Cisco Switching/Routing :: 6500 - Replace With Supervisor Modules CATOS?
Apr 22, 2012
I have a question. I have a 6500 with two supervosrs and they both have CATOS. One of them failed and I need to replace. As long as the hardware is the same does the CATOS have to be indentical or can this be different.
View 4 Replies
ADVERTISEMENT
Nov 30, 2012
I need to replace a faulty fan unit on the catos WS-6509 switch. this Catos switch does not support show inventory so any other catos commands which will show me this part id?
View 2 Replies
View Related
Mar 6, 2012
I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.
View 1 Replies
View Related
Feb 10, 2013
We are implementing NAC in our environment and unfortunately still some of our obsolete 6500 switches are running CATOS, the current (cat6000-sup2cvk9.8-6-4.bin) image does not support some of the commands related to NAC implementation. Therefore, I would like to urge you to provide me the 8.7 image which supports all the NAC related commands and will be easier to finish the long pending assignment.
We are in process of replacing the obselete hardware but that will take time.
So, 8.7 K9 CATOS image required.
View 4 Replies
View Related
May 27, 2013
I am trying to Disable Telnet and enable SSH in CatOS for 6500 .
View 12 Replies
View Related
May 15, 2012
we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario
1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the faulty VS-S720-10G from the slot 5
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?
View 3 Replies
View Related
Jul 17, 2012
how to convert configuration catos on 6500 to IOS image.
View 3 Replies
View Related
Sep 17, 2012
Is it possible to implement LLQ(QoS) on ethernet modules in the Cat 6500? For this feature, I can only find documentation about ES+ modules or SPA/SIP modules! (according to the feature navigator LLQ is supporten on the concerning HW and SW image)
View 2 Replies
View Related
Mar 11, 2013
is there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies
View Related
Nov 16, 2011
I have problem with the standby supervisor in 6500 vss and need to replace the supervisor. I have follow how-to on the cisco web site url...
But when i boot the new standby sup720 it comes active and both supervisors is rebooting. I wonder if i can do the replacement without rebooting both active and standy supervisor.
View 1 Replies
View Related
Nov 15, 2011
how to identify which modules are supported by cisco catalyst 6500. is there any OID which can give us the information
View 2 Replies
View Related
Oct 21, 2012
I have been tasked to replace a failed sup on a 6500 Sup32 running IOS. Now, the primary sup doesnt have a compact flash. I don't have any CF on me. The replacement sup i received also doesnt have a CF.From the cisco website it says that the moment I insert the secondary sup into the chassis. it will automatically download the IOS and boot details from the primary to the secondary sup.
[code]....
View 1 Replies
View Related
Feb 3, 2010
We've been mocking up a test lab to test VSS on two 6500's. Each 6500 has one sup720 and a 6708-10ge blade and we've established the two 10ge links between the two chassis; the first from the each chassis' sup and the second from each 6708.My question is, what happens when the supervisor fails on one of the chassis?
View 10 Replies
View Related
Apr 30, 2013
I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
[URL]
But I don't see anything for the new Supervisor 2T?
View 3 Replies
View Related
Sep 21, 2012
1. We now have SupA & SupB in the chassis, due to some mistake we have same IOS version but different feature set on them, although we configured redundancy mode sso, in the "show redundancy" we see Operating Redundancy Mode = rpr due to Software mismat, we now need to fix them as same feature set image, if I use "copy sup-bootdisk0:/xxxx slavesup-bootdisk0:/xxx", then write memory, does this cause any service/network interuption?
Available system uptime = 1 year, 1 week, 4 days, 9 hours, 21 minutes
Switchovers system experienced = 2
Standby failures = 0
Last switchover reason = active unit removed
[code]....
2. We did a failover test with this status, found that if we triggered supervisor failover, all modules will reload thus the services if interupped. How about after we make the Operating Redundancy Mode as sso, will this behaviour shows again? Or a stateful failover will happens, then modules no need reload?
3. We are using OSPF as our L3 routing protocol, after reference to the configuration, nsf should be enabled, we want to ask in the OSPF-domain nsf should be configured in all OSPF-enabled router or only 6500 which have dual-sup?
