Cisco Switching/Routing :: Hang During Boot Of WS-C4948-S Switch

Apr 3, 2013

I encountered an issue while trying to boot Catalys WS-C4948-S switch. I power on the switch and I'm able to see the boot messages thourgh serial console cable. But it gets stuck at line "Image text-base: 0x1000000, data-base: ..... ". Also I can enter into rommon mode. I tried to use different kinds of IOS images, tried to boot from tftp but with no luck, the issue is the same.
 
There are no erros on the screen, it just gets stuck when it enters into IOS, so I don't see the IOS prompt.

View 5 Replies


ADVERTISEMENT

Cisco Switching/Routing :: VSS Switch Got Hang After Inserting 6708 Module?

Jan 11, 2012

We having a VSS switch (9 slot chasis) with ios "s72033_rp-ADVENTERPRISEK9_WAN-M), Version 12.2(33)SXI4", slot 7-9 are currently free. We wanted to install WS-X6708-10G-3C module on slot 7. Once we installed the module it didnt come, after waiting for 15-20min again we removed and inserted, but module didnt come up and we could see following logs on the console:
 
Jan 12 08:57:40.146: %ISSU-SW2_CFC2-3-ERP_AGENT_SEND_MSG: client/entity send failed; error code is timeout
*Jan 12 08:57:40.330: %ISSU-SW2_SPSTBY-3-ERP_AGENT_SEND_MSG: client/entity send failed; error code is timeout
Jan 12 08:57:40.146: %ISSU_ERROR-SW2_CFC2-3-START_NEGO_FAILED: ISSU NTI Client(2040): failed to start negotiation (ISSU_RC_CLIENT_ENTITY_DOES_NOT_EXIST_IN_PEER)

[code]....

Afer some time VSS switch didnt response to console commands and all the users in access switches were not able to reach the gateway (VSS). Then the problem disappeared once we rebooted both the switches in VSS.why the VSS switch become non-responsive?

View 1 Replies View Related

Cisco Switching/Routing :: 3750 Switch Connected Computers Hang For Few Minutes

May 6, 2013

In my customer having 3750 switch and they have simply assign IP address for vlan and enable telnet in switch and other things are same as default switch.In this switch they have connected 8 cisco layer 2 switches(6 managed and 2 unmanged switch) and approximately 5 servers connected in this switch.In a particular interval,users accessing File server are connected to 3750 switch become hanged for few min.This happen for some particular interval.users accessing this server becomes entirely hanged for few min,then i have configured port monitor cmd and i have installed one wildshark tool to host connected directly to that switch.

View 3 Replies View Related

Cisco Switching/Routing :: Cannot Boot IOS On Switch 4948

Jul 14, 2012

I cannot boot IOS, when i reload this switch it go to ROMMON. I try to uploand IOS but it still has problem. i think i may wrong some point during i did uploand.
 
This is problem
 
Switch#sh bootvar
BOOT variable = cat4500-entservicesk9-mz.150-2.SG3.bin,1;bootflash:cat4500-entservicesk9-mz.150-2.SG3.bin,1;bootflash:cat4500-entservicesk9-

[Code].....

View 2 Replies View Related

Cisco Switching/Routing :: 6506-E Switch Always Boot With Old IOS

May 4, 2012

I tried to upgrade IOS from SXI2a to SXI9 in cat 6506 VSS. But the problem is that switch always boot with old IOS. I put the new IOS in sup-bootdisk and slave sup-bootdisk, bootvar is ok with new IOS: [code] Show bootvar  is ok but switch always boot with old IOS SXI2a, some bug in IOS sxi2a???, I will try to delete de old IOS from sup bootdisk and try with the new one only.

View 5 Replies View Related

Cisco Switching/Routing :: 6513 Switch Boot To ROMmon

May 9, 2012

i have a Cisco 6513 it is used one, i have tryed to boot it but it did not work, it alwayes go to rommon mode and i am not able to know what is the issue,
 
when it boot i get the below outpot from the switch.
 
