Supervisor Engine 720 options support centralized forwarding rates up to 30Mbps and distributed forwarding rates up to 400Mpps. I never understood the claim of forwarding rate logic in mbps. How i can load the 6509 box to check this forwarding rate?How can the performance increase from 30mbps to 400mbps? is this just because of DFC on all the line cards if yes does it mean i have to add the DFC on SUP as well .
View 3 Replies
ADVERTISEMENT
Jul 5, 2011
I currently have a dlink dir-655 in my basement. my computer on the second floor is connected via DWA-160. I Only have around 2-3 signal bars, and never get the 300mbs like described. i would like to know all the possibilities to extend my range (to have 5 bars) or get better connection speed. do you recommend an access point or an extender? Which models? also, if i have an dir-615, can i use it as an acesspoint/range extender for my computer on the 2nd floor? if so, how? I am looking for the cheapest alternative in order to have better signal and speed. The modem is stuck in the basement therefore I cannot move it.
View 3 Replies
View Related
Jul 21, 2012
Does Cisco ASA 5510 and 5505 has module for increase performance VPN ?
View 3 Replies
View Related
Aug 30, 2012
I will use function of span in sup70-3b.How many session can use in sup720-3b? For example, 2 or 4 session.
View 1 Replies
View Related
Dec 10, 2011
How can i find the serial number of sup-720 which is totally dead and not boot?By which sticker on SUP and where ? How many digits ?
View 4 Replies
View Related
Mar 19, 2013
I have a SUP720-3BXL that will not boot. It will get stuck at booting from the SP. It never switches over to the RP. [code]
View 5 Replies
View Related
Dec 1, 2011
I have received a sup720-3B from Cisco with an internal 512MB flash(sup-bootdisk). I want to verify what IOS image is on the disk and do not have an spare 6509 chasis. Can I remove the 512 MB flash disk and insert it to my disk0: on my production 6509 with the sup32 that the 720 will repplace and view what is on the disk without corrupting?
View 7 Replies
View Related
Sep 11, 2012
when using "show mls statistics" I see a lot packets are getting L3 Processed. Does that mean they are getting software-forwarded?
IOS is 12.2(33)SXI5.
Cat6k#show mls statistics
Statistics for Earl in Module 5
L2 Forwarding Engine
[Code]....
View 1 Replies
View Related
Oct 26, 2011
I got a new VS-S720-10G it had 122-33.SXH8b on there. I had to downgrade it to 12.2.33.SXI1 to match our other switches. I installed the file I use in all the other switches, s72033-adventerprisek9_wan-mz.122-33.SXI1.bin but the Sup is now is only booting up only to ROMMON mode.
Initializing ATA monitor library...
Self extracting the image... [OK]
Self decompressing the image : #################################################
################################################################################
################################################################ [OK]
%SYSTEM-1-INITFAIL: Network boot is not supported.
System Bootstrap, Version 8.5(4)
Copyright (c) 1994-2009 by cisco Systems, Inc.
Cat6k-Sup720/SP processor with 1048576 Kbytes of main memory
[code]....
How do I get the older version of IOS to load up?
View 5 Replies
View Related
Nov 16, 2011
I have problem with the standby supervisor in 6500 vss and need to replace the supervisor. I have follow how-to on the cisco web site url...
But when i boot the new standby sup720 it comes active and both supervisors is rebooting. I wonder if i can do the replacement without rebooting both active and standy supervisor.
View 1 Replies
View Related
Feb 27, 2013
Trying to find documentation on the proper procedure for installing a second sup720 into our 6509-E chassis for sup redundancy. I have found documents that tout how 'cool' and 'awesome' NSF/SSO, and all that is, but haven't found any docs on installing a second sup720 into a chassis that is currently in production and is only running one sup720. In all the years that this chassis has been out, there must me a documented procedure out here to explain this.I have been through the following pages, and have found nothing to this effect.
View 1 Replies
View Related
Nov 29, 2011
problem to configure MWAM. I have installed MWAM module in 6506-E slot 2 with sup720-3B. After installing MWAM the Status is PwrDown. I tried to turn on the power but its not happening. MWAM is installed in slot 2 and here is the result of show module 2 My Sup720-eB IOS image is s72033-advipservicesk9_wan-mz.122-33.SXJ1.bin
6506-E#show module 2
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
2 3 MWAM Module WS-SVC-MWAM-1 SAD081203GK
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
2 0003.feae.bb8c to 0003.feae.bb93 3.0 Unknown Unknown PwrDown
Mod Online Diag Status
---- -------------------
2 Not Applicable
View 2 Replies
View Related
Jan 23, 2012
We are close to receiving our new 6513E chassis which I will be running Sup720 cards in. This will be replacing our existing 6509 Sup2 setup in production. What current IOS version should I run on the Sup720 ? I would like to support SSH. The chassis will be populated with a couple of 6724 SFP cards, 2 6704 10 gig cards and a few 6748 line cards.Is there a good intitial config guide ?
View 6 Replies
View Related
May 26, 2012
Customer is using SUP720 with SP rommon image version 8.1(3), he is trying to boot the new ios image from disk0, but he gets invalid magic error. he fomat the disk0 but still he gets error when he boots from disk0. He suspect that it can't be flash problem but can be software of hardware as he has two flash with same issue on 2 switches.
Customer wanted to recreate, I tried in the lab, i was able to load from disk0, but sup in lab had 8.5(4).
Customer wanted me try with 8.1(3) version. But i was unable to downgrade the SP Rommon image. SP rommon is running in Gold region and I loaded the 8.1(3) from both disk0 and sup-bootdisk, even preferrence was given to region1 but still sup came up with gold region itself.
* Will i be able to downgrade from 8.5(4) to 8.1(3), if so, what are the steps.
* is there any limitation or bug where 8.1(3) will be unable to read disk0.
View 4 Replies
View Related
Jan 13, 2008
Just a very quick one. Is there any physical limitation to how many ARP entries a 6509 and sup720 can have?
View 4 Replies
View Related
Jan 24, 2007
if it is possible to recover a Cat 6500 that has no code on bootflash from ROMMON, and is it mandatory to have a compact flash card to do the recovery ? or can one use xmodem or TFTP ?
View 6 Replies
View Related
Jun 4, 2013
I'm trying to boot this IOS on a 6506-E, s72033-adventerprisek9_wan-mz.122-33.SXI8.bin.
This is what I see in bootvar.
sh bootvar
BOOT variable = disk0:s72033-adventerprisek9_wan-mz.122-33.SXI8.bin,1;disk0:s72033-ipservicesk9-mz.122-18.SXF8.bin,1;
CONFIG_FILE variable =
BOOTLDR variable =
Configuration register is 0x2102
Standby not ready to show bootvar, I want to remove SXF8 and leave SXI8 alone. I removed both IOS file names in boot system and added the SXI8 again and saved. So this would be the output after.
But after a switch restart, this would be the output of show bootvar again.
sh bootvar
BOOT variable = disk0:s72033-adventerprisek9_wan-mz.122-33.SXI8.bin,1;disk0:s72033-ipservicesk9-mz.122-18.SXF8.bin,1;
CONFIG_FILE variable =
BOOTLDR variable =
Configuration register is 0x2102
Is there anything I need to check? This is an old engine and I'm not sure if the variables of the RP modified .
View 12 Replies
View Related
Mar 11, 2012
Cisco Safe harbor, I came nto know this can be a replacement for Sup 720.
View 2 Replies
View Related
Mar 27, 2013
I am having problems with IGMP and QoS on CAT6500 platform with SUP720 engine.The problem is, it seems that all IGMP packets are getting marked with DSCP 48 when sent out of the switch regardless of any input service policy. I found several articles saying that PFC QoS does not apply to IGMP packets. However in IOS 15 that should be possible, but I didn't get it to work there either. [code]
View 0 Replies
View Related
Nov 29, 2010
I have a heck of a time finding this kind of information on the cisco site...Is the WS-SUP720-BASE line card a fully supported module in the 6509-E chassis?
View 4 Replies
View Related
Jun 14, 2012
Running WS-F6K-FE48-AF InlinePower daughtercards with SUP720-10G?
The release notes mention that the following daughtercards are supported:
WS-F6K-GE48-AF
WS-F6K-48-AF
[URL]
But, specifically, the WS-F6K-FE48-AF is not mentioned.
We need to upgrade the supervisor in multiple 6500 chassis full of WS-X6148-21AF modules with WS-F6K-FE48-AF daughtercards, and we want to make sure there are no compatibility issues.
View 0 Replies
View Related
Apr 28, 2013
We recently purchased 2 Cisco 6500 series switches (with Sup 2T). These switches will be replacing our old 2 6500 series switches (with Sup 720).
We have 70 vlans and 90+ closet switches (2900) connecting the core switches We have 2 WLC connected to the core switch. We also have a 1 x 1 connection to a VSS switch which in turn connects to our Server Co-Location data center utilizing IPSec & GRE tunnel to connect to our Server Co-Location data center.
Our routing protocol is EIGRP. Our VTP domain at Server Co-Location is separate from our location “A” campus. I was wondering what is the best way to migrate our Core switches at location “A” campus.
The requirement is we would like to replace these switches with minimum downtime.
View 6 Replies
View Related
Mar 29, 2012
I have Cisco 6513 with sup720 running s72033-adventerprisek9_wan-mz.122-18.SXF8.bin. I would like to upgrade with the latest and stable IOS.
View 5 Replies
View Related
Jun 21, 2012
I support an active VSS cluster using 2 x 6509E chassis with single Supervisor 3C modules in each chassis. I want to replace these with Supervisor 2T modules. All my service modules and line cards are supported with the Sup2Ts (I will also be implementing 6908 modules). Is there a document on the Cisco site for this? I haven't found one though I can find plenty that describe how to do a software upgrade.
