Cisco Switching/Routing :: 4507R Configuring Supervisor Engine Redundancy

Feb 14, 2012

How to configure Supervisor Engine Redundancy between two different cisco 4507R and 4506E.

View 5 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Standby Supervisor Engine Not Sync In 4507R?

Dec 26, 2012

When i have configured the 4507R switch but the configure is not sync with the standby module..... I have doing some troubleshooting
 
1. type the command "show redundancy"  no standby module is showing

2. type the command " redundancy force-switchover"  showing the message " no standby module is present"

3. type the command "hw-module module 2 reset"  then the standby module is reset and status light is blinking like it is booting..

View 6 Replies View Related

Cisco Switching/Routing :: 4507R Supervisor Engine IV X4515 Not Booting

Dec 5, 2011

I have a 4507R with a WS-X4515 supervisor V. It was booting into rommon mode, so I attempted to boot to an IOS image from TFTP. The boot process hangs at at the end of the below output and the then the status light blinks orange. I left it sit like this overnight, and it remained the same.  
 
rommon 23 >boot tftp://x.x.x.x/cat4500-entservicesk9-mz.122-53.SG2.bin
 Tftp Session details are ....
 Filename     : /cat4500-entservicesk9-mz.122-53.SG2.bin

[Code]......

View 9 Replies View Related

Cisco Switching/Routing :: Secon SUP Engine On 4507R Switch?

Mar 8, 2012

I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
 
SWITCH-4507#sh ver
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version
12.2(25)EWA8, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 24-Jan-07 15:28 by pwade

[code]....

View 4 Replies View Related

Cisco Switching/Routing :: Supervisor Engine 720 Errors

Apr 18, 2013

i have a standalone SUP720, no traffic is passing through it. only one port connected for remote telnet, its kind of backup device.today i checked its log, and there are some wiered message.is it a software bug or my SUP has gone bad? [code]

View 24 Replies View Related

Cisco Switching/Routing :: VSS With 4 Supervisor Engine 2T-10GE

May 6, 2013

We have a scenario with 2 chassis, both with 2 supervisor Engine 2T, we try to make a configuration of VSS with the chassis and would link to know if is possible have 2 supervisor on chassis one and 2 supervisors on chassis 2 with VSS?
  
Router#sho switch virtual redundancy
My Switch Id = 1
Peer Switch Id = 2
Last switchover reason = active unit removed
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso

[code]....
 
would like to use the second supervisors for obteind the local redundancy en chassis 1 and 2, this is possible?
 
the actually version on four supervisors is: s2t54-ipservicesk9-mz.SPA.150-1.SY3.bin

View 6 Replies View Related

Cisco Switching/Routing :: IOS Upgrade On 4507R With Redundant Supervisor

Feb 5, 2013

we have 2 Supervisor IV modules in our 4507, i want to upgrade the IOS as its still on 12.2 and i am going to upgrade it to the latest. 
  
my first question is, if i update the IOS on the bootflash will it replicate to the secondarybootflash? 
 
secondly, can i force a reboot of the secondary supervisor, then the primary after the secondary is up?  i'm just trying to minimise downtime and get a plan going. 
  
is there a difference in 12 vs 15 that would impact my current config that i should be aware of?

View 2 Replies View Related

Cisco Switching/Routing :: Redundant Supervisor Engin For 4507R?

Nov 7, 2011

I have an 4507R with one Supervisor Engin V card. I want to add a redundant supervisor engin card to my 4507R Chassis.

Can i use supervisor engin 6-E for redundant or i must use Supervisor Engin V ?

Witch model of Supervisor Engines Supported with this chasis?

View 2 Replies View Related

Cisco Switching/Routing :: 6509 How To Configure VSS With Two Different Supervisor Engine

Oct 1, 2012

I have configured the VSS in two cisco 6509-E series with only one supervisor engine, but if i configured with two supervisor engine. it is going to common mode. One supervisor engine is 3c and 3cxl.

View 2 Replies View Related

Cisco Switching/Routing :: Upgrading Supervisor Engine On 4006?