System Bootstrap, Version 8.1(3)
Copyright (c) 1994-2004 by cisco Systems, Inc.
Testing lower main memory - data equals address

[Code].....

View 3 Replies View Related

Cisco Switching/Routing :: Boot 4503-E Switch From Secondary Image?

Sep 13, 2011

We have Cisco 4503-E switch and software version is cat4500e-universal.SPA.03.01.01.SG.150-1.xo1.bin. Now i have uploaded cat4500e-universal.SPA.03.02.01.SG.150-2.SG1.bin IOS-XE software in the switch and want to boot the switch from this image.

View 17 Replies View Related

Cisco Switching/Routing :: SF 300-24 Switch Won't Boot After VLAN Config / Reboot

Jul 28, 2012

I was trying to configure an SF 300-24 for use in my home and obviously did something dumb. It was working fine. The f/w was updated and I had configured 2 VLANs. VLAN2 was ports 1-6+GE1 for IPTV streaming and VLAN3 was ports 7-24+GE2 and GE3 for the rest of my LAN. I was plugged into GE4 and was configuring the switch with a laptop. GE4 was the only port still on the default VLAN1. I chaged the default VLAN to VLAN3, which forced a reboot and the switch never came back up. Attached is what I see when I connect to the console port: [code]

I can't access to GUI using it's static IP or it's default IP on any port and the console never reaches the point where I can log in. The System light is flashing green but the boot sequence never progresses past what's in the screen shot. I tried to do a hard reset using the recessed button on the front panel but it does not seem to have any effect, no matter how long I hold it down.

View 5 Replies View Related

Cisco Switching/Routing :: C4948 - Message In System Log

Apr 29, 2013

I'm using "WS-C4948(12.2(54)SG)+PWR-C49-300AC/2". The following message are logged in the system log, but it was to check the status with the show command and status LED, but there was no abnormality. I thought the power supply has failed, but I seem different.

040861: Apr 27 07:00:50: %C4K_IOSMODPORTMAN-4-POWERSUPPLYBAD: Power supply 1 has failed or been turned off
040862: Apr 27 07:00:50: %C4K_IOSMODPORTMAN-4-POWERSUPPLYFANBAD: Fan of power supply 1 has failed
  
I checked.>> #show environment alarm no alarm
#show environment status power supply
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
------  ----------------  ---------  -----------  -------  -------
PS1     PWR-C49-300AC     AC 300W    good         good     n.a.
PS2     PWR-C49-300AC     AC 300W    good         good     n.a.
 
All Status LEDs are green.

View 5 Replies View Related

Cisco Switching/Routing :: Boot System Configuration In 3750 Stack Switch

Dec 13, 2011

boot system switch all flash:c3750-ipservicesk9-mz.122-55.SE1/c3750-ipservicesk9-mz.122-55.SE1.bin;flash:c3750-ipservices-mz.122-25.SEE2/c3750-ipservices-mz.122-25.SEE2.bin We have two stack of 3750 switches. When I enter above command getting below mentioned error, two images are showing switch 1, but one image only showing in switch 2, i.e 1st image in show boot command.
 
%Command to set boot system switch all  flash:c3750-ipservicesk9-mz.122-55.SE1/c3750-ipservicesk9-mz.122-55.SE1.bin;flash:c3750-ipservices-mz.122-25.SEE2/c3750-ipservices-mz.122-25.SEE2.bin  on switch=2 failed

View 5 Replies View Related

Cisco Switching/Routing :: How To Delete Vlan Configuration On C4948-10g

Jul 1, 2012

Working on a C4948-10g switch. Trying to reset switch to factory settings. I have ran the Switch#>wr erase, command but the vlan's are still in the config. If you do a show vlan it still shows all the vlan text. I have tried the Switch#>delete vlan.dat, doesn't work. Tried Switch#>delete nvram:vlan.dat, doesn't work. Tried Switch#>erase startup-config, doesn't work. How can I get rid of the vlan's?

View 7 Replies View Related

Cisco Switching/Routing :: Trigger Packet Drop On WS-C4948

Feb 25, 2013

I am running  (cat4500-ENTSERVICES-M), Version 12.2(53)SG2 on the switch. I have a scenario where I have 3 end user equipments connected to a Cisco 4948 L3 switch. At the switch end port 1/46, 1/47, 1/48 are the terminating points for these 3 devices . I have added these three ports to VLAN140 (switch port access vlan140 on the gig interfaces).

The device connected to 1/46 is the one I'm testing some signalling features on. My requirement is to have intermittent packet drop on this interface so that my signalling associations would go down now and then. I'm trying to simulate a real-time network congestion/latency/packet drop in a simple manner.

I do not want to shut/no shut the 1/46 intf to cause this. Some way to achieve intermittent packet drop on this gig1/46 intf ?

View 3 Replies View Related

Cisco Switching/Routing :: 3560 Switches Hang Off With Sub Interface

Jul 22, 2012

Was building a small network in Cisco Packet Tracer and ran in to an issue.  I have 4 routers running OSPF, and off one of the routers I have 5 3560 Multilayer switches.  The router that the switches hang off of, I have a sub-interface with dot1q encapsulation, set for vlan 10 and an IP Address. 10.14.16.1/24.  The switches have interface vlan 10 configures, and have IPs in the same subnet.  From that router, I can ping/telnet to all the switches without issue.  My problem arises when I try and reach those switches from any other router.  OSPF is set to redistribute static and connected subnets.The routing table is populated correctly on all the routers.  When I ping and trace the packet, it looks like it makes it all the way to the respective switch, but the packet never makes it back.  I've played with the default route on the switches to no avail.  Am I trying to implement this incorrectly, or am I just missing something?

View 4 Replies View Related

Cisco Switching/Routing :: 4507-R Installed At Customer Site Which Hang Twice

Oct 26, 2011

We have Cisco 4507-R installed at customer site which got hang twice and became normal after getting booted.I have analyzed show tech-support for this switch after reboting but not found relevant logs for hang issue,

View 7 Replies View Related

Cisco Switching/Routing :: 2811 / Hang And Reboot Router Every 3-4 Hour?

Jan 1, 2012

I have Cisco 2811 secure router in my network.  Seven day before it has been hanging every 3-4 hour. i have updated "c2800nm-advsecurityk9-mz.124-17.bin" IOS in the router.  After that it giving some error and every 7-10 hour network has been delay in LAN as well as WAN and not pinging.

View 7 Replies View Related

Cisco Switching/Routing :: 2811 Router Hang Frequently And Restart?

Dec 25, 2011

i have facing problem in my Cisco Secure router 2811.  It hanging every 5 to 10 minutes and restart.  IOS of cisco router is 12.4 ipsecurity. I have attached the error log and configuration file of my router.  Kindly see the log and let me the problem in my router. 

View 9 Replies View Related

Cisco Switching/Routing :: ME3400 Boot Loader - Intervlan Routing

Sep 5, 2012

On cisco and am having some issues with intervlan routing. I have followed the vids and manuals but just can seem to get this working. I have the following network lab set up.
 
Vlan 10 = 10.70.1.9/24
Vlan 20 = 192.168.0.1/24
ME2400 firmware
ROM: Bootstrap program is ME340x boot loader
BOOTLDR: ME340x Boot Loader (ME340x-HBOOT-M) Version 12.2(35r)SE3, RELEASE SOFTWARE (fc1)
[Code]...

View 4 Replies View Related

Cisco Switching/Routing :: 3560x Won't Boot

May 23, 2012

I unpacked a new 3560x and went to put our standard code version on it c3560e-ipbasek9-mz.122-53.SE2.  Everything seemed to upgraded fine but it won't boot to a console prompt.  It seems like it loads the IOS image fine but can't get passed the Front-end Microcode IMG MGR: Programming device 0. [code]

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 3750 Won't Boot

Apr 9, 2013

my Catalyst 3750 switch. Following a power cut the switch no longer boots up. The SYST light flashed green but no POST checks are made. I cannot see any boot messages from the console port either. The switch was on a UPS but some thing may have damaged the switch.

View 7 Replies View Related

Cisco Switching/Routing :: 871 Would Router Boot Seeing 52MB

May 30, 2012

What would happen if I installed a 32MB (MEM870-32F=) flash upgrade card in to a Cisco 871 router that already had 28MB flash on-board already? Would the router boot seeing 52MB (the max this router can have) or would it fail completely since the combined total would be over 52MB?
 
I know you can get a 24MB upgrade card but they are quite expensive.

View 4 Replies View Related

Cisco Switching/Routing :: 2801 Cannot Boot IOS From TFTP

Aug 27, 2012

i want to boot my Router's IOS from TFTP server but when I use the command: boot system tftp c2801-adventerprisek9_ivs-mz.124-24.T7.bin 172.16.10. 200; after that I write-mem, it shows the log:

-Router#wr
-Building configuration...
-ROMMON: out of room in table, cannot set "BOOT"
 
And when I reload the router, it cannot boot IOS from TFTP Server, sure my TFTP work well and 2801 can ping to TFTP.

View 1 Replies View Related

Cisco Switching/Routing :: SVR3500 / Unable To Get Boot File Into The GUI

Oct 22, 2012

I can see the boot file at 192.168.100.1  but I can never get into the GUI. The unit boots up, fans running. Eventually the power light flashes red. I don't have the unit hooked up to anything else except a laptop to try and configure it.

View 0 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Boot Process?

Mar 19, 2013

document which explians normal booting sequence in a 6500 Switch running IOS. What I am looking for is in which order the image is loaded in SUP, RP, SP etc

View 1 Replies View Related

Cisco Switching/Routing :: 4500 Can't Find A Boot File

Jan 6, 2013

I have a 4503-E on my work bench.  It's been out of production for a year or so.  I started working on it last week.  I think I may have cause a boot up problem.  It comes up to ROMMON, but then I need to type "boot" to get it to come up all the way.                    
  
config-register = 0x2102Autobooting using BOOT variable specified file.....
 
Could not find a valid file in BOOT environment variable.BOOT variable can be set from IOS. To find currently setRom Monitor variables, please type 'set' command.
 
For choosing a boot method,  type 'confreg' command. rommon 1 >
For choosing a boot method,  type 'confreg' command.rommon 1 >
 
At this point I type "boot" and it proceeds to the normal bootup.  (Below are a couple more print outs)
 
RG-4503#RG-4503#dir /allDirectory of bootflash:/
1  -rwx    12185732  Feb 21 2008 08:23:59 -06:00   [cat4500-ipbase-mz.122-31.SGA3.bin]    2  -rwx    14787732  May 21 2008 01:00:30 -06:00  cat4500-ipbasek9-mz.122-44.SG.bin    3  -rw-        7315      Dec 31 2012 07:13:15 -06:00  ***
61341696 bytes total (34360532 bytes free)RG-4503#RG-4503#RG-4503#show run | include bootboot-start-markerboot-end-markerRG-4503#

It looks like there is nothing between boot-start and boot-end. 

View 6 Replies View Related

Cisco Switching/Routing :: 6500 Not Booting Neither From Boot Disk

Jul 23, 2012

One of the 6500 was going in bootrom mode,  so I have formated the flash disk using the other Cisco 6500 switch and copied IOS file to the  boot disk. But the 6500 booting failed.

View 6 Replies View Related

Cisco Switching/Routing :: SUP720 - Unable To Boot From Disk0

May 26, 2012

Customer is using SUP720 with SP rommon image version 8.1(3), he is trying to boot the new ios image from disk0, but he gets invalid magic error. he fomat the disk0 but still he gets error when he boots from disk0. He suspect that it can't be flash problem but can be software of hardware as he has two flash with same issue on 2 switches.
 
Customer wanted to recreate, I tried in the lab, i was able to load from disk0, but sup in lab had 8.5(4).
 
Customer wanted me try with 8.1(3) version. But i was unable to downgrade the SP Rommon image. SP rommon is running in Gold region and I loaded the 8.1(3) from both disk0 and sup-bootdisk, even preferrence was given to region1 but still sup came up with gold region itself.

* Will i be able to downgrade from 8.5(4) to 8.1(3), if so, what are the steps.

* is there any limitation or bug where  8.1(3) will be unable to read disk0.

View 4 Replies View Related

Cisco Switching/Routing :: 6503 E Series Boot Image

Dec 14, 2012

I have a cisco 6503 - e series switch which runs c6sup22-psv-mz.121-26.E4.bin. Both superviser engine and MSFC2 card run the same IOS image i guess. In my boot flash their is another image c6msfc2-jsv-mz.121-4.E1. o what is the difference between these images c6msfc2-jsv-mz.121-4.E1 and  c6msfc-boot-mz.121-4.E1.

View 5 Replies View Related

Cisco Switching/Routing :: IE3000 Sw Cannot Load Boot Image

May 13, 2013

I'm having difficult getting this switch to boot from flash. I do not understand why it is trying to load "b1" from "bs1" instead of something from flash. [code]

View 2 Replies View Related

Cisco Switching/Routing :: WS-C6509-E - Possible To Boot IOS From TFTP Server

Oct 21, 2012

I have been looking at grading the IOS version on our 6509-E however there is not enough space on disk:0 to upgrade to the version I need to install. The question I would like to ask is - is it possible to boot the IOS from a TFTP server? If this is possible what configuration do I need on the 6509 to enable this. How does the 6509 know about the TFTP server as an IOS is not installed and therefore it will not have a network configuration

View 2 Replies View Related

Cisco Switching/Routing :: 2960S Boot Loader And IOS Image

May 18, 2013

after upgrading IOS image to V15 on four 2960S switches: Should I make the boot loader image to match the IOS version?I never thought about this while upgrading IOS image unless there is boot issue. I googled for answer but no luck there...
 
I checked download section on Cisco.com for C2960S-48FPS-L switch and there is simply no boot loader image..The running boot loader is C2960S-HBOOT-M Version 12.2(55r)SEThe running IOS is: 15.0 (2) SE2.

View 7 Replies View Related

Cisco Switching/Routing :: Error But Successful Boot On C3750E

May 31, 2012

I have a C3750E-24TD-S on which I just loaded new firmware.  When I boot up I see this:Loading "c3750e-universalk9-mz.150-1.SE2.bin"...c3750e-universalk9-mz.150-1.SE2.bin: no such device
 
Error loading "c3750e-universalk9-mz.150-1.SE2.bin"
 
Interrupt within 5 seconds to abort boot process. Loading "flash:/c3750e-universalk9-mz.150-1.SE2.bin".

View 13 Replies View Related

Cisco Switching/Routing :: WS-C3524-PWR-xl Boot Permission Error?

Jul 19, 2012

I am in the process of updating the software on a Catalyst 3500 series switch.  I deleted the old bin file and copied over the new file via xmodem.the image I used is:
 
 c3500xl-c3h2s-mz.120-5.WC17.bin
 
Once the xmodem copy is complete I performed the following sequence of steps:
 
File "xmodem:c3500xl-c3h2s-mz.120-5.WC17.bin" successfully copied to "flash:c350
0xl-c3h2s-mz.120-5.WC17.bin"
switch: dir flash:
Directory of flash:/

[code]....

The last output is where I am stuck.   What am I missing?

View 2 Replies View Related

Cisco Switching/Routing :: Boot Flash Error On 3524XL

Feb 26, 2012

Every time I delete the directory flash and reinstall it, I get an error:

Error loading "flash:c2950-i6q4l2-mz.121-12c.EA1.bin" 
Error loading "flash:c2950-i6q4l2-mz.121-12c.EA1.bin" Interrupt within 5 seconds to abort boot process. 

That is the message I get. It's set to NO manual boot, but it keeps making me manually boot it. I am at a loss, I've done 3 switches and they all keep doing the same thing.

View 6 Replies View Related