Cisco Switching/Routing :: 6513 - Redundant Supervisor Engine 720-3B Reloads
Sep 1, 2010
There is a Cisco Catalyst 6513 in my office. Recently we decided to setup redundant Supervisor Engine 720-3B. When we did it, its became STANDBY COLD, and then it reloads. IOS is equal on both supervisors. It must be STANDBY HOT (SSO) redundancy. There is a configuration and show ver and show module outputs, and log of my actions.
View 3 Replies
ADVERTISEMENT
Jun 25, 2012
Is it possible to run VSS on 6513 and 6509 when considering both has same supervisor engine 2T and same IOS image.
View 1 Replies
View Related
Apr 19, 2013
In my 6513 switch chassis we have two Supervisor Engines 720 one is marked Active other as Hot. what is the diffrence in their mode as by name I suppose that Active one is currently in use and Hot one is in standby mode.They are showing in this manner.
Module Ports Card Type
7 2 Supervisor Engine 720 (Active)
8 2 Supervisor Engine 720 (Hot)
View 4 Replies
View Related
Oct 26, 2011
We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?
View 4 Replies
View Related
Aug 23, 2012
The SuperVisor engine in slot 1 of a Catalyst 6513 needed to be replaced because a hardware defect. The SuperVisor engine in slot 2 is active and running CatOS 8.5. The new SuperVisor engine for slot 1 came with CatOS 6.3 and was not syncronized auromatically after insertion. When the customer enter the command "Show boot" he get the output:
AG-A6513-51> (enable) sh boot
BOOT variable = bootflash:cat6000-sup2k8.8-5-5.bin,1;bootflash:cat6000-sup2k8.7-6-2.bin,1;
[Code].....
View 1 Replies
View Related
Apr 18, 2013
i have a standalone SUP720, no traffic is passing through it. only one port connected for remote telnet, its kind of backup device.today i checked its log, and there are some wiered message.is it a software bug or my SUP has gone bad? [code]
View 24 Replies
View Related
May 6, 2013
We have a scenario with 2 chassis, both with 2 supervisor Engine 2T, we try to make a configuration of VSS with the chassis and would link to know if is possible have 2 supervisor on chassis one and 2 supervisors on chassis 2 with VSS?
Router#sho switch virtual redundancy
My Switch Id = 1
Peer Switch Id = 2
Last switchover reason = active unit removed
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso
[code]....
would like to use the second supervisors for obteind the local redundancy en chassis 1 and 2, this is possible?
the actually version on four supervisors is: s2t54-ipservicesk9-mz.SPA.150-1.SY3.bin
View 6 Replies
View Related
Oct 1, 2012
I have configured the VSS in two cisco 6509-E series with only one supervisor engine, but if i configured with two supervisor engine. it is going to common mode. One supervisor engine is 3c and 3cxl.
View 2 Replies
View Related
Nov 3, 2011
I have an older 4006 with a Supervisor II+. We now need OSPF support, which the Sup II+ does not provide. I have access to a Supervisor III (WS-X4014), which will provide OSPF support. Question is, are there any gotchas to shutting down the switch, replacing Supervisor Engines and then powering up? What about the flash card? On my current system, it appears that I am only using bootflash: , which is where the IOS resides (see below). Since my startup config is in nvram and my IOS is in bootflash, what's the purpose of the flash card in slot0: ? and where does NVRAM and bootflash actually live on a 4006 ( on the Supervisor Engine?)
sh bootvar
BOOT variable = bootflash:cat4500-ipbase-mz.122-31.SGA11.bin,1;,1;
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist
[Code].....
View 5 Replies
View Related
Nov 28, 2011
we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]
View 1 Replies
View Related
Oct 24, 2012
I buy a Cisco 4003 Switch with Supervisor Engine I but it only run CatOs and i whant it to run Cisco IOS so whitch Supervisor Engine can the Cisco 4003 Switch run? i have look at the Supervisor Engine III it can run Cisco IOS and Layer 3 but can i use that in my Cisco 4003 switch?
View 14 Replies
View Related
Apr 5, 2013
For C6500 chassis, sup-fould like to know the dirrerence between supervisor engiene 720 sup-bootflash and sup-bootdisk?
View 3 Replies
View Related
Mar 16, 2012
On an existing 4500 switch with a single sup 6-E, another sup 6-E is added. But the second sup6-E comes up as synchronised with active and in a few minutes time, reloads again. the software is 12.2(44) is the same on both sup engines. the redundancy sso output shows that slot6 is disabled.
View 1 Replies
View Related
Feb 10, 2012
I would like to add a redundant supervisor to my core 6509. Is this tricky to do? I know they have to be running the same IOS. I am worried if I put the new supervisor in it will write over the exsisting running config.
Catalyst 6000 supervisor 2 (Active) WS-X6K-S2U-MSFC2
Policy Feature Card 2 WS-F6K-PFC2
Cat6k MSFC 2 daughterboard WS-F6K-MSFC2
View 4 Replies
View Related
Feb 5, 2013
we have 2 Supervisor IV modules in our 4507, i want to upgrade the IOS as its still on 12.2 and i am going to upgrade it to the latest.
my first question is, if i update the IOS on the bootflash will it replicate to the secondarybootflash?
secondly, can i force a reboot of the secondary supervisor, then the primary after the secondary is up? i'm just trying to minimise downtime and get a plan going.
is there a difference in 12 vs 15 that would impact my current config that i should be aware of?
View 2 Replies
View Related
Nov 7, 2011
I have an 4507R with one Supervisor Engin V card. I want to add a redundant supervisor engin card to my 4507R Chassis.
Can i use supervisor engin 6-E for redundant or i must use Supervisor Engin V ?
Witch model of Supervisor Engines Supported with this chasis?
View 2 Replies
View Related
Jun 19, 2012
Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?
View 1 Replies
View Related
Dec 26, 2012
When i have configured the 4507R switch but the configure is not sync with the standby module..... I have doing some troubleshooting
1. type the command "show redundancy" no standby module is showing
2. type the command " redundancy force-switchover" showing the message " no standby module is present"
3. type the command "hw-module module 2 reset" then the standby module is reset and status light is blinking like it is booting..
View 6 Replies
View Related
Dec 5, 2011
I have a 4507R with a WS-X4515 supervisor V. It was booting into rommon mode, so I attempted to boot to an IOS image from TFTP. The boot process hangs at at the end of the below output and the then the status light blinks orange. I left it sit like this overnight, and it remained the same.
rommon 23 >boot tftp://x.x.x.x/cat4500-entservicesk9-mz.122-53.SG2.bin
Tftp Session details are ....
Filename : /cat4500-entservicesk9-mz.122-53.SG2.bin
[Code]......
View 9 Replies
View Related
Feb 14, 2012
How to configure Supervisor Engine Redundancy between two different cisco 4507R and 4506E.
View 5 Replies
View Related
Oct 30, 2011
I have a Cisco 6500 series switch with VS-C6509E-S720-10G ,I have two redundant supervisors between two chassis on the LAN with no add-on line cards ?
I need to know if I can use the redundant supervisor 10 Gb uplinks to form a layer-2 Port channel between the two 6500 switches as i do not want to use want to keep the port idle additionally I need more bandwidth between the two switches for my server farm?
View 1 Replies
View Related
May 15, 2012
we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario
1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the faulty VS-S720-10G from the slot 5
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?
View 3 Replies
View Related
Oct 19, 2012
We are expanding out LAN network with more 2960 access switches. All the access switches are suppose to be connected to core switch (4507R) but i have less port on the core switch.
On the core switch we have two supervisor engines (WS-X4515 ---description : "Supervisor IV with 2 1000BaseX GBIC ports"). I can see that on each supervisor engine i have two 1 GB SFP ports available and if i calculate for two supervioser engine i will have 4 1GB ports.
But at particular time only one supervisor engine is active and other is in standby mode (redundancy mode used is SSO between two SUP engines).
Can i used all 4 SFP ports for connecting 4 uplinks to the 4 access switch?Will all the 4 SFP ports active at one time or only 2 SFP ports will be active that is for only active supervisor engine.
View 10 Replies
View Related
Dec 15, 2011
I know in the past on earlier models of the supervisors that you couldn't use all eight uplink ports(4 on each supervisor) simultaneously when you have two supervisors on the chassis. Is this the same case for the 10Gb uplinks on the supervisor 7-E on the 4500 chassis? I tried doing my research but couldn't find an answer.
View 3 Replies
View Related
Jun 18, 2012
I have a supervisor blade, (VS-S720-10G-3C), in a 6513 that is faulty and needs replaced. Do I need to replace the IOS on the new supervisor blade to make sure it is the same as the IOS image that is on the Active supervisor module, or will it synchronize automatically?
In the synchronization process, the active supervisor engine checks the standby supervisor engine run-time image to make sure that it matches its own run-time image. The active supervisor engine checks three conditions:
#
•If it needs to copy its boot image to the standby supervisor engine
#
•If the standby supervisor engine bootstring needs to be changed
#
•If the standby supervisor engine needs to be reset
I was reading the above documentation that mentioned the active supervisor should copy the image if it detects a newly installed standby supervisor blade with a different image, is this correct or was it referring to synchronizing the configuration file?
View 3 Replies
View Related
Mar 6, 2012
I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.
View 1 Replies
View Related
Aug 8, 2012
We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?
View 2 Replies
View Related
Oct 29, 2012
we have a chassis 6513-E and a module WS-X6748-GE-TX, I'd like to know if could I put this module in any slot, since the documentation from Cisco says that any slot from a chassis 6500-E Series can support this module. And then in the documentation of WS-X6748-GE-TX says that this module is not compatible in the slots 1-8 of the 6513 chassis, only from 9th to 13th slots, in those slots from the 6513-E we already have 4x WS-X6748-GE-TX, and we'd like to know if could we put the module in the rest of the slots. The 6513, and 6513-E is kind of confusing.
View 4 Replies
View Related
Aug 30, 2012
Just checking if any switch reset after one PS failure (configured in default redundant mode). No crash file has been generated. Switch is running IOS 12.2(44)SG and PWR-C45-1400AC. After the switch went online we found that PS1 has gone bad. Haven't found any bug in the tool kit. [code]
View 5 Replies
View Related
Dec 23, 2011
I was looking to 6500 series switches. I saw DFC4 module (WS-F6K-DFC4-A, WS-F6K-DFC4-AXL) and (WS-F6K-DFC4-E, WS-F6K-DFC4-EXL). Data sheet for supervisor engine 2T wrote that for maximum performance you should DFC4. I'm a bit confused. I didn't any useful information about it:
1. DFC4 is a separate module(consumes 1 slot)? Does it have any ports on it?
2. Is it a daughter card? If yes, should it be installed on supervisor or it should be installed on line cards?
View 7 Replies
View Related
Dec 26, 2010
Removing and Installing a Supervisor Engine on a cisco router 7690 and more important IOS upgrade of this module.
I need some kind of manual, but I would prefer a short procedure to do this change. A brief of the steps to do that. Also i don't if i have to upgrade the new module after install it.
PD.
IP7VAL02#sh modMod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ ----------- 1 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL1034Z32J 2 48 CEF720 48 port 10/100
[Code]....
View 1 Replies
View Related
Aug 12, 2012
I have a strange issue with 4500 E chassis loaded with SUP 7L-E which always remains in ORANGE LED status, also the uplink ports interface is down and the line protocol is down but when i execute the command sh int gig1/5 it show me the media type sfp but there is no red laser light seen in the sfp transiever,The below command is configured for the uplink gig port on the SUP engine.hw-module uplink select gigabitethernet?
View 10 Replies
View Related
Jun 8, 2012
a 6509 and a 4506 with 2, 1gb interfaces in a portchannel. Bring it up and everything is fine. Save the config and reload either switch and the interfaces stay in Not Connected state. Either doing a No Shut or a physical unplug the SFP and plug it back in will bring it up with no issues. Interfaces do not go into Err Disabled state they stay in Not Connected like there is no fiber plugged into it. No error mesages in the log. The Just the Interface is now up.Both are running very new code,
6509 - s2t54-ipservicesk9-mz.SPA.150-1.SY1.bin ( 15.0.(1)SY1 )
4506 - Version 03.02.00.XO
View 1 Replies
View Related