Cisco Switching/Routing :: 6509 Shuts Down Module While Running VSL
Oct 21, 2012
How I can shutdown a module when I am running vsl.I can use the following command #hw-module module 2 shutdown.As I have modules in both switch 1 and switch 2 how can I ensure I only shut down module 2 in switch 1.
View 1 Replies
ADVERTISEMENT
Sep 10, 2012
I have a pair of 6509-E Switches running VS-720 Supervisors. We are planning to add Ace Module onto the 6509-E. Will IP Base Image suffice the requirement? Will Ace Module work with only IP Base Image?
View 1 Replies
View Related
Mar 4, 2012
I have a switch Cisco WS-C6509-E WS-X6716-10G-3C module ( module for 10 GB) , i have the IOS s72033-ipservicesk9-mz.122-18.SXF9.bin. I want to know if this IOS can support this module or not ? or , if i must do a upgrade , is that the IOS : "s72033-ipservicesk9_wan-mz.122-33.SXH8" work fine ?
View 7 Replies
View Related
Feb 15, 2011
I've upgraded a 6509 switches wich are running in VSS, from IOS 12.2 (33)SHI1 to 12.2 (33)SHI5. After that I'm facing the folowing log messages periodically. [code] I know that this is a diagnostic result from TestUnusedPortLoopback feature. But this interface is disabled (shutdown).
View 5 Replies
View Related
Apr 2, 2013
I am trying to convince our Technical Lead that dual VSL links between our 6509-E chassis is a VERY good idea but he is fully convinced that the setup will work perfectly fine with only one VSL link. As I do agree that we can do this, I am looking for more concrete evidence that shows this would be a bad setup.
I know that we will lose the High Availably that comes with VSS, what I don't know is what will happen to all of the downstream switches that are connected and what will happen to the two 6509-E chassis..
View 5 Replies
View Related
Jul 31, 2012
Suffered a big outage on the network, the fix was to reload the module 3 on the 6509 switch, we had these errors on the log %CONST_DIAG-SW1_SP-3-HM_PORT_TEST_FAIL: Switch 1 Module 3 TestUnusedPortLoopback Port(s)[24,46] failed. System operation continues.in the end, we reloaded the card and it was all ok. is there anything I can do to check the card / or any deeper logs? would that error cause the card to crash?
View 1 Replies
View Related
Apr 1, 2013
I have a cisco 6509 (ws-c6509-e) IOS 12.2.(18)SXF6 with the following modules and submodules: [code] I would like to add another module, I have WS-6816-GBIC or WS-6516-GBIC which one will work with my 6509 ? The 6509 has four module slots empty: 4-7-8-9, Can I add the card in one of these slots ?
View 10 Replies
View Related
Mar 17, 2012
We have a VSS environment with two Cisco 6509-Es. IOS image:s72033-ipservicesk9_wan-mz.122-33.SXI5 when I switch on or reload the Core switches(VSS), I find a Minor Error in the "Show module switch all" command.I also did a "show diagnostic result switch 1 module 5"Switch 1 Module 5: Supervisor Engine 720 10GE (Active) SerialNo : SAL1521E035
Overall Diagnostic Result for Switch 1 Module 5 : MINOR ERROR
Diagnostic level at card bootup: complete
Test results: (. = Pass, F = Fail, U = Untested)
45) TestVslLocalLoopback:
Port 1 2 3 4 5
-------------------
U U U . F
This issue temporarily relieves when reseating the X2 module, but reappears after reloading the switch.
View 5 Replies
View Related
May 2, 2012
Can we put a module on a 4507R switch running on a live production? The module will come from a 4506 switch.
View 8 Replies
View Related
Feb 21, 2012
in my 6509 switch while i checked is showing some thing like this RDCCI65F0#sh environment
environmental alarms:
no alarms
backplane:
operating clock count: 2
[Code].....
View 2 Replies
View Related
Jan 7, 2013
We have a requirement to build a datacenter within a datacenter for a new project. The existing Core network is 2 x Cisco 6509 in VSS configuration. We would like to connect the new datacenter to the existing Core switch from the new low-end Core switch. This datacenter would have a SAN network and blader chassis.
Listing the Cisco Switches requirements and expansion module requirements ?
- What expansion module is required at existing 6509 ? Can we have one 10Gibit modules on each switches and crate a port-channel connection from new datacenter core switch ?
- Which model of Switch you recommend for the new Datacenter Core which is only going to have one SAN Enclosure and two blade chassis? Will it be a good option to use 3750E ? If yes do we need any additional modules there ?
- Which aggregation switch should we use for the blade enclosure ?
- Should we have a Cisco Embedded Switch module on the chassis to create trunk with aggregation switch ?
- How the SAN director switch is connecting to the LAN ? should we have any particular module at new Core switch ?
View 0 Replies
View Related
Jun 8, 2011
I m planning to implement VSS in core but want some inputs on IOS as i have FWSM as a service module Core :- Ii am running 12.2(33)SXH2a on my Core 6509 and i checkd cisco sites and Fwsm release notes but it states only I-Train of IOS while mine is H-Train so can I directly upgrade to I-Train or I was thinking of SXH8b IOS.
View 2 Replies
View Related
Oct 4, 2012
We are facing a strange issue, our ACE 20 got failed due to power issue , after RMA once we are installing ACE 20 to 6509 , the status LED is showing ORANGE . The sh module shows it as " Others " ... The IOS is same as it was previously in 6509 .
View 2 Replies
View Related
Dec 7, 2011
We have two 6509 switches with one WS-X6704-10GE module in each of them. There is an optical cable between the two switches plugged in WS-X6704-10GE module on both sides. When you shut down the port on one side the other port still stays as up and you need phisycally to unplug the cable to have it down. The same behaviour is seen no matter on which of the two switches you shut down the port, the opposite one always stays as up and only removal of the cable makes it go down.
The ports are configured quite simply:
interface TenGigabitEthernet1/1
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1-10
no ip address
udld port
The IOS version is 12.2(18)SXF8
View 2 Replies
View Related
Jan 14, 2013
I'm working at a company that has several 6509 switches running CatOS. They have two of the 6509's running in vtp server mode and the rest as clients. I set up a new vlan from one of the vtp servers and it propagated out. The problem comes when I try to assign a port on one of the vtp clients to this new vlan. It gives me an error that the switch must be in vtp server mode to add/delete vlans. I'm not trying to add/or delete a vlan just trying to add a port into an existing vlan. I'm hesitant to put the switch in vtp server mode. Is this a CatOS thing or is there a specific command to accomplish this?
View 5 Replies
View Related
Sep 18, 2012
We have a design of two 6509 running in a VSS with dual supervisor each having fthree 10/100/1000mb etherner modules. We have diagnosed a wierd problem that none of the switchports in module 1 and 2 on either switches are having layer2/layer 3 connectivity.
Tried everything from changing the cables to changing the end device but no luck with it.
Module results show pass and no errors in the logging.
View 2 Replies
View Related
May 7, 2013
One of our customer , where there 2 6509 switch , one is Core_sw1 and other is Core_sw2 , catering about 32 Vlan , and HSRP in running for all Vlans , till here no problem , now there internet Router which having one Internet link , which connected and configured on Core_sw1 in a way that one interface of Core_sw1 is given Public IP and there is vlan 85 which internet vlan and vlan 85 ip are natted with that public IP with one simple static route given toward internet router , this is how internet is working ok.
Now i have configured vlan 85 in hsrp as all other are , how can give redundancy to vlan 85 user , that if Core_sw1 get down , internet traffic can get out through Core_sw2.using same internet router with single internet link .i am not talking of ISP redundancy , but Vlan 85 in Core_sw1 goes down , other Core_sw2 will server internet.
View 1 Replies
View Related
Feb 21, 2013
I have just configured a new RV016. Everything works well for about an hour then it shuts off. Cycling the power will cause the system led to light breifly, but then it shuts off again. After 15 minutes unplugged, I am able to restart it and it will run fine for about an hour.
View 2 Replies
View Related
Sep 3, 2008
I have a 892 router configured on fa0 with vlan1 and a catalist 3560. On catalist all ports are in access mode and vlan1. When I'm connecting port fa0 from router to catalist, the catalist port is shuted down What should I do on router on catalist to make the connection working ?
View 4 Replies
View Related
Jun 6, 2013
I recently installed a cisco 2901 router. The router is connected to hosts using a SG 200-50 50-Port Gigabit Smart Switch
Problem is the router internal interface keeps shutting down without notice and randomly. At that time I cannot ping the interrface from a LAN PC even though I can ping other hosts on the LAN. The ISP link is okay since I can put a static IP on my computer and access the net.
View 8 Replies
View Related
Mar 23, 2013
WAN link plugs into a 2821 Router with an switch module in it. About 8 clients are plugged in to the 2821.2821 connects to super cheap netgear switch (I'm 99% sure it's stripping dot1q headers) via one of the ports in the switch module. About 4 people are connected to the netgear.Now, I sent a catalyst 3560g to the branch because they wanted to extend into a new building. Someone decided to run a single cable from the netgear to the 3560. On the 3560, I have about 5 clients and a couple of APs.
So it goes 2821 -> Netgear -> 3560. All of these are single connections.When the 3560 gets plugged in, all clients on the netgear lose their connection, and nothing on the 3560 works. It happens almost instantly. I can't figure out why connections are dropping. The APs have about 4 VLANs onn them, and the PCs are on their own VLAN (the native VLAN).
View 3 Replies
View Related
Nov 21, 2011
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports
x1 NAM
x2 Sup720
Running 12.2(18)SXF3
I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis?Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
View 2 Replies
View Related
Nov 21, 2011
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports
x1 NAM
x2 Sup720
Running 12.2(18)SXF3.I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis. Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
View 2 Replies
View Related
Aug 13, 2012
I'm trying to enable port security on several 4507R's. When I try to configure a range of ports the switch will randomly put 1 or 2 in err-disable. It's different every time I apply the config to the same group of ports. However if I do them one at a time it seems to work. But I really don't want to configure 6 fully populated switches one port at a time. We also have a lot of 3750's and they gave me no problem using a port range. [code]
View 4 Replies
View Related
Mar 28, 2012
We have a 6509-e (WS-C6509-E V04) with (4) (WS-X6148-GE-TX) 48 port modules and a supervisor 32 (WS-SUP32-GE-3B).We purchased a supervisor 720 (WS-SUP720-3B) and (2) (WS-6708-10G-3C) 8 port fiber modules and (1) WS-X6748-GE-TX)48 port module to add to the switch. My question is what is the best way to swap out the supervisor module? Can the SUP720 be added as a standby module so that the config can be transferred? Probably a long shot. Is there anything in this swap that I should be concerned with? The other three modules should be pretty straight forward.
View 4 Replies
View Related
Jul 31, 2012
we have two 6509 catalyst. we bought two new SFM-capable 16 port 1000mb GBIC/WS-X6516A-GBIC module. but our catalysts doesnt support them. we don't know the reason. we tried on another 6500 series catalyst they worked.
here are the outputs from our 6509:
Core-SW-1#sh module
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 0 1-subslot SPA Interface Processor-600 7600-SIP-600 JAE14090958
2 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL1413DX2B
3 16 CEF720 16 port 10GE WS-X6716-10GE SAL1414EL2Q
4 1 Application Control Engine Module ACE20-MOD-K9 SAD1408036Z
5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1414ERDT
6 5 Supervisor Engine 720 10GE (RPR-Warm) VS-S720-10G SAL1414ERE3
7 16 CEF720 16 port 10GE WS-X6716-10GE SAL1414ER93
8 16 SFM-capable 16 port 1000mb GBIC WS-X6516A-GBIC SAL1326SVBS(code)
View 7 Replies
View Related
Jun 16, 2011
I try to access to WS-SVC-NAM-2 module in the Switch 6509. But is not work although the HTTP port is enabled (I tested with the command telnet @ip 80).
I try telnet access to the module to check the config , but I always the message that the lo gin / password is wrong even though they are valid.
View 4 Replies
View Related
Feb 29, 2012
Need to remove the IPSec VPN SPA module from the 6509 chassis. Does the module is hot swappable or does the 6509 need to be turned off prior to removal.
View 2 Replies
View Related
May 16, 2011
We have a 6509 with an ACE module. For reasons I don't fully understand the ACE is running using a BVI in bridge mode. It has loads of secondary interfaces.
[Code]...
I can ping all of the IPs on the BVI, but only servers in Subnet 10.7.42/42 can ping out of the the layer 3 on the 6509. I have all the routes configured properly on the 6509 pointing to the ACE for these subnets. The question is though the config has been excepted, is there a limit to the number of secondary on a BVI.
View 1 Replies
View Related
Apr 27, 2010
I have a cisco 6509 configured with a cisco NAM module. I have reset the config of the NAM module by the config clear command. Since this moment I can't no more ping the NAM module via the management port: OK via the 127.0.0.91 address and log in ok via the ios cli session command. [code] I have already tried to reboot the module via the ios cli hw module command and nothing better.
View 12 Replies
View Related
May 8, 2013
I am desiging a topology with two Cat 6509 and Two ACE Module, one ACE per Catalyst. I am thinking to use bridge mode for the customer contexts, I would like to know if the Bridged mode is an Assymetric topology.
The server gateway is the ip address of the ACE or the Router?
View 6 Replies
View Related
Jan 25, 2011
I had to reset a 6509 MSFC2, using reset command on the switch. However when the msfc2 reloaded it had a different configuration than the starup-config. I have a daily backup of start-up config and it was very different from that. I had to make many changes to bring it back to normal. What now I dont get is from where did the msfc2 got this config file? and how can I avoid this from happening again... I want it to load start-up config when it loads. [code]
View 2 Replies
View Related
Dec 27, 2012
I have a stack of 2 x 3750X switches these are running 12.2(55)SE5. I needed to add some static IP routes and found that the ‘ip routing’ command is not supported. I came across a document that stated “On switches running the LAN base feature, static routing on VLANs is supported only with Cisco IOS Release 12.2(58)SE and later.” So I have upgraded to 12.2(58)SE2, but ‘ip routing’ is still not a valid command.
The release notes state:“On the Cisco Catalyst 3560-X and 3750-X Series, it adds support for 16 static IPv4 routes in the LAN Base image.”
I have read other posts that talk about running the ‘sdm prefer routing’ command which I have done, but I am still unable to add any routes or run the ‘ip routing’ command.
View 4 Replies
View Related