Cisco Switching/Routing :: 2600 / 3640 WIC-2T Configuring Serials Modules
Feb 5, 2012
How to configure my serial modules on my 2600 and 3640? Each router has the WIC-2T with two cables connecting them. I tried to ping one router from the other, but no luck. Serial IP address I just made up, this is my home lab, so if I messed those up some how,
Here is the running config for each rotuer:
2610:
Current configuration : 1071 bytes
!
version 12.3
[Code]...
View 22 Replies
ADVERTISEMENT
Apr 28, 2013
I'm using 3640 router running on c3640-js-mz.124-25d.bin IOS. I'm using NM-1A-OC3SML= (ATM OC3, long reach single mode) interface card. Now my pc is connected an fast ethernet interface of the router. Need to know the ATM configuration on this cisco 3640 router in order to achieve the ATM over ethernet traffic get success. As of now i've confugred as below but it's not working it seems.
interface ATM2/0
bandwidth 120000
ip address 10.2.2.1 255.255.255.0
no atm ilmi-keepalive
pvc 0/36
protocol ip 10.2.2.10 broadcast
cbr 70000
encapsulation aal5mux ip
let me know the correct encapsulation type for the connectivity.
View 2 Replies
View Related
Sep 23, 2012
The Cisco 3600 series (3640) is hanged during booting proccess, the IOS is decompressed, but after some text it hanges and I even cannot go to user exec. ROMmon and bypassing the config setting, but the result is still the same.
View 5 Replies
View Related
Mar 21, 2013
I got this 3640, trying to apply a service-policy (output and input), but seems like I do it something wrong...because he only apply the output policy... here the config, I already try to config the service police inside the fa0/0, but is not showed at all, he only show the output, its like I never apply that
View 1 Replies
View Related
Apr 8, 2013
I got some unexpected System crash, and this happens to 2 different routers on the same network.. (We suffer a Crash and change the router, happens the same to the new router after some time, maybe 40 minutes!!)
Here is the last console report for the new router....
%Software-forced reload
Preparing to dump core...
4w1d: %SYS-2-WATCHDOG: Process aborted on watchdog timeout, process = IP NAT Age
[Code]....
View 3 Replies
View Related
Nov 1, 2011
We have a Cisco 3640 router running c3640-is-mz.123-3g.bin Switching ports are devided into several VLans. Each VLan has its own IP subnet. We can't ping IP address X in subnet A from subnet B unless we log into the router and ping it from there first. (and then the IP address will show up in "show ip arp" command. Then we can ping X in subnet A from subnet B, and browse web on device X from subnet B, etc. )
View 6 Replies
View Related
Oct 1, 2012
i am running c3640-is-mz.124-21.bin on a cisco router 3640. i am trying to create a monitor session in the CLI and everytime i type the command Router(config)#monitor session 1 interface ethernet2/1 % Invalid input detected at '^' marker. Router(config)#monitor session 1 interface ethernet2/1 ^% Invalid input detected at '^' marker. i get the error invalid input ?
View 10 Replies
View Related
Dec 6, 2011
So I have 2 routers (cisco 3640) that each go to their own ISP and then back to the same switch. I have setup ospf and glbp, and now have pretty good redundancy. If either internet connection or routers go down everything is still golden.
So I was thinking that if an interface went down then the router would not be load balanced with glbp which got me thinking whats the best way to get interface redundancy (and I was going to add a 2nd switch with the second interface).
1) Setup BVI on the 2 interfaces.
2) Setup a 2nd interfaces (on each router), I would have to split the subnet, for instance: [code]then the machines could be on the subnet 192.168.0. 0/23 and setup glbp for 1 ip across all 4 interfaces (I'm not even sure if you can do this but think it would work).
3) Is there a way to utilize etherchannel or anything like this
A negative to option 2 would be that if 1 of the interfaces went down, all the sudden 2/3 (or so) of your traffic would be going through 1 router.
View 5 Replies
View Related
Dec 28, 2011
I have two routers at our core data center, a 3845 and a 3640. These are configured with GLBP. There are 4 remote sites:
Site #1: One T1 link to the 3825
Site #2: One T1 link to the 3825, and One T1 link to the 3640
Site #3: One T1 link to the 3825, and One T1 link to the 3640
Site #4: One fractional T1 link to the 3825, and One T1 link to the 3640.
My question regards site #4. If i understand correctly, GLBP works on the premise of "host" balancing, and not true "load" balancing. The reason I ask is that the large majority of our WAN traffic is from our Exchange server to our remote sites. In the case of site #4, our exchange server is sending traffic on the fractional T1. Is there any way with GLBP to either split this traffic from a particular host across two links in a round-robin fashion, but leave other hosts to travel wherever the router sends them, or, to force at least our exchange server to use the full T1, rather than the fractional?
I've read up on the weighting mechanism, and it appears that tracking an interface has nothing to do with bandwidth use. If I understand correctly, if I were to track the Site #4 PPP to the 3640, and give a weight of 10 to glbp on there, it would really only take affect if the interface is down. It will have nothing to do with host AVF election.For the record, exchange traffic is constant to this site, so there is no chance for the host connection to reset and potentially elect to use the larger pipe. I would like to "tweak" this to make better use of available bandwidth.
View 2 Replies
View Related
Jun 25, 2012
I have the cisco 3640 with IOS Version 12.2(46) , and it with DRAM:32M , Flash:8M.What IOS version can support IPv6 RIP in the hardware limit?
View 3 Replies
View Related
Mar 4, 2012
i want to configure the router for internet access for hosts this is the my pub ip x.x.x.174 and mask 255.255.255.252 this is isp given subnetmask internal ip range is x.x.x.20-x.x.x.254
View 1 Replies
View Related
Feb 7, 2013
I have a WS-C4510R+E with
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 48 10/100/1000BaseT Premium POE E Series WS-X4748-RJ45V+E CAT1612L1JD
2 48 10/100/1000BaseT Premium POE E Series WS-X4748-RJ45V+E CAT1612L1JW
3 12 10GE SFP+ WS-X4712-SFP+E CAT1622L0SC
4 12 10GE SFP+ WS-X4712-SFP+E CAT1622L0RM
5 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7-E CAT1620L1UJ
6 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7-E CAT1620L1Z2
Can i add two WS-X4712-SFP+E and two 10 GE ethernet module also?
Is there 10GE ethernet module with WS-C4510R+E.
View 2 Replies
View Related
Dec 14, 2011
Here i have a customer who has 7609 router with modules
ws-+6748-ge-tx
ws-svc-wism-1-k9
ws-sup720-3b
ws-sup720-3b
ws-svc-wism-1-k9
ws-6724-sfp
ws-x6704=10ge
ws-x6724-sfp
will this modules will be supported to the new chaisis ios or in the chaisis 7609S
View 1 Replies
View Related
Mar 21, 2011
last weekend i configured HSRP on our default gateway(Cisco 2600) and now i have the problem that the latency is constantly at 3ms and from time to time it goes up to 10 ms. Is that something i should have expected or is there someting wrong with my configuration? The standby ip adresses are the same adresses as the router interfaces had before and the CPU utilization is at 10 % so i do not know what happend here. I atached the config file so if you need further information i will gladly provid it.
View 4 Replies
View Related
Nov 23, 2012
we have a old Nexus 5010 running version 5.0(3)N1(1)it is in a franckenblock(like frankenstein) ie . we bought the parts and create our own system design before VCE was created. He have since bought VCE V block for our production sites. we use the franc ken block to test before we migrate to the production v block 300 FIX the issue we have is the 5010 will only see two 1 Gb/s SFP fiber modules in the first 12 slots. All these slots are dual 1g/10G. If we add more than two, it claims not to see them. We tried swapping the sfp and using both sfg-GE-MM and GLC-SX-MM moduels, no difference at all 1g sfp are in the first 5 slots. only the first two slots are up.the others say "Link not connected" or "SFP not inserted"all five links are the same SFP and are plugged in other switches.the green link lights are on plugged in SFP, even when the CLI states they are not plugged uni tried both two types of 1 Gb/s SFP. sfg-GE-MM and GLC-SX-MM ,i move the sfp between slot 1,2 and 3,4,5. nothing changed,From "sh int brief" you can see that it can see the sfp ie they are all 1Gfrom "sh int status " it sees 1g but why does it say type 10G?why when i go to the "int e 1/5" and try switch port mode now, it can't mode and trunk at now there (;also how to i stop or clear EU51 %SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is unexpectedly high at 87%.i put as much info in the attached file as i could.
