Cisco Switching/Routing :: Does Supervisor 720 Support All Existing Catalyst 6500 Series Interface

Feb 12, 2013

Q. Does the Supervisor 720 support all existing Cisco Catalyst 6500 series  interface and services module, protecting customer investments?

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Catalyst 6500 / QoS For Supervisor 2T?

Apr 30, 2013

I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
 
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
 
[URL]
 
But I don't see anything for the new Supervisor 2T?

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Dual-Supervisor 720-10G-3C?

Sep 21, 2012

1. We now have SupA & SupB in the chassis, due to some mistake we have same IOS version but different feature set on them, although we configured redundancy mode sso, in the "show redundancy" we see Operating Redundancy Mode = rpr due to Software mismat, we now need to fix them as same feature set image, if I use "copy sup-bootdisk0:/xxxx slavesup-bootdisk0:/xxx", then write memory, does this cause any service/network interuption?

Available system uptime = 1 year, 1 week, 4 days, 9 hours, 21 minutes
Switchovers system experienced = 2
Standby failures = 0
Last switchover reason = active unit removed

[code]....
 
2. We did a failover test with this status, found that if we triggered supervisor failover, all modules will reload thus the services if interupped. How about after we make the Operating Redundancy Mode as sso, will this behaviour shows again? Or a stateful failover will happens, then modules no need reload?
 
3. We are using OSPF as our L3 routing protocol, after reference to the configuration, nsf should be enabled, we want to ask in the OSPF-domain nsf should be configured in all OSPF-enabled router or only 6500 which have dual-sup?
 
4. We also found that the interfaces(3 * Gig & 2 * TenG) in Standby supervisor cannot be use even enabled & configured, is it because we are running rpr mode now or will be the same even change to sso? Before customer have some older supervisor in 6500 non-e chassis, and they can use the standby supervisor interfaces as traffic forwarding, they use rpr-plus mode before, how about in sso mode?

View 6 Replies View Related

Cisco WAN :: 6500 Series Router Support Supervisor Module Redundancy Like 7304 Does

Jan 24, 2013

1) Does the 6500 series router support supervisor module redundancy like the 7304 does? IE, can I put two identical sup720 modules in the chassis for failover?

2) Can I use any ethernet interface on any line card on the 6500 series for router interfaces? If not, which line cards work as router interfaces?

3) Differences between the 6500 series and the 7600 series? Can I use a sup720 modules from a 6500 in a 7600?

View 4 Replies View Related

Cisco Switching/Routing :: Upgrading Catalyst 4500 Series Supervisor

Jan 8, 2012

Does a new Cisco Catalyst 4500 series supervisor 7L-E model WS-X45-SUP7L-E is backward compatible with a Cisco Catalyst 4500 series chassis model 4507R? I've checked on Cisco website for that Supervisor and it shows only new chassis models WS-C4507R+E and R-E, but what about old type of chassis? We need to upgrade that Supervisor as it's out of line, but we don't really want to buy a new chassis as well as it's going to be very pricy.

View 6 Replies View Related

Cisco WAN :: Catalyst 4500E - Any Supervisor With DECnet Routing Support?

Feb 8, 2011

Is there any sup for 4500E with DECnet routing support?

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Switch Support Multi-chassis EtherChannel Features?

Sep 26, 2012

I came across this Multichassis EtherChannel Features when read about information from Cisco Smart Business Architecture.After checking further, knowing that Cataly  stwitch 6500 supports this feature.provide information that beside Catalyst 6500, is there any other model of Catalyst switch can support this feature?

View 4 Replies View Related

Cisco WAN :: Catalyst 4500 E-Series Supervisor Engine 7L-E?

Aug 12, 2012

I have a strange issue with 4500 E chassis loaded with SUP 7L-E which always remains in ORANGE LED status, also the uplink ports interface is down and the line protocol is down  but when i execute the command sh int gig1/5 it show me the media type sfp but there is no red laser light seen in the sfp transiever,The below command is configured for the uplink gig port on the SUP engine.hw-module uplink select gigabitethernet?

