Mar 7, 2012

I have been having some issues trying to stand up an older WiSM that has been incorrectly configured by my predecesssor and has a bad Mgt IP so I am unable to telnet or SSH into it, nor can I console or session into it.
 
What I would like to do is to change the Mgt address for the WiSM controllers (1 and 2) by way of the Sup (not sure that is possible) because as it stands they are set to 169.254.1.1 and are unreachable even when directly consoled into them.
 
Core-A#sh wism status
 
Service Vlan : 52, Service IP Subnet : 10.104.52.2/255.255.255.0
      WLAN
Slot  Controller  Service IP       Management IP    SW Version  Status
-------------------------------------------------------------------------------------------------------
3           1       10.104.52.3         169.254.1.1          4.0.217.0    Oper-Up
3           2       10.104.52.4         169.254.1.1          4.0.217.0    Oper-Up
 
Core-B#sh wism status
 
Service Vlan : 52, Service IP Subnet : 10.104.52.1/255.255.255.0
      WLAN
Slot  Controller  Service IP       Management IP    SW Version  Status
-------------------------------------------------------------------------------------------------------
3          1       10.104.52.50        10.104.30.254      7.0.116.0    Oper-Up
3          2       10.104.52.51        10.104.30.250      7.0.116.0    Oper-Up
 
I hope to get this WiSM setup on Core A and get it configured like I have my Core B and then run them in a dual failover design with load balancing between the two.

View 6 Replies


ADVERTISEMENT

Cisco :: 1252 Wireless AP Resetting To Factory Default

Jan 5, 2012

I have a used 1252 wireless AP.  I can't get into it.  How do I reset to factory default?

View 1 Replies View Related

Linksys Wireless Router :: WRT54G Resetting To Factory Default By Itself?

Aug 11, 2008

I have a WRT54G router Ver. 5 with firmware v. 1.02.5.  This is the second time this has happened to me but the router reset itself to the factory defaults. I lost all my configurations.   I'm saving the configuration this time but it will be annoying to keep having to reconfigure the router.

View 9 Replies View Related

Linksys Wireless Router :: Resetting WRT54G To Factory Defaults?

Jun 23, 2008

I reset my WRT54G wireless router, so I could use the default password for 192.168.1.1 and the default password and username still do not work.

View 6 Replies View Related

Linksys Wireless Router :: WRT160Nv3 Constantly Resetting To Factory Defaults?

Jan 9, 2010

WRT160Nv3 Firmware Version: v3.0.02  
 
I've been using Linksys for years but the last two routers I have purchased have been very problematic.
 
- My router hasn't had this problem before. The other day I was downloading 4 games at a time from STEAM, when I got home from work I found that my router had completely gone back to factory settings.  So I configured my DSL PPPoE, SSID, Wireless Security (WPA) changed the default admin PW and about 20 minutes later it was back to factory again.
 
I've done a "hard" reset and reconfigured and still it resets itself. What's also upsetting is this completely opens my network up to ANYONE when this happens...
 
So far in the past 2 days I have (now using a backup restore file) re-configured the device 10 times.
 
The only thing I can think of is that I just got Windows 7 the same day this started happening. I thought it could be STEAM as well so right now I have STEAM closed to see if it resets while it isn't running.
 
Could TOO much demand on the router cause it to completely reset itself to factory config?? Seems to me like there's a huge firmware or hardware problem here.
 
I have other friends and even co-workers that also have problems galore with their Linksys products...No other router it seems has as MANY issues as Linksys. Hat to say it but my next purchase most likely will not be another one of their products. This just shouldn't be happening.

View 5 Replies View Related

Cisco Wireless :: 6509-E / WiSM Controller Unreachable From WCS

Jan 26, 2013

I am getting an alarm on WCS where a one controller is down, unreachable from WCS, while the other one is reachable on the same WiSM module. Upon investigation, Status of controller is shown as "Oper-Up" for all controllers on Supervisory engine. Hardware platform is Cisco 6509-E.
 
