Cisco Switching/Routing :: 6509 - Fabric In Slot 5 Reported Timeout Error For Channel 11

Apr 27, 2013

There is a cisco ws-c6509,recently it appear error log “%FABRIC-SP-6-TIMEOUT_ERR: Fabric in slot 5 reported timeout error for channel 11 (Module 3, fabric connection 1)”. When I reload the device,the error log disappear.But a few days later,it appears again.I try to replace the slot 3 (WS-X6704-10GE),the error log continues.The IOS version is 's72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(18)SXF8"

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: 6509 Trunk To Port Channel

Apr 22, 2012

I have 2 Cisco 6509 switches linked together via single Fibre as a trunk.I want to change this to a port channel where I will add another 3 fibre ports to the port channel but what order do I do this to minimise any disruption.

1-Configure PortChannel and add the 3 new ports, this will bring up the Port Channel but what effect will this have on traffic currently going over the single Trunk link? Will spanning tree go mad, how will switches react?

2-Convert existing Trunk link to Portchannel then add in new ports to PortChannel, I guess in doing this there will be a small hit on traffic as it changes to a port channel.

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 6509 - Ether Channel Configuration?

Dec 1, 2011

I came across a Catalyst 6509 switch configuration and have noticed some strange thing on the ether channel configuration side, it appears that it have interface port-channel 2 and port-channel 2A, what was that mean? its the ether channel not forming and joined together?
 
What wrong with the below configuration that cause it to automatic created another port-channel (2A) interface in this case?

[code]...

View 3 Replies View Related

Cisco Switching/Routing :: Getting DHCP Timeout Error On 6500

May 8, 2013

i have this message "DHCP Timeout"on few cisco IP Phones . try to assign IP manually and it's working fine.. seems DHCP not giving IP's to those.. 6500 have configured as DHCP pool.

View 3 Replies View Related

Cisco Switching/Routing :: 6509-E Switches Interconnected On Layer 3 Port Channel

Oct 3, 2012

We are currently designing  Layer 3 to the edge EIGRP solution  for our customers. The network is a hybrid of collapsed  core (Core to access) as well as a three layer design (Core/Distro/Access) for connectivity to the Data Centre, Internet, Wireless Blocks etc.The  core of the network contains two 6509-E switches interconnected on a  Layer 3 Port channel (no VSS). Access Layer switches (3750-X series running Stackwiseplus protocol)  connect to the core switches over p2p routed links and Distribution layer switches (3750X stackwiseplus) provide connectivity to the  Data centre, Internet, wireless blocks etc.
 
The access and distribution switch stacks(Cisco 3750-X) are set up with two or three member switches with uplinks multihomed to the primary and secondary core switch with each uplink included in EIGRP. In each of the stacks, one of the switches controls the operation of the stack, which will be  the stack master.As the Cisco Stackwise architecture is not SSO-capable but NSF aware, all Layer 3 fuctions must be re-established during a master switch outage. To minimize control plane impact and improve Layer3 convergence, uplinks should be diverse and originate from the member switches instead of the Master switches in the respective stack. This is as per Cisco recommended design solution.The above solution can be setup if there are more than two switches in the stack. i.e. uplinks are configured on the backup member switch modules.
 
1.But what about stack with two switches..Which switch should be set up as the Master for a two member stack with uplinks to the core primary and secondary from each switch(Master and Backup)
 
2. For Layer 3 routing, does the routing takes precedene over switch failures? Say for eg. In a two member stack, the master switch with uplink to primary fails, does EIGRP provide a fast convergence to route traffic via backup secondary and does not wait for the control plane on the switch stack to converge? All the access to core links will be set up for ECMP.

View 3 Replies View Related

Cisco Switching/Routing :: 6509 / Layer 3 Port Channel Between Sites Connected Over Dark Fiber?

May 21, 2013

Has anyone configured Layer 3 port channel on Cisco 6509 switches which are connected over dark fiber between two buildings?

View 3 Replies View Related

Cisco Switching/Routing :: 3750X Channel-misconfig Error Detected

Jun 21, 2011

I have two 3750Xs for stack, and i want connect a 2960 switch on this stack with port-channel.I connect 2960 G0/1 to 3750X G1/0/24, and 2960 G0/2 to 3750X G2/0/24. [code] i try to config spanning-tree etherchannel guard misconfig, but no use finally, i have to use  "no errdisable detect cause all"..i check the cisco.com, and find a information: for this case, channel-group can use mode desirble.but when i try to change the channel-group in 3750X stack, it shows me that: "with pagp enable, desirble mode must config in the same switch".i try to use mode desirble mode in G1/0/23 and G1/0/24 in 3750X stack, it still can not work.i want to know how to solve this problem? not only do "no errdisable detect cause all".

View 11 Replies View Related

Cisco Switching/Routing :: C3500 XL Version IOS 12.0 / Error Add Interface Port-channel

Jan 15, 2012

a Customer ask me  to configure a etherchannel between two Switches C3500 XL Version IOS 12.0 follow the first configuration what I done and the output error show me by switch:

Sw01(conf)# interface port-channel 1  % invalid input detected at '^'  marker.   

I have to do something before add an new port-channel interface ?? why the Sw01 does not accept my configuration ?

View 3 Replies View Related

Cisco Switching/Routing :: CatOS C6000 / Spanning Tree Channel Loop Error?

May 15, 2013

I'm trying to configure an LACP channel trunk between a CatOS C6000 and a Dell PowerConnect.
 
I use mode active in both sides and it works great.
 
But, when I connect a Catalyst 3750X to the Dell PowerConnect the channel between C6000 and PWC shutdown:
 
2013 May 16 09:08:20 CEST +02:00 %SPANTREE-2-CHNMISCFG: STP loop - channel 5/19-20 is disabled in vlan/instance 20
 
2013 May 16 09:08:20 CEST +02:00 %SPANTREE-2-CHNMISCFG2: BPDU source mac addresses: 00-04-6d-43-a4-e2, 70-ca-9b-27-46-99

View 3 Replies View Related

Cisco Switching/Routing :: Getting Error Logs In 6509?

Feb 3, 2012

%SYSTEM_CONTROLLER-SP-3-ERROR: Error condition detected: TM_DATA_PARITY_ERROR Feb 2 10:57:09.602 EST: %SYSTEM_CONTROLLER-SP-3-EXCESSIVE_RESET: System Controller is getting reset so frequently
Cisco Internetwork Operating System Software
IOS (tm) s222_rp Software (s222_rp-IPSERVICES_WAN-M), Version 12.2(18)SXF15a, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2008 by cisco Systems, Inc.
Compiled Mon 20-Oct-08 19:20 by kellythw
Image text-base: 0x40101040, data-base: 0x42951080

[code]....

View 1 Replies View Related

TCP / IP CP Reported Error 738?

Aug 17, 2011

I have two computers connected to DSL with a modem and a 4 port ethernet switch.Only one computer is on the switch at the moment because the other is getting parts repaired. About a month or two ago, we had problems with our ISP because the main tower in town was having work done so connections were spotty.With the work being done for a month, I've still been having problems and I am not sure if it's related to my ISP or modem/ethernet port or what. I got this error when connecting: TCP/IP CP reported error 738: the server did not assign an address. It took around 10 redials for it to connect. I've gotten this error before (along with other errors I don't recall as it's been awhile) and my internet will randomly slow way down.

I just had an svchost.exe error that I got resolved via the techsupportforum virus section, where my computer would freeze when trying to connect, and I hadn't had any connecting errors for awhile. But now that the infections are gone, I am getting errors again. It seems quite odd.I rent a modem from my ISP and it stopped working before so I got a new one. They said I had hit the reset button on their modem and that was probably my problem and could have also messed up my ethernet switch. So I'm wondering if that is an issue also, as I am using the same switch with a new modem.

View 4 Replies View Related

Cisco Switching/Routing :: 6509 - Cannot Find Reference To Error

Mar 5, 2010

This is a 6509 with Sup-2/MSFC2.  Can't find any reference to this error on the cisco web site.

View 2 Replies View Related

Cisco Switching/Routing :: Cat 6509 - VSS - Minor Error (Sup Module)

Mar 17, 2012

We have a VSS environment with two Cisco 6509-Es. IOS image:s72033-ipservicesk9_wan-mz.122-33.SXI5 when I switch on or reload the  Core switches(VSS), I find a Minor Error in the "Show module switch all" command.I also did a "show diagnostic result switch 1 module 5"Switch 1 Module 5: Supervisor Engine 720 10GE (Active)  SerialNo : SAL1521E035

Overall Diagnostic Result for Switch 1 Module 5 : MINOR ERROR
Diagnostic level at card bootup: complete
Test results: (. = Pass, F = Fail, U = Untested)
45) TestVslLocalLoopback:
Port  1  2  3  4  5
-------------------
U  U  U  .  F
 
This issue temporarily relieves when reseating the X2 module, but reappears after reloading the switch.

View 5 Replies View Related

Cisco WAN :: 3845 Fan Failed - Error Reported

Feb 27, 2012

In my head office we have Cisco 3845 router.in the router we put the show log command the below error is came..
 
What is the error??why the error came??
 
25024684: Feb 29 10:33:13.759 India: %FAN-3-FAN_FAILED: Fan 1 had a rotation error reported.
25024685: Feb 29 10:33:33.759 India: %FAN-3-FAN_FAILED: Fan 1 had a rotation error reported.
25024686: Feb 29 10:33:53.759 India: %FAN-3-FAN_FAILED: Fan 1 had a rotation error reported.
25024687: Feb 29 10:34:13.759 India: %FAN-3-FAN_FAILED: Fan 1 had a rotation error reported.

View 2 Replies View Related

Cisco Switching/Routing :: 6509 / Mac Address Error Message No Entries Present

Dec 6, 2012

I am receiving this error after connecting a copper adapter on a GBIC blade in a 6509. Here are the results from the show Interface.  I am waiting to confirm the device on the other side settings but as far as I see I get UP and Up for protocol and line respectively.
 
GigabitEthernet2/11 is up, line protocol is up (connected)
Hardware is C6k 1000Mb 802.3, address is 0009.11e4.f3ce (bia 0009.11e4.f3ce)
Description: RCPBSDEV
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: 6500 Switching Fabric Bandwidth 720 Is Calculated?

Jan 21, 2012

As per my understanding 6509 all slots are dual channel, so 9 slot * 40 per slot (20 g in and 20 g out) = 360 GB How cisco claim the 720 ?? What about the 6513 chassic switch fabric connection?

View 5 Replies View Related

Cisco Switching/Routing :: Switching Fabric And Forwarding Rate C3750x

Aug 6, 2012

It is said that the switching fabric of WS-C3750X-24T-E is 160Gbps.Could any body tell me what is switching fabric, any relevance or difference from forwarding rate?,Is there any document to know how will the switch reach the 160Gbps full switching fabric performance?

View 5 Replies View Related

Cisco WAN :: 3725 Router - Fans Had Rotation Error Reported

Jan 14, 2008

I have a 3725 router that is reporting the following syslog message:  

%FAN-3-FAN_FAILED: Fans had a rotation error reported.
 
When I do a show environment all, I am getting the following message:  

Fan status: Warning- low fan rpm condition detected.
 
Both the the fans are functional and are rotating fine. How do I repair?

View 6 Replies View Related

Cisco Switching/Routing :: High Fabric Utilization On 3560-e

Nov 2, 2010

I am looking at the utilization on a Catalyst 3560-E.  I am running a test with eight 1 GIGE links RXing at 95 % utilization.  All of the traffic is going to a TenGigE port.  The device on the TenGigE port is echoing back all of the traffic received, so the 1 GIG links are TXing at 95% as well.When I do a "show controllers utilization", the port utilization numbers are correct, but the fabric utilization is higher than I would expect.  The fabric should be 128 gigbits / second in this switch, and there is 7.6 gigabits TX/RX to the ten gig port.  The fabric utilization is at 49%.  I would expect 7.6 / 128 = 5.9% or possible double that. [code]

View 8 Replies View Related

Cisco Switching/Routing :: Nexus 55548UP - 1GE SFP Module Not Recognized In Fabric Extender

Oct 17, 2012

we installed copper and fiber sfp modules in the 2232PP and none would link up. we pulled the sfp modules out and entered the speed 1000 command and re-inserted the module with no success. the same sfp modules works fine in every other cisco device. we must be missing something. running latest nx-os software.
 
COH-Nexus-02# sh int Eth101/1/1 status
--------------------------------------------------------------------------------
Port          Name               Status    Vlan      Duplex  Speed   Type
--------------------------------------------------------------------------------

[Code].....

View 4 Replies View Related

Cisco Switching/Routing :: Using SD Card Slot On ME3600X

Mar 13, 2013

we are trying to use the SD Card Slot on an Cisco ME3600X (ME-3600X-24FS-M) IOS Version 15.2(4)S2. If i try to copy a file from the sd card slot to the flash there is no Option like "slot0:" or something alse and no syslog message appers while adding the SD Card.

View 5 Replies View Related

Cisco Switching/Routing :: Nexus 5548UP With 2232TM Fabric Extender And Server Teaming

Oct 11, 2012

Need clarification on the VPC with 5k and 2248 Fabric Extenders. My question  is can each fabric extender uplink to two different 5ks, and  at the same time, have servers connected to two both fabric extenders with a VPC.So basically, the server NIC will team with two different fabric extenders, and each fabric extender will connect to two different 5k's.

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 2232 Feature - Connect To Switch Like HP Flex Fabric

Aug 22, 2012

As per my understanding, Cisco Nexus 2232 can only connect to HP c7000 Chassis if we are using a Pass Through Switch in the HP c7000. Cisco Nexus 2232 can only connect to End Hosts and not to a switch. Is there a New Feature added in Nexus 2232, which enables it to connect to a Switch like HP Flex Fabric ?

View 1 Replies View Related

Cisco Switching/Routing :: How To Properly Power Down Nexus 5000 And Fabric Interconnect Switches

May 7, 2013

How to properly power down the Nexus 5000 and the fabric interconnect switches? I have looked up and down cisco's and google web for steps, but they are all coming back with the answer to just disconnect the power cables after you have power down all the windows os and exs servers. Before i do that, I just wanted to make sure that that's the correct way to do it or if there are actual commands that I will need to run on the devices to properly power down. I know that the FI do have a command to reboot, but i need them to completely be power down.

View 3 Replies View Related

Cisco Switching/Routing :: WS4500 Eseries With 3 - Slot Chassis?

Dec 31, 2011

Every one i want to know ws-c4503E series 3 -slot chassis . I have compatibility issues with MEM-C4K-FLD64M AND S45EIPBK9-12240SG will work.

View 2 Replies View Related

Cisco Switching/Routing :: Ejector Open On Slot 19 On Nexus 7018

Jan 15, 2013

I've got this syslog alarm from nexus 7018. I am wondering what the slot 19 is here.
  
2013 Jan 15 23:59:22 r1 %PLATFORM-3-EJECTOR_STAT_CHANGED: Ejectors' status in slot 19 has changed, Top Ejector is OPEN, Bottom Ejector is CLOSE
2013 Jan 15 23:59:24 r2 %PLATFORM-3-EJECTOR_STAT_CHANGED: Ejectors' status in slot 19 has changed, Top Ejector is CLOSE, Bottom Ejector is CLOSE

View 5 Replies View Related

Cisco Switching/Routing :: Command To Check Memory Slot In 3800 Routers?

Nov 13, 2011

I remember there is one command which can tell you which memory slot has how much big memory in Cisco 2800 or 3800. But at this moment, I just couldn't recall this command. I checked "show diag" but didn't see any information about memory.

View 9 Replies View Related

Cisco Switching/Routing :: 4510R L3 / Make Active Sup6 In Slot 6 Which Is Currently Standby Sup In Chassis

Mar 25, 2013

I have cisco 4510R L3 switch with installed 2 Sup on slot 5 and 6. the current active Sup is in Slot5 i want to make active Sup6 in slot 6 which is currently standby sup in chassis. Is there any way to make standby Sup to ACTIVE without reloading any of the Supervisor. however there is two way as per my understanding -

1. we can reload the active Sup so that standby Sup will take charge. - (redundancy reload shelf)

2. we can focefully switchover the state of Sup's by (redundancy forcefully swithover) but in above both cases reload will be performed by one of the supervisor. which i don't want.

View 2 Replies View Related

Cisco Switching/Routing :: What S The Fabric Speed (backplane Speed) Of A Nexus 2232 10G EX

Jan 12, 2013

What s the fabric speed (backplane speed) of a Nexus 2232 10G EX?What is the forwarding rate (Mpps) of the same 2232 FEX? 

View 6 Replies View Related

Cisco Switching/Routing :: Nexus 7000 With Fabric Extenders Nexus 2000?

Mar 15, 2013

I have been tasked to replace the existing Cat 6500 and 3750 switches by Nexus 7000 and Nexus 2000.I was told initially my boss plans to get 2 x Nexus 7000 and then eventually blow up to 4 x Nexus 7000s.For Nexus, is there a list of tasks / points that i need to consider for building the initial design?
 
Can i just link the Nexus 7000 like the following?
 
N7k-A    =========   N7k-B
|                                   |           
lots of N2ks               lots of N2ks

View 12 Replies View Related

Cisco Switching/Routing :: 6509 To 6509-E Chassis Upgrade?

Nov 21, 2011

I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:

     x3     48 ports
     x1     NAM
     x2     Sup720
     Running 12.2(18)SXF3
 
I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis?Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?

View 2 Replies View Related

Cisco Switching/Routing :: Upgrade Of 6509 To 6509-E Chassis

Nov 21, 2011

I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:

x3     48 ports
x1     NAM
x2     Sup720

Running 12.2(18)SXF3.I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis. Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?

View 2 Replies View Related

Cisco Firewall :: ASA5580 Port Channel To 6509 VSS?

Dec 17, 2012

Anyway, here's the situation I'm trying to configure several VLANs on my ASA to uniquely allocate to contexts, the VLANs will be trunked from my VSS. Unfortunately I'm not clear on how to achieve this, the configuration guide for 8.4 talks about multiple contexts and routed setups all which don't appear to apply exactly. I've configured the port channel at both ends and I've configured sub-interfaces on the port channel and assigned VLAN IDs. These sub-interfaces are then allocated to the contexts to set 'ip address' etc. I've not been able to successfully test this configuration and I am concerned that it is incorrect..

View 1 Replies View Related