(Note, I have a 3rd (non VSS) 6509E chassis that is also part of this core network and that will maintain VTP/V LAN's etc).
View 9 Replies
View Related
Aug 28, 2012
Is it possible to have one netflow export profile (may not be the right word...) to send all the flow information to one collector and another profile to only send traffic to and from centain IP addresses to another collector? If it is possible on the hardware and software, any quick sample config?
#sh ver
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXH4,
#sho module 7
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
7 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1115LJBR
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
7 0017.9444.9814 to 0017.9444.9817 5.3 8.4(2) 12.2(33)SXH4 Ok
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
7 Policy Feature Card 3 WS-F6K-PFC3B SAL1115L2NH 2.3 Ok
7 MSFC3 Daughterboard WS-SUP720 SAL1115LH7W 2.6 Ok
Mod Online Diag Status
---- -------------------
7 Pass
View 2 Replies
View Related
Mar 25, 2012
I faced with problem while i was attemping to upgrade CISCO7606 (R7000) from 12.2(33)SRE1 to 12.2(33)SRE6.
rommon 2 > boot c7600s72033-advipservices-mz.122-33.SRE6.bin
Loading image, please wait ...
Invalid device specified
Booting from default device
Initializing ATA monitor library...
string is bootdisk:c7600s72033-advipservices-mz.122-33.SRE1.bin
[code].....
View 3 Replies
View Related
Oct 24, 2012
I'm fairly new to networking and need to migrate an old core to a new core. I have a 6509-e Switch that I had an RMA on one of my 720 sup cards. After receiving the sup card I swapped my slave out with the new one, expecting it to boot into ios. It booted into Roman. I tried to boot the image manually and it did the same thing. I also tried to boot from my flash and, again, booted into ROMmon.
Question: If i configure and change the boot to boot from image it tells me i need to reset or power cycle first. Will this reset the entire switch? As this is production I'd rather not.
I am at home now, but I can supply any logs/hardware model/configs tomorrow. I thought I would see if this is an easy fix.
View 23 Replies
View Related
Dec 8, 2011
I have 2x v10000 Websense Security Gateways that are connected to 2x 6500 SUP720. When I turn on cluster management function between Websense appliance, they speak to each other only if they are connected in the same 6500. When they are connected one in every 6500 cluster management does not work. They are connected on the same physical vlan. Do I need multicast to be configured in the 6500 switches?
View 5 Replies
View Related
Oct 16, 2012
I got a Cisco 2960-S LAN (support PoE+) switch installed in one of my customers' office. The customer needs to plug some cameras to the switch and need inline power from the swtich.
Two of the cameras requires 24W power in order to work correctly, if just use normal PoE power, can't get all functions working and get an error message on the screen says "not enough power" or something like that. I have configured those two port to static power inline (on a max value which is 30W). Once the configuration applied, shut/ no shut the port, the error message disappeares for a few minutes, and then comes back. Looks like the power level is still on PoE not PoE+.
Is there anything I can do on the configuration to increase the inline power and provide a stable power to that kind of devices?
SW02#sh power inline
Module Available Used Remaining (Watts) (Watts) (Watts) ------ --------- -------- ---------1 370.0 141.7 228.3Interface Admin Oper Power
[Code]....
View 1 Replies
View Related
Aug 9, 2012
I am looking to replace the active supervisor (S720-10G) on our 6509E running in SSO mode. The new module already has the same IOs version as the standby supervisor.Once I have swapped the module how do I know that the config has sync'd correctly other than checking the logs? Is it a case of looking at the "Redundancy Mode (Operational)" state and ensuring is says SSO?Also, is there a command that will force a config-sync if it is running in a mode other than SSO?
View 1 Replies
View Related
Feb 24, 2013
I have a two fiber connection from our Central Office(6513) to Remote office (6509). I have a requirement that on the remote office if one of the fiber goes down, the second fiber should work as a failover. I am planning to use SUP720-3B SFP to connect to the CO.
Can I connet one fiber to Sup720-3b G5/1 & another fiber connection to G5/2? or Can I connet one fiber to Sup720-3b G5/1 & another fiber connection to G6/2? I am running EIGRP between sites. Any sample config.
sup-bootflash:s72033-pk9sv-mz.122-18.SXD7b.bin"
View 4 Replies
View Related
Oct 28, 2012
I have one Catalyst 6509E chassis and two SUP720. The bootup sequence on SUP 720 (standby hot) failed . Messages that appear on SUP 720, on the console port indicate o software crash. I don't have a flash card in SUP720.
This is the bootup process:
System Bootstrap, Version 8.5(3)
Copyright (c) 1994-2008 by cisco Systems, Inc.
Cat6k-Sup720/SP processor with 1048576 Kbytes of main memory
[code].....
View 1 Replies
View Related
Mar 6, 2012
When mutiple Policy based routing configured on 7600 routers, did the router performace degraded with the number of policy based routing rules?Also, did 7600 running 12.x use per-flow based routing or per packet based routing?
View 1 Replies
View Related