Cisco Switching/Routing :: Process Of Swapping Out Older 24 Port Catalyst 3525 POE
Mar 6, 2013
I am in the process of swapping out an older 24 port Cisco catalyst 3525 POE switch running IOS 12.0(5) with a 48 port POE catalyst 3560 running ios 12.2(50)The trunk port on the older switch (that currently works) is in port Gig0/1 with as basic of a trunk config as you might find.
In the newer switch I have a 1000BaseSX SFP min gbic with a SC-LC fiber cable attached (8.3/125 – 15 meter.When I make the connections, I get no lights… no connection.
View 7 Replies
ADVERTISEMENT
Mar 19, 2013
document which explians normal booting sequence in a 6500 Switch running IOS. What I am looking for is in which order the image is loaded in SUP, RP, SP etc
View 1 Replies
View Related
Jun 29, 2012
I want to know what is this process used for on a catalyst 6500 ? we have got following message in the crash file, probably due to CSCsv77354
Jun 30 16:06:47.099 UAE: %SYS-6-STACKLOW: Stack for process ACE HAPI running low, 0/6000
View 3 Replies
View Related
Oct 9, 2012
I have two core switches - 4506E, and i noticed there are frequent cpu spikes on both of the cores switches. As its spikes intermitendly i couldnt able to anlyze the issue. I need inputs on the following,
1) Is there any Free CPU process monitoring tools to identify which process is spiking ?
2) Troubleshooting techniques to identify the issue.
View 1 Replies
View Related
Sep 30, 2012
The school I work at upgraded to Cisco Catalyst 2960-S switches, all connected to each other via fiber. I am seeing a problem with one such connection. Cisco Network Assistant showed a "4-Warning" regarding the fiber link port: port was disabled because it was fluctuating between up and down too rapidly. Possible hardware problem, resolve and re-enable. (I'm paraphasing the message...it was 'acknowledged', and I can't bring it back up.)
This message was only showing on our "SV-Copy-Rm" switch's port 49. The other end, on "SV-Maint-Rm" port 49 showed a normal green link status.
Using Internet Explorer, I logged onto SV-Copy-Rm switch's Device Manager, and I first tried disabling/re-enabling port 49 on SV-Copy-Rm. It came back up blinking yellow and showing "port has bad link" when I cursor hovered over port 49. This continued for a few minutes, followed by port 49 being disabled again.
The current thing I'm trying is swapping the connection on both ends to a spare pair of fibers. I'm pretty certain I've swapped to the same pair on both ends, however, now neither switch shows an active link. I've disabled/enabled the ports on both ends, but still no link.
Question: How do I re-establish the above link? (The active connection has 'fallen back' to the designated ethernet Cat 5e connection and is currently running with that connection.)
View 1 Replies
View Related
Mar 18, 2013
I have Catalyst 2960 S (WS-C2960S-48FPS-L) Switch. I have plugged in SFP module but still interface is down and line protocol down. Is there any configuration to enable SFP module and make the interface up?
This port is connected to nexus 5 k.
View 11 Replies
View Related
Sep 3, 2008
I have a 892 router configured on fa0 with vlan1 and a catalist 3560. On catalist all ports are in access mode and vlan1. When I'm connecting port fa0 from router to catalist, the catalist port is shuted down What should I do on router on catalist to make the connection working ?
View 4 Replies
View Related
May 22, 2012
We have two catalyst 3560X 24T-S switches connected on two separate LANs (both the networks are redundant to each other). The last port of the switches are connected together?
View 15 Replies
View Related
Oct 21, 2012
I've just installed 2 of these in my workplace on a PLC network.I'm now looking to set one of the ports up as my diagnostic port and would like to be able to mirror any of the other ports to this port.I believe it is called SPAN on Cisco switches.The only reference I can find to it is configuring via Telnet which I haven't got a clue about.On my old Wiedmuller switches it was just a few clicks away.
View 3 Replies
View Related
Jun 12, 2013
I am connecting two catalyst 3500 XL switches via fiber fx ports for layer 2 connectivity. Do I need to configure anything in the IOS or do I just plug in the fiber?
What needs to be configured?
View 2 Replies
View Related
Apr 10, 2012
Assume I had Catalyst 3560X/3750X with 24 ports. The partnumber is WS-C3560X-24P-LI would like to how is the numbering defined if the switches have a C3KX-NM-10G installed with 4 SFP-GE-L.
