Cisco Switching/Routing :: 6500 Redundant Supervisor Engine Will Forward Data While Is Standby

Oct 26, 2011

We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?

View 4 Replies


ADVERTISEMENT

Cisco Switching/Routing :: 6513 - Redundant Supervisor Engine 720-3B Reloads

Sep 1, 2010

There is a Cisco Catalyst 6513 in my office. Recently we decided to setup redundant Supervisor Engine 720-3B. When we did it, its became STANDBY COLD, and then it reloads. IOS is equal on both supervisors. It must be STANDBY HOT (SSO) redundancy. There is a configuration and show ver and show module outputs, and log of my actions.

View 3 Replies View Related

Cisco Switching/Routing :: Standby Supervisor Engine Not Sync In 4507R?

Dec 26, 2012

When i have configured the 4507R switch but the configure is not sync with the standby module..... I have doing some troubleshooting
 
1. type the command "show redundancy"  no standby module is showing

2. type the command " redundancy force-switchover"  showing the message " no standby module is present"

3. type the command "hw-module module 2 reset"  then the standby module is reset and status light is blinking like it is booting..

View 6 Replies View Related

Cisco Switching/Routing :: 2690 - SFP Ports On Active And Standby Supervisor Engine

Oct 19, 2012

We are expanding out LAN network with more 2960 access switches. All the access switches are suppose to be connected to core switch (4507R) but i have less port on the core switch.
 
On the core switch we have two supervisor engines (WS-X4515 ---description : "Supervisor IV with 2 1000BaseX GBIC ports"). I can see that on each supervisor engine i have two 1 GB SFP ports available and if i calculate for two supervioser engine i will have 4 1GB ports.
 
But at particular time only one supervisor engine is active and other is in standby mode (redundancy mode used is SSO between two SUP engines).
 
Can i used all 4 SFP ports for connecting 4 uplinks to the 4 access switch?Will all the 4 SFP ports active at one time or only 2 SFP ports will be active that is for only active supervisor engine.

View 10 Replies View Related

Cisco Switching/Routing :: 6500 Redundant Supervisor Port Channel?

Oct 30, 2011

I have a Cisco 6500 series switch with VS-C6509E-S720-10G ,I have two redundant supervisors between two chassis on the LAN with no add-on line cards ?

I need to know if I can use the redundant supervisor 10 Gb uplinks to form a layer-2 Port channel between the two 6500 switches as i do not want to use want to keep the port idle additionally I need more bandwidth between the two switches for my server farm?

View 1 Replies View Related

Cisco Infrastructure :: Supervisor Engine Catalyst 6500 Modular IOS?

Oct 11, 2011

I want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
  
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)

View 1 Replies View Related

Cisco WAN :: Functionality Difference In Supervisor Engine 2 / 2T For Catalyst 6500?

Aug 10, 2012

Is there functionality difference in Supervisor Engine 2 and Supervisor Engine 2T for Catalyst 6500 ?

View 3 Replies View Related

Cisco Switching/Routing :: Supervisor Engine 720 Errors

Apr 18, 2013

i have a standalone SUP720, no traffic is passing through it. only one port connected for remote telnet, its kind of backup device.today i checked its log, and there are some wiered message.is it a software bug or my SUP has gone bad? [code]

View 24 Replies View Related

Cisco Switching/Routing :: VSS With 4 Supervisor Engine 2T-10GE

May 6, 2013

We have a scenario with 2 chassis, both with 2 supervisor Engine 2T, we try to make a configuration of VSS with the chassis and would link to know if is possible have 2 supervisor on chassis one and 2 supervisors on chassis 2 with VSS?
  
Router#sho switch virtual redundancy
My Switch Id = 1
Peer Switch Id = 2
Last switchover reason = active unit removed
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso

[code]....
 
would like to use the second supervisors for obteind the local redundancy en chassis 1 and 2, this is possible?
 
the actually version on four supervisors is: s2t54-ipservicesk9-mz.SPA.150-1.SY3.bin

View 6 Replies View Related

Cisco Switching/Routing :: 6509 How To Configure VSS With Two Different Supervisor Engine

Oct 1, 2012

I have configured the VSS in two cisco 6509-E series with only one supervisor engine, but if i configured with two supervisor engine. it is going to common mode. One supervisor engine is 3c and 3cxl.

View 2 Replies View Related

Cisco Switching/Routing :: Upgrading Supervisor Engine On 4006?

