Cisco Switching/Routing :: Catalyst 6500 / QoS For Supervisor 2T?
Apr 30, 2013
I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
[URL]
But I don't see anything for the new Supervisor 2T?
View 3 Replies
ADVERTISEMENT
Sep 21, 2012
1. We now have SupA & SupB in the chassis, due to some mistake we have same IOS version but different feature set on them, although we configured redundancy mode sso, in the "show redundancy" we see Operating Redundancy Mode = rpr due to Software mismat, we now need to fix them as same feature set image, if I use "copy sup-bootdisk0:/xxxx slavesup-bootdisk0:/xxx", then write memory, does this cause any service/network interuption?
Available system uptime = 1 year, 1 week, 4 days, 9 hours, 21 minutes
Switchovers system experienced = 2
Standby failures = 0
Last switchover reason = active unit removed
[code]....
2. We did a failover test with this status, found that if we triggered supervisor failover, all modules will reload thus the services if interupped. How about after we make the Operating Redundancy Mode as sso, will this behaviour shows again? Or a stateful failover will happens, then modules no need reload?
3. We are using OSPF as our L3 routing protocol, after reference to the configuration, nsf should be enabled, we want to ask in the OSPF-domain nsf should be configured in all OSPF-enabled router or only 6500 which have dual-sup?
4. We also found that the interfaces(3 * Gig & 2 * TenG) in Standby supervisor cannot be use even enabled & configured, is it because we are running rpr mode now or will be the same even change to sso? Before customer have some older supervisor in 6500 non-e chassis, and they can use the standby supervisor interfaces as traffic forwarding, they use rpr-plus mode before, how about in sso mode?
View 6 Replies
View Related
Feb 12, 2013
Q. Does the Supervisor 720 support all existing Cisco Catalyst 6500 series interface and services module, protecting customer investments?
View 1 Replies
View Related
Oct 11, 2011
I want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)
View 1 Replies
View Related
Aug 10, 2012
Is there functionality difference in Supervisor Engine 2 and Supervisor Engine 2T for Catalyst 6500 ?
View 3 Replies
View Related
Feb 3, 2010
We've been mocking up a test lab to test VSS on two 6500's. Each 6500 has one sup720 and a 6708-10ge blade and we've established the two 10ge links between the two chassis; the first from the each chassis' sup and the second from each 6708.My question is, what happens when the supervisor fails on one of the chassis?
View 10 Replies
View Related
Apr 15, 2012
I am trying to understand the implicit limit to the priority queue. I know you can define an explicit policer but if you don't I can't find out what the rate limit really is.
View 5 Replies
View Related
Sep 22, 2011
I'm working on deploying a new 4510R+E for our organization. This is my first experience with a modular switch. I'm trying to enable SSO, however in the redundancy configuration mode, the sso command is not available. Is SSO only available with certain software images / licensing levels? [code]
View 2 Replies
View Related
Feb 10, 2013
I have a Sup32 that I suspect has faulty NVRAM (e.g., I am unable to "wr mem" on the device - it states resource is busy but no other active connections exist). Prior to replacing the supervisor engine I'd like to take a crack at formatting NVRAM to see if it resolves the issue. This supervisor does not have a CF card installed, thus no Disk0:. Within the CLI, I am presented two options with the "format" command - bootflash: and sup-bootflash:. Bootflash: does not have any data on it, however, sup-bootflash: contains my IOS image. I believe that both of these locations are simply directories within NVRAM.
View 3 Replies
View Related
Nov 28, 2011
we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]
View 1 Replies
View Related
Oct 30, 2011
I have a Cisco 6500 series switch with VS-C6509E-S720-10G ,I have two redundant supervisors between two chassis on the LAN with no add-on line cards ?
I need to know if I can use the redundant supervisor 10 Gb uplinks to form a layer-2 Port channel between the two 6500 switches as i do not want to use want to keep the port idle additionally I need more bandwidth between the two switches for my server farm?
View 1 Replies
View Related
Apr 22, 2012
I have a question. I have a 6500 with two supervosrs and they both have CATOS. One of them failed and I need to replace. As long as the hardware is the same does the CATOS have to be indentical or can this be different.
View 4 Replies
View Related
Jan 8, 2012
Does a new Cisco Catalyst 4500 series supervisor 7L-E model WS-X45-SUP7L-E is backward compatible with a Cisco Catalyst 4500 series chassis model 4507R? I've checked on Cisco website for that Supervisor and it shows only new chassis models WS-C4507R+E and R-E, but what about old type of chassis? We need to upgrade that Supervisor as it's out of line, but we don't really want to buy a new chassis as well as it's going to be very pricy.
View 6 Replies
View Related
Jun 9, 2013
I'm trying to configure a egress netflow in a 6500 (VSS) with VS-S720-10G supervisor. I foud some old posts and understood that netflow wasn't supported on 6500 but i found a new document and it seems that netflow is supported in Supervisor Engine 2T:[URL] Does the netflow still not supported in VS-S720-10G? It's weird because the command is supported:
#sh run int vlan 4
Building configuration...
Current configuration : 353 bytes
!
interface Vlan4
ip address X.X.X.X 255.255.0.0
[cod]....
View 1 Replies
View Related
May 15, 2012
we have Supervisor Engine 720 10GE (VS-S720-10G) in slot 5 on Catalyst 6509-E. Slot 6 is free. We need to replace VS-S720-10G. Is it possible the following scenario
1. we will insert new VS-S720-10G into the slot 6
2. then we will remove the faulty VS-S720-10G from the slot 5
Will everything work without interuptions. Is any document where I can find step-by-step procedure how to replace VS-S720-10G ?
View 3 Replies
View Related
Jun 4, 2012
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
View 1 Replies
View Related
Nov 30, 2009
I have two Catalyst 6506 in VSS mode with VS-S720-10G running 12.2(33)SXI1 IP SERVICES.I have two firewalls that communicate on to the other through a dedicated VLAN created on Catalyst 6506.
One firewall is able to ping the other one on this dedicated VLAN but if I send multicast traffic from firewall-1 I didn't receive it on firewall-2.I found a bug related to multicast issues on Cisco WS-C6509-E with VS-S720-10G. The bug ID is CSCtc59038.
View 9 Replies
View Related
Nov 28, 2012
My Company use Core Sw 4507R-Sup 7L-E with Enterprise Services License. I has upgraded to use iOS cat4500e-universal.SPA.03.03.01.SG.151-1.SG1.bin
When I use match protocol in class-map, there are only about 10 protocols, and not have those ones I need. I intend to expand the list of protocols to do some Policy-map by loading PDLM. But 4507 is no longer support NBAR. So do we have another way to set Catalyst 4507R with Sup 7L-E recongnize more protocols in match protocol command?
View 1 Replies
View Related
Aug 23, 2012
The SuperVisor engine in slot 1 of a Catalyst 6513 needed to be replaced because a hardware defect. The SuperVisor engine in slot 2 is active and running CatOS 8.5. The new SuperVisor engine for slot 1 came with CatOS 6.3 and was not syncronized auromatically after insertion. When the customer enter the command "Show boot" he get the output:
AG-A6513-51> (enable) sh boot
BOOT variable = bootflash:cat6000-sup2k8.8-5-5.bin,1;bootflash:cat6000-sup2k8.7-6-2.bin,1;
[Code].....
View 1 Replies
View Related
Oct 26, 2011
We bought Cisco sup engine WS-SUP32-GE-3B for 6500 switches 2 nos for redundancy. I have connected 6 systems on each sup engine ports. How to clarify whether both sup engine will forward the data while one is Master and other is standby?
View 4 Replies
View Related
Aug 8, 2012
We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?
View 2 Replies
View Related
Apr 26, 2012
Any step-by-step configuration guide of how to enable DAI on Cisco Catalyst 6500 Series Switches.
View 1 Replies
View Related
Mar 19, 2013
document which explians normal booting sequence in a 6500 Switch running IOS. What I am looking for is in which order the image is loaded in SUP, RP, SP etc
View 1 Replies
View Related
Dec 20, 2011
I got problem with wake on LAN software.. The software unable to ON all pc's remotely if sitting under different vlan. Everything is ok if using the same vlan. Below are the network diagram & switch configuration.
Layer 3 switch Intervlan routing configuration
ip forward-protocol udp 7
!
interface Vlan4
description vlan Client-WOL
ip address 172.22.51.253 255.255.254.0
ip access-group Deny_HTTP_Vlan1 in
ip helper-address 172.20.1.246
[code].....
After configured all the switches with the above setting, the software still cannot wake all the pc's using LAN. Base on sniffing, i can't find UDP port usage by the software. Attached here with print screen from wireshark.
View 7 Replies
View Related
May 5, 2013
"How to display the EOBC error counters in the Catalyst 6500 series switches and a definition of the EOBC interface" document here on support forum stays that The Ethernet Out of Band Channel (EOBC) is a half duplex channel that services many functions, which include the Simple Network Management Protocol (SNMP) and the packets that are destined for the switch.
Previously i were thinking that EoBC used only for SCP and SLP protocol. In addition i found other article (but not on cisco site, heh) where stays that The Results bus is a control plane, while the C (EoBC) bus is more of an "admin plane", thus you will never see data packets (such as CDP, SNMP, etc.) going over the R or C bus.
So there is a big contradiction between those two statements. How to prove one of those and if first one right, what meaned under the packets that are destined for the switch in it? SCP and SLP or other traffic as well?
View 3 Replies
View Related
Apr 22, 2013
I am migrating services from SUP720-3B to VS-SUP2T-10G= and moving to a VSS configuration between a pair of Cat6506 distribution layer switches. I need to enable QoS on these switches, primarily to trust dscp and also to prioritise voice traffic. The autoqos feature works for some ports but does not work on port-channel interfaces and port-channel member interfaces. How can I apply the qos settings for these interfaces in line with what auto qos would normally provide. My line cards are as follows:
Civic_6506VSS#sho mod
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE
[Code].....
View 1 Replies
View Related
Jan 23, 2011
The diagram below is the configuration we are looking to deploy, that way because we do not have VSS on the 6500 switches so we can not create only one Etherchannel to the 6500s.Our blades inserted on the UCS chassis have INTEL dual port cards, so they do not support full failover.
Questions I have are.
- Is this my best deployment choice?
- vPC highly depend on the management interface on the Nexus 5000 for the keep alive peer monitoring, so what is going to happen if the vPC brakes due to:
- one of the 6500 goes down
- STP?
- What is going to happend with the Etherchannels on the remaining 6500?
- the Management interface goes down for any other reason
- which one is going to be the primary NEXUS?
Below is the list of devices involved and the configuration for the Nexus 5000 and 65000.
Devices
· 2 Cisco Catalyst with two WS-SUP720-3B each (no VSS)
· 2 Cisco Nexus 5010
· 2 Cisco UCS 6120xp
· 2 UCS Chassis
- 4 Cisco B200-M1 blades (2 each chassis)
- Dual 10Gb Intel card (1 per blade)
vPC Configuration on Nexus 5000
TACSWN01
TACSWN02
feature vpc
vpc domain 5
reload restore
reload restore delay 300
[code]...
View 22 Replies
View Related
Dec 10, 2012
Catalyst 4500 or 6500 VSS Capabilities?
View 6 Replies
View Related
Dec 15, 2011
Its possible FTTx on a 6500 ?
View 2 Replies
View Related
Jul 16, 2012
one of the most widely deployed switches in the world. The "Swiss Army knife of network", can do routing, switching, security, wireless and almost everything that you would want your core switch to do. Remember to use the rating system to let Akshay know if you have received an adequate response.
Akshay might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Network Infrastructure sub-community LAN, Switching and Routing discussion forum shortly after the event. This event lasts through July 27, 2012. Visit this forum often to view responses to your questions and the questions of other community members.
View 22 Replies
View Related
Nov 15, 2011
how to identify which modules are supported by cisco catalyst 6500. is there any OID which can give us the information
View 2 Replies
View Related
Jun 29, 2012
I want to know what is this process used for on a catalyst 6500 ? we have got following message in the crash file, probably due to CSCsv77354
Jun 30 16:06:47.099 UAE: %SYS-6-STACKLOW: Stack for process ACE HAPI running low, 0/6000
View 3 Replies
View Related
Mar 24, 2013
cisco WS-C6509-E Core switch with IOS "s72033-ipservicesk9_wan-mz.122-18.SXF11"
i have 2 question
Q.1 i want to upgrade this switch what is the latest IOS ver. supported by this module ?
Q.2 i need to enable http server on this switch when i run this comman it's accsebt but i cant get http work
View 1 Replies
View Related