Nov 3, 2011

I have an older 4006 with a Supervisor II+.  We now need OSPF support, which the Sup II+ does not provide.  I have access to a Supervisor III (WS-X4014), which will provide OSPF support.  Question is, are there any gotchas to shutting down the switch, replacing Supervisor Engines and then powering up?  What about the flash card?  On my current system, it appears that I am only using bootflash: , which is where the IOS resides (see below).  Since my startup config is in nvram and my IOS is in bootflash, what's the purpose of the flash card in slot0: ?  and where does NVRAM and bootflash actually live on a 4006 ( on the Supervisor Engine?)
 
sh bootvar
BOOT variable = bootflash:cat4500-ipbase-mz.122-31.SGA11.bin,1;,1;
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist

[Code].....

View 5 Replies View Related

Cisco Switching/Routing :: Catalyst 4006 Supervisor Engine Led Red

Nov 28, 2011

we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]

View 1 Replies View Related

Cisco Switching/Routing :: Supervisor Engine For 4003 Switch

Oct 24, 2012

I buy a Cisco 4003 Switch with Supervisor Engine I but it only run CatOs and i whant it to run Cisco IOS so whitch Supervisor Engine can the Cisco 4003 Switch run? i have look at the Supervisor Engine III it can run Cisco IOS and Layer 3 but can i use that in my Cisco 4003 switch?

View 14 Replies View Related

Cisco Switching/Routing :: C6500 Bootdisk And Supervisor Engine

Apr 5, 2013

For C6500 chassis,  sup-fould like to know the dirrerence between supervisor engiene 720 sup-bootflash and sup-bootdisk?

View 3 Replies View Related

Cisco Switching/Routing :: 4500 Supervisor Engine Error

Mar 16, 2012

On an existing 4500 switch with a single sup 6-E, another sup 6-E is added. But the second sup6-E comes up as synchronised with active and in a few minutes time, reloads again. the software is 12.2(44) is the same on both sup engines. the redundancy sso output shows that slot6 is disabled.

View 1 Replies View Related

Cisco Switching/Routing :: 4507R+E / SSO Not Available As Redundancy Mode Option

Oct 31, 2012

Why rpr is the only available redundancy mode option available to me.  I'm running a 4507R+E with twin SUP7-E's.
 
Abbreviated show ver Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.03.01.SG RELEASE SOFTWARE (fc2)Technical Support: [URL]/techsupportCopyright (c) 1986-2012 by Cisco Systems, Inc.Compiled Sun 26-Aug-12 13:45 by prod_rel_team
ROM: 15.0(1r)SG2gp08401 uptime is 6 weeks, 6 days, 4 hours, 59 minutesUptime for this control processor is 6 weeks, 3 days, 2 hours, 21 minutesSystem returned to ROM by RPR SwitchoverSystem image file is "bootflash:/cat4500e-universalk9.SPA.03.03.01.SG.151-1.SG1.bin"Jawa Revision 7, Snowtrooper Revision 0x0.0x1C

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: Core 4500 Series Supervisor Engine?

Jun 19, 2012

Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?

View 1 Replies View Related

Cisco Switching/Routing :: 6513 - Redundant Supervisor Engine 720-3B Reloads

Sep 1, 2010

There is a Cisco Catalyst 6513 in my office. Recently we decided to setup redundant Supervisor Engine 720-3B. When we did it, its became STANDBY COLD, and then it reloads. IOS is equal on both supervisors. It must be STANDBY HOT (SSO) redundancy. There is a configuration and show ver and show module outputs, and log of my actions.

View 3 Replies View Related

Cisco Switching/Routing :: Run VSS On 6513 / 6509 Considering Both Has Same Supervisor Engine 2T And IOS Image

Jun 25, 2012

Is it possible to run VSS on 6513 and 6509 when considering both has same supervisor engine 2T and same IOS image.

View 1 Replies View Related

Cisco Switching/Routing :: Match Protocol Command In Catalyst 4507R- Supervisor 7LE

Nov 28, 2012

My Company use Core Sw 4507R-Sup 7L-E with Enterprise Services License. I has upgraded to use iOS cat4500e-universal.SPA.03.03.01.SG.151-1.SG1.bin

When I use match protocol in class-map, there are only about 10 protocols, and not have those ones I need. I intend to expand the list of protocols to do some Policy-map by loading PDLM. But 4507 is no longer support NBAR. So do we have another way to set Catalyst 4507R with Sup 7L-E recongnize more protocols in match protocol command?

