Cisco Switching/Routing :: Supervisor Engine 720 Errors
Apr 18, 2013
i have a standalone SUP720, no traffic is passing through it. only one port connected for remote telnet, its kind of backup device.today i checked its log, and there are some wiered message.is it a software bug or my SUP has gone bad? [code]
View 24 Replies
ADVERTISEMENT
May 6, 2013
We have a scenario with 2 chassis, both with 2 supervisor Engine 2T, we try to make a configuration of VSS with the chassis and would link to know if is possible have 2 supervisor on chassis one and 2 supervisors on chassis 2 with VSS?
Router#sho switch virtual redundancy
My Switch Id = 1
Peer Switch Id = 2
Last switchover reason = active unit removed
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso
[code]....
would like to use the second supervisors for obteind the local redundancy en chassis 1 and 2, this is possible?
the actually version on four supervisors is: s2t54-ipservicesk9-mz.SPA.150-1.SY3.bin
View 6 Replies
View Related
Oct 1, 2012
I have configured the VSS in two cisco 6509-E series with only one supervisor engine, but if i configured with two supervisor engine. it is going to common mode. One supervisor engine is 3c and 3cxl.
View 2 Replies
View Related
Nov 3, 2011
I have an older 4006 with a Supervisor II+. We now need OSPF support, which the Sup II+ does not provide. I have access to a Supervisor III (WS-X4014), which will provide OSPF support. Question is, are there any gotchas to shutting down the switch, replacing Supervisor Engines and then powering up? What about the flash card? On my current system, it appears that I am only using bootflash: , which is where the IOS resides (see below). Since my startup config is in nvram and my IOS is in bootflash, what's the purpose of the flash card in slot0: ? and where does NVRAM and bootflash actually live on a 4006 ( on the Supervisor Engine?)
sh bootvar
BOOT variable = bootflash:cat4500-ipbase-mz.122-31.SGA11.bin,1;,1;
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist
[Code].....
View 5 Replies
View Related
Nov 28, 2011
we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]
View 1 Replies
View Related
Oct 24, 2012
I buy a Cisco 4003 Switch with Supervisor Engine I but it only run CatOs and i whant it to run Cisco IOS so whitch Supervisor Engine can the Cisco 4003 Switch run? i have look at the Supervisor Engine III it can run Cisco IOS and Layer 3 but can i use that in my Cisco 4003 switch?
View 14 Replies
View Related
Apr 5, 2013
For C6500 chassis, sup-fould like to know the dirrerence between supervisor engiene 720 sup-bootflash and sup-bootdisk?
View 3 Replies
View Related
Mar 16, 2012
On an existing 4500 switch with a single sup 6-E, another sup 6-E is added. But the second sup6-E comes up as synchronised with active and in a few minutes time, reloads again. the software is 12.2(44) is the same on both sup engines. the redundancy sso output shows that slot6 is disabled.
View 1 Replies
View Related
Jun 19, 2012
Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?
View 1 Replies
View Related
Dec 26, 2012
When i have configured the 4507R switch but the configure is not sync with the standby module..... I have doing some troubleshooting
1. type the command "show redundancy" no standby module is showing
2. type the command " redundancy force-switchover" showing the message " no standby module is present"
3. type the command "hw-module module 2 reset" then the standby module is reset and status light is blinking like it is booting..
View 6 Replies
View Related
Dec 5, 2011
I have a 4507R with a WS-X4515 supervisor V. It was booting into rommon mode, so I attempted to boot to an IOS image from TFTP. The boot process hangs at at the end of the below output and the then the status light blinks orange. I left it sit like this overnight, and it remained the same.
rommon 23 >boot tftp://x.x.x.x/cat4500-entservicesk9-mz.122-53.SG2.bin
Tftp Session details are ....
Filename : /cat4500-entservicesk9-mz.122-53.SG2.bin
[Code]......
View 9 Replies
View Related
Feb 14, 2012
How to configure Supervisor Engine Redundancy between two different cisco 4507R and 4506E.
View 5 Replies
View Related
Sep 1, 2010
There is a Cisco Catalyst 6513 in my office. Recently we decided to setup redundant Supervisor Engine 720-3B. When we did it, its became STANDBY COLD, and then it reloads. IOS is equal on both supervisors. It must be STANDBY HOT (SSO) redundancy. There is a configuration and show ver and show module outputs, and log of my actions.
View 3 Replies
View Related
Jun 25, 2012
Is it possible to run VSS on 6513 and 6509 when considering both has same supervisor engine 2T and same IOS image.
View 1 Replies
View Related
May 15, 2012
we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario
1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the faulty VS-S720-10G from the slot 5
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?
View 3 Replies
View Related
Apr 19, 2013
In my 6513 switch chassis we have two Supervisor Engines 720 one is marked Active other as Hot. what is the diffrence in their mode as by name I suppose that Active one is currently in use and Hot one is in standby mode.They are showing in this manner.
Module Ports Card Type
7 2 Supervisor Engine 720 (Active)
8 2 Supervisor Engine 720 (Hot)
View 4 Replies
View Related
Oct 19, 2012
We are expanding out LAN network with more 2960 access switches. All the access switches are suppose to be connected to core switch (4507R) but i have less port on the core switch.
On the core switch we have two supervisor engines (WS-X4515 ---description : "Supervisor IV with 2 1000BaseX GBIC ports"). I can see that on each supervisor engine i have two 1 GB SFP ports available and if i calculate for two supervioser engine i will have 4 1GB ports.