Nov 3, 2011

I have an older 4006 with a Supervisor II+.  We now need OSPF support, which the Sup II+ does not provide.  I have access to a Supervisor III (WS-X4014), which will provide OSPF support.  Question is, are there any gotchas to shutting down the switch, replacing Supervisor Engines and then powering up?  What about the flash card?  On my current system, it appears that I am only using bootflash: , which is where the IOS resides (see below).  Since my startup config is in nvram and my IOS is in bootflash, what's the purpose of the flash card in slot0: ?  and where does NVRAM and bootflash actually live on a 4006 ( on the Supervisor Engine?)
 
sh bootvar
BOOT variable = bootflash:cat4500-ipbase-mz.122-31.SGA11.bin,1;,1;
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist

[Code].....

View 5 Replies View Related

Cisco Switching/Routing :: Catalyst 4006 Supervisor Engine Led Red

Nov 28, 2011

we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]

View 1 Replies View Related

Cisco Switching/Routing :: Supervisor Engine For 4003 Switch

Oct 24, 2012

I buy a Cisco 4003 Switch with Supervisor Engine I but it only run CatOs and i whant it to run Cisco IOS so whitch Supervisor Engine can the Cisco 4003 Switch run? i have look at the Supervisor Engine III it can run Cisco IOS and Layer 3 but can i use that in my Cisco 4003 switch?

View 14 Replies View Related

Cisco Switching/Routing :: C6500 Bootdisk And Supervisor Engine

Apr 5, 2013

For C6500 chassis,  sup-fould like to know the dirrerence between supervisor engiene 720 sup-bootflash and sup-bootdisk?

View 3 Replies View Related

Cisco Switching/Routing :: 4500 Supervisor Engine Error

Mar 16, 2012

On an existing 4500 switch with a single sup 6-E, another sup 6-E is added. But the second sup6-E comes up as synchronised with active and in a few minutes time, reloads again. the software is 12.2(44) is the same on both sup engines. the redundancy sso output shows that slot6 is disabled.

View 1 Replies View Related

Cisco Switching/Routing :: 6509 Adding A Redundant Supervisor?

Feb 10, 2012

I would like to add a redundant supervisor to my core 6509. Is this tricky to do? I know they have to be running the same IOS. I am worried if I put the new supervisor in it will write over the exsisting running config.

Catalyst 6000 supervisor 2 (Active)    WS-X6K-S2U-MSFC2
Policy Feature Card 2       WS-F6K-PFC2
Cat6k MSFC 2 daughterboard  WS-F6K-MSFC2

View 4 Replies View Related

Cisco Switching/Routing :: IOS Upgrade On 4507R With Redundant Supervisor

Feb 5, 2013

we have 2 Supervisor IV modules in our 4507, i want to upgrade the IOS as its still on 12.2 and i am going to upgrade it to the latest. 
  
my first question is, if i update the IOS on the bootflash will it replicate to the secondarybootflash? 
 
secondly, can i force a reboot of the secondary supervisor, then the primary after the secondary is up?  i'm just trying to minimise downtime and get a plan going. 
  
is there a difference in 12 vs 15 that would impact my current config that i should be aware of?

View 2 Replies View Related

Cisco Switching/Routing :: Redundant Supervisor Engin For 4507R?

Nov 7, 2011

I have an 4507R with one Supervisor Engin V card. I want to add a redundant supervisor engin card to my 4507R Chassis.

Can i use supervisor engin 6-E for redundant or i must use Supervisor Engin V ?

Witch model of Supervisor Engines Supported with this chasis?

View 2 Replies View Related

Cisco Switching/Routing :: Core 4500 Series Supervisor Engine?

Jun 19, 2012

Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?

View 1 Replies View Related

Cisco Switching/Routing :: 4507R Supervisor Engine IV X4515 Not Booting

Dec 5, 2011

I have a 4507R with a WS-X4515 supervisor V. It was booting into rommon mode, so I attempted to boot to an IOS image from TFTP. The boot process hangs at at the end of the below output and the then the status light blinks orange. I left it sit like this overnight, and it remained the same.  
 
rommon 23 >boot tftp://x.x.x.x/cat4500-entservicesk9-mz.122-53.SG2.bin
 Tftp Session details are ....
 Filename     : /cat4500-entservicesk9-mz.122-53.SG2.bin

[Code]......

View 9 Replies View Related

Cisco Switching/Routing :: 4507R Configuring Supervisor Engine Redundancy

Feb 14, 2012

How to configure Supervisor Engine Redundancy between two different cisco 4507R and 4506E.

View 5 Replies View Related

Cisco Switching/Routing :: Run VSS On 6513 / 6509 Considering Both Has Same Supervisor Engine 2T And IOS Image

Jun 25, 2012

Is it possible to run VSS on 6513 and 6509 when considering both has same supervisor engine 2T and same IOS image.