View 1 Replies View Related

Cisco Switching/Routing :: C4510 With Redundancy Supervisor 7E Crashed

Oct 31, 2011

Our company's c4510 with redundancy supervisor 7E just been crashed, first the master then the slave. What should I do ?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6509-E / Replace Supervisor Engine 720 10GE

May 15, 2012

we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario 

1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the  faulty VS-S720-10G from the slot 5
 
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?

View 3 Replies View Related

Cisco Switching/Routing :: 6513 / Difference Between Supervisor Engine 720 Active And Hot Status?

Apr 19, 2013

In my 6513 switch chassis we have two Supervisor Engines 720 one is marked Active other as Hot. what is the diffrence in their mode as by name I suppose that Active one is currently in use and Hot one is in standby mode.They are showing in this manner.    
 
Module        Ports      Card Type
  7                 2          Supervisor Engine 720 (Active)     
  8                 2          Supervisor Engine 720 (Hot)

View 4 Replies View Related

Cisco Switching/Routing :: 2690 - SFP Ports On Active And Standby Supervisor Engine

Oct 19, 2012

We are expanding out LAN network with more 2960 access switches. All the access switches are suppose to be connected to core switch (4507R) but i have less port on the core switch.
 
On the core switch we have two supervisor engines (WS-X4515 ---description : "Supervisor IV with 2 1000BaseX GBIC ports"). I can see that on each supervisor engine i have two 1 GB SFP ports available and if i calculate for two supervioser engine i will have 4 1GB ports.
 
But at particular time only one supervisor engine is active and other is in standby mode (redundancy mode used is SSO between two SUP engines).
 
Can i used all 4 SFP ports for connecting 4 uplinks to the 4 access switch?Will all the 4 SFP ports active at one time or only 2 SFP ports will be active that is for only active supervisor engine.

View 10 Replies View Related

Cisco Switching/Routing :: 6509 / 4900 - Network Down Cause Switching Supervisor With Redundancy

Jan 11, 2012

we've had an issue with our network, we have 2 6509 connected with redundancy, which are connected with 2 x 4900 Switches, from which are connected to a ESX Chassis for visualization, the thing is that the ESX stopped working, and the 4900 switches, and the main core were suffering from overload, they hang on it very well, in order to stop the overload, one of the links to the ESX Chassis were disconnected from one of the 4900 switches. The CPU usage from the 4900 and the core(6509) went down below 40%, and then they started to migrate the virtual servers from the chassis to another 2 chassis that were added right after. They were actually working well, but suddenly the 6509 changed to the other supervisor after everything was OK. We were wondering what could have been the cause of this, maybe the virtual servers migrations, maybe the overload from the ESX ? We also had a few question, is there any need to reload the cores every few months as a planned task ? Because the cores have been up for more than 1 year. And also is there any kind of of tool to monitor the CPU status, or the status overall from the cores or the switches ?

View 3 Replies View Related

Cisco Switching/Routing :: 6500 Redundant Supervisor Engine Will Forward Data While Is Standby

Oct 26, 2011

We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 4500E Supervisor Engine 7-E / Possible To Deploy Simultaneously Both Type Of Ports

Aug 8, 2012

We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
 
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?

View 2 Replies View Related

Cisco Switching/Routing :: Configuring 4507R For LACP And Trunking?

Apr 3, 2008

We're trying to configure our Cisco 4507 (Supervisor Engine IV) to allow a new Dell server with a pair of Broadcom 5708 GigE NIC's to aggregate its NIC's to give us a 2gbps link to the switch.
 
So far we seem to have got the team and LACP up and enabled, but the adaptor that the Broadcom Admin Util creates for the team is only showing a 1gbps connection where I would have expected it to show as 2gbps.
 
The individual NICs show as connected at 1gbps. We're not Cisco experts so are struggling on how to get the 2 NICs to aggregate.
 
On the server side we've done nothing other than create a team using 802.3ad LINk Aggregation using LACP.
 
This is what I think the relevent output from "sho conf" is, more available if needed.
 
version 12.2
boot system flash bootflash:cat4000-i9s-mz.122-18.EW1.bin
!
interface Port-channel2

[Code].....

View 3 Replies View Related

Cisco WAN :: 7204VXR / 4507R-E - Redundancy To Single ISP?

