Cisco :: MIB For Monitoring Temperature On 800

Sep 17, 2012

if there is a MIB for monitoring temperature on a Cisco 800?

View 2 Replies


ADVERTISEMENT

Cisco WAN :: Monitoring Temperature On 1921 Router?

Feb 9, 2012

how do I monitor temperature of my 1921 router? Which commands do I need to put on router and which MIBs to use. I am using PRTG network monitor as a monitoring system.

View 10 Replies View Related

Server Room - Remote Monitoring Temperature?

Jun 8, 2012

Any temperature monitoring unit we can install in our server room that we can use to moniter the room temperature? We had a near catastrophe recently when the air conditioning unit failed to restart following a power outage.

View 3 Replies View Related

Cisco :: Is Temperature Monitoring Via Snmp Supported On 2801 Routers

Jun 19, 2012

Is temperature monitoring via snmp supported on Cisco 2801 routers? when i perform a snmpwalk i donot get the associated value for the oids.

View 2 Replies View Related

Cisco WAN :: 3945 Router CPU Temperature?

Nov 8, 2012

I am trying to find out what the 'normal' operating temperature of the CPU in a 3945 router is? We have just replaced some 2800 routers for 3945's and the NMS server initially complained about the new router CPU temperature being too high.  Compared to the 2800 the CPU temperature is much hotter - 50 degrees celcius as opposed to 20-smothing degrees.  I have searched but can't find what are considered 'normal'?
 
This is the output:
 
router#sho environment allSYSTEM POWER SUPPLY STATUS==========================Internal Power Supply 1 Type: DCInternal Power Supply 1 12V Output Status: Normal

[Code].....

View 3 Replies View Related

Temperature Monitor With Cmd Output?

Mar 15, 2011

I'm looking for temperature monitor (HDD, CPU) that can be run with parameters, and have cmd result output.I need some software to monitor temperature in Labtech software.

View 12 Replies View Related

Cisco WAN :: Why Getting Temperature Event In 3560 Switch

Mar 9, 2013

why getting temperature event in 3560 switch, and we checked the Network room Temp it's normal around (22).

View 8 Replies View Related

Cisco Wireless :: Internal Temperature WLC 2100?

Dec 17, 2009

The operating temperature for 2100 wireless lan controllers is up to a miximum of 40 degrees celsius according to the datasheet. We deployed some 2112 controllers all displaing a temperature above 50 degrees celsiun. This during normal operation and deployed proper enviromet (aroco ...)

View 2 Replies View Related

How To Protect HT-IP206 (IPCAM) At Low Temperature

May 10, 2012

We bought two packs of IPCAM online from a vendor named HooToo, who seems have different online sites for selling various surveillance cameras. What we purchased is a unit with model no. of HT-IP206, according to its advertisement it has a storage temperature as low as minus 10 degree, and adversely high up to 60degree. While on the other hand, it states that the operating temperature shall be strictly between zero and 55degree. What Im concerned is that what if temperature drops down to minus when a camera is fully operating? Shall extra heating system be needed while the real temperature fails to meet the above-said requirement?

View 4 Replies View Related

Cisco Switching/Routing :: C3560E Difference Between Two Temperature

Mar 17, 2013

What is the difference between Operating temperatue & storage temperature of switch C3560E ?

View 2 Replies View Related

Cisco :: 2960 - Unable To Find OID Of Temperature Monitor

Dec 21, 2011

I have load CISCO-ENVMON-MIB and initiate walk in it but unable to find OID of Cisco 2960 temperature monitor. I have search over net and found .1.3.6.1.4.1.9.9.13.1.3.1.3.1 for temperature but this OID is not responding in this mib.

