat 6 cable).I can get the module to recognize a laptop if I fix the speed/duplex on the laptop to 100Mb/Full. I have tried this with other staff laptops from different vendors (HP / Dell / etc.) all with the same result.
The module directly underneath this module - a WS-X4448-GB-RJ45 - works fine for both laptops and servers. We have tried swapping the module positions but to no avail.
View 9 Replies
View Related
Jun 4, 2012
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
View 1 Replies
View Related
Apr 15, 2013
We have a faulty FWSM module in Cisco 6509 switch in Active/Standby cluster mode
We have purchased a refurbished FWSM module to replace it. It has the same FWSM OS 4.0 (4) and is in factory default configuration
What procedures should I follow to make this unit live and sync the config between the current active unit to this one.
View 1 Replies
View Related
Apr 20, 2013
I have a new 8881G-w router with the following info:
(C880DATA-UNIVERSALK9-M), Version 12.4(22)YB2, Serial No. FTX1331830T
Need activating the CDMA . when I tried to login to the Cellular interface it shows me the following warning:Warning: 3G Modem is not inserted Configuration will not be effective until modem is inserted
I want to activate and configure CDMA and i don`t know from to start..
View 3 Replies
View Related
Nov 30, 2012
I need to replace a faulty fan unit on the catos WS-6509 switch. this Catos switch does not support show inventory so any other catos commands which will show me this part id?
View 2 Replies
View Related
Oct 23, 2012
I would like to request assistance from all the gurus here for an issue i have with a Cisco 7513MX PSU. There probably arent many people who are aware of 7500 chassis as they are quite old.Isse: PSU 1 failed in chassis and we tried to replace it. Once replaced, we are getting the following output for it:
1#sh env all
Arbiter type 2, backplane type 7513MX (id 2)
Power supply #1 is TBD (id 0), Power supply #2 is 1200W AC (id 1)
We have been researching on the internet for answers but unfortunately due to the age of this model, there is very limited information available. We did find information which suggested to have BOTH PSU 1 & 2 with same revision. Right now the chassis is running only on PS2, we dont want to take down the chassis just to confirm the revision number on the PSU and there is no way to see that on the CLI. What we can do is get another pair of same revision PSUs, insert PSU1 first THEN take out PSU2 and then insert the same revision as PS1 in PSU2 slot but the moment we insert PSU1 in we get that TBD state which is not normal status and raises our doubts about putting the same revision PSUs with the method above, there is a chance that after we insert PSU1 in, the moment we take out PSU2, the chassis might not run on PSU1 due to its abnormal state.
View 5 Replies
View Related
Jul 12, 2012
We did an upgrade from NX-OS 5.1.5 to 5.2.4 and found all M1 line card interfaces were stuck in initializing state for long time.'show module' status says ok. And we cannot execute shut/no shut command under the interface. N7K-M108X2-12L & N7K-M148GT-11 are the two M series cards. Only option was to downgrade back for the time being.
N7K01# sh int e1/1 | in down
Ethernet1/1 is down (initializing)
View 3 Replies
View Related
Aug 7, 2011
I have two Cisco 6500 switches connected via fiber, this is my small network. One end goes to a provider, and the other end goes to a server. My IT department wants some sort of link state propagation since the provider keeps going down, but the IT team is unaware until they contact me.
We provide a Layer2 point-to-point circuit, access ports at the ends. We use V LAN's to transport the traffic. Please let me know if there is anything I could do to support link state propagation.
View 4 Replies
View Related
Apr 18, 2012
indicate why my ethernet ports are in suspended state for some reason, i need an indication why this may be and what i can do to fix this issue. configuration below. I have a 7010 which i'm using to connect to two 5510's. I have one vPC connecting the two 5510's to the 7010. I have a vPC domain configured between the 5510's. and no issues at all. My Nexus 7010 port channel members are suspended for some reason.
Nexus 7010
vpc domain 100
role priority 100
peer-keepalive destination 192.168.1.2 source 192.168.1.1 vrf vpc-keepalive
!
interface Ethernet 3/1
[code]....
View 14 Replies
View Related
Jan 25, 2012
I am testing 2960 24 S with storm-control and Errdisable Port timer interval 60s , connected HUB on fa0/17 to make traffic / loop.After Strom Control detection the interface goes down thats ok after 60s they will try to recover the interface and going up although the loop is still there.For my understanding if the interface detect still a loop on that interface they will disable the port again for 60s and will check again. [code]
View 7 Replies
View Related
Jun 29, 2012
We have a number of 3750 stacks used as access layer switches connecting Siemens VOIP phones and then a PC that connects to the phone.
For example if I plug PC A to the phone that connects to port 13 I pick up an IP addressand all works as predicted now if I plug in PC A to any other VOIP phone that connect to another port on the same switch it goes in error disable state ITs like the switch is holding my PC mac address and locks it down with the port which in my case is Gi2/0/13.
interface GigabitEthernet2/0/13
switchport access vlan 726
switchport mode access
[Code].....