     WLAN
Slot  Controller  Service IP       Management IP    SW Version  Status
----+-----------+----------------+----------------+-----------+---------------
2     1           192.167.10.11    172.19.47.65     6.0.196.0   Oper-Up
2     2           192.167.10.12    172.19.47.66     6.0.196.0   Oper-Up
 
However, I can not ping the managment interface of the down controller while the other controller management interface is pingable. All these interfaces are in the same VLAN.
 
ping 172.19.47.65  
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to 172.19.47.65, timeout is 2 seconds:
.....
Success rate is 0 percent (0/5)

Problem is fixed when I reboot the problematic Controller. However, this problem re-appears after some time. I am not able to figure out why controller is not able to ping its default-gateway which is an SVI interface on Supervisory card on the same chassis, and showing status UP/UP. Is it a software bug or backplane fault or any other reason ?

View 1 Replies View Related

Cisco Wireless :: 6509 - WISM Not Connecting After Reboot

Apr 7, 2013

We have a WISM in a 6509. The 6509 lost power (the UPS failed) and upon reboot the WISM isn't allowing AP's to connect. The WISM is blade 4. Upon consoling in, I get this error message for all 8 ports: 42w6d: %EC-SP-5-CANNOT_BUNDLE2: Gi4/1 is not compatible with Po407 and will be suspended (trunk mode of Gi4/1 is dynamic, Po407 is trunk)

View 13 Replies View Related

Cisco Wireless :: 6509 - WiSM Version 6 Cannot Modify Service Interface

Jun 19, 2009

although cisco sw advisor said that the best IOS for my hardware 6509 Sup720 IOS: (s72033_rp-IPSERVICESK9_WAN-M), Version 12.2(18)SXF16   suits the WiSM; And I tested it already with WiSM version 5.0 but when I've upgraded the WiSM to version 6.0 the service interface from the switch side says:

B5_Noc2_CS1(config)#int gig 4/9
% This interface cannot be modified
 
as the customer refuse to upgrade the switch IOS & He wants to use the latest ED WiSM sw 6.0;

View 4 Replies View Related

Linksys Wireless Router :: WRT54GS Factory Defaults / Resetting Connection Type From PPPoE To Bridge

Jan 17, 2012

I'm having a very difficult time getting my WRT54GS to work with my Westell 6100 modem. I've been bouncing around gathering info, and what I've learned is that the goofy way CenturyLink tech support told me to hook up my old wired router (modem line into outgoing (LAN) router port) is because the Westell 6100 is a "smart modem/router". Therefore, when I run the Linksys setup CD, it sees the modem as a router, and won't properly configure. I've also learned that the Westell modem can be "dumbed down" into simply a modem by putting it into "bridge mode", which is where I'm at right now - trying to get it reset to factory defaults and resetting the connection type from PPPoE to Bridge. In the meantime, I also reset the WRT54GS to factory defaults, and now I've got another problem: the router will not allow me to set up encryption. The default setting is "Disabled", and when I click the down arrow and try to make any selection at all (preferred selection is WPA2 Personal), it reverts to Disabled. I've also tried to change the router's IP address to 192.168.2.1 (and alternately to 192.168.1.253), so it won't conflict with the modem's IP, and it freezes up every time I try.

View 2 Replies View Related

Cisco WAN :: Resetting 2811 To Factory Defaults

Apr 14, 2011

I have tried to reset a Cisco 2811 to factory defaults to no avail. The system is locked, meaning it's set to go immediately to username and password before doing anything else after boot up. I cannot get to ROMMON, nor can the CTRL-B break sequence allow me the option. THere is a "no-password recovery" option that apparently is set (or unset?) but I cannot work with that.
 
I am a newbie with the routers, but I have tried various CTRL-B breaks from bootup, to particular times through the boot up sequence.
 
I do NOT have "enable" (also known as "privileged EXEC") access on the router.  The router, when purchased, had a username and PW that is required to even get to the basic level 1 access. Without it the PW, I can't even get to exec mode.

View 5 Replies View Related

Resetting Modem / Router To Factory Settings

Oct 8, 2011

Got a Belkin wireless modem router some 18 monthes ago, and after a bit of a struggle managed to set it up. It worked fine, aside from the odd depower repower. For some reason, it just stopped working yesterday. I initially checked all my cabling etc and everything seems fine. I next tried resetting my modem/router to factory settings. When I tried to install the Belkin software I fell at the first hurdle with a message saying "The setup assistant is not able to connect to the router". After googling my issue, I followed others advice and running the cmd setting and typing in "ipconfig" only to find that my media state was disconnected.

View 2 Replies View Related

Cisco Switches :: Resetting SRW2008MP To Factory Defaults?