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6509-E / Replace Supervisor Engine 720 10GE

May 15, 2012

we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario 

1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the  faulty VS-S720-10G from the slot 5
 
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?

View 3 Replies View Related

Cisco Switching/Routing :: 6513 / Difference Between Supervisor Engine 720 Active And Hot Status?

Apr 19, 2013

In my 6513 switch chassis we have two Supervisor Engines 720 one is marked Active other as Hot. what is the diffrence in their mode as by name I suppose that Active one is currently in use and Hot one is in standby mode.They are showing in this manner.    
 
Module        Ports      Card Type
  7                 2          Supervisor Engine 720 (Active)     
  8                 2          Supervisor Engine 720 (Hot)

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 6513 - Redundant Supervisor Not Synced After Insertion

Aug 23, 2012

The SuperVisor engine in slot 1 of a Catalyst 6513 needed to be replaced because a hardware defect. The SuperVisor engine in slot 2 is active and running CatOS 8.5. The new SuperVisor engine for slot 1 came with CatOS 6.3 and was not syncronized auromatically after insertion. When the customer enter the command "Show boot" he get the output:
 
AG-A6513-51> (enable) sh boot
BOOT variable = bootflash:cat6000-sup2k8.8-5-5.bin,1;bootflash:cat6000-sup2k8.7-6-2.bin,1;

[Code].....

View 1 Replies View Related

Cisco Switching/Routing :: 4500 - Redundant Supervisor 7-E - Use All Uplink Ports At Same Time

Dec 15, 2011

I know in the past on earlier models of the supervisors that you couldn't use all eight uplink ports(4 on each supervisor) simultaneously when you have two supervisors on the chassis.  Is this the same case for the 10Gb uplinks on the supervisor 7-E on the 4500 chassis?  I tried doing my research but couldn't find an answer.

View 3 Replies View Related

Cisco Switching/Routing :: 4500 Standby Supervisor Not Detected?

Nov 25, 2011

I have issue with my 4510 switch which has got two supervisor engine in single switch.
 
I am trying find the root cause but not able to ....
 
Standy supervisor engine is not detecting ....
 
In show module and bootvar output also , there is error saying " Standby is not up "
 
show module ouput :
 
Switch-4510#show moduleChassis Type : WS-C4510RPower consumed by backplane : 40 WattsMod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 6 Sup V-10GE 10GE (X2),

[Code].....

View 11 Replies View Related

Cisco Switching/Routing :: Upgrading Memory For Redundant Supervisor Modules Nexus 7K18?

Mar 6, 2012

I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 4500E Supervisor Engine 7-E / Possible To Deploy Simultaneously Both Type Of Ports

Aug 8, 2012

We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
 
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?

View 2 Replies View Related

Cisco Switching/Routing :: 4500 Requirement For NSF / SSO Commands On Standby / Active Supervisor

Apr 22, 2012

I went through the configuration guide for 4500 series switches for NSF/SSO for failover between Sup's. I just wanted to know that that are we supposed to run the SSO command on both of the supervisors? Secondly, are we only supposed to run the nsf process under EIGRP on the secondary supervisor and routing peers and not on the primary supervisor?

View 2 Replies View Related

Cisco Switching/Routing :: Copying IOS From Standby To Active Supervisor 4507 Switch

Jun 4, 2012

I was upgrading IOS on 4507 R with dual supervisor.I download the IOS on Active supervisior and did reboot.After reboot i login to switch then i got switch standby prompt.I found that after reboot active supervisior  became standby supervisior.
 
Now new IOS  is on standby supervisior.Need to confirm below..So this means that IOS  does not syn  within the  supervisiors as compared to config  right ?
 
-Which command i can use that will copy IOS from standby supe to Active supe??
 -Which command i can use that will show both active and standby supe with new IOS?
 -Is there any command that i can use to switchover from active to standby supe??

View 3 Replies View Related

Cisco Switching/Routing :: 6500 What Happens When A Supervisor Fails

Feb 3, 2010

We've been mocking up a test lab to test VSS on two 6500's.  Each 6500 has one sup720 and a 6708-10ge blade and we've established the two 10ge links between the two chassis; the first from the each chassis' sup and the second from each 6708.My question is, what happens when the supervisor fails on one of the chassis?

View 10 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 / QoS For Supervisor 2T?

Apr 30, 2013

I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
 
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
 
[URL]
 
But I don't see anything for the new Supervisor 2T?

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved