Cisco Application :: ANM 4.3 With CSS11506 Monitoring Setup
Sep 28, 2011
I have installed anm 4.3 and is trying to setup monitoring my css11506. I have added the device and on the monitoring-setting-polling status, said the polling configuration is enabled, but the polling status time out.
The css11506 snmp configure as:
snmp trap-type enterprise
snmp cmmunity xxxxx read-only
snmp name "anm v4.3"
[code]...
can I limited the VIP? I really do not think the system is heavily used. could any configuration wrong cause problem could be possible the module has problem? if so, how can I confirm? could I add another SAM module?
Currently using a CSS1506 for our reverse proxy SSL.I have a couple of questions
1 - Does the 11506 use an internal disk as well as the one in slot 0 ? 2 - I have a spare mem card in slot1, how can I copy all of the required boot files etc to slot 1 in case of a card failure in slot 0?
I am planning to perform a failover drill between active and standy CSS loadbalancers which are configured in a cluster pair. I am looking for help to know what show commands I can run to validate that the failover occurred successfully from primary to secondary load balancer and that the VIP's have failed over successfuly as well.
How to confirm the PAT limit on the ACE-20s. I initially read it as 1 million (the NAT limit), however I have since read that for PAT, its 4 million as it uses the connection record information and not xlate.
I've always wondered why the xlate line under 'show resource usage' is zero. If PAT does use the connection record then this would explain why, however its confusing as when running a 'show xlate' command you do see all the current PAT entries.
We are currently running a ACE20 with 11 contexts. Recently we have seen that one of the contexts is being 'starved' of resources, especially Concurrent Connections, Bandwidth and Throughput.
Whilst we know how to address this situation by reallocating resources from less busy contexts, I was wondering if there was a more scientific way of looking at the resources being used and calculating the best way to allocate them across the ACE other than just looking at the 'show resource usage' and 'show resource allocated' commands?
Has Cisco or any other 3rd party developed a handy tool to monitor the the ACE resources which will possibly assist with calculating the optimum resource allocations across all contexts?
I have been given a task to create 2 checks using snmp for nagios. I am googling left right and center to maybe try and find the appropriate OID's that i can pass to this nagios check for both ssl throughput as well as compression throughput.
I recently installed a Cisco ACE 4710 version A4(2.0) into our test network. Load balancing across a number of web servers appears to be working ok and serving pages to users. However, when i tried to check the real time stats via device manager (Monitor> virtual contexts> context > Real servers) a number of fields specifically "current connections", "total conns", "failed conns" etc were showing N/A. Do I need to enable this somehow i.e. polling, if so how?
Currently running an ACE 4710, which is handling all of our inbound SSL connections and then forwarding requests thru to backend web servers. This all works fine.
My question is this..Right now we are not load balancing any of the backen web servers. But I now have a requirement that should a web server crash or become unavailable I need to redirect that backend connection to another web server.
Scenario is more like I have 2 web servers both serving same content, but I want one server to take all the connections unless it fails, at that point have all the connections forwarded to 2nd server.Is there a way to setup the load balancing where the 1st server gets all the connections until a failure happens ?
I have a VIP, which is listening on port 8312 in ACE LB and NO probes attached to it. In this scenario how does the ACE module perform the health monitoring ?
I am trying to setup VPN monitoring for a srp527w Cisco.This is my first attempt at this so "easy to understand" instructions would be a great, i have done some searching and its difficult to decipher relevant and irrelevant information based on my limited exposure to this technology.
I have an exhibition next saturday on network monitoring and I was given ftp server monitoring project. I'm only allowed to used linux based OS for this project. Right now I have 3 notebook. 1 as a client, 1 as a router and another 1 is for monitoring. Right now, I only can make a connection between the client and monitor notebook by using Freebsd in the router. How to setup a ftp server and how to monitor it?
It seems that motion monitoring setup for 930L is not working correctly.I've setup the camera to ONLY monitor the half of the screen, but it is still monitoring the other half of the screen as well.I've setup the camera to FTP the messages when motion is detected, and it is uploading the images when the other half contains the motion.
I'm trying to setup a Application specific proxy. I have tried everything that I could find via Google search and nothing seems to work. All the proxy servers I have found seem to be centered around web browsers such as IE, and firefox.
I need to setup new ACE 4710 device , after referring to "Establishing a Console Connection on the ACE" i had managed to set up initial console connection. During installtion i had configured vlan (default vlan 1000) , interface ip adess& subnet mask.
Post initial config i understand i should be able to open' Device Manager GUI Login Window' but it is not opening.I also need inputs on setting 4710 for the telnet connection
I have setup load-balancing on an ACE 4710 for HTTP for Sharepoint 2010. The Server Admin says that the IIS server will recognize the right site by DNS name. Problem is I have no clue how to make sure the servers get the DNS name passed to them. They says this is for a multi-homing setup so that we can run multiple sites using the same VIP to the same Serverfarm. How do I do this? I keep getting the IIS splash page since the real server cannot determine the IIS site that I am supposed to access.