4. We also found that the interfaces(3 * Gig & 2 * TenG) in Standby supervisor cannot be use even enabled & configured, is it because we are running rpr mode now or will be the same even change to sso? Before customer have some older supervisor in 6500 non-e chassis, and they can use the standby supervisor interfaces as traffic forwarding, they use rpr-plus mode before, how about in sso mode?
View 6 Replies
View Related
Oct 30, 2011
I have a Cisco 6500 series switch with VS-C6509E-S720-10G ,I have two redundant supervisors between two chassis on the LAN with no add-on line cards ?
I need to know if I can use the redundant supervisor 10 Gb uplinks to form a layer-2 Port channel between the two 6500 switches as i do not want to use want to keep the port idle additionally I need more bandwidth between the two switches for my server farm?
View 1 Replies
View Related
Jun 9, 2013
I'm trying to configure a egress netflow in a 6500 (VSS) with VS-S720-10G supervisor. I foud some old posts and understood that netflow wasn't supported on 6500 but i found a new document and it seems that netflow is supported in Supervisor Engine 2T:[URL] Does the netflow still not supported in VS-S720-10G? It's weird because the command is supported:
#sh run int vlan 4
Building configuration...
Current configuration : 353 bytes
!
interface Vlan4
ip address X.X.X.X 255.255.0.0
[cod]....
View 1 Replies
View Related
Feb 12, 2013
Q. Does the Supervisor 720 support all existing Cisco Catalyst 6500 series interface and services module, protecting customer investments?
View 1 Replies
View Related
Oct 26, 2011
We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?
View 4 Replies
View Related
Jul 31, 2012
I have a new 6513 with 2 sup32's with IOS. This chassis will replace a working 6513 with 2 sup2's with CatOS.I need to pull the running config from the CatOS chassis and make it work on the IOS chassis. i can do this manually but was wondering if there are any trade secrets on doing this.
View 3 Replies
View Related
Oct 24, 2012
I have a client who is changing their management IP scheme as a bridge to replacing equipment and much of the old equipment (Catalyst 4000) is running CatOS and I am a bit weak in CatOS. The existing Management IP is setup as follows:
set interface sc0 1 192.168.252.209/255.255.255.0 192.168.252.255
set ip route 0.0.0.0/0.0.0.0 192.168.252.1
What we want to change this to is as follows:
set interface sc0 110 192.168.197.209/255.255.255.0 192.168.197.255
set ip route 0.0.0.0/0.0.0.0 192.168.197.1
The devices are spreadout over a large area and visiting each device is almost out of the question due to a time deadline I was wondering if I run this set of commands will this allow me to keep a remote session (SSH) running until the change is complete?
set ip route 192.168.197.0/255.255.255.0 192.168.197.1
set interface sc0 110 192.168.197.209/255.255.255.0 192.168.197.255
set ip route 0.0.0.0/0.0.0.0 192.168.197.1
View 5 Replies
View Related
Nov 7, 2012
I have to upgrade two Cisco Catalyst 6509E from Catos to IOS. I would want to know the requirements hardware or software for upgrading. Which are the recommended images I must download? From cat6000-sup32pfc3k9.8-4-5 to the latest stable version of IOS, is it recomended to pass to another previously version before?
I have viewed the following links,[URL]but, it doesn`t mention anything about that. The image below is the result of the "show version" command of one of our Cisco Catalyst.
WS-C6509-E Software, Version NmpSW: 8.4(5)
Copyright (c) 1995-2005 by Cisco Systems
NMP S/W compiled on Aug 3 2005, 13:13:36
[code]....
View 2 Replies
View Related
Sep 26, 2012
I need to convert configuration from CatOS on 4006 to IOS on 4510. I am unable to find the conversion tool.
View 5 Replies
View Related
Nov 14, 2012
I am trying to find a command for dhcp snooping rate-limiting on a CatOS. The PFC card is PFC. PFC3B is said to support that command. But there seems no this command.
