Cisco Switching/Routing :: Catalyst 6500 Boot Process?

Mar 19, 2013

document which explians normal booting sequence in a 6500 Switch running IOS. What I am looking for is in which order the image is loaded in SUP, RP, SP etc

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Catalyst 6500 - Crash Due To Pid 234 - Process ACE HAPI

Jun 29, 2012

I want to know what is this process used for on a catalyst 6500 ? we have got following message in the crash file, probably due to CSCsv77354
  
Jun 30 16:06:47.099 UAE: %SYS-6-STACKLOW: Stack for process ACE HAPI running low, 0/6000

View 3 Replies View Related

Cisco Switching/Routing :: 6500 ISSU Process Is In Progress

Apr 15, 2013

We are looking to upgrade the version of IOS on the 6500s this evening and in preparation i've dowloaded the image to sup-bootdisk.  However when trying to update the boot path as follows I see the following error: [code] Why are we seeing this message when the router is not doing anything with ISSU?

View 3 Replies View Related

Cisco Switching/Routing :: Pm Scp Process 100% And Switch 6500-E Crash?

Oct 24, 2012

The switch 6500-E is frequently crashing whenever the pm scp process reach 100% .I got it under the  command "remote command switch show proce cpu".How to solve the problem. I opened the TAC and the engineer says to upgrade the image12.2(18) sxf.Is there any other work around that would avoid to reimage the switch and reloading.

View 1 Replies View Related

Cisco Switching/Routing :: 6500 / Nexus OSPF Process Limit?

Jan 11, 2012

We are cutting over from 6500 IOS to Nexus 7000 and have hit "Maximum ospf feature instance limit reached." as we configured up the 7 existing ospf processes - the limit is 4. These existing processes are for various vrf contexts we have. I see you can run multiple vrf contexts under one process - but how does that work in a mixed environment where the ospf neighbours are still ios 6500s? They still expect to see different ospf process id per vrf.

View 2 Replies View Related

Cisco Switching/Routing :: 6500-E VSS High CPU Utilization Process IOS-Base

Apr 18, 2012

we are using Cisco 6509-E VSS mode [12.2(33)SXI] ipbase image and facing high cpu utilization. In show process cpu output it is showing some "ios-base" process consuming cpu.  I attached show cpu output

View 1 Replies View Related

Cisco Switching/Routing :: 6500 - SSH Control Process / Private Key Not Found

Nov 30, 2012

we have configured SSh on our primary and secondry core switch , SSH is working on primary Switch but we are unabme to access secondry Core switch through SSH .
 
Error are as under :
 
ov 28 09:14:15.380: SSH1: starting SSH control process
ov 28 09:14:15.380: SSH1: sent protocol version id SSH-2.0-Cisco-1.25
ov 28 09:14:15.396: SSH1: protocol version id is - SSH-2.0-PuTTY_Release_0.62
ov 28 09:14:15.396: SSH2 1: send: len 280 (includes padlen 4)
ov 28 09:14:15.400: SSH2 1: SSH2_MSG_KEXINIT sent

[code]...

View 1 Replies View Related

Cisco Switching/Routing :: 6500 How Long Conversion Process Takes Place

Dec 5, 2012

We will be converting two 6500s to VSS. Each chassis has a Sup2T module, fwsm, 6908-10G blade, wism1 blades and two or three 6748-SFP blades. I was wondering how long the conversion process takes?  If I remember correctly at the 2012 networkers lab it took maybe 10 minutes while using Sup720s.  The instructor mentioned that with Sup2Ts it would convert a lot faster.

View 3 Replies View Related

Cisco Switching/Routing :: Process Of Swapping Out Older 24 Port Catalyst 3525 POE

Mar 6, 2013

I am in the process of swapping out an older 24 port Cisco catalyst 3525 POE switch running IOS 12.0(5) with a 48 port POE catalyst 3560 running ios 12.2(50)The trunk port on the older switch (that currently works) is in port Gig0/1 with as basic of a trunk config as you might find.

In the newer switch I have a 1000BaseSX SFP min gbic with a SC-LC fiber cable attached (8.3/125 – 15 meter.When I make the connections, I get no lights… no connection.