View 1 Replies
View Related
Mar 4, 2013
I am having issues trying to combine two modules into one VDC. The modules are as mentioned below: When I try to combine module 1 & 10 as shown above, the nexus 7000 switch displays 'Not compatible'. I've read the online guide and it mentions that the F2 and M1 module cannot be combine into the same VDC. Problem is, my customer has already purchased the module, how do i solve this problem? If I separate the VDC, how does module 1 talk to module 10 if user wants to send traffic to Internet or Server Farm?
View 3 Replies
View Related
Sep 17, 2012
Is it possible to implement LLQ(QoS) on ethernet modules in the Cat 6500? For this feature, I can only find documentation about ES+ modules or SPA/SIP modules! (according to the feature navigator LLQ is supporten on the concerning HW and SW image)
View 2 Replies
View Related
Apr 29, 2013
I am working on a project to connect 2 switch stacks via 10 Gb fiber. I am told that the 3750Xs do not natively receive the 10 GB SFPs. What part numbers do i need to order to make this work? Is there any IOS image requirements?
View 14 Replies
View Related
Mar 11, 2013
is there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies
View Related
Dec 12, 2012
While configuring PoE Ethernet EHWIC PoE modules with ISR G2 routers Cisco DCT gives a warning to select AC Power Supply with PoE ‘PWR-3900-POE’. Do we need to select the PoE power supply for Enhanced EtherSwitch SM PoE modules also (at present it does nt show any warnings)?
View 1 Replies
View Related
Jun 3, 2013
I have already understood the following notice for using VSS function with 6700 series modules.For example there is the compatibility HW revision issue between the 6700 line card and CFC or DFC and so on. [code]
View 1 Replies
View Related
Nov 15, 2011
how to identify which modules are supported by cisco catalyst 6500. is there any OID which can give us the information
View 2 Replies
View Related
Sep 5, 2012
our network is spread over 15 floors and each floor we have 5-6 switches. we are planning to purchase cat3750-x 24 ps poe with C3KX-NM-10G network modules. Each floor has two up links to the core switch with single mode fiber and other being the multimode.Suppose if we are purchasing 75 switches do we have to purchase 75 C3KX-NM-10 G modules.? or can we limit our purchase with 15 C3KX-NM-10G sothat two uplinks from each floor can be made? since network modules are optional cost factor is invovled. Or any issue with stacking ? the SFPs will be LR and LRM MODULES.looking for an answer ? whether the new usb type console cable comes bundled with cat350x or shall we have to order separately?
View 7 Replies
View Related
Jan 23, 2011
We currently have two 6509's running in VSS, both switches have a WS-6748-GE module in slot 3. I'm in the processing of removing these modules. I will then be replacing them with a different module type, but I need to know how to remove the old configuration of the previous modules.
View 4 Replies
View Related
Apr 22, 2012
I have a question. I have a 6500 with two supervosrs and they both have CATOS. One of them failed and I need to replace. As long as the hardware is the same does the CATOS have to be indentical or can this be different.
View 4 Replies
View Related
Oct 8, 2012
I've installed second WS-X6748-SFP linecard on my catalyst 6509 with sup720-3b and after that NAM-2 and IDSM-2 module become inaccessible from management network. I can only login with session slot N proc 1.When I execute #hw-module module 4 reset, modules become accessible.
#sh module from cat6509
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
2 48 CEF720 48 port 1000mb SFP WS-X6748-SFP SAL114670XW
3 48 48-port 100FX SFP Ethernet Module WS-X6148-FE-SFP SAL1201BZKF
4 48 CEF720 48 port 1000mb SFP WS-X6748-SFP SAL1625ETFJ
5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1206FNGQ
6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAL1206FVFB
8 8 Intrusion Detection System WS-SVC-IDSM-2 SAD120502LR
9 8 Network Analysis Module WS-SVC-NAM-2 SAD120206LB
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
2 001e.4a3e.3b30 to 001e.4a3e.3b5f 1.10 12.2(14r)S5 12.2(18)SXF1 Ok
3 001e.4aea.e7b0 to 001e.4aea.e7df 3.3 8.4(1) 8.5(0.46)RFW Ok
4 5057.a895.bb84 to 5057.a895.bbb3 2.4 12.2(18r)S1 12.2(18)SXF1 Ok
5 001c.58d0.6dc4 to 001c.58d0.6dc7 5.6 8.5(2) 12.2(18)SXF1 Ok
6 0016.c848.3698 to 0016.c848.369b 5.6 8.5(2) 12.2(18)SXF1 Ok
8 001e.f7a1.54b0 to 001e.f7a1.54b7 6.3 7.2(1) 7.0(8)E4 Ok
9 001e.f72a.ba62 to 001e.f72a.ba69 4.3 7.2(1) 5.1(2) Ok
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
2 Centralized Forwarding Card WS-F6700-CFC SAL114881B6 4.0 Ok
4 Centralized Forwarding Card WS-F6700-CFC SAL1624EGQS 4.1 Ok
5 Policy Feature Card 3 WS-F6K-PFC3B SAL1206FNZY 2.3 Ok
5 MSFC3 Daughterboard WS-SUP720 SAL1206FSFH 3.1 Ok
6 Policy Feature Card 3 WS-F6K-PFC3B SAL1206FP27 2.3 Ok
6 MSFC3 Daughterboard WS-SUP720 SAL1206FN26 3.1 Ok
8 IDS 2 accelerator board WS-SVC-IDSUPG ADBG7270048 2.5 Ok
cat6500 running 12.2(18)SXF12a ios...
View 8 Replies
View Related
Jun 13, 2012
We have many 3750E's and need to use Finisar X2 modules FTLX8541E2. After 15.0(1) IOS upgrade the 3750's now recognize the Cisco part X2-10GB-LRM's, but will not recognize our Finisar modules.
View 1 Replies
View Related
Apr 27, 2013
Configuring HP switches for Flexconnect. I am not sure if or not its doable? Access Points are 2600 and 3600 with 5508 as a controller. Idea is to keep the branch traffic local but the switches are HP.
View 3 Replies
View Related
Oct 14, 2012
I recently ran an upgrade on my 6509-E's and when the first switch came back up, 3 of the 10/100 switches that were in the chassis did not power on. After further investigation, these models are not supported by this latest IOS version. The module # is : WS-X6248-RJ-45
We have one WS-X6348-RJ-45 and since it was a few weeks ago I did this I can't remember for sure but I believe this one came up.
Where can I found the information regarding this being unsupported but I know it is out there and any page that showed me that this was unsupported with the latest stable IOS of 12.(33).
In addition to this question, I have approval to purchase some newer gigabit switches that will be supported by this new IOS version and hopefully at least the next few over the next few years. Which specific gig models are currently and hopefully should be supported for the next few years? I don't need PoE or anything spectacular, just regular switches that are attached to either servers or virtual hosts. I've been looking at the lists of what is out there and it seems like there are hundreds of different models and it is becoming difficult to determine what is what.
View 1 Replies
View Related
Mar 20, 2012
How to get fiber optic modules for Cisco 2821 series router. I can not find anything apart a SFP module which contains only one SFP port.
View 9 Replies
View Related
Apr 19, 2013
I have two 2960-s switches with GLC-FE-100FX fibre modules in and I am seeing packet loss over the link that is connected to the modules. When the interface is shutdown and brought back up it always comes up in half duplex even thought it is set to full in the config. I've seen other posts where you have to use the command no duplex then full duplex to get it to come up int full duplex. This does appear to work when I do a show int it says its full duplex however I'm stil seeing 20 - 40% packet loss on the link which suggests to me there is still a speed/duplex issue. The device at the other end is a Cisco 7200 which is set to 100Full. If I plug a Cisco 2811 into the fibre link I get zero packet loss which suggests its a problem with the switch.
I have changed the modules and fibre cables which makes no difference. As I stated at the start I have two 2960's both are showing exactly the same issue. Details of the switch are below the SFP are cisco branded:
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 28 WS-C2960S-24TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M
interface GigabitEthernet1/0/25
switchport trunk allowed vlan 380,382,384,386
switchport mode trunk
duplex full(code)
View 18 Replies
View Related
Apr 6, 2013
we have two 6509E which are configured in VSS mode with the following modules in each:
1 48 CEF720 48 port 10/100/1000mb Ethernet
2 8 DCEF2T 8 port 10GE
3 4 CEF720 4 port 10-Gigabit Ethernet
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G
I need to know if the temperature of the attached modules are normal or there is a problem?
the status of one of the supervisor engines is "MajFail" as shown below:
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Major Error
View 3 Replies
View Related
Mar 6, 2012
I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.
View 1 Replies
View Related