Jun 14, 2011

I have a Linksys SRW2008MP that I am trying to reset to factory defaults. The guy who set this up is no longer employed at my company, and I do not know the IP address to login with a web browser. The switch does not have a reset button on the back. I follow the instructions from Cisco's website, which include connecting a console cable and using HyperTerminal to login. I can connect to the switch and watch it boot up in HyperTerminal. However, when I get to the point of inputting user name and password (which should be 'admin' and '<blank>', I can't figure out how to make to terminal emulator accept the input (much like pressing the Enter button in a web browser). According to the pictures on Cisco's website, there should be an Action -> Edit -> Execute option down below the login, but I don't see it, so maybe the switch has to verify my credentials before I get to that prompt?
 
This is the first time in my life using HyperTerminal, and I think that's where my problem is. How do I get HyperTerminal to accept my input?
 
I have also tried using TeraTerm, a different console cable, and a different computer.

View 3 Replies View Related

Cisco Infrastructure :: Resetting 2431 IAD To Factory Settings?

Dec 10, 2012

I am at the rommon screen getting the > sign
 
Rommon 1>
 
When I am typing confreg 0x2142 I am just getting “rommon 2>” and if try again I will get “rommon 3 >”
 
No reset prompt , this never happened to me

View 1 Replies View Related

Cisco WAN :: 1841 Failed After Resetting To Factory Defaults

May 22, 2013

I have an 1841 (256M w/ crypto card) that stopped booting. I reset it to factory defaults as per Cisco's directions, then began to setup with Cisco Configuration Professional. On the next reload I get this: 

program load complete, entry point: 0x8000f000, size: 0xcb80
program load complete, entry point: 0x8000f000, size: 0xcb80
[code]...

The ios on the flash is "c1841-advsecurityk9-mz.124-22.T.bin"

View 4 Replies View Related

Cisco Switching/Routing :: Factory Resetting 1941 Router

Oct 27, 2011

What is the procedure to reset a 1941 router to factory defaults? I just recieved my1 1941 router. I connected it up to my Mac using USB. I got loged in using the cisco/cisco login and it said it will only work once and that I should create a new account.  So I entered the command as directed on the screen and it gave my an error about the command. I verified it three times and each time it rejected. While I was looking online for an answer the connection timed out and now I can't get back in.

View 1 Replies View Related

Linksys Wired Router :: Rv042 - Set Password Without Resetting To Factory Default?

Apr 3, 2012

Last year our Network Security Supervisor submit his resignation and unfortunately did not endorse us the admin password we already tried the password he suggested when we contacted him but nothing of them works. Is there anyway we can reset the password without resetting to factory default?

View 1 Replies View Related

Cisco :: 6509 - Unable To Tenet / SSH / HTTP To WISM

Feb 26, 2013

I have issue to access one of the wism on 6509 switch however other wism is ok both wism on switch are up and functional how to enable remote access on wism.

View 13 Replies View Related

Cisco Switching/Routing :: 6509 / WISM Requirements For VSS?

Feb 14, 2012

I have the following on my 6509:
 
Mod  Port Model              Serial #    Versions
---- ---- ------------------ ----------- -------------------------------------
  1   10  WS-SVC-WISM-1-K9   XXXXXXXXXXX Hw : 2.2
Fw : 12.2(14r)S5
Sw : 12.2(18)SXF16
Sw1: 8.6(0.306)R3V39
WS-SVC-WISM-1-K9-D XXXXXXXXXXXX Hw : 2.1
 
There are few documents that tell me different requirements for the WISM cards to configure VSS.

View 1 Replies View Related

Cisco :: After Upgrade WISM To 7.0.116.0 / Local Mode APs Will Not Download Image

May 25, 2011

I upgraded my WISM software to v. 7.0.116.0. The upgrade went smoothly. Most of my WAPs are H-REAP and they are working fine. I have a few local mode WAPs that are stuck in a downloading state. They will try to download, reboot, then try to download again. This is happening only with the WAPs in local mode. These WAPs were working before the upgrade.

View 2 Replies View Related

Cisco WAN :: Set Catalyst 4510R To Factory Defaults?

Aug 25, 2011

I'm part way through trying to set a Catalyst 4510R to factory defaults,  One thing I'm stumped on is how do i remove the Customer Disclaimer eg what commands do i need to remove this and any other customer text within the switch,  see below copy of text from the switch with customers details omitted. 
  