View 7 Replies View Related

Cisco Switching/Routing :: Catalyst 3750 Won't Boot

Apr 9, 2013

my Catalyst 3750 switch. Following a power cut the switch no longer boots up. The SYST light flashed green but no POST checks are made. I cannot see any boot messages from the console port either. The switch was on a UPS but some thing may have damaged the switch.

View 7 Replies View Related

Cisco Switching/Routing :: 6500 Not Booting Neither From Boot Disk

Jul 23, 2012

One of the 6500 was going in bootrom mode,  so I have formated the flash disk using the other Cisco 6500 switch and copied IOS file to the  boot disk. But the 6500 booting failed.

View 6 Replies View Related

Cisco Switching/Routing :: 6500 Line Card Boot Order?

Nov 28, 2011

direct me to a document detailing the order that line cards are supposed to boot in a 6500? I'm noticing random boot sequences in some of my chassis,?Note: We currently run Sup720 3CXL for the most part.

View 6 Replies View Related

Cisco Switching/Routing :: Catalyst 2948G Boot Cannot Load Flash In Loop And No ROMmon

May 9, 2012

i have recently tried to change the catos on a Catalyst 2948G-L3 and since then i have the following message in a loop :I  know that the solution would be to download a new valid image from tftp  via the rommon prompt but what i dont undertand is why i cant access  the rommon prompt. It justs boots with the message above in a loop

View 0 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 - DAI Configuration

Apr 26, 2012

Any step-by-step configuration guide of how to enable DAI on Cisco Catalyst 6500 Series Switches.

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 / QoS For Supervisor 2T?

Apr 30, 2013

I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
 
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
 
[URL]
 
But I don't see anything for the new Supervisor 2T?

View 3 Replies View Related

Cisco Switching/Routing :: WOL Configuration On L3 Catalyst 6500 And L2 2960G?

Dec 20, 2011

I got problem with wake on LAN software.. The software unable to ON all pc's remotely if sitting under different vlan. Everything is ok if using the same vlan. Below are the network diagram & switch configuration.
 
Layer 3 switch Intervlan routing configuration
  
ip forward-protocol udp 7
!
interface Vlan4
description vlan Client-WOL
ip address 172.22.51.253 255.255.254.0
ip access-group Deny_HTTP_Vlan1 in
ip helper-address 172.20.1.246

[code].....
 
After configured all the switches with the above setting, the software still cannot wake all the pc's using LAN. Base on sniffing, i can't find UDP port usage by the software. Attached here with print screen from wireshark.

View 7 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Dual-Supervisor 720-10G-3C?

Sep 21, 2012

1. We now have SupA & SupB in the chassis, due to some mistake we have same IOS version but different feature set on them, although we configured redundancy mode sso, in the "show redundancy" we see Operating Redundancy Mode = rpr due to Software mismat, we now need to fix them as same feature set image, if I use "copy sup-bootdisk0:/xxxx slavesup-bootdisk0:/xxx", then write memory, does this cause any service/network interuption?

Available system uptime = 1 year, 1 week, 4 days, 9 hours, 21 minutes
Switchovers system experienced = 2
Standby failures = 0
Last switchover reason = active unit removed

[code]....
 
2. We did a failover test with this status, found that if we triggered supervisor failover, all modules will reload thus the services if interupped. How about after we make the Operating Redundancy Mode as sso, will this behaviour shows again? Or a stateful failover will happens, then modules no need reload?
 
3. We are using OSPF as our L3 routing protocol, after reference to the configuration, nsf should be enabled, we want to ask in the OSPF-domain nsf should be configured in all OSPF-enabled router or only 6500 which have dual-sup?
 
4. We also found that the interfaces(3 * Gig & 2 * TenG) in Standby supervisor cannot be use even enabled & configured, is it because we are running rpr mode now or will be the same even change to sso? Before customer have some older supervisor in 6500 non-e chassis, and they can use the standby supervisor interfaces as traffic forwarding, they use rpr-plus mode before, how about in sso mode?

View 6 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 BUS EoBC Channel

May 5, 2013

"How to display the EOBC error counters in the Catalyst 6500 series switches and a definition of the EOBC interface" document here on support forum stays that The Ethernet Out of Band Channel (EOBC) is a  half duplex channel that services many functions, which include the  Simple Network Management Protocol (SNMP) and the packets that are  destined for the switch.
 
