We have a VSS environment with two Cisco 6509-Es. IOS image:s72033-ipservicesk9_wan-mz.122-33.SXI5 when I switch on or reload the Core switches(VSS), I find a Minor Error in the "Show module switch all" command.I also did a "show diagnostic result switch 1 module 5"Switch 1 Module 5: Supervisor Engine 720 10GE (Active) SerialNo : SAL1521E035
Overall Diagnostic Result for Switch 1 Module 5 : MINOR ERROR
Diagnostic level at card bootup: complete
Test results: (. = Pass, F = Fail, U = Untested)
45) TestVslLocalLoopback:
Port 1 2 3 4 5
-------------------
U U U . F
This issue temporarily relieves when reseating the X2 module, but reappears after reloading the switch.
We are facing issue of having minor error for SUP module details below,SUP: WS-X45-SUP6-E see the minor error coming while troubleshooting this SUP 6-E error as below,
module 3: SerialNo :
Overall diagnostic result: MINOR ERROR#
Test results: (. = Pass, F = Fail, U = Untested)
1) supervisor-bootup ---------------> U 2) linecard-online-diag ------------> F
I have a pair of 6509-E Switches running VS-720 Supervisors. We are planning to add Ace Module onto the 6509-E. Will IP Base Image suffice the requirement? Will Ace Module work with only IP Base Image?
I have a switch Cisco WS-C6509-E WS-X6716-10G-3C module ( module for 10 GB) , i have the IOS s72033-ipservicesk9-mz.122-18.SXF9.bin. I want to know if this IOS can support this module or not ? or , if i must do a upgrade , is that the IOS : "s72033-ipservicesk9_wan-mz.122-33.SXH8" work fine ?
Suffered a big outage on the network, the fix was to reload the module 3 on the 6509 switch, we had these errors on the log %CONST_DIAG-SW1_SP-3-HM_PORT_TEST_FAIL: Switch 1 Module 3 TestUnusedPortLoopback Port(s)[24,46] failed. System operation continues.in the end, we reloaded the card and it was all ok. is there anything I can do to check the card / or any deeper logs? would that error cause the card to crash?
I have a cisco 6509 (ws-c6509-e) IOS 12.2.(18)SXF6 with the following modules and submodules: [code] I would like to add another module, I have WS-6816-GBIC or WS-6516-GBIC which one will work with my 6509 ? The 6509 has four module slots empty: 4-7-8-9, Can I add the card in one of these slots ?
How I can shutdown a module when I am running vsl.I can use the following command #hw-module module 2 shutdown.As I have modules in both switch 1 and switch 2 how can I ensure I only shut down module 2 in switch 1.
We have a requirement to build a datacenter within a datacenter for a new project. The existing Core network is 2 x Cisco 6509 in VSS configuration. We would like to connect the new datacenter to the existing Core switch from the new low-end Core switch. This datacenter would have a SAN network and blader chassis.
Listing the Cisco Switches requirements and expansion module requirements ?
- What expansion module is required at existing 6509 ? Can we have one 10Gibit modules on each switches and crate a port-channel connection from new datacenter core switch ?
- Which model of Switch you recommend for the new Datacenter Core which is only going to have one SAN Enclosure and two blade chassis? Will it be a good option to use 3750E ? If yes do we need any additional modules there ?
- Which aggregation switch should we use for the blade enclosure ?
- Should we have a Cisco Embedded Switch module on the chassis to create trunk with aggregation switch ?
- How the SAN director switch is connecting to the LAN ? should we have any particular module at new Core switch ?
I m planning to implement VSS in core but want some inputs on IOS as i have FWSM as a service module Core :- Ii am running 12.2(33)SXH2a on my Core 6509 and i checkd cisco sites and Fwsm release notes but it states only I-Train of IOS while mine is H-Train so can I directly upgrade to I-Train or I was thinking of SXH8b IOS.
We are facing a strange issue, our ACE 20 got failed due to power issue , after RMA once we are installing ACE 20 to 6509 , the status LED is showing ORANGE . The sh module shows it as " Others " ... The IOS is same as it was previously in 6509 .
We have two 6509 switches with one WS-X6704-10GE module in each of them. There is an optical cable between the two switches plugged in WS-X6704-10GE module on both sides. When you shut down the port on one side the other port still stays as up and you need phisycally to unplug the cable to have it down. The same behaviour is seen no matter on which of the two switches you shut down the port, the opposite one always stays as up and only removal of the cable makes it go down.
The ports are configured quite simply:
interface TenGigabitEthernet1/1 switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 1-10 no ip address udld port
We have a design of two 6509 running in a VSS with dual supervisor each having fthree 10/100/1000mb etherner modules. We have diagnosed a wierd problem that none of the switchports in module 1 and 2 on either switches are having layer2/layer 3 connectivity.
Tried everything from changing the cables to changing the end device but no luck with it.
Module results show pass and no errors in the logging.
I had a problem during setup of a new module N7K-M148GS-11 into a Nexus 7000 10-Slot chassis.The module was powered-dn and removed by platform with the following message: [code]
Do I need to upgrade nx-os? There is a workaround?
I've got a pair of N7010's in a vPC domain with some FEX's attach running NX-OS 6.0.2. I am experiencing port failures on my N7K-M132XP-12L module the port got shut down due to internal errors with Error Disabled status and I am not able to bring the port back up. I am getting the following errors when I try to reset it. I am hoping is not hardware related as my vPC peer-link is on this module and I only have a single N7K-M1 32 XP-12L in each N7010. Replacing the module will be painful. [code]
Cisco IP phones attached to a Moduke in one of my Cat6500 access Switches suddenly went down. Upon closer inspection of the Switch Sys log, I observed the following Sys log error messages: [Module 9 is experiencing the following error: Inline Power Module - PS Voltage bad. ]A sh Mod output indicates the PoE daughter card and Main Module are "ok" - see attached output. It appears issue is related to the the actual Power Supply module and not the blade module and installed PoE Daughter card. I am inclined to open a TAC case for a PS replacement, but wanted to see if this can be resolved without a hardware replacement. At this time all 48 IP phones attached to this module are out of Service.
I have a Cisco catalyst 6513 with sup720-3bxl and WS-X6724-SFP modules , the switch was working fine until yesterday ,but after a maintenance the modue WS-X6724-SFP failed to bring online , the error code is (Module Failed SCP dnld) does it mean the module has hardware problem or i need to replace it ?
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ios version s72033-adventerprisek9_wan-vz.122-33.SXH7.bin ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- show module Mod Ports Card Type Model
I am receiving this error after connecting a copper adapter on a GBIC blade in a 6509. Here are the results from the show Interface. I am waiting to confirm the device on the other side settings but as far as I see I get UP and Up for protocol and line respectively.
GigabitEthernet2/11 is up, line protocol is up (connected) Hardware is C6k 1000Mb 802.3, address is 0009.11e4.f3ce (bia 0009.11e4.f3ce) Description: RCPBSDEV MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set
There is a cisco ws-c6509,recently it appear error log “%FABRIC-SP-6-TIMEOUT_ERR: Fabric in slot 5 reported timeout error for channel 11 (Module 3, fabric connection 1)”. When I reload the device,the error log disappear.But a few days later,it appears again.I try to replace the slot 3 (WS-X6704-10GE),the error log continues.The IOS version is 's72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(18)SXF8"
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports x1 NAM x2 Sup720 Running 12.2(18)SXF3
I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis?Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports x1 NAM x2 Sup720
Running 12.2(18)SXF3.I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis. Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
The router 1841 is connected directly to the layer switch. the network diagram is below:
Office A --> Switch (L3) --> Router 1841 --> Internet --> Office B
However, when I transfer the file from Office A to office B, the speed very slow ( only around 40 kb/second), and there are an input error and CRC error:
Cisco-R1841#sh interfaces FA0/1 FastEthernet0/1 is up, line protocol is up Hardware is Gt96k FE, address is 0019.e02f.03dd (bia 0019.e02f.03dd)
We have a 6509-e (WS-C6509-E V04) with (4) (WS-X6148-GE-TX) 48 port modules and a supervisor 32 (WS-SUP32-GE-3B).We purchased a supervisor 720 (WS-SUP720-3B) and (2) (WS-6708-10G-3C) 8 port fiber modules and (1) WS-X6748-GE-TX)48 port module to add to the switch. My question is what is the best way to swap out the supervisor module? Can the SUP720 be added as a standby module so that the config can be transferred? Probably a long shot. Is there anything in this swap that I should be concerned with? The other three modules should be pretty straight forward.
we have two 6509 catalyst. we bought two new SFM-capable 16 port 1000mb GBIC/WS-X6516A-GBIC module. but our catalysts doesnt support them. we don't know the reason. we tried on another 6500 series catalyst they worked.
here are the outputs from our 6509:
Core-SW-1#sh module Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ ----------- 1 0 1-subslot SPA Interface Processor-600 7600-SIP-600 JAE14090958 2 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL1413DX2B 3 16 CEF720 16 port 10GE WS-X6716-10GE SAL1414EL2Q 4 1 Application Control Engine Module ACE20-MOD-K9 SAD1408036Z 5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1414ERDT 6 5 Supervisor Engine 720 10GE (RPR-Warm) VS-S720-10G SAL1414ERE3 7 16 CEF720 16 port 10GE WS-X6716-10GE SAL1414ER93 8 16 SFM-capable 16 port 1000mb GBIC WS-X6516A-GBIC SAL1326SVBS(code)
I try to access to WS-SVC-NAM-2 module in the Switch 6509. But is not work although the HTTP port is enabled (I tested with the command telnet @ip 80).
I try telnet access to the module to check the config , but I always the message that the lo gin / password is wrong even though they are valid.
Need to remove the IPSec VPN SPA module from the 6509 chassis. Does the module is hot swappable or does the 6509 need to be turned off prior to removal.
We have a 6509 with an ACE module. For reasons I don't fully understand the ACE is running using a BVI in bridge mode. It has loads of secondary interfaces.
[Code]...
I can ping all of the IPs on the BVI, but only servers in Subnet 10.7.42/42 can ping out of the the layer 3 on the 6509. I have all the routes configured properly on the 6509 pointing to the ACE for these subnets. The question is though the config has been excepted, is there a limit to the number of secondary on a BVI.
I have a cisco 6509 configured with a cisco NAM module. I have reset the config of the NAM module by the config clear command. Since this moment I can't no more ping the NAM module via the management port: OK via the 127.0.0.91 address and log in ok via the ios cli session command. [code] I have already tried to reboot the module via the ios cli hw module command and nothing better.
I am desiging a topology with two Cat 6509 and Two ACE Module, one ACE per Catalyst. I am thinking to use bridge mode for the customer contexts, I would like to know if the Bridged mode is an Assymetric topology.
The server gateway is the ip address of the ACE or the Router?
I trying configure ASN traffic load balance, but doesn't works.I have one Cisco Catalyst 6509 and onde Cisco Ace10 module, in my context "PanWEB" i have the interfaces above: [code] If i try to establish a telnet session(telnet 10.96.202.10 80) i see the SYN packet passing through the ACE and going to the real server, but, the server do not response the SYN packet. I done a capture in the server using wireshark and could see that the IP address of the destination is the VIP and not the rserver ip address , this is a problem? Why can not I have the SYN + ACK from the server?