View 1 Replies
View Related
Mar 27, 2013
On 45XX catalyst , bandwidth is allocated across six 8-port groups, providing 1 Gbps per port group. Example for the following line card : WS-X4448-GB-SFP
I want to know if there is the same mecanism on 3750X switches. I mean is bandwidth allocated across a group of ports like on 4500 catalyst ?
View 5 Replies
View Related
Nov 5, 2011
We are using catalyst 2960S Lan Base IOS on Radio towers. We just bought 50 Accest points, thas are GPS synchronized. Problem is the APs need to be connected on L2-mac betwen each other. But at this time we are using port isolation on each switch (tower) by protected port function to isolate clients from each other.
My question is, is possible to specifi a Mac addresses in specific vlan thats can comunicate betwen protected ports? On tower is one Master unit and others are slave. I thing there is only 1 dirrection comunication - from master to slave.
View 2 Replies
View Related
Sep 18, 2012
I want to configure switch port bandwidth limit for my Catalyst 2960-48, is there any hardware / ios limitation? can I configure it at all 48 switch ports?
View 1 Replies
View Related
Oct 26, 2011
Im trying to follow along documentation i see via train single videos and some online resources. I am trying to enable port security.I have a Catalyst 3546 XL when i type in "rtr1# switchport ?""port-security" is not only of the options to choose from. I have already set this as an access port.
View 4 Replies
View Related
Nov 5, 2012
Im trying to access the switch to reset the password to factory defaults (please see switch output Astrix has removed customer identifying information for security purposes.) Each time I reboot the switch and try and access the password recover mode this same output below starts and im still not able to access the recovery area of the switch
cisco WS-C3560G-48PS (PowerPC405) processor (revision F0) with 122880K/8184K bytes of memory.
Processor board ID FOC1133Y28Q
[Code].....
View 3 Replies
View Related
May 23, 2012
I has a issue about etherchannel beetwen 02 Catalyst 6500 switch, i need your comment about it. if you had any similar experience:
1.- On Catalyst Switch 6500-1: I configured interface port-channel 4 and associated it to G6/29 and G6/30 interface Port-channel4description IUU1_Gn1_HLIMSGSN01_Port_channel_6_29_6_30switchportswitchport trunk encapsulation dot1qswitchport trunk allowed vlan 406,408switchport mode trunkswitchport nonegotiatelogging event link-statusload-interval 30mls qos vlan-basedmls qos trust dscp!
2.- On Catalyst Switch 6500-2: I configured interface port-channel 4 and associated it to G6/29 and G6/30
interface Port-channel4
description IUU2_Gn2_HLIMSGSN01_Port_channel_6_29_6_30
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 407,409
[code]....
and i see output "show interface Po4A" up up on switch-1, "show interface Po4B" up up on switch-2
5.- In the show running-config not appear configured Po4A and Po4B. it only show on outputs
6.- Po4A and Po4 was not configured on neither switches, my question is why appear Po4A and Po4B on switch-1 and switch-2 respectively? and why Po4 appear in down down.
7.- I solved this issue by shutdown and not shutdown to the interfaces on both routers, currently all is OK.
View 4 Replies
View Related
Sep 27, 2012
I just bought a Catalyst 2960S to test out the feature "Port-Based Address Allocation" which is required for our factory. I followed the instruction from Cisco IOS and did all the steps but I could not get it to work, my network client did not received the expected IP address that I configured.
View 8 Replies
View Related
Oct 2, 2012
I have connected a 10BaseT device to a CISCO Catalyst 3560xPOE switch with dynamic port security. All seems to work fine when the distance between the two devices is closer then 200ft. When I connect to 10BaseT devices farther out near 300ft the response from the attached device is lost. It works ok on unmanaged switches at the longer distance. Is there a minimum response time from attached devices for dynamic port security to work properly? Is there any other explanation why it would work on cheaper switches, but not on the Port Secured Switch?
View 2 Replies
View Related
Sep 4, 2012
We have a core switch with the following ios and supervisor engine. Can we add a16 port LR (x2)or LRM(X2) ON the core switch?if not what modifications has to be done?if an ios upgrade is necessary is it a costly affair?At present we have two 1gb up link modules in single and multimode fiber .
#sh moduleMod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ ----------- 1 16 SFM-capable 16 port 1000mb GBIC WS-X6516A-GBIC SAL0803T308 2 48 SFM-capable 48 port 10/100/1000mb RJ45 WS-X6548-GE-TX SAD07500600 5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1439UMZK
#sh versionCisco IOS Software, s72033_rp Software (s72033_rp-IPBASE-M), Version 12.2(33)SXI4a, RELEASE SOFTWARE (fc2)Technical Support: [URL] Copyright (c) 1986-2010 by Cisco Systems, Inc.Compiled Fri 16-Jul-10 19:51 by prod_rel_team
ROM: System Bootstrap, Version 12.2(17r)SX7, RELEASE SOFTWARE (fc1) uptime is 1 year, 27 weeks, 4 days, 23 hours, 30 minutesUptime for this control processor is 1 year, 27 weeks, 4 days, 22 hours, 58 minutes(code)
View 6 Replies
View Related
Sep 1, 2007
Can we force the Gigabit Ethernet port to be 1000 full duplex in Cisco Catalyst Express 500 series?
View 3 Replies
View Related
Jan 10, 2013
I want upgrade IOS on my 7206VXR from 12.4(12c) to 15.1(4)M5 , but the CF card only 64M.
-NAME: "disk2", DESCR: "64MB Compact Flash Disk for NPE-G1"
-Router#show bootvar
BOOT variable = disk2:c7200-jk9s-mz.124-12c.bin,15.1(4)M5 is almost 40M. So there is not enough space.I want to ask is it ok if I upgrade with normal precedure , With the command " copy tftp: disk2: " ?Does the router will automatically delete the older IOS first and then copy into the new one ? Or Is there something I should pay attention first ?
View 3 Replies
View Related
Jan 13, 2012
I have a number of existing 4506 chassis type switches (the older non -E version) that I would like to roll out IP phones to. Instead of replacing the entire chassis, I would like to just replace the line cards in the switches with WS-X4548-GB-RJ45V. What or how much power supplies should I have in each switch to be able to power the 5 poe line cards (each port per line card will power an ip phone)?
View 6 Replies
View Related
Mar 7, 2012
I am looking into the possibility of using private vlan's for some dmz implementations however I do have what may be some very rudimentary questions. It seems straightforward how to configure the primary/secondary vlan configuration as well as associating them. However in my case I would be looking to configure the PVLAN on a 6500-vss platform acting as the router while all of the hosts which I would desire to have in the isolated vlan would be spread out across a number of older Cisco switches which only support "protected port" setup or Procurve switches all of which I do not have budget to replace with something newer. So in my scenario I would have a 6500 connected by trunk to multiple switches which only support a protected port setup such as a Procurve (top of rack) or a Cisco 2950. As the Procurve or 2950 would not support Private VLAN setup, do I then just configure the secondary vlan to be allowed across the trunk from the 6500, configure that vlan on the Procurve or 2950 (as vtp will not foward the info for the secondary vlan) and assign that vlan to the host port as well as setting it as a protected port and this will communicate just fine across the trunk to the router as well as stopping the protected port in top of rack switch 1 from being able to communicate to a protected port in top of rack 2,3,etc? If the above scenario is what needs to be done, do I just use a regular trunk or do I have to use a PVLAN trunk?
View 2 Replies
View Related
Jul 4, 2012
We are in the process of switching our infrastructure of our routing/firewalls/vpns over to cisco. We are switching our first location and one of the issues I'm struggling with is windows authentication pass-through for internally hosted web pages. Meaning, user inside our network has the 2921 as their default gateway, they try to access a web page that is hosted on the internal network but is secured with windows authentication. In the past, because they are logged into the domain internally, the website authenticates and loads. After switching to the Cisco, it asks for a password even though they are logged in.
Because its the web server that actually authenticates I'm not sure why the router isn't allowing that to happen, but I can't think of anything else that could be causing this behavior.
View 4 Replies
View Related
Mar 28, 2012
I have a Catalyst Switch 6000. Inoticed that after the execution of the job inventory in LMS, and after the snmp queries reached the equipement, the cpu value reached 98-99 % due to the process : PDU DISPATCHER (what’s it ?)