Previously i were thinking that EoBC used only for SCP  and SLP protocol. In addition i found other article (but not on cisco site, heh) where stays that The Results bus is a       control plane, while the C (EoBC) bus is more of an       "admin plane", thus you will never see data       packets (such as CDP, SNMP, etc.) going over the R or C bus.
 
So there is a big contradiction between those two statements. How to prove one of those and if first one right, what meaned under the packets that are  destined for the switch in it? SCP and SLP or other traffic as well?

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 VS-SUP2T-10G QoS Configuration

Apr 22, 2013

I am migrating services from SUP720-3B to VS-SUP2T-10G= and moving to a VSS configuration  between a pair of Cat6506 distribution layer switches. I need to enable QoS on these switches, primarily to trust dscp and also to prioritise voice traffic. The autoqos feature works for some ports but does not work on port-channel interfaces and port-channel member interfaces. How can I apply the qos settings for these interfaces in line with what auto qos would normally provide. My line cards are as follows:
 
Civic_6506VSS#sho mod
Mod Ports Card Type                              Model              Serial No.
--- ----- -------------------------------------- ------------------ -----------
1    4  CEF720 4 port 10-Gigabit Ethernet      WS-X6704-10GE   

[Code].....

View 1 Replies View Related

Cisco Switching/Routing :: VPC On Nexus 5000 With Catalyst 6500 (no VSS)?

Jan 23, 2011

The diagram below is the configuration we are looking to deploy, that way because we do not have VSS on the 6500 switches so we can not create only one  Etherchannel to the 6500s.Our blades inserted on the UCS chassis  have INTEL dual port cards, so they do not support full failover.
 
Questions I have are.

- Is this my best deployment choice?
- vPC highly depend on the management interface on the Nexus 5000 for the keep alive peer monitoring, so what is going to happen if the vPC brakes due to:
- one of the 6500 goes down
- STP?
- What is going to happend with the Etherchannels on the remaining  6500?
- the Management interface goes down for any other reason
- which one is going to be the primary NEXUS?
 
Below is the list of devices involved and the configuration for the Nexus 5000 and 65000. 
 
Devices

·         2  Cisco Catalyst with two WS-SUP720-3B each (no VSS)
·         2 Cisco Nexus 5010
·         2 Cisco UCS 6120xp
·         2 UCS Chassis
     -    4  Cisco  B200-M1 blades (2 each chassis)
          - Dual 10Gb Intel card (1 per blade)
 
vPC Configuration on Nexus 5000
 
TACSWN01
TACSWN02
feature vpc
vpc domain 5
reload restore
reload restore   delay 300

[code]...

View 22 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 Or 6500 VSS Capabilities?

Dec 10, 2012

Catalyst 4500 or 6500 VSS Capabilities?

View 6 Replies View Related

Cisco Switching/Routing :: 6500 - FTTx (FTTB) On Catalyst?

Dec 15, 2011

Its possible FTTx on a 6500 ?

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Switch Architecture

Jul 16, 2012

one of the most widely deployed switches in the world. The "Swiss Army knife of network", can do routing, switching, security, wireless and almost everything that you would want your core switch to do. Remember to use the rating system to let Akshay know if you have received an adequate response. 
 
Akshay might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Network Infrastructure sub-community LAN, Switching and Routing discussion forum shortly after the event.  This event lasts through July 27, 2012. Visit this forum often to view responses to your questions and the questions of other community members.

View 22 Replies View Related

Cisco Switching/Routing :: 4506E Any Free CPU Process Monitoring Tools To Identify Which Process Is Spiking

Oct 9, 2012

I have two core switches - 4506E, and i noticed there are frequent cpu spikes on both of the cores switches. As its spikes intermitendly i couldnt able to anlyze the issue. I need inputs on the following,
 
1) Is there any Free CPU process monitoring tools to identify which process is spiking ?

2) Troubleshooting techniques to identify the issue.

View 1 Replies View Related

Cisco Switching/Routing :: How To Identify Modules Supported By Catalyst 6500

Nov 15, 2011

how to identify which modules are supported by cisco catalyst 6500. is there any OID which can give us the information

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Update And HTTP Server?