But at particular time only one supervisor engine is active and other is in standby mode (redundancy mode used is SSO between two SUP engines).
Can i used all 4 SFP ports for connecting 4 uplinks to the 4 access switch?Will all the 4 SFP ports active at one time or only 2 SFP ports will be active that is for only active supervisor engine.
View 10 Replies
View Related
Oct 26, 2011
We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?
View 4 Replies
View Related
Aug 8, 2012
We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?
View 2 Replies
View Related
Dec 23, 2011
I was looking to 6500 series switches. I saw DFC4 module (WS-F6K-DFC4-A, WS-F6K-DFC4-AXL) and (WS-F6K-DFC4-E, WS-F6K-DFC4-EXL). Data sheet for supervisor engine 2T wrote that for maximum performance you should DFC4. I'm a bit confused. I didn't any useful information about it:
1. DFC4 is a separate module(consumes 1 slot)? Does it have any ports on it?
2. Is it a daughter card? If yes, should it be installed on supervisor or it should be installed on line cards?
View 7 Replies
View Related
Dec 26, 2010
Removing and Installing a Supervisor Engine on a cisco router 7690 and more important IOS upgrade of this module.
I need some kind of manual, but I would prefer a short procedure to do this change. A brief of the steps to do that. Also i don't if i have to upgrade the new module after install it.
PD.
IP7VAL02#sh modMod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ ----------- 1 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL1034Z32J 2 48 CEF720 48 port 10/100
[Code]....
View 1 Replies
View Related
Aug 12, 2012
I have a strange issue with 4500 E chassis loaded with SUP 7L-E which always remains in ORANGE LED status, also the uplink ports interface is down and the line protocol is down but when i execute the command sh int gig1/5 it show me the media type sfp but there is no red laser light seen in the sfp transiever,The below command is configured for the uplink gig port on the SUP engine.hw-module uplink select gigabitethernet?
View 10 Replies
View Related
Oct 11, 2011
I want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)
View 1 Replies
View Related
Aug 10, 2012
Is there functionality difference in Supervisor Engine 2 and Supervisor Engine 2T for Catalyst 6500 ?
View 3 Replies
View Related
Jan 11, 2012
we've had an issue with our network, we have 2 6509 connected with redundancy, which are connected with 2 x 4900 Switches, from which are connected to a ESX Chassis for visualization, the thing is that the ESX stopped working, and the 4900 switches, and the main core were suffering from overload, they hang on it very well, in order to stop the overload, one of the links to the ESX Chassis were disconnected from one of the 4900 switches. The CPU usage from the 4900 and the core(6509) went down below 40%, and then they started to migrate the virtual servers from the chassis to another 2 chassis that were added right after. They were actually working well, but suddenly the 6509 changed to the other supervisor after everything was OK. We were wondering what could have been the cause of this, maybe the virtual servers migrations, maybe the overload from the ESX ? We also had a few question, is there any need to reload the cores every few months as a planned task ? Because the cores have been up for more than 1 year. And also is there any kind of of tool to monitor the CPU status, or the status overall from the cores or the switches ?
View 3 Replies
View Related
Jan 4, 2013
I am currently running a 4506 with a sup V engine. I have purchased a sup 7 engine. Is there a guide on how to perform this task. I am sure I need to do an IOS update as well.
View 2 Replies
View Related
Jan 1, 2013
I have recetly upgraded our core switches (6509E) to SUP 2T from 32. Each core has 2 SUP's (hot/standby). out of 4 SUP engines, one is defective. i had received the new SUP from cisco. Currently my core swicth 2 is running with single SUP. Can i directly insert the new SUP engine in slot 6 (free)? will it automatically load the existing IOS from active SUP? what will happen if the new SUP has a different IOS other than the active SUP? Also is there a way to find out the IOS version without inserting in the chasy?
View 2 Replies
View Related
May 14, 2013
I would like to find out how to upgrade SUP engine 32 via USB port as I've never did IOS upgrade on a SUP engine via USB before
View 5 Replies
View Related
May 13, 2012
We recently perchaced 4503 switch with Sub Engine 7L. It has universal IOS. We are unable to run EIGRP and HSRP protocol and the switch came with temporal license.how to proceed further to get EIGRP and HSRP enabled on the 4503 switch.
View 8 Replies
View Related
Mar 8, 2012
I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
SWITCH-4507#sh ver
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version
12.2(25)EWA8, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 24-Jan-07 15:28 by pwade
[code]....
View 4 Replies
View Related
Mar 27, 2013
I am having problems with IGMP and QoS on CAT6500 platform with SUP720 engine.The problem is, it seems that all IGMP packets are getting marked with DSCP 48 when sent out of the switch regardless of any input service policy. I found several articles saying that PFC QoS does not apply to IGMP packets. However in IOS 15 that should be possible, but I didn't get it to work there either. [code]
View 0 Replies
View Related
Oct 4, 2012
We are facing a strange issue, our ACE 20 got failed due to power issue , after RMA once we are installing ACE 20 to 6509 , the status LED is showing ORANGE . The sh module shows it as " Others " ... The IOS is same as it was previously in 6509 .
View 2 Replies
View Related
Feb 3, 2010
We've been mocking up a test lab to test VSS on two 6500's. Each 6500 has one sup720 and a 6708-10ge blade and we've established the two 10ge links between the two chassis; the first from the each chassis' sup and the second from each 6708.My question is, what happens when the supervisor fails on one of the chassis?
View 10 Replies
View Related