Im trying to make a ACE+caching setup work. Ace is running A5(1.2)Content types considered static (like images, stylesheets and javascripts) should be fetched from caches instead of servers.Content from the caches that can be compressed should be compressed by the ACE (stylesheets and javascripts).I am classifying traffic into * static, not compressable (content should be fetched from caches but is already compressed - this class will hold .jpg, .gif, .png, .ico and others - but for this experiment the class is defined with only (a never to be hit) content type .xico* static, compressable (content should be fetched from caches but can be compressed by the ACE - this class will hold .css and .js but for this experiment is defined only with (never to be hit) content types .xjs and .xcssother For statistics purpose I have included a catch all class for everything else (which shold be send to servers) - class-default is configured but will not be hit in this example because of the catch-all class I configured.Since both "STATIC" classes include only content types that has been renamed to content types not used in the real world, I will not expect any hits on those and since WWW.SITENAME.COM:80_STATIC_COMPRESSABLE is the only class configured for compression I expect that nothing will be compressed since there wil be no hits on this class.
This is how it looks in the configuration:
class-map type http loadbalance match-any WWW.SITENAME.COM:80_STATIC_NOT_COMPRESSABLE 10 match http url .*.xico class-map type http loadbalance match-any WWW.SITENAME.COM:80_STATIC_COMPRESSABLE 10 match http url .*.xjs 20 match http url .*.xcss class-map type http loadbalance match-any WWW.SITENAME.COM:80_DEFAULT 10 match http url .*
[code]....
Questions are: Why do I see things being compressed when there is only being accounted hits in a compression:off class ?Why does enabling compression in one class (never being hit) cause hits in other clases to be compressed ?
we would like to setup FTP server over CSS where our member sever use non-std-port to open both control/data channel (i.e. 6370 as ctrl and 6369 as data this case.) but seems we only get Passive mode FTP mode work only but not for Active mode FTP case for data channel establishement for server back to client..
# sh ver Version: sg0820501 (08.20.5.01) Flash (Locked): 08.10.1.06 Flash (Operational): 08.20.5.01 Type: PRIMARY Licensed Cmd Set(s): Standard Feature Set
Belkin Setup / Router monitor application has stopped working. A problem caused the program to stop working correctly. Windows will close the program and notify you if a solution is available.
ACE 4710 TACACS issues ,How to setup user with Admin context access permission. I have enable the TACACS and it can directly put me in Context mode not in Admin Context mode .
Everytime I make a config change to one of the contexts on our ACE20, I get this message: Config Application in Progress. This command is queued to the system
Report run via Individual Web server URL’sThe report takes less than 20 minutes (average 15 minutes) to fetch and return the data. This is observed 9 out of 10 times.Report run via ACE Load Balanced URLThe report keeps on running for more than 20 minutes and never completes. The front end keeps showing report is running.The data in general when tested directly by running queries against the database (bypassing the platform) completes in 15-18 minutesThe network connectivity for each and every ports involved (Loadbalancer/Servers) have been throulgly checked.
Licenses are activated on a total of 31 devices (nexus 5000 and 3000 series), data is being monitored, graphics are drawn. However under the Web user interface of DCNM, under Health, Virtual Port Channels (vPC) no data is shown. Performance, vPC is also empty. No vPC errors/notifications are displayed. The installed advanced-eval licenses should support all the bells and whistles (including vPC), but still- no monitoring is done about vPC-s. vPC-s are up and active. network is discovered and monitored via snmp v2c only. could this be limiting vPC discovery- needing snmpv3/ssh access?
Does any know why the ASA will monitor physical interfaces by default, but monitoring of logical interfaces is disabled by default? Or better yet, is anybody doing a monitor-interface for a subint without issue? I'd imagine it isn't enabled by default for a reason.
I have a question regarding netflow and NAT. I have read some documentation (on ASR1000) regarding monitoring NAT process on Cisco ASR1000 that can be done using netflow version 9 (the term was called netflow event logging a.k.a NEL). The problem is, I have not found the netflow collector that can do that. I have queried several software such as manage engine "Netflow Analyzer" and Lancope, but they said their software can not do that.
VPN Tunnels Monitoring on ASA5510 with IOS 7.0 (Monitoring through Nagios Server).I want to use Nagios to monitor each of the S2S Tunnels built on ASA 5510. I can use the icmp on Nagios by adding Nagios host in IPSEC network of each tunnel but in that case the change needs to be done at other end of Tunnel as well.
We have around 20 VPN tunnel via Cisco Router 2821 (Intranet) and around 30 VPN tunnel via Cisco ASA (Internet) with 3rd Parties/Vendors.I wanna know if there is any monitoring tools from Cisco or any others providers who can give me information/trend report about VPN tunnel Up/Down time, Volumns of Traffic, Protocols etc.