Mar 24, 2013

cisco WS-C6509-E Core switch with IOS  "s72033-ipservicesk9_wan-mz.122-18.SXF11"
 
i have 2 question 
 
Q.1 i want to upgrade this switch what is the latest IOS ver. supported by this module ?
 
Q.2  i need to enable http server on this switch when i run this comman it's accsebt but i cant get http work

View 1 Replies View Related

Cisco Switching/Routing :: To Issue Eigrp Leaking Routes On Catalyst 6500

Mar 26, 2012

Is it possible to issue eigrp leaking routes on catalyst 6500 running IOS 12.2-33SXI9 on gigabitethernet interfaces? or is there another way to acomplish this?

View 10 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 / Port-Channel Down But Correctly Configured

May 23, 2012

I has a issue about etherchannel beetwen 02 Catalyst 6500 switch, i need your comment about it. if you had any similar experience:
 
1.- On Catalyst Switch 6500-1:   I configured interface port-channel 4 and associated it to G6/29 and G6/30 interface Port-channel4description IUU1_Gn1_HLIMSGSN01_Port_channel_6_29_6_30switchportswitchport trunk encapsulation dot1qswitchport trunk allowed vlan 406,408switchport mode trunkswitchport nonegotiatelogging event link-statusload-interval 30mls qos vlan-basedmls qos trust dscp!

2.- On Catalyst Switch 6500-2:  I configured interface port-channel 4 and associated it to G6/29 and G6/30
 
interface Port-channel4
description IUU2_Gn2_HLIMSGSN01_Port_channel_6_29_6_30
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 407,409

[code]....
 
and i see output "show interface Po4A" up up on switch-1, "show interface Po4B" up up on switch-2   
 
5.- In the show running-config not appear configured Po4A and Po4B. it only show on outputs
 
6.- Po4A and Po4 was not configured on neither switches, my question is why appear Po4A and Po4B on switch-1 and switch-2 respectively?  and why Po4 appear in down down.
 
7.- I solved this issue by shutdown and not shutdown to the interfaces on both routers, currently all is OK.

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 - Netflow Table Utilization Logs

Nov 27, 2011

We are getting log messages like

%EARL-DFC4-4-NF_USAGE: Current Netflow Table Utilization is 95%
%EARL-DFC4-4-NF_USAGE: Current Netflow Table Utilization is 99%
 
What this messages really means and how to get rid of these messages. We are using IOS version 12.2(33)SXJ in Catalyst 6500.

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Supervisors Differences Sup1A Vs Sup32

Feb 16, 2012

I understand that my questions seems to be rather strange cos supervisors is rather old (Sup1A especially). But i am interested in understanding what puprpose were in production SUP32. I cant find out enough differencies between Sup1A with MSFC2 and Sup32 to understand what reasons lead to deploying new sup in none fabric supervisor series.

Both supervisors have same perfomance - 15Mpps and have limitation on backplane bandwith of 32 Gbps (cos both use swithing bus), both supervisors equipped with MSFC2 and etc. Differencies i found:

SUP 32 have 10Gbe ports support (but this seems to be doubtful enhancement -  with it perfomance GE ports seems to be more appropriate technology isnt it?) SUP1A equipped with PFC, SUP32 with PFC3BSUP32 deploys CEF (what is benefit of CEF if perfomance same?) 

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 - Cannot See Return Traffic On SPAN Session?

Jan 31, 2012

On a Catalyst 6500, we configured a SPAN session with VLAN 300 as a source. We configured the session bi-directional ("both" keyword). We connect a sniffer on the SPAN destination port.
 
Strangely enough, we only see the traffic from the VRF to the firewall, but not the reverse traffic ! What can be the problem ?

View 2 Replies View Related

Cisco Routing :: Catalyst 6500 / 4500 - Preventative Maintenance On Catalyst Chassis Switches?

Jun 4, 2013

Are there any best practices for preventative maintenance on Catalyst Chassis switches.  Looking to build a PMI schedule for a customer.  Or is there evidence not to perform it at all.  Things like re-seating line cards, cleaning fan exhausts, etc. 

View 1 Replies View Related

Cisco Switching/Routing :: Does Supervisor 720 Support All Existing Catalyst 6500 Series Interface

Feb 12, 2013

Q. Does the Supervisor 720 support all existing Cisco Catalyst 6500 series  interface and services module, protecting customer investments?

View 1 Replies View Related