The ** computer systems and ** networks are only to be used in accordance with the** Electronic  ** Media Policy.  Please read

[Code]....

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst Express 500 Factory Reset

Sep 30, 2009

We have inherited a Catalyst Express 500 (model WS-CE500-24PC) from a company we aquired, and are having issues configuring the switch.
 
The switch must have been configured previously, but we don't know its IP address.  It is no longer on the network, so we can restart it as much as we need to.
 
We followed the factory reset process:
 
1)  Disconnect the switch from the power supply
2)  Reconnect the switch while holding the "SETUP" button
3)  Release the "SETUP" button when the status LEDs all turn Amber
4)  Wait for POST to complete
5)  Connect one PC to the port whose LED starts flashing
 
However, the PC is never given an IP address, and when we open a web browser, anything we try to browse to gives us "Page cannot be displayed", rather than the setup page for the switch.
 
Are there any known issues or browser/OS incompatibilities with this model of switch?  We're using Vista and Windows 7 with IE7, IE8 and Firefox 3.

View 9 Replies View Related

Cisco Switching/Routing :: Factory Reset Catalyst WS-C2960G-8TC-L Switch?

Feb 20, 2012

How do I do a factory reset on a Cisco Catalyst WS-C2960G-8TC-L switch?

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 3560 - Access Switch To Reset Password To Factory Defaults

Nov 5, 2012

Im trying to access the switch to reset the password to factory defaults (please see switch output Astrix has removed customer identifying information for security purposes.) Each time I reboot the switch and try and access the password recover mode this same output below starts and im still not able to access the recovery area of the switch
 
cisco WS-C3560G-48PS (PowerPC405) processor (revision F0) with 122880K/8184K bytes of memory.

Processor board ID FOC1133Y28Q
Last reset from power-on
1 Virtual Ethernet interface
52 Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.

[code]....

View 1 Replies View Related

Cisco Wireless :: Catalyst 3850 - CAPWAP Transit In MA / MC Mode?

Mar 10, 2013

I understand that Cisco *wants* the APs to be directly connected to the new 3850.I have a few questions.  Unfortunately, I think I know the answers.  I just want to confirm.
 
a.  When MA/MC is enabled on the 3850, does the 3850 start intercepting *all* CAPWAP packets it sees (much like CDP)?  Even non-Cisco CAPWAP packets?

b.  If I have a WLC 5500 upstream from the 3850, would APs hanging off a downstream 2960 be able to register to the 5500 through the 3850 when the 3850 is NOT in MA/MC mode?

c.  If I have a WLC 5500 upstream from the 3850, would APs hanging off a downstream 2960 be able to register to the 5500 through the 3850 when the 3850 IS in MA/MC mode?
 
What I'm afraid of is:
 
a.  yes, yes
b.  yes
c.  no   
 
From the Q&A page:Q. Does the Cisco Catalyst 3850 support indirectly connected access points?A. No. The Cisco Catalyst 3850 switch will always terminate the CAPWAP tunnel locally. Pass-through mode or indirectly connected access point is not supported at this time.

View 2 Replies View Related

Cisco WAN :: Catalyst 6509-E / Nat Overload Does Not Work

May 18, 2011

I have the folowing nat configuration on my catalyst 6509-E with a sup720-10G that does not work, and gives a erros messague:
 
ip vrf testes
rd 6900:5
interface Vlan1111
description liga
ip vrf forwarding testes
ip address 192.168.63.91 255.255.255.248
ip nat inside

[code]....
 
This configuration generates the folowing error:

NAT: translation failed (A), dropping packet s=128.2.21.21 d=192.168.63.185
 
If i change the nat overload to a static nat, everything? Is there any wrong with this configuration ?

View 1 Replies View Related

Cisco :: Time Synchronization Via NTP Between Catalyst 2960 And 6509?

Jul 1, 2012

I have a problem with the time synchronization via NTP between a Catalyst 2960 and Catalyst 6509. When I configure the 6509 switch as a NTP reference on the 2960, it does not synchronize with the 6509's NTP server. There is no reachability or ACL-related issue between both switches.
 
As soon as I configure a second Catalyst 6509 (which is completely identical to the other 6509 and in the same subnet) as a NTP server for the 2960, the time sync with the second 6509 happens immediality.
 