View 10 Replies View Related

Cisco Infrastructure :: Supervisor Engine Catalyst 6500 Modular IOS?

Oct 11, 2011

I want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
  
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)

View 1 Replies View Related

Cisco WAN :: Functionality Difference In Supervisor Engine 2 / 2T For Catalyst 6500?

Aug 10, 2012

Is there functionality difference in Supervisor Engine 2 and Supervisor Engine 2T for Catalyst 6500 ?

View 3 Replies View Related

Cisco Switching/Routing :: 6500 What Happens When A Supervisor Fails

Feb 3, 2010

We've been mocking up a test lab to test VSS on two 6500's.  Each 6500 has one sup720 and a 6708-10ge blade and we've established the two 10ge links between the two chassis; the first from the each chassis' sup and the second from each 6708.My question is, what happens when the supervisor fails on one of the chassis?

View 10 Replies View Related

Cisco Switching/Routing :: QoS Catalyst 4500 7E Supervisor

Apr 15, 2012

I am trying to understand the implicit limit to the priority queue. I know you can define an explicit policer but if you don't I can't find out what the rate limit really is.

View 5 Replies View Related

Cisco Switching/Routing :: Catalyst 4510R+E Supervisor 7-E SSO Not Available

Sep 22, 2011

I'm working on deploying a new 4510R+E for our organization.  This is my first experience with a modular switch.  I'm trying to enable SSO, however in the redundancy configuration mode, the sso command is not available.  Is SSO only available with certain software images / licensing levels? [code]

View 2 Replies View Related

Cisco Switching/Routing :: Core 4500 Series Supervisor Engine?

Jun 19, 2012

Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst Supervisor 32 NVRAM Location?

Feb 10, 2013

I have a Sup32 that I suspect has faulty NVRAM (e.g., I am unable to "wr mem" on the device - it states resource is busy but no other active connections exist). Prior to replacing the supervisor engine I'd like to take a crack at formatting NVRAM to see if it resolves the issue. This supervisor does not have a CF card installed, thus no Disk0:. Within the CLI, I am presented two options with the "format" command - bootflash: and sup-bootflash:. Bootflash: does not have any data on it, however, sup-bootflash: contains my IOS image. I believe that both of these locations are simply directories within NVRAM.

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 4006 Supervisor Engine Led Red

Nov 28, 2011

we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]

View 1 Replies View Related

Cisco WAN :: VS Based 720 Supervisor As Minimum To Support Full BGP On Catalyst 6509-E

Nov 18, 2011

I'm currently in the process of evaluating potential equipment options for a Core Router/Switch that will be running BGP with several Tier 1 ISP's, the table download from each ISP will be full (300,000+ Routes). I was looking at a 6509-E with dual SUP720-3BXL supervisors but after reading the below link I'm a little concerned by the maximum routes table: [URL]
 
Do I have to go to the VS based 720 supervisor as a minimum to support full BGP on a 6509-E? Does any experience of the above switch + supervisor combination under a full BGP table, how well does it work? I'm looking at long term using this as a consolidated core (i.e. a VRF for the Global Internet routing table + a VRF for internal data center traffic, plus maybe some more shared VRF's).
 
Would I be better keeping a Core switch by itself and just buying edge routers to run BGP?

View 2 Replies View Related

Cisco Switching/Routing :: 6500 Redundant Supervisor Port Channel?

Oct 30, 2011

I have a Cisco 6500 series switch with VS-C6509E-S720-10G ,I have two redundant supervisors between two chassis on the LAN with no add-on line cards ?

I need to know if I can use the redundant supervisor 10 Gb uplinks to form a layer-2 Port channel between the two 6500 switches as i do not want to use want to keep the port idle additionally I need more bandwidth between the two switches for my server farm?