I have also a script running in the switch to observe the differents logs. For exemple, when high cpu is obtained, the message bellow appear :
« %SNMP-3-INPUT_QFULL_ERR: Packet dropped due to input
« %SNMP-3-INPUT_QFULL_ERR: Packet dropped due to input
« %SNMP-3-INPUT_QFULL_ERR: Packet dropped due to input
....
View 1 Replies
View Related
May 29, 2012
I have a process whick take all the CPU on two differents Stack of WS-C3750G in version 12.2.53(SE2):
XFRPALSN02R#sh proc cpu sorted CPU utilization for five seconds: 97%/3%; one minute: 95%; five minutes: 95% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 307 5450059 4167397 1307 86.74% 83.63% 83.35% 0 hulc nrgyz PD di XFRPALSN02R#sh proc cpu sorted CPU utilization for five seconds: 96%/3%; one minute: 96%; five minutes: 96% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 307 7779608 5947379 1308 86.26% 85.75% 85.30% 0 hulc nrgyz PD di
View 2 Replies
View Related
Oct 9, 2011
i try newest ios 15.1(3)S0a and 12.2(33)SRE
in both case some times i obtain lowing traffic on interface and highest cpu - to 100%
after clear cef linicard i obtain growing traffic and cpu 0%
#sh proc cpu s
CPU utilization for five seconds: 87%/83%; one minute: 91%; five minutes: 96%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
7 1711512 87883 19474 4.06% 0.84% 0.89% 0 Check heaps
[Code].....
View 18 Replies
View Related
Feb 24, 2009
We are following the ISSU process for upgading a VSS 1440, using the documentation here: URL
After copying image onto both supervisors, when the command:
issu loadversion sup-bootdisk:s72033-adventerprisek9_wan-mz.122-33.SXI.bin is run we get the following error:
% CV [ bootdisk:s72033-advipservicesk9_wan-mz.122-33.SXI.bin ] must be named first in BOOT [ bootdisk:s72033-adventerprisek9_wan-mz.122-33.SXI.bin ]
The advipservice image is the one running, and the adventerprise is the one we are trying to upgrade to.
View 9 Replies
View Related
Feb 17, 2011
I have an old Cabletron switch i have used for about 8-10 years, it has some vlans set up and i was wondering how i can "talk" to the switch and set it up. I am using this switch in my home on my vast network. is it possible to "reset to factory" or anything without a serial cable? I would like to use snmp of telnet to configure but i dont think it has an ip set up and it is such an old switch I cannot find any info from entrasys.
View 1 Replies
View Related
Jun 4, 2012
Our switch is very high cpu in process arp
Am debug ip arp track command the result as below
-- on this switch have interface vlan 201 ip subnet is 10.11.201.1/24
Jun 5 15:30:40.732 GMT+7: IP ARP: rcvd req src 10.11.201.217 0001.6c6b.8ab9, dst 172.27.116.73 Vlan201
Jun 5 15:30:42.150 GMT+7: IP ARP: rcvd rep src 10.11.201.217 0001.6c6b.8ab9, dst 172.27.116.4 Vlan201
Jun 5 15:30:42.150 GMT+7: IPARP_TRACK: ARP tableid(0) 10.11.201.217 Vlan201 mode(1) modified.
Jun 5 15:30:42.150 GMT+7: IP ARP: rcvd req src 10.11.201.217 0001.6c6b.8ab9, dst 172.27.116
and then am try to shutdown vlan database 201 after that the cpu process has to normal state.
How to check the root cacus?
View 1 Replies
View Related
Nov 29, 2011
I have a router 3845 with c3845-advsecurityk9-mz.124-24.T6.bin software . Frequently we are facing problem in logging to the device .Inorder to resolve we need to reboot the router . Yesterday fortunately i have got the console access for some time so i came to know that TPLUS process is consuming 99.9% percentage cpu.
View 1 Replies
View Related
Jan 2, 2012
I've been reading the documentation for the new 3750v2 switch, and I'm wondering is the IPBase license supports FULL OSPF. The product sheet notes that it supports OSPF in the IPBase license, but then further down the page it notes that for advanced routing functions (EIGRP,OSPF) you need the IPServices license. Are there any limitations to the OSPF process on a 3750v2 with the IPBase license?
View 3 Replies
View Related