View 2 Replies View Related

Cisco :: 3560 - Need SNMP OID Or Object Name To Monitor Temperature

Jul 28, 2011

i have 3560 switch located in warehouse environments . i need to monitor the temperate of this switch . i am looking for OID value  that serves this purpose .
 
kindly provide me how to look for all OID that give me real time  status for FAN .. CPU UTILIZATION ...TEMPERATURE ...OR ANY MAJOR EVENT THAT CAN DISRUPT MY PRODUCT IN .

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 7000 To Know Ambient Temperature

Nov 2, 2012

I need to know how is the ambient temperature for the Nexus 7000 switches to plan a new datacenter. In the datasheet I found the following information regarding this topic:"GR-63-CORE Network Equipment Building Standards (NEBS) specification published by Telcordia Technologies in Section 4.1.2". How are the specification for temperature in this standard?

View 1 Replies View Related

Cisco WAN :: 2801 Router Not Showing Temperature In Show Environment All

Jun 19, 2012

We have a Cisco 2801 router running IOS "c2801-spservicesk9-mz.151-4.M4.bin" which we upgraded from previous “c2801-spservicesk9-mz.124-3d.bin”.
 
Requirement.
 
We want to monitor the device temperature via snmp but unable to do because temperature ratings are not available on "show environment all" output like below.
 
Routeri# sh environment all   Fan  1 OK   Fan  2 OK   ILP  Power Supply - Absent   Fan Speed Setting: Normal
 
Where as on Cisco 2811/51 & Cisco 3825/45 we can get temperature ratings on "show env all" output.
 
As per link [URL] below commands are supported on Cisco 2800 series router.
 
Command options
• show environment all
• show environment fans
• show environment leds
• show environment power-supply
• show environment table
• show environment temperatures
• show environment voltages
 
I want to know whether this is Cisco 2801 platform limitations or something else. tried to find Cisco doc on this but no luck.

View 2 Replies View Related

Cisco Switching/Routing :: WS-C2960-24TC-L Display Temperature

May 19, 2013

I have an issue with one of our switches, switch model WS-C2960-24TC-L, i am not able to display switch temperature as below,
 
Switch#sh verCisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 15.0(2)SE2, RELEASE SOFTWARE (fc1)Technical Support: URL ) 1986-2013 by Cisco Systems, Inc.Compiled Tue 05-Feb-13 12:41 by prod_rel_team(code)

View 2 Replies View Related

Cisco :: Nexus 5000 SNMP Monitor For Temperature Status

Aug 15, 2012

May I know how to monitor temperature status of below device by SNMP.How to find the exact oid of those devices? I can only find the mib file of Nexus 5000 at url...Cisco Nexus 5010PCisco UCS 6120XP Cisco ASR 1002F

View 1 Replies View Related

Cisco Infrastructure :: 1841 / 2960 Switch - Temperature OID Needed

Jan 24, 2012

I need  the temperature oid  for cisco 1841  and 2960  switch.

View 1 Replies View Related

Linksys Wireless Router :: E4200 External HDD Temperature

Jul 11, 2011

I cant remember where I read it but when I noticed that my HDD was running hot even when it was meant to be idle, I read that the router causes the storage device to run at full spin regardless.
 
I was wondering, do we know if that issue is fixed with this latest firmware update (June 14th)? I've had it on for about 10minutes but I'm not sure how long it takes to get to the temp that it was running at before.

View 4 Replies View Related

Cisco Switching/Routing :: Inlet And Outlet Temperature Sensor In 6500

Mar 9, 2013

Below module showing inlet and outlet temperature N/o.How to find the issue related to sensor in the module or something else to troubleshoot in the module to find the issue.

View 5 Replies View Related

Cisco Infrastructure :: Temperature Status From 2960 Switch Using SNMP Not Working

Sep 18, 2012

WS-C2960G-24TC-L   12.2(25)SEE3            C2960-LANBASE-M
 
I would like to get the temperature status from this 2960 switch (and several other models. Normally this OID should be:.1.3.6.1.4.1.9.9.13.1.3.1.6 But it does not return anything.
 