View 1 Replies View Related

Cisco Switching/Routing :: 6500 - Replace With Supervisor Modules CATOS?

Apr 22, 2012

I have a question. I have a 6500 with two supervosrs and they both have CATOS. One of them failed and I need to replace. As long as the hardware is the same does the CATOS have to be indentical or can this be different.

View 4 Replies View Related

Cisco Switching/Routing :: Configure Egress Netflow In 6500 (VSS) With VS-S720-10G Supervisor?

Jun 9, 2013

I'm trying to configure a egress netflow in a 6500 (VSS) with VS-S720-10G supervisor. I foud some old posts and understood that netflow wasn't supported on 6500 but i found a new document and it seems that netflow is supported in Supervisor Engine 2T:[URL] Does the netflow still not supported in VS-S720-10G? It's weird because the command is supported:
 
#sh run int vlan 4
Building configuration... 
Current configuration : 353 bytes
!
interface Vlan4
ip address X.X.X.X 255.255.0.0

[cod]....

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6509-E / Replace Supervisor Engine 720 10GE

May 15, 2012

we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario 

1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the  faulty VS-S720-10G from the slot 5
 
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?

View 3 Replies View Related

Cisco Switching/Routing :: Configuration Module Supervisor Switch Catalyst 4500

Jun 4, 2012

switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]

View 1 Replies View Related

Cisco Switching/Routing :: Multicast Traffic Not Forwarded On Catalyst 6506 VSS Supervisor

Nov 30, 2009

I have two Catalyst 6506 in VSS mode with VS-S720-10G running 12.2(33)SXI1 IP SERVICES.I have two firewalls that communicate on to the other through a dedicated VLAN created on Catalyst 6506.
 
One firewall is able to ping the other one on this dedicated VLAN but if I send multicast traffic from firewall-1 I didn't receive it on firewall-2.I found a bug related to multicast issues on Cisco WS-C6509-E with VS-S720-10G. The bug ID is CSCtc59038.

View 9 Replies View Related

Cisco Switching/Routing :: Match Protocol Command In Catalyst 4507R- Supervisor 7LE

Nov 28, 2012

My Company use Core Sw 4507R-Sup 7L-E with Enterprise Services License. I has upgraded to use iOS cat4500e-universal.SPA.03.03.01.SG.151-1.SG1.bin

When I use match protocol in class-map, there are only about 10 protocols, and not have those ones I need. I intend to expand the list of protocols to do some Policy-map by loading PDLM. But 4507 is no longer support NBAR. So do we have another way to set Catalyst 4507R with Sup 7L-E recongnize more protocols in match protocol command?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6513 - Redundant Supervisor Not Synced After Insertion

Aug 23, 2012

The SuperVisor engine in slot 1 of a Catalyst 6513 needed to be replaced because a hardware defect. The SuperVisor engine in slot 2 is active and running CatOS 8.5. The new SuperVisor engine for slot 1 came with CatOS 6.3 and was not syncronized auromatically after insertion. When the customer enter the command "Show boot" he get the output:
 
AG-A6513-51> (enable) sh boot
BOOT variable = bootflash:cat6000-sup2k8.8-5-5.bin,1;bootflash:cat6000-sup2k8.7-6-2.bin,1;

[Code].....

View 1 Replies View Related

Cisco Switching/Routing :: 6500 Redundant Supervisor Engine Will Forward Data While Is Standby

Oct 26, 2011

We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 4500E Supervisor Engine 7-E / Possible To Deploy Simultaneously Both Type Of Ports

Aug 8, 2012

We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
 
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 2960 / Add New Stack To Existing Two Stacks

Mar 7, 2013

On first floor, I have two stack switches and each stack has got 4 switches. they all are working fine.Now the client would like to add one more stack on the 2nd floor. But the second floor switches are different when compared to the 1st floor switches.
 
can you have differnt IOS among different stacks. I knew in a stack we need all the switches should have same IOS version. But in between two stacks to communicate do we need same IOS or they can be on differnet IOS?
 
1st floor switches have 15.0 version and 2nd floor new switches has 12.2.58. Is this ok ?
 
1st floor switches are 3500 series ( Note: only one one Vlan 20 we are using on the both stack switches and we would like add same Vlan 20 on to the new stack)
 
2nd floor switches aew 2 catalyst 2960 switches.
 
Note: on the second floor switches one is 24 port switch and the other one is 48 port switch. so can i make them  as a stack?
 
We have already done cabling from 1st floor to second floor. So no problem with that at all.

View 9 Replies View Related

Cisco Switching/Routing :: 6500 - Adding Port Channels In Existing STP Topology

Apr 3, 2013

current topology is build from 4 6500 switches connected in a ring topology. Using Port channel (2x 10Gbit) links to connect left side top and bottom 6500's (DC1), 10 G bit link to connect right side 6500's (DC2) In between a 1 G bit link is used to connect top 6500's (DC1-DC2) and the same for bottom 6500's (DC1-DC2). 

Path costs are 5 and 6 so the T5/4 from bottom right is blocking. Bandwidth demands are increasing, so thinking about adding extra 1 G bit links to the existing ones and create ether channels. Path costs here are 4 and 5, so T5/4 from bottom right is still blocking, but when the bottom 2 G bit port-channel is loosing one 1 G bit link the path costs of both directions become equal. So I am worried that STP will not re converge and leave me with a congested 1 G bit link. I cannot test this setup in a lab, are there any options for STP to re-converge here?

View 1 Replies View Related

Cisco Wireless :: Remove WiSM2 From Catalyst 6500 Series Switch?

Jul 21, 2012

how to safely remove the WiSM2 from the Catalyst 6500 series switch? According to the documentation "Catalyst 6500 Series Wireless Services Module 2 Installation and Verification Note":

To remove the WiSM2, perform these steps:

Step1     Shut down the module by one of these methods: In privileged mode from the router prompt, enter the hw-mod module mod shutdown command. NoteIf you enter this command to shut down the module, you must enter the following commands in global configuration mode to restart (power down, and then power up) the module: Router# no power enable module modRouter# power enable module mod If the module does not respond to any commands, press the SHUTDOWN button located on the front panel of the module.

Step2     Verify that the WiSM2 shuts down. Do not remove the module from the switch until the POWER LEDis off.

But, in the case of Step1 (1st methods) I do not see a option "shutdown"  in the command "hw-mod module 3"...

All I prompted to enter is: c6500#hw-module module 3 ?

boot   Specify boot options for the module through Power Management Bus control register

reset          Reset specified component

simulate  Simulate options for the module Is it hidden options?

IOS version of c6500 is 12.2(33)SXJ1
 
In the case of Step2 (2nd methods) there is not any button on the front panel of the module?
 
And yet, it is better to remove the module configuration manually or use the command module clear-config prior to removing the module?

View 14 Replies View Related

Cisco Switching/Routing :: IP Routing On 6500 Series Versus 3750?

Jan 24, 2013

For intervlan routing, Is 'IP routing' command enabled by default on a 6500 series switches based on the IOS?and on 3750 switches, do we need to enable the "ip routing" command manually for intervlan routing?

View 1 Replies View Related

Cisco Switching/Routing :: 6500 Series Switch - TCP Adjustment

Oct 14, 2012

I have a routed interface on a Cisco 6500 Series switch.  I am trying to find a way to adjust the tcp mss.To date I have not yet been able to find a way to accomplish this.  Is this just not supported?

View 3 Replies View Related

Cisco Switching/Routing :: Migration Of GLBP To VSS Between To 6500 Series SW

Jan 31, 2012

Is there a guide for a migration of the GLBP to VSS between to 6500 Series SW ?

View 1 Replies View Related