View 7 Replies
View Related
Mar 30, 2013
I am cascading one new switch 3750G (int Gi1/0/1) with an existing 3750G (int fa1/0/26) switch.. But the interface fa1/0/26 goes in err-disable state even after NO SH.. also i have diable Spanning treebpdu guard and disable spanning tree portfast. But still the issue is not resolved.
View 6 Replies
View Related
Dec 9, 2012
We have a pair of 6500 switches, each having a trunk going to each access switch. We set the spanning tree priority on Core1 so it is the root bridge for all VLANs. We have two different types of access switches:
-3550 setup as VTP client and ISL
-2960 setup as VTP transparent and dot1q.
Pruning is disabled but we use "switchport trunk allowed vlan" to restrict which VLANs go through each trunk. When we need to permit a VLAN through a trunk, we simply run "switchport trunk allowed vlan add <VLANID>" on the access switch and both core switches. If it is a 2960 in VTP transparent mode, we must set the VLAN to active. Once this is done, a "show int trunk" will reflect the new VLAN in "Vlans in spanning tree forwarding state and not pruned" for Core1.
I recently went through this process to add VLAN 250 on a 3550 access switch, but the VLAN is not listed in STP forwarding state and not pruned. I tried removing the VLAN from the trunks and redoing it, but there is was no change. I tried adding VLAN 257, but the same behavior happened. I then tried trunking the same VLANs to a few other access switches. Three other 3550s experienced the same behavior, but I was able to trunk the VLAN to a few 2960 switches. At this point, I figured it might be related to some kind of limitation of VTP or the 3550 switches. I provisioned a new 3550 with the same IOS and settings (VTP client, ISL). To my surprise, all VLANs configured were in STP forwarding state and not pruned.
Running show spanning-tree on the core and access switch shows VLAN 250 as designated FWD. I confirmed we are not hitting the limits in "show spanning tree summary totals" on the Core or Access switches. I also confirmed we are not hitting the virtual port limit by running "show vlan virtual-port slot x."My next action might be to shut/no shut the uplink to Core1 from the access switch, but I'm not sure if that will fix it and even if it does, I have no clue what caused the issue.
View 11 Replies
View Related
Mar 28, 2012
I have a Catalyst 2950G when I activate the switchport port-security, but I want to empty the black list of mac address because every time I connect a device, the port is automatically désacative, here is the port configuration:
!
interface FastEthernet0 / 2
switchport access vlan 17
switchport mode access
switchport voice vlan 51
[code]....
I tried the following commands to clear the blacklist mac address of that port, but the problem is still relevant:
# Clear mac-address-table dynamic int fa0 / 2
# clear port-security all int fastethernet 0/2
# clear errdisable interface fa0 / 2 vlan
View 17 Replies
View Related
Jan 24, 2012
I have catalyst 6500s with two VS-S720-10Gs, one is in Active and one is in Hot state. Both Sup cards have two 10G uplink ports. How does the traffic forwarding works in this case on the uplink ports? Do these uplink ports actively forward traffic or it is only the uplinks ports on Active that forward traffic? I see CDP neighbors on both Active and Hot SUPs uplinks ports - it indicates that packets are flowing on both cards.
I want all uplink ports on both SUPs to actively forward traffic. Does it work? What is the config for this?
View 1 Replies
View Related
Jul 28, 2012
Im wanting to add an additional module in to my Cisco 4500. Is as simple as plug and play or is there some commands that I need to add or anything I should be aware of.
View 2 Replies
View Related
Mar 9, 2012
Recently on two switches, both being same cisco WS-C3750E-24PD, running with same IOS c3750e-universalk9-mz.122-58.SE2.bin got noticed that the license state of one switch is showing incorrectly as shown below [code] I will not be able to execute any changes/modifications on switch as of now.
View 9 Replies
View Related
Jan 23, 2012
I have cat4500 swtiches & need to monitor interface bandwidth utilization over NAM installed 6500 chassis. How can I monitor traffic utilization over NAM like we do in PRTG/MRTG/Cacti ?
View 0 Replies
View Related
Mar 6, 2013
I need to know if Catalyst 4500-X does PBR in hardware?
View 1 Replies
View Related
Feb 28, 2012
Does the 4500 support VSS (Virtual Switching System) ? On the official product overview page it says: 1.6 Terabits capacity with Virtual Switching System (hardware-ready)What means Hardware ready ? Does it mean that it supports VSS in the same manner as the 6500 ? The reason I'm asking this question is that I didn't find any info on the Internet about this. We would like to upgrade our network by interconnecting the 2 sites with Layer 2 redundant links (Layer 2 extension), but I'd like to use the both links in a load-balancing manner, which can be a real pain in the *** with STP. The choice is between 4500 and 3750 stackable core switches. The 6500s are very expensive.
View 6 Replies
View Related
Apr 3, 2013
question on 4500 SUP-7LE, this documentation is not 100% clear:
[URL]
When in single sup mode, can I have the following combinations?
1 SFP+ and 1 SFP << pretty sure this is supported
1 SFP+ and 2 SFP << think it's supported
1 SFP+ and 3 SFP << doubtful
2 SFP+ and 2 SFP << think it's supported
3 SFP+ and 1 SFP << doubtful
View 1 Replies
View Related
Nov 16, 2009
I'm seeing the following error on a 4500 running 12.2(46)SG
C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Module 5 inline power exceeds threshold: status changed to 'Pwr Over'
All the ports on module 5 have "power inline never" applied, in fact the whole switch has POE disabled.
I've attached a txt file with the show power detail output.
View 2 Replies
View Related
Apr 22, 2013
How to know 4500 SUP7-E's MIB ?Our customer use MS SCOM 2012 SP1 get the OID are 1.3.6.1.4.1.9.1.1286, but we use IOS MIB locator, we can not find this MIB id.
below are the IOS sh version information :
Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSAL-M), Version 03.02.00.SG RELEASE SOFTWARE (fc4)
Technical Support: [URL]
Copyright (c) 1986-2011 by Cisco Systems, Inc.
Compiled Tue 26-Apr-11 18:09 by prod_rel_team
[code]....
View 2 Replies
View Related
May 13, 2013
What is the correct way to lic VSS on a 4500 SUP7L-E ? url... Under Table 5 - Support by Image Type; VSS is listed as available on IP Base (SUP7E only) and a plain Yes under Enterprise Services, inferring that you need Enterprise Services lic on SUP7L-E to get VSS? url...Under Table 1 - Minimum License for VSS; IP Base or higher (7-E) or special license (7-LE and Catalyst 4500-X)Can find no option on CCO / configuration tools to list a 'special' VSS license for 4500R+E chasiss with dual SUP7L-E and IP Base.How are you meant to purchase/license VSS on 4500E Chassis + SUP7L-E ?
View 6 Replies
View Related
Dec 14, 2011
Why Cisco 4500 R switch PBR tracking Command not working , I found just route-map next-hop ?
View 3 Replies
View Related
Sep 7, 2012
My 4500 core always in 60 % cpu utility , and when i run #sh proc cpu sorted i find that
55 29725041543795572214 0 39.43% 41.40% 41.39% 0 Cat4k Mgmt LoPri
Which mean that this process is the top one , and when i run #sh platform health i found that Stub-JobEventSchedul
10.00 15.98 10 64 100 500 20 17 12 29269:55 K2 CpuMan Review
30.00 35.60 30 48 100 500 49 46 32 52390:52
Those two process are the top and they already exceed their maximum rang and when i run #sh platform cpu packet statistics i can find that Packets Received by Packet Queue
Queue Total 5 sec avg 1 min avg 5 min avg 1 hour avg
---------------------- --------------- --------- --------- --------- ----------
Esmp 5053121950 475 462 340 326
L2/L3Control 244395185 17 8 5 11
Host Learning 67315739 0 0 0 0
L3 Fwd Low 346689615 73 23 14 13
L2 Fwd Low 5336180603 1180 1129 831 804
L3 Rx Low 2287913 0 0 0 0
RPF Failure 7510829 1 0 0 0
View 2 Replies
View Related
May 23, 2012
How i can configure the SFP Ports on my 4500 SERIES CHASSIS with other SFP ports on the connecting switch. I want to connect 15 switches via GLC=SX=MM to my 4506E sfp card.
View 4 Replies
View Related
May 15, 2013
I am getting a very strange problem where 4500 switch is remarking the packet with dscp 1 to 0.
Let me explaint the setup. I have two PCs connected on same switch but on different modules. PC1 is conencted to Gi4/19 and PC2 is connected to
Gi2/43. Both the ports has been configured to trust the dscp. Below are the configuration:
interface GigabitEthernet4/19
switchport access vlan 6
switchport mode access
[Code].....
View 7 Replies
View Related
Jan 8, 2012
I am trying to setup the WOL for our enterprise. We have a C4500 setup with mutliple Vlans. We are using Microsoft SCCM server to wake up workstations for security update. The workstations are on vlan190 and the Microsoft server is on vlan 441
Here's my config
the config below
interface Vlan190ip directed-broadcast 100 (Enables the translation of a directed broadcast to physical broadcasts)
access-list 100 remark ====== Wake-On-LAN ======no access-list 100 permit udp host 10.4.40.98 any eq 9 logaccess-list 100 remark ====== End of ACL 100 ======
[Code].....
View 2 Replies
View Related
Mar 12, 2013
We have 3 layer LAN architecture, layer 1 of 6500(IP routing), layer 2 of 4500(L2 switch only), layer 3 of 2960(L2 Switch)In a Single (2960 and 4500) Switch Port Avaya IP phone and PC are connected.Now, the requirement is that, Qos need to be configured for Voice traffic and Data traffic should be in default class of service.We plan to use COS value in Switch 4500 and 2960. We made a sample configuration as below
### For 4500 Switch
class-map match-all VOIP-Access-2MB
match cos 3 5
class-map match-all VOIP-Uplink-20MB
match cos 3 5
[code].....
check these configurations are correct as per standard and if there is any other method of configuration?What need to be configured in L3 Switch(6500)??In 2960, it doesn't support ingress QoS, what impact it will make when compare to 4500? do users experiance any difference?
View 1 Replies
View Related