The termperature status can be found from the command line by running:"sh env temp" This reports back ok, so I assume there is a temperate gauge in the switch.
 
This oid is part of the "CISCO-ENVMON-MIB" mib and accouding to the Cisco MIB selector it is supported on my switch and IOS - 12.2(25).
 
(Another thing I woudl like to monitor and should be supported is the fan status oid (.1.3.6.1.4.1.9.9.13.1.4.1.3). That doesn't return anything either.
 
What do I need to do to get the temperature environment status from SNMP query?

View 3 Replies View Related

Cisco Wireless :: 3500 - Any Door Access Point Which Can Operate In Very Low Temperature

Feb 23, 2011

Recently i have visit some site for survey of wireless (WiFi). My client ask to provide the Access Point inside the Cold storage of factory( For RF scanners) The temperature of the place is -25 C to -30 C. I have go throug the wireless option of cisco like 1200 series, 1100 series, 3500 series, but all of these operate maximum of -20C. while only out door access point ( cisco 1500 Series ) support such low temparture.

View 13 Replies View Related

Cisco :: Catalyst 3560G Series Switch - Wrong Temperature Reading

Feb 26, 2012

I am trying to get the temperature reading from one of our 3560G Switches using SNMP. When I run an snmpget on the Switch it returns back to me a "1".
 
So when I run the following I get:
 
>  snmpget -v1 -c public 192.168.x.xxx 1.3.6.1.4.1.9.9.13.1.3.1.3.1005
SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1005 = Gauge32: 1
 
But when I telnet to the device and run a "show env temperature status" I get:
 
# show env temp status
Temperature Value: 32 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 51 Degree Celsius
Red Threshold    : 61 Degree Celsius
 
So I'm not sure why I am getting a "1" when using snmpget on the OID 1.3.6.1.4.1.9.9.13.1.3.1.3.1005 which is (ciscoEnvMonTemperatureStatusValue)??
 
If I run the same OID on another 3560G Router I get the correct output from snmp....

View 4 Replies View Related

Linksys Wireless Router :: E3000 - Temperature At Bottom Getting Very High

Jan 12, 2011

Yesterday I installed my new E3000 router. After an hour I noticed that de temperature of the bottom was very high and it stil is . Is that normal?

View 7 Replies View Related

Cisco Switching/Routing :: Industrial Ethernet 2000 Series Temperature Ranges

Jul 24, 2012

Any explanation regarding these different operating temperature ranges? I would think it doesn't matter the enclosure that the switch is in, it will either work or fail at a certain temperature.,-40C to +70C (Vented Enclosure Operating),-20C to +60C (Sealed Enclosure Operating), -34C to +75C (Fan or Blower equipped Enclosure Operating).

View 0 Replies View Related

Cisco Switching/Routing :: Nexus 5k Power Down Due To Temperature Sensor Policy Trigger

Dec 2, 2012

We have a nexus 5k, and it kind of got hung today... it is running. Version 5.1(3)N2(1b) the reset reason shows.Power down due to temperature sensor policy trigger.It doesn't look documented. What policy is it referring to? not sure if this is an IOS bug ?

View 1 Replies View Related

Cisco Switching/Routing :: Modules Operating Temperature And Major Error On 6509E Switch

Apr 6, 2013

we have two 6509E which are configured in VSS mode with the following modules in each:
 
  1   48  CEF720 48 port 10/100/1000mb Ethernet 
  2    8  DCEF2T 8 port 10GE                    
  3    4  CEF720 4 port 10-Gigabit Ethernet    
  5    5  Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G  
 
 I need to know if the temperature of the attached modules are normal or there is a problem?

the status of one of the supervisor engines is "MajFail" as shown below:
 
Mod  Online Diag Status
---- -------------------
  1  Pass
  2  Pass
  3  Pass
  5  Major Error

View 3 Replies View Related

Cisco Switching/Routing :: C4948E / C4948E-F (Chassis Temperature Sensor) OID Value

Nov 3, 2012

I want to know OID value for 'Chasis Temperature sensor' of C4948E.as below, I could find it for C4948 but couldn't C4948E and C4948E-F.

======================================== C4948-10G ======================================================
mrtg@WWW:~$ snmpwalk -v 2c -c public X.X.XX 1.3.6.1.2.1.47.1.1.1.1.2
SNMPv2-SMI::mib-2.47.1.1.1.1.2.1 = STRING: "Cisco Systems, Inc. WS-C4948-10GE 1 slot switch "
SNMPv2-SMI::mib-2.47.1.1.1.1.2.2 = STRING: "WS-C4948-10GE 1 slot switch chassis slot"
SNMPv2-SMI::mib-2.47.1.1.1.1.2.3 = STRING: "Chassis Temperature Sensor" 
SNMPv2-SMI::mib-2.47.1.1.1.1.2.4 = STRING: "Container of Fan Tray"
SNMPv2-SMI::mib-2.47.1.1.1.1.2.5 = STRING: "FanTray"

[code]...

View 3 Replies View Related

Cisco :: DCNM 6.2(1) Not Monitoring VPC-s

May 12, 2013

I have installed DCNM 6.2(1) on red hat 5.5 64bit and installed 4 evaluation (advanced) licenses on dcnm server:

DCNM-LAN-N3K-K9-EVAL
DCNM-LAN-N5K-K9-EVAL
DCNM-SAN-N5K-K9-EVAL
DCNM-SAN-M91-K9-EVAL
 
Licenses are activated on a total of 31 devices (nexus 5000 and 3000 series), data is being monitored, graphics are drawn. However under the Web user interface of DCNM, under Health, Virtual Port Channels (vPC) no data is shown. Performance, vPC is also empty. No vPC errors/notifications are displayed. The installed advanced-eval licenses should support all the bells and whistles (including vPC), but still- no monitoring is done about vPC-s. vPC-s are up and active. network is discovered and monitored via snmp v2c only. could this be limiting vPC discovery- needing snmpv3/ssh access?

View 1 Replies View Related

Cisco :: VPN Tunnel Monitoring In LMS 4.0

Apr 11, 2011

is there a way in LMS 4.0 to generate a notification when a VPN tunnel drops on an ASA 5500?

View 1 Replies View Related

Cisco :: Monitoring ASR 1002 With IOS-XE In IPM 4.2

Oct 26, 2011

We are running LMS 3.2 with IPM 4.2 installed....and we are looking to do IPSLA monitoring on a couple of our Cisco ASR's with IOS-XE code installed.
 
I looked at the IPSLA feature mapping and it only talks about supported IOS code....do we need to upgrade our current IPM module to a current version?

View 0 Replies View Related

Cisco :: ASA Monitoring Logical Interfaces

May 12, 2011

Does any know why the ASA will monitor physical interfaces by default, but monitoring of logical interfaces is disabled by default? Or better yet, is anybody doing a monitor-interface for a subint without issue? I'd imagine it isn't enabled by default for a reason.

View 2 Replies View Related

Cisco :: ASR1000 Monitoring NAT Using Netflow 9

Feb 7, 2010

I have a question regarding netflow and NAT. I have read some documentation (on ASR1000) regarding monitoring NAT process on Cisco ASR1000 that can be done using netflow version 9 (the term was called netflow event logging a.k.a NEL). The problem is, I have not found the netflow collector that can do that. I have queried several software such as manage engine "Netflow Analyzer" and Lancope, but they said their software can not do that.

View 11 Replies View Related

Cisco :: Srp527 Vpn Monitoring Setup

Feb 9, 2012

I am trying to setup VPN monitoring for a srp527w Cisco.This is  my first attempt at this so "easy to understand" instructions would be a  great, i have done some searching and its difficult to decipher  relevant and irrelevant information based on my limited exposure to this  technology.

View 1 Replies View Related