The first 6509 switch works as a NTP reference for at least 50 other switches and routers in the network - so why not for this one more switch? I checked some "debug ntp packet" and "debug ntp events" outputs and can clearly watch the NTP requests going out of the 2960, but on the 6509 just nothing happens - no debug outputs for this specific 2960, while requests from other devices come in all the time.
 
Maybe you have already experienced this strange behaviour in the past or got some deeper knowledge in the Cisco NTP server implementation. I could think of some sort of "maximum client limit" in the IOS NTP server, but could not find any mechanism like this in the standard NTP specification. Eventually, you can approve that this is a IOS-specific issue.

View 13 Replies View Related

Cisco Infrastructure :: Configure On Catalyst 6509 Two VACL

Feb 10, 2013

I need to configure on a cisco catalyst 6509 two VACL. On cisco 6509 there are already two SPAN ports configured, there are problems configuring other two VACL?
 
These VACLs send traffic to a Traffic Analyzer (SIEM), there are particular configurations to facilitate the operation?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6509 Interface Alarm?

Jul 10, 2012

I am getting alarms on Solarwind indicating interface down on  "GigabitEthernet 4/7 - Gi4/d1" and "GigabitEthernet 4/8 - Gi4/d2" from our core switch 6509.Remote login to the switch does not show the interfaces when I do the "sh run" command. Now I am at site trying to identify and diagnose this fault.Looking at the numbering on the switch, it indicates to me the card where these alarms come from is from the 'intrusion dectection module'

how I may login and identify this interfaces and rectify these alarms.

View 4 Replies View Related

Cisco Application Networking :: Catalyst 6509 - ASN Traffic Ace10 Module

Aug 26, 2012

I trying configure ASN traffic load balance, but doesn't works.I have one Cisco Catalyst 6509 and onde Cisco Ace10 module, in my context "PanWEB" i have the interfaces above: [code] If i try to establish a telnet session(telnet 10.96.202.10 80) i see the SYN packet passing through the ACE and going to the real server, but, the server do not response the SYN packet. I done a capture in the server using wireshark and could see that the IP address of the destination is the VIP and not the rserver ip address , this is a problem? Why can not I have the SYN + ACK from the server?

View 5 Replies View Related

Cisco Switching/Routing :: Traffic Flow Catalyst 6509 With WS-X6548-GE-TX

Nov 21, 2011

I'm receiving multicast traffic (400Mbps) on port 9/38 and sending it out on port gi9/48. I'm trying to achieve that traffic will stay within the card without using the switchfabric, 

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 6509 - Ether Channel Configuration?

Dec 1, 2011

I came across a Catalyst 6509 switch configuration and have noticed some strange thing on the ether channel configuration side, it appears that it have interface port-channel 2 and port-channel 2A, what was that mean? its the ether channel not forming and joined together?
 
What wrong with the below configuration that cause it to automatic created another port-channel (2A) interface in this case?

[code]...

View 3 Replies View Related

Cisco WAN :: VS Based 720 Supervisor As Minimum To Support Full BGP On Catalyst 6509-E

Nov 18, 2011

I'm currently in the process of evaluating potential equipment options for a Core Router/Switch that will be running BGP with several Tier 1 ISP's, the table download from each ISP will be full (300,000+ Routes). I was looking at a 6509-E with dual SUP720-3BXL supervisors but after reading the below link I'm a little concerned by the maximum routes table: [URL]
 
Do I have to go to the VS based 720 supervisor as a minimum to support full BGP on a 6509-E? Does any experience of the above switch + supervisor combination under a full BGP table, how well does it work? I'm looking at long term using this as a consolidated core (i.e. a VRF for the Global Internet routing table + a VRF for internal data center traffic, plus maybe some more shared VRF's).
 
Would I be better keeping a Core switch by itself and just buying edge routers to run BGP?

View 2 Replies View Related

Cisco Application :: 6509 - ACE Module In Bridge Mode?

May 16, 2011

We have a 6509 with an ACE module. For reasons I don't fully understand the ACE is running using a BVI in bridge mode. It has loads of secondary interfaces.

[Code]...

I can ping all of the IPs on the BVI, but only servers in Subnet 10.7.42/42 can ping out of the the layer 3 on the 6509. I have all the routes configured properly on the 6509 pointing to the ACE for these subnets. The question is though the config has been excepted, is there a limit to the number of secondary on a BVI. 

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved