Cisco Switching/Routing :: 6509 ACE Application Control Engine Module
Oct 4, 2012
We are facing a strange issue, our ACE 20 got failed due to power issue , after RMA once we are installing ACE 20 to 6509 , the status LED is showing ORANGE . The sh module shows it as " Others " ... The IOS is same as it was previously in 6509 .
View 2 Replies
ADVERTISEMENT
Jan 1, 2013
I have recetly upgraded our core switches (6509E) to SUP 2T from 32. Each core has 2 SUP's (hot/standby). out of 4 SUP engines, one is defective. i had received the new SUP from cisco. Currently my core swicth 2 is running with single SUP. Can i directly insert the new SUP engine in slot 6 (free)? will it automatically load the existing IOS from active SUP? what will happen if the new SUP has a different IOS other than the active SUP? Also is there a way to find out the IOS version without inserting in the chasy?
View 2 Replies
View Related
May 14, 2013
I would like to find out how to upgrade SUP engine 32 via USB port as I've never did IOS upgrade on a SUP engine via USB before
View 5 Replies
View Related
Oct 1, 2012
I have configured the VSS in two cisco 6509-E series with only one supervisor engine, but if i configured with two supervisor engine. it is going to common mode. One supervisor engine is 3c and 3cxl.
View 2 Replies
View Related
Jun 25, 2012
Is it possible to run VSS on 6513 and 6509 when considering both has same supervisor engine 2T and same IOS image.
View 1 Replies
View Related
May 15, 2012
we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario
1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the faulty VS-S720-10G from the slot 5
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?
View 3 Replies
View Related
May 16, 2011
We have a 6509 with an ACE module. For reasons I don't fully understand the ACE is running using a BVI in bridge mode. It has loads of secondary interfaces.
[Code]...
I can ping all of the IPs on the BVI, but only servers in Subnet 10.7.42/42 can ping out of the the layer 3 on the 6509. I have all the routes configured properly on the 6509 pointing to the ACE for these subnets. The question is though the config has been excepted, is there a limit to the number of secondary on a BVI.
View 1 Replies
View Related
May 8, 2013
I am desiging a topology with two Cat 6509 and Two ACE Module, one ACE per Catalyst. I am thinking to use bridge mode for the customer contexts, I would like to know if the Bridged mode is an Assymetric topology.
The server gateway is the ip address of the ACE or the Router?
View 6 Replies
View Related
Sep 10, 2012
I have a pair of 6509-E Switches running VS-720 Supervisors. We are planning to add Ace Module onto the 6509-E. Will IP Base Image suffice the requirement? Will Ace Module work with only IP Base Image?
View 1 Replies
View Related
Mar 4, 2012
I have a switch Cisco WS-C6509-E WS-X6716-10G-3C module ( module for 10 GB) , i have the IOS s72033-ipservicesk9-mz.122-18.SXF9.bin. I want to know if this IOS can support this module or not ? or , if i must do a upgrade , is that the IOS : "s72033-ipservicesk9_wan-mz.122-33.SXH8" work fine ?
View 7 Replies
View Related
Aug 26, 2012
I trying configure ASN traffic load balance, but doesn't works.I have one Cisco Catalyst 6509 and onde Cisco Ace10 module, in my context "PanWEB" i have the interfaces above: [code] If i try to establish a telnet session(telnet 10.96.202.10 80) i see the SYN packet passing through the ACE and going to the real server, but, the server do not response the SYN packet. I done a capture in the server using wireshark and could see that the IP address of the destination is the VIP and not the rserver ip address , this is a problem? Why can not I have the SYN + ACK from the server?
View 5 Replies
View Related
Jul 31, 2012
Suffered a big outage on the network, the fix was to reload the module 3 on the 6509 switch, we had these errors on the log %CONST_DIAG-SW1_SP-3-HM_PORT_TEST_FAIL: Switch 1 Module 3 TestUnusedPortLoopback Port(s)[24,46] failed. System operation continues.in the end, we reloaded the card and it was all ok. is there anything I can do to check the card / or any deeper logs? would that error cause the card to crash?
View 1 Replies
View Related
Apr 1, 2013
I have a cisco 6509 (ws-c6509-e) IOS 12.2.(18)SXF6 with the following modules and submodules: [code] I would like to add another module, I have WS-6816-GBIC or WS-6516-GBIC which one will work with my 6509 ? The 6509 has four module slots empty: 4-7-8-9, Can I add the card in one of these slots ?
View 10 Replies
View Related
Oct 21, 2012
How I can shutdown a module when I am running vsl.I can use the following command #hw-module module 2 shutdown.As I have modules in both switch 1 and switch 2 how can I ensure I only shut down module 2 in switch 1.
View 1 Replies
View Related
Mar 17, 2012
We have a VSS environment with two Cisco 6509-Es. IOS image:s72033-ipservicesk9_wan-mz.122-33.SXI5 when I switch on or reload the Core switches(VSS), I find a Minor Error in the "Show module switch all" command.I also did a "show diagnostic result switch 1 module 5"Switch 1 Module 5: Supervisor Engine 720 10GE (Active) SerialNo : SAL1521E035
Overall Diagnostic Result for Switch 1 Module 5 : MINOR ERROR
Diagnostic level at card bootup: complete
Test results: (. = Pass, F = Fail, U = Untested)
45) TestVslLocalLoopback:
Port 1 2 3 4 5
-------------------
U U U . F
This issue temporarily relieves when reseating the X2 module, but reappears after reloading the switch.
View 5 Replies
View Related
Jan 7, 2013
We have a requirement to build a datacenter within a datacenter for a new project. The existing Core network is 2 x Cisco 6509 in VSS configuration. We would like to connect the new datacenter to the existing Core switch from the new low-end Core switch. This datacenter would have a SAN network and blader chassis.
Listing the Cisco Switches requirements and expansion module requirements ?
- What expansion module is required at existing 6509 ? Can we have one 10Gibit modules on each switches and crate a port-channel connection from new datacenter core switch ?
- Which model of Switch you recommend for the new Datacenter Core which is only going to have one SAN Enclosure and two blade chassis? Will it be a good option to use 3750E ? If yes do we need any additional modules there ?
- Which aggregation switch should we use for the blade enclosure ?
- Should we have a Cisco Embedded Switch module on the chassis to create trunk with aggregation switch ?
- How the SAN director switch is connecting to the LAN ? should we have any particular module at new Core switch ?
View 0 Replies
View Related
Jun 8, 2011
I m planning to implement VSS in core but want some inputs on IOS as i have FWSM as a service module Core :- Ii am running 12.2(33)SXH2a on my Core 6509 and i checkd cisco sites and Fwsm release notes but it states only I-Train of IOS while mine is H-Train so can I directly upgrade to I-Train or I was thinking of SXH8b IOS.
View 2 Replies
View Related
Dec 7, 2011
We have two 6509 switches with one WS-X6704-10GE module in each of them. There is an optical cable between the two switches plugged in WS-X6704-10GE module on both sides. When you shut down the port on one side the other port still stays as up and you need phisycally to unplug the cable to have it down. The same behaviour is seen no matter on which of the two switches you shut down the port, the opposite one always stays as up and only removal of the cable makes it go down.
The ports are configured quite simply:
interface TenGigabitEthernet1/1
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1-10
no ip address
udld port
The IOS version is 12.2(18)SXF8
View 2 Replies
View Related
Sep 18, 2012
We have a design of two 6509 running in a VSS with dual supervisor each having fthree 10/100/1000mb etherner modules. We have diagnosed a wierd problem that none of the switchports in module 1 and 2 on either switches are having layer2/layer 3 connectivity.
Tried everything from changing the cables to changing the end device but no luck with it.
Module results show pass and no errors in the logging.
View 2 Replies
View Related
Jan 1, 2013
can I install and Cisco WAAS and Cisco Prime Network Analysis Module (NAM) together on a single Cisco Service-Ready Engine (SRE) 910 module? Or it can only run 1 of the software?
