Cisco Switching/Routing :: Cat 6500 - Possibility Of LLQ On Ethernet Modules
Sep 17, 2012
Is it possible to implement LLQ(QoS) on ethernet modules in the Cat 6500? For this feature, I can only find documentation about ES+ modules or SPA/SIP modules! (according to the feature navigator LLQ is supporten on the concerning HW and SW image)
View 2 Replies
ADVERTISEMENT
Mar 11, 2013
is there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies
View Related
Nov 15, 2011
how to identify which modules are supported by cisco catalyst 6500. is there any OID which can give us the information
View 2 Replies
View Related
Apr 22, 2012
I have a question. I have a 6500 with two supervosrs and they both have CATOS. One of them failed and I need to replace. As long as the hardware is the same does the CATOS have to be indentical or can this be different.
View 4 Replies
View Related
Dec 12, 2012
While configuring PoE Ethernet EHWIC PoE modules with ISR G2 routers Cisco DCT gives a warning to select AC Power Supply with PoE ‘PWR-3900-POE’. Do we need to select the PoE power supply for Enhanced EtherSwitch SM PoE modules also (at present it does nt show any warnings)?
View 1 Replies
View Related
Feb 20, 2012
I curently have 2 Data centers connected with a Metro Ethernet Connection. Each Data Center has 6500 with Sup720s. The Metro Ethernet connection is currently conected by a L3 routed interface. I now need to enable VRFs between the locations and want to determine the best way to adjust the Mero. I was considering adjusting the routed interface to use Ethernet sub-interfaces. Each VRF would be given a different subinterface over the Metro Ethernet connection. I have done this on internal LAN connections but am concerned about exteding across data centers over Metro E.
View 1 Replies
View Related
Jan 7, 2013
I'm looking at the possibility of purchasing a few 3750 to build a switch stack to replace my current core and access switches. I'd like for the stack to support server, SAN, and user traffic, as well as provide simple switch management, redundancy, and failover. I've also been looking at the 4500, 6500, and Nexus series switches (although the Nexus switches maybe a bit too much for my network).
My current environment consists of 3560's as the core/distribution/access switches, a mixture of Hyper-V and VMWare environments (although we're slowly migrating to Hyper-V), an HP SAN (P4500), and about 100 users. Any issues going with the 3750's or have an alternative, more efficient solution?
View 8 Replies
View Related
Nov 20, 2012
Normally when we do HSRP with vPC on N7K the device will be Active/Standby in control plane but it will be Active/Active in data plane. In this case any traffic reach to standby device it can forward traffic directly to uplink which is not my desire. My goal is all traffic should pass through active (control plane) device in every case unless active device totally dead. So Is it possible for Nexus 7000 to be HSRP Active/Standby in Data Plane ?
View 4 Replies
View Related
Feb 7, 2013
I have a WS-C4510R+E with
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 48 10/100/1000BaseT Premium POE E Series WS-X4748-RJ45V+E CAT1612L1JD
2 48 10/100/1000BaseT Premium POE E Series WS-X4748-RJ45V+E CAT1612L1JW
3 12 10GE SFP+ WS-X4712-SFP+E CAT1622L0SC
4 12 10GE SFP+ WS-X4712-SFP+E CAT1622L0RM
5 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7-E CAT1620L1UJ
6 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7-E CAT1620L1Z2
Can i add two WS-X4712-SFP+E and two 10 GE ethernet module also?
Is there 10GE ethernet module with WS-C4510R+E.
View 2 Replies
View Related
Dec 14, 2011
Here i have a customer who has 7609 router with modules
ws-+6748-ge-tx
ws-svc-wism-1-k9
ws-sup720-3b
ws-sup720-3b
ws-svc-wism-1-k9
ws-6724-sfp
ws-x6704=10ge
ws-x6724-sfp
will this modules will be supported to the new chaisis ios or in the chaisis 7609S
View 1 Replies
View Related
Dec 21, 2011
how can we upgrade 6500 non modular ios to normal 6500 ios?
View 5 Replies
View Related
Nov 23, 2012
we have a old Nexus 5010 running version 5.0(3)N1(1)it is in a franckenblock(like frankenstein) ie . we bought the parts and create our own system design before VCE was created. He have since bought VCE V block for our production sites. we use the franc ken block to test before we migrate to the production v block 300 FIX the issue we have is the 5010 will only see two 1 Gb/s SFP fiber modules in the first 12 slots. All these slots are dual 1g/10G. If we add more than two, it claims not to see them. We tried swapping the sfp and using both sfg-GE-MM and GLC-SX-MM moduels, no difference at all 1g sfp are in the first 5 slots. only the first two slots are up.the others say "Link not connected" or "SFP not inserted"all five links are the same SFP and are plugged in other switches.the green link lights are on plugged in SFP, even when the CLI states they are not plugged uni tried both two types of 1 Gb/s SFP. sfg-GE-MM and GLC-SX-MM ,i move the sfp between slot 1,2 and 3,4,5. nothing changed,From "sh int brief" you can see that it can see the sfp ie they are all 1Gfrom "sh int status " it sees 1g but why does it say type 10G?why when i go to the "int e 1/5" and try switch port mode now, it can't mode and trunk at now there (;also how to i stop or clear EU51 %SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is unexpectedly high at 87%.i put as much info in the attached file as i could.
View 1 Replies
View Related
Mar 4, 2013
I am having issues trying to combine two modules into one VDC. The modules are as mentioned below: When I try to combine module 1 & 10 as shown above, the nexus 7000 switch displays 'Not compatible'. I've read the online guide and it mentions that the F2 and M1 module cannot be combine into the same VDC. Problem is, my customer has already purchased the module, how do i solve this problem? If I separate the VDC, how does module 1 talk to module 10 if user wants to send traffic to Internet or Server Farm?
View 3 Replies
View Related
Apr 29, 2013
I am working on a project to connect 2 switch stacks via 10 Gb fiber. I am told that the 3750Xs do not natively receive the 10 GB SFPs. What part numbers do i need to order to make this work? Is there any IOS image requirements?
View 14 Replies
View Related
Jun 3, 2013
I have already understood the following notice for using VSS function with 6700 series modules.For example there is the compatibility HW revision issue between the 6700 line card and CFC or DFC and so on. [code]
View 1 Replies
View Related
Dec 22, 2011
I want to purchase CISCO2901-SEC/K9 let me know all its specification and how many Ethernet ports supported by its modules?
View 1 Replies
View Related
Sep 5, 2012
our network is spread over 15 floors and each floor we have 5-6 switches. we are planning to purchase cat3750-x 24 ps poe with C3KX-NM-10G network modules. Each floor has two up links to the core switch with single mode fiber and other being the multimode.Suppose if we are purchasing 75 switches do we have to purchase 75 C3KX-NM-10 G modules.? or can we limit our purchase with 15 C3KX-NM-10G sothat two uplinks from each floor can be made? since network modules are optional cost factor is invovled. Or any issue with stacking ? the SFPs will be LR and LRM MODULES.looking for an answer ? whether the new usb type console cable comes bundled with cat350x or shall we have to order separately?
View 7 Replies
View Related
Jan 23, 2011
We currently have two 6509's running in VSS, both switches have a WS-6748-GE module in slot 3. I'm in the processing of removing these modules. I will then be replacing them with a different module type, but I need to know how to remove the old configuration of the previous modules.
View 4 Replies
View Related
Feb 5, 2012
How to configure my serial modules on my 2600 and 3640? Each router has the WIC-2T with two cables connecting them. I tried to ping one router from the other, but no luck. Serial IP address I just made up, this is my home lab, so if I messed those up some how,
Here is the running config for each rotuer:
2610:
Current configuration : 1071 bytes
!
version 12.3
[Code]...
View 22 Replies
View Related
Oct 8, 2012
I've installed second WS-X6748-SFP linecard on my catalyst 6509 with sup720-3b and after that NAM-2 and IDSM-2 module become inaccessible from management network. I can only login with session slot N proc 1.When I execute #hw-module module 4 reset, modules become accessible.
#sh module from cat6509
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
2 48 CEF720 48 port 1000mb SFP WS-X6748-SFP SAL114670XW
3 48 48-port 100FX SFP Ethernet Module WS-X6148-FE-SFP SAL1201BZKF
4 48 CEF720 48 port 1000mb SFP WS-X6748-SFP SAL1625ETFJ
5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1206FNGQ
6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAL1206FVFB
8 8 Intrusion Detection System WS-SVC-IDSM-2 SAD120502LR
9 8 Network Analysis Module WS-SVC-NAM-2 SAD120206LB
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
2 001e.4a3e.3b30 to 001e.4a3e.3b5f 1.10 12.2(14r)S5 12.2(18)SXF1 Ok
3 001e.4aea.e7b0 to 001e.4aea.e7df 3.3 8.4(1) 8.5(0.46)RFW Ok
4 5057.a895.bb84 to 5057.a895.bbb3 2.4 12.2(18r)S1 12.2(18)SXF1 Ok
5 001c.58d0.6dc4 to 001c.58d0.6dc7 5.6 8.5(2) 12.2(18)SXF1 Ok
6 0016.c848.3698 to 0016.c848.369b 5.6 8.5(2) 12.2(18)SXF1 Ok
8 001e.f7a1.54b0 to 001e.f7a1.54b7 6.3 7.2(1) 7.0(8)E4 Ok
9 001e.f72a.ba62 to 001e.f72a.ba69 4.3 7.2(1) 5.1(2) Ok
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
2 Centralized Forwarding Card WS-F6700-CFC SAL114881B6 4.0 Ok
4 Centralized Forwarding Card WS-F6700-CFC SAL1624EGQS 4.1 Ok
5 Policy Feature Card 3 WS-F6K-PFC3B SAL1206FNZY 2.3 Ok
5 MSFC3 Daughterboard WS-SUP720 SAL1206FSFH 3.1 Ok
6 Policy Feature Card 3 WS-F6K-PFC3B SAL1206FP27 2.3 Ok
6 MSFC3 Daughterboard WS-SUP720 SAL1206FN26 3.1 Ok
8 IDS 2 accelerator board WS-SVC-IDSUPG ADBG7270048 2.5 Ok
cat6500 running 12.2(18)SXF12a ios...
View 8 Replies
View Related
Jun 13, 2012
We have many 3750E's and need to use Finisar X2 modules FTLX8541E2. After 15.0(1) IOS upgrade the 3750's now recognize the Cisco part X2-10GB-LRM's, but will not recognize our Finisar modules.
View 1 Replies
View Related
Apr 4, 2012
I have a Cisco 857 router which i used for Internet connection with RJ11 connectior (ADSL0 POTS) but now the ISP has changed the internet link with PPOE type and the ONT connection is RJ45 , Is there a possibility to configure one os the Fast Ethernet ports as WAN port for internet.
View 2 Replies
View Related
Oct 14, 2012
I recently ran an upgrade on my 6509-E's and when the first switch came back up, 3 of the 10/100 switches that were in the chassis did not power on. After further investigation, these models are not supported by this latest IOS version. The module # is : WS-X6248-RJ-45
We have one WS-X6348-RJ-45 and since it was a few weeks ago I did this I can't remember for sure but I believe this one came up.
Where can I found the information regarding this being unsupported but I know it is out there and any page that showed me that this was unsupported with the latest stable IOS of 12.(33).
In addition to this question, I have approval to purchase some newer gigabit switches that will be supported by this new IOS version and hopefully at least the next few over the next few years. Which specific gig models are currently and hopefully should be supported for the next few years? I don't need PoE or anything spectacular, just regular switches that are attached to either servers or virtual hosts. I've been looking at the lists of what is out there and it seems like there are hundreds of different models and it is becoming difficult to determine what is what.
View 1 Replies
View Related
Mar 20, 2012
How to get fiber optic modules for Cisco 2821 series router. I can not find anything apart a SFP module which contains only one SFP port.
View 9 Replies
View Related
Apr 19, 2013
I have two 2960-s switches with GLC-FE-100FX fibre modules in and I am seeing packet loss over the link that is connected to the modules. When the interface is shutdown and brought back up it always comes up in half duplex even thought it is set to full in the config. I've seen other posts where you have to use the command no duplex then full duplex to get it to come up int full duplex. This does appear to work when I do a show int it says its full duplex however I'm stil seeing 20 - 40% packet loss on the link which suggests to me there is still a speed/duplex issue. The device at the other end is a Cisco 7200 which is set to 100Full. If I plug a Cisco 2811 into the fibre link I get zero packet loss which suggests its a problem with the switch.
I have changed the modules and fibre cables which makes no difference. As I stated at the start I have two 2960's both are showing exactly the same issue. Details of the switch are below the SFP are cisco branded:
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 28 WS-C2960S-24TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M
interface GigabitEthernet1/0/25
switchport trunk allowed vlan 380,382,384,386
switchport mode trunk
duplex full(code)
View 18 Replies
View Related
Apr 6, 2013
we have two 6509E which are configured in VSS mode with the following modules in each:
1 48 CEF720 48 port 10/100/1000mb Ethernet
2 8 DCEF2T 8 port 10GE
3 4 CEF720 4 port 10-Gigabit Ethernet
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G
I need to know if the temperature of the attached modules are normal or there is a problem?
the status of one of the supervisor engines is "MajFail" as shown below:
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Major Error
View 3 Replies
View Related
Mar 6, 2012
I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.
View 1 Replies
View Related
Dec 12, 2011
Is there a chart to show what modules will fit what swithches for fiber applications ex 2950 and 3560 switches
View 1 Replies
View Related
Jan 21, 2012
As per my understanding 6509 all slots are dual channel, so 9 slot * 40 per slot (20 g in and 20 g out) = 360 GB How cisco claim the 720 ?? What about the 6513 chassic switch fabric connection?
View 5 Replies
View Related
Sep 20, 2012
I am seeing a strange situation on my 6500 switch?By having snmp walk on '1.3.6.1.4.1.9.9.109.1.1.1.1.3' (== cpmCPUTotal5sec), I came to know that there are two processor and the cpu util for switching processor is gone to 88 % and some time creeps to 99 %.
snmpwalk -v2c -c "removes" sw6500 '1.3.6.1.4.1.9.9.109.1.1.1.1.3'
SNMPv2-SMI::enterprises.9.9.109.1.1.1.1.3.1 = Gauge32: 12 (--- this is for CPU of Router Processor )
SNMPv2-SMI::enterprises.9.9.109.1.1.1.1.3.3 = Gauge32: 99 (--- this is for CPU of Switching Processor )
but when I do sh process cpu on the console, all looks normal as it shows cpu utilization of RP. why the value is so high on the switching processor ?
View 1 Replies
View Related
Jan 24, 2013
For intervlan routing, Is 'IP routing' command enabled by default on a 6500 series switches based on the IOS?and on 3750 switches, do we need to enable the "ip routing" command manually for intervlan routing?
View 1 Replies
View Related
May 9, 2013
I'm looking to restrict Inter-VLAN routing through L3 switch (cisco 6500) and wanted to know best possible way to do it. I used VACL and achieved success to some extent, but my config is making clients take up to 5-6 mins to authenticate IP address from the DNS (bootps).My VACL config was as follows:
Subnet to restrict is 10.100.15.0 (VLAN 15)
STEP 1: Created extended ACL to allow bootpc/bootps through DNS
ip access-list extended EACL_DNS
permit udp any eq bootps any
permit udp any eq bootpc any
STEP 2: Created standard ACLs to allow only relevant subnet, server VLANs & some IPs from other subnets for printers/scanners etc.
ip access-list standard SACL_VLAN_15
permit 10.100.15.0 0.0.0.255 (the subnet I'm restricting)
permit 10.100.50.0 0.0.0.255 (server VLANs)
permit 10.100.25.45 0.0.0.0 (printer in another VLAN which has to have access in VLAN 15)
STEP 3: Created VLAN access list
vlan access-map VACL_15 10
match ip address EACL_DNS
action forward
vlan access-map VACL_15 20
match ip address SACL_15
action forward
STEP 4: Applying VLAN Access list on VLAN 15 vlan filter VACL_15 vlan-list 15 Though the above works, below is noted:
1. I'm still able to PING 10.100.15.2 (the switch virtual interface) from outside the subnet, which I don't intend to do so. Howeve all cients in the subnet have no connectivity from outside the VLAN 15.
2. As mentioned its taking quiet some time to negotiate with the DNS server at system boot time.
View 3 Replies
View Related
Jun 2, 2012
I used to "ip routing" command in order to enable inter-vlan routing, for example with 3750 cisco. I have a 6503 cisco with SUP720 MSFC3. I was able to create some vlans but I can not configure inter-vlan routing.
sw#conf t
Enter configuration commands, one per line. End with CNTL/Z.
swsur(config)#ip routing
[Code]....
View 3 Replies
View Related