-6k> (enable) sh ver
WS-C6509-E Software, Version NmpSW: 8.4(5)
Copyright (c) 1995-2005 by Cisco Systems
NMP S/W compiled on Aug 3 2005, 13:26:46
[Code] ......
Up time is 1183 days, 1 hour, 41 minutes
View 3 Replies
View Related
Oct 14, 2012
I have a new 6513 with 2 sup32's with IOS. This chassis will replace a working 6513 with 2 sup2's with CatOS.I would like to convert my CatOS running configs to IOS, and I know there used to be a tool for this.
I have searched around and found many broken links to an old Cisco tool to convert my former configs, is there any way to get this tool today? I have tried over 20 links and not been able to find a working one yet.
View 2 Replies
View Related
May 15, 2013
I'm trying to configure an LACP channel trunk between a CatOS C6000 and a Dell PowerConnect.
I use mode active in both sides and it works great.
But, when I connect a Catalyst 3750X to the Dell PowerConnect the channel between C6000 and PWC shutdown:
2013 May 16 09:08:20 CEST +02:00 %SPANTREE-2-CHNMISCFG: STP loop - channel 5/19-20 is disabled in vlan/instance 20
2013 May 16 09:08:20 CEST +02:00 %SPANTREE-2-CHNMISCFG2: BPDU source mac addresses: 00-04-6d-43-a4-e2, 70-ca-9b-27-46-99
View 3 Replies
View Related
Oct 25, 2012
I am trying to find the serial number on the CLI that matches the serial number sticker on the back of a WS-C2948G-GE-TX switch that runs CatOS. I am running code cat4000-k9.8-3-2-GLX.bin. I have 4 different switches and all the stickers have a serial that starts with JPE.. and both "show version" and "show sprom 1" and "show sprom 2" gives me a completely different serial number that starts wtih JAE... All of these serial numbers I get from the CLI match with each other. The command "show sprom chassis" says "Feature not supported."
Is it possible to find the serial number that matches the sticker from the CLI on a 2948G? Why does Cisco make this so confusing?
View 5 Replies
View Related
May 14, 2012
We currently have the following configuration:
STB_6509#sho mod
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 10 WiSM WLAN Service Module WS-SVC-WISM-1-K9
2 24 CEF720 24 port 1000mb SFP WS-X6724-SFP
5 2 Supervisor Engine 720 (Active) WS-SUP720-3B
[code]....
I would like to add a redundant supervisor blade to the 6509 that is in production. Can this be done plug and play and require no reload. Are all WS-SUP720-3B the same as far as memory etc... or can I buy any used WS-SUP720-3B and it will work properly.
View 1 Replies
View Related
Feb 7, 2013
I have a WS-C4510R+E with
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 48 10/100/1000BaseT Premium POE E Series WS-X4748-RJ45V+E CAT1612L1JD
2 48 10/100/1000BaseT Premium POE E Series WS-X4748-RJ45V+E CAT1612L1JW
3 12 10GE SFP+ WS-X4712-SFP+E CAT1622L0SC
4 12 10GE SFP+ WS-X4712-SFP+E CAT1622L0RM
5 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7-E CAT1620L1UJ
6 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7-E CAT1620L1Z2
Can i add two WS-X4712-SFP+E and two 10 GE ethernet module also?
Is there 10GE ethernet module with WS-C4510R+E.
View 2 Replies
View Related
Dec 14, 2011
Here i have a customer who has 7609 router with modules
ws-+6748-ge-tx
ws-svc-wism-1-k9
ws-sup720-3b
ws-sup720-3b
ws-svc-wism-1-k9
ws-6724-sfp
ws-x6704=10ge
ws-x6724-sfp
will this modules will be supported to the new chaisis ios or in the chaisis 7609S
View 1 Replies
View Related
Dec 21, 2011
how can we upgrade 6500 non modular ios to normal 6500 ios?
View 5 Replies
View Related
Oct 11, 2011
I want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)
View 1 Replies
View Related
Aug 10, 2012
Is there functionality difference in Supervisor Engine 2 and Supervisor Engine 2T for Catalyst 6500 ?
View 3 Replies
View Related