View 2 Replies
View Related
Nov 21, 2011
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports
x1 NAM
x2 Sup720
Running 12.2(18)SXF3
I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis?Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
View 2 Replies
View Related
Nov 21, 2011
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports
x1 NAM
x2 Sup720
Running 12.2(18)SXF3.I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis. Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
View 2 Replies
View Related
Jan 4, 2013
I am currently running a 4506 with a sup V engine. I have purchased a sup 7 engine. Is there a guide on how to perform this task. I am sure I need to do an IOS update as well.
View 2 Replies
View Related
Apr 18, 2013
i have a standalone SUP720, no traffic is passing through it. only one port connected for remote telnet, its kind of backup device.today i checked its log, and there are some wiered message.is it a software bug or my SUP has gone bad? [code]
View 24 Replies
View Related
May 6, 2013
We have a scenario with 2 chassis, both with 2 supervisor Engine 2T, we try to make a configuration of VSS with the chassis and would link to know if is possible have 2 supervisor on chassis one and 2 supervisors on chassis 2 with VSS?
Router#sho switch virtual redundancy
My Switch Id = 1
Peer Switch Id = 2
Last switchover reason = active unit removed
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso
[code]....
would like to use the second supervisors for obteind the local redundancy en chassis 1 and 2, this is possible?
the actually version on four supervisors is: s2t54-ipservicesk9-mz.SPA.150-1.SY3.bin
View 6 Replies
View Related
May 13, 2012
We recently perchaced 4503 switch with Sub Engine 7L. It has universal IOS. We are unable to run EIGRP and HSRP protocol and the switch came with temporal license.how to proceed further to get EIGRP and HSRP enabled on the 4503 switch.
View 8 Replies
View Related
Nov 3, 2011
I have an older 4006 with a Supervisor II+. We now need OSPF support, which the Sup II+ does not provide. I have access to a Supervisor III (WS-X4014), which will provide OSPF support. Question is, are there any gotchas to shutting down the switch, replacing Supervisor Engines and then powering up? What about the flash card? On my current system, it appears that I am only using bootflash: , which is where the IOS resides (see below). Since my startup config is in nvram and my IOS is in bootflash, what's the purpose of the flash card in slot0: ? and where does NVRAM and bootflash actually live on a 4006 ( on the Supervisor Engine?)
sh bootvar
BOOT variable = bootflash:cat4500-ipbase-mz.122-31.SGA11.bin,1;,1;
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist
[Code].....
View 5 Replies
View Related
Nov 28, 2011
we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]
View 1 Replies
View Related
Mar 8, 2012
I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
SWITCH-4507#sh ver
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version
12.2(25)EWA8, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 24-Jan-07 15:28 by pwade
[code]....
View 4 Replies
View Related
Oct 24, 2012
I buy a Cisco 4003 Switch with Supervisor Engine I but it only run CatOs and i whant it to run Cisco IOS so whitch Supervisor Engine can the Cisco 4003 Switch run? i have look at the Supervisor Engine III it can run Cisco IOS and Layer 3 but can i use that in my Cisco 4003 switch?
View 14 Replies
View Related
Apr 5, 2013
For C6500 chassis, sup-fould like to know the dirrerence between supervisor engiene 720 sup-bootflash and sup-bootdisk?
View 3 Replies
View Related
Mar 16, 2012
On an existing 4500 switch with a single sup 6-E, another sup 6-E is added. But the second sup6-E comes up as synchronised with active and in a few minutes time, reloads again. the software is 12.2(44) is the same on both sup engines. the redundancy sso output shows that slot6 is disabled.
View 1 Replies
View Related
Mar 27, 2013
I am having problems with IGMP and QoS on CAT6500 platform with SUP720 engine.The problem is, it seems that all IGMP packets are getting marked with DSCP 48 when sent out of the switch regardless of any input service policy. I found several articles saying that PFC QoS does not apply to IGMP packets. However in IOS 15 that should be possible, but I didn't get it to work there either. [code]
View 0 Replies
View Related