Dec 12, 2011

what I have are 2 x 7204VXR (Gateways), 1 x 4507R-E (Coreswitch), and our ISP have 7609.Got some issues with redundancy with our ISP.
 
                                        7609
                                        I     I
                                        I     I
                               7204-A    7204-B
                                    |             |
                                    |    vrrp   |
                                    |             |
                                    -4507R-E-
                                          |
                                          |
                               internal network
 
Both outside interfaces of 7204 gateways are connecting to 7609 with different public ip block.I used VRRP for my internal nework and failover have been tested working.Even tried to remove link of 7204-A and 7609, the failover works perfect.But somehow we're facing a problem:

- If I shutdown/ remove the link between my 4507R-E and 7204-A (primary gw_higher vrrp priority), vrrp redundancy/failover still works but internal network's internet connection goes down.
 
I asked our ISP and the route commands they put in their 7609 are as of follows:
ip route 3.8.8.0 255.255.255.0 3.4.4.4 name TO CUSTOMER LINK 1
ip route 3.8.8.0 255.255.255.0 3.3.3.3 2 name TO CUSTOMER LINK 2
 
And if they're trying to use Reliable Static Routing Backup Using Object Tracking, the internal network's internet connections is intermittent....alternate 4 ping reply and 4 timeout.
 
Note: IP used are sample only

View 6 Replies View Related

Cisco WAN :: Redundancy With Existing Sup Engine WS-x4516

Mar 12, 2013

I have supervisor engine ws-x4516 with two line card  WS-X4424 - GB - RJ45 - 1No ,WS-X4548 - GB - RJ45 - 1No. Now i want switch and hardware redundancy.

View 3 Replies View Related

Distributed Forwarding Card For Supervisor Engine 2T

Dec 23, 2011

I was looking to 6500 series switches. I saw DFC4 module (WS-F6K-DFC4-A, WS-F6K-DFC4-AXL) and (WS-F6K-DFC4-E, WS-F6K-DFC4-EXL). Data sheet for supervisor engine 2T wrote that for maximum performance you should DFC4. I'm a bit confused. I didn't any useful information about it:

1. DFC4 is a separate module(consumes 1 slot)? Does it have any ports on it?

2. Is it a daughter card? If yes, should it be installed on supervisor or it should be installed on line cards?

View 7 Replies View Related

Cisco WAN :: 7690 - Removing And Installing A Supervisor Engine

Dec 26, 2010

Removing and Installing a Supervisor Engine on a cisco router 7690 and more important IOS upgrade of this module.
 
I need some kind of manual, but I would prefer a short procedure to do this change. A brief of the steps to do that. Also i don't if i have to upgrade the new module after install it.
 
PD. 
IP7VAL02#sh modMod Ports Card                    Type                              Model              Serial No.--- ----- -------------------------------------- ------------------ -----------  1   48  CEF720 48 port 10/100/1000mb Ethernet        WS-X6748-GE-TX     SAL1034Z32J  2   48  CEF720 48 port 10/100

[Code]....

View 1 Replies View Related

Cisco WAN :: Catalyst 4500 E-Series Supervisor Engine 7L-E?

Aug 12, 2012

I have a strange issue with 4500 E chassis loaded with SUP 7L-E which always remains in ORANGE LED status, also the uplink ports interface is down and the line protocol is down  but when i execute the command sh int gig1/5 it show me the media type sfp but there is no red laser light seen in the sfp transiever,The below command is configured for the uplink gig port on the SUP engine.hw-module uplink select gigabitethernet?

View 10 Replies View Related

Cisco WAN :: Supervisor Redundancy For The 6500?

May 14, 2012

We currently have the following configuration:
 
STB_6509#sho mod
Mod Ports Card Type                              Model              Serial No.
--- ----- -------------------------------------- ------------------ -----------
  1   10  WiSM WLAN Service Module         WS-SVC-WISM-1-K9  
  2   24  CEF720 24 port 1000mb SFP         WS-X6724-SFP      
  5    2  Supervisor Engine 720 (Active)         WS-SUP720-3B      

[code]....
 
I would like to add a redundant supervisor blade to the 6509 that is in production. Can this be done plug and play and require no reload. Are all WS-SUP720-3B the same as far as memory etc... or can I buy any used WS-SUP720-3B and it will work properly.

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved