Cisco Switching/Routing :: C4948E / C4948E-F (Chassis Temperature Sensor) OID Value
Nov 3, 2012
I want to know OID value for 'Chasis Temperature sensor' of C4948E.as below, I could find it for C4948 but couldn't C4948E and C4948E-F.
======================================== C4948-10G ======================================================
mrtg@WWW:~$ snmpwalk -v 2c -c public X.X.XX 1.3.6.1.2.1.47.1.1.1.1.2
SNMPv2-SMI::mib-2.47.1.1.1.1.2.1 = STRING: "Cisco Systems, Inc. WS-C4948-10GE 1 slot switch "
SNMPv2-SMI::mib-2.47.1.1.1.1.2.2 = STRING: "WS-C4948-10GE 1 slot switch chassis slot"
SNMPv2-SMI::mib-2.47.1.1.1.1.2.3 = STRING: "Chassis Temperature Sensor"
SNMPv2-SMI::mib-2.47.1.1.1.1.2.4 = STRING: "Container of Fan Tray"
SNMPv2-SMI::mib-2.47.1.1.1.1.2.5 = STRING: "FanTray"
[code]...
View 3 Replies
ADVERTISEMENT
Mar 7, 2012
recently we purchased cisco smart care, and today i recived this notification: Configuration RegisterCriticalNot fixed on switch it is set to: Configuration register is 0x2101
what is recomended conf reg for this switch?
View 1 Replies
View Related
Mar 9, 2013
Below module showing inlet and outlet temperature N/o.How to find the issue related to sensor in the module or something else to troubleshoot in the module to find the issue.
View 5 Replies
View Related
Dec 2, 2012
We have a nexus 5k, and it kind of got hung today... it is running. Version 5.1(3)N2(1b) the reset reason shows.Power down due to temperature sensor policy trigger.It doesn't look documented. What policy is it referring to? not sure if this is an IOS bug ?
View 1 Replies
View Related
Dec 27, 2012
I'm experiencing considerable difficulties with CNA and my 4948E cat's. Front panel view, vLans and VTP utterly fail...and I have gone to GREAT lengths. I initially configured them all for comprehensive use in a vSphere environment. Storage switch fabric and multi-vlan guest networking. I wiped the config's across the board, factory reset all of them in an attampt to get CNA working. NO GO and it's been wildly frustrating, 80+ hrs spent with no results.
So is CNA truely compatible with the 4948e? And if so, WHAT IN THE **** AM I DOING WRONG!!?!?!?!!!!!?
Config and info:
C4948#show verCisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500e-ENTSERVICESK9-M), Version 15.1(1)SG2, RELEASE SOFTWARE (fc1)Technical Support: [URL] Copyright (c) 1986-2012 by Cisco Systems, Inc.Compiled Wed 24-Oct-12 02:27 by prod_rel_team
ROM: 12.2(44r)SG11C4948 uptime is 22 minutesSystem returned to ROM by reloadSystem image file is "bootflash:cat4500e-entservicesk9-mz.151-1.SG2.bin"Hobgoblin Revision 21, Fortooine Revision 1.40
Last reload reason: Reload command
[Code]...
View 11 Replies
View Related
May 27, 2013
We have a C4948E switch which is generating the following logs every ten minutes:
May 28 12:44:13 UTC: %SEC_LOGIN-4-LOGIN_FAILED: Login failed [user: Username: -40.0] [Source: 0.0.0.0] [localport: 0] [Reason: Login Authentication Failed] at 12:44:13 UTC Tue May 28 2013
May 28 12:44:59 UTC: %SEC_LOGIN-4-LOGIN_FAILED: Login failed [user: ] [Source: 0.0.0.0] [localport: 0] [Reason: Login Authentication Failed] at 12:44:59 UTC Tue May 28 2013
We have a terminal server (C2901) set up with reverse ssh to all the devices including the above C4948E. Can this be the one to initiate the logins?
The IOS of both devices is as below:
C4948E - cat4500e-entservicesk9-mz.151-1.SG.bin
C2901 - c2900-universalk9-mz.SPA.152-3.T.bin
I am unable to identify what is triggering the above logs to be created.
View 2 Replies
View Related
May 15, 2012
we need to install a line cards (WS-X4548-GB-RJ45, chassis WS-C4510R-E), on a chassis Ws-6504-E.where I can find information about compatibility?
View 2 Replies
View Related
May 13, 2013
I have 4507 switch and I got the error of fan sensor which is mention below [code] What the meaning of FAN Sensor both are Bad/off ?
View 4 Replies
View Related
Mar 17, 2013
What is the difference between Operating temperatue & storage temperature of switch C3560E ?
View 2 Replies
View Related
Nov 2, 2012
I need to know how is the ambient temperature for the Nexus 7000 switches to plan a new datacenter. In the datasheet I found the following information regarding this topic:"GR-63-CORE Network Equipment Building Standards (NEBS) specification published by Telcordia Technologies in Section 4.1.2". How are the specification for temperature in this standard?
View 1 Replies
View Related
May 19, 2013
I have an issue with one of our switches, switch model WS-C2960-24TC-L, i am not able to display switch temperature as below,
Switch#sh verCisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 15.0(2)SE2, RELEASE SOFTWARE (fc1)Technical Support: URL ) 1986-2013 by Cisco Systems, Inc.Compiled Tue 05-Feb-13 12:41 by prod_rel_team(code)
View 2 Replies
View Related
Jul 24, 2012
Any explanation regarding these different operating temperature ranges? I would think it doesn't matter the enclosure that the switch is in, it will either work or fail at a certain temperature.,-40C to +70C (Vented Enclosure Operating),-20C to +60C (Sealed Enclosure Operating), -34C to +75C (Fan or Blower equipped Enclosure Operating).
View 0 Replies
View Related
Apr 6, 2013
we have two 6509E which are configured in VSS mode with the following modules in each:
1 48 CEF720 48 port 10/100/1000mb Ethernet
2 8 DCEF2T 8 port 10GE
3 4 CEF720 4 port 10-Gigabit Ethernet
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G
I need to know if the temperature of the attached modules are normal or there is a problem?
the status of one of the supervisor engines is "MajFail" as shown below:
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Major Error
View 3 Replies
View Related
Dec 19, 2012
Currently have a pair of 6509 chassis setup with VSS. Only have the Sup and two line cards in each chassis. Would like to replace with a new pair of 6504E chassis. Is it possible to fail one chassis at a time and migrate to the new 6504E?
View 3 Replies
View Related
Aug 30, 2012
I have PAT set up successfully on 6506 chassis - My outside address range is 78.24.112.114 255.255.255.240.Relevant parts of the config below: [code] This works fine but of course is only using the one IP address 78.24.112.114.how I can utilize the other outside addresses available or is this not really necessary? I've browsed through loads of Cisco docs.
View 2 Replies
View Related
Feb 3, 2013
why is not possible to put a WS-X4712-SFP+E - module into an R-E chassis?The module has the same connection to backplane as the WS-X4748-UPOE+E and this one works in a R-E chassis.I know the restriction of Cisco that the 4712 is only supported in 4503-E, 4506-E,4507+E and 4510+E, but why?Are there hardware-restrictions, is the backplane different?
View 2 Replies
View Related
Aug 22, 2012
We are preparing to install a new switching Infrastructure at one of our sites. We have decided that we want to have two separate chassis as a core. My original idea was to purchase 2 - 4500 chassis and install 10Gb and 1GB line cards in each and use STP and HSRP to load balance between the two cores.
We had also contacted a vendor for thier recommendations and they came back with 2 6500 Chassis running VSS. I reviewed what VSS was as I had never heard of it and it looks to me basically to be real close to the same thing as Stacking. I didn't really want to have stacked Cores because I would like to have the flexibility to be able to take one core out and update the software or image, reboot, and such without effecting anything on the network. I can do that with the non-VSS approach but it looks like that would be more of a problem with VSS.
My question is, how to use VSS with the 6500's? How to take one of the VSS pairs off line and not effect normal network operations?
View 7 Replies
View Related
Jan 4, 2012
Configuring a 4507R classic chassis with redundant Sup 6L-E? TAC told me the Supervisor 6LE was only supported on the 4507R+E or 4507R-E chassis but I have found in Cisco documentation several places that indicate that the Sup 6LE is supported in the classic chassis.
View 1 Replies
View Related
Dec 31, 2011
Every one i want to know ws-c4503E series 3 -slot chassis . I have compatibility issues with MEM-C4K-FLD64M AND S45EIPBK9-12240SG will work.
View 2 Replies
View Related
Mar 9, 2013
We have a backup sup 720 which has a 2 gigabit ethernet though port channel, to another chassis. Suddenly UDLD detected an error and got into err disable, then this err disable didn't let the interface set to DOWN, and created a switch loop, then our Supervisor reloaded. I'd like to know what could have caused this reload. In my opinion could have a been the switch loop, but also I've been checking from the output interpreter the show tech and might have been a bug, the only one that could match in IOS version 12.2(33)SXH, is this one: url...
We're going to disable err-disable next time I guess and recover the link manually, apart from that what could have made the sup for crash and reload?
View 4 Replies
View Related
Sep 9, 2012
Can any share some useful links on how this works and how to configure it? Do you still need to configure FHRP or does configuring redundancy take care of active/standby relationship between the ASR's?
View 2 Replies
View Related
Oct 24, 2011
I have an alert from monitoring system about: “ fan for this system is not in the NORMAL state”. In the switch I found that the problem is with fex 3, see below:
Nexus5020# sh env fex 3 fan
Fan Fex: 3:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Chassis N2K-C2148-FAN -- failure
PS-1 N2K-PAC-200W -- OK
PS-2 N2K-PAC-200W -- OK
Technician said: fans appear to be operational, BUT the only thing that appears abnormal is STAT light is amber (not sure what it means).
Also, if I compare the temperature from module 3 with module 2 (which doesn’t have an alert) is almost the same, this is why I think the fan is working fine, since module 3 is not hotter that module 2.
What I can do to reset this fan (chassis)?
View 2 Replies
View Related
Jan 28, 2012
swapping out a failed supervisor card on a 6509 chassis?
View 6 Replies
View Related
Jul 8, 2012
I have 4x 3110x switches in a Bladecenter H chassis and the stack cables are connected so that they are in a circle (IE, SW1 connects to SW2, SW2 connects to SW3, SW3 to SW4 and SW4 to SW1). Each of the switches physical 10GE port is trunked to a 6509. If I pull a 3110x switch out, does this network connectivity? Theoretically it should not?
TK2EWRBC4SW01#sh switch neigh
Switch # Port 1 Port 2
-------- ------ ------
1 4 2
2 1 3
3 2 4
4 3 1
View 4 Replies
View Related
May 1, 2013
we have some pairs of 6509-VSS, which partially have old (no more officially supported) 6509-Chassis.All linecards in the VSS are the same (Sup 720-10GE-3C, 67XX).
We now bought some new 6509-E-Chassis and want to change the old chassis by the new ones in a ISSU manner, that means:
1. putting the partner, which chassis changes, in redundancy mode, switch it off, exchange chassis (old "Catalyst 6509", new "Catalyst 6509-E")
2. inserting the line-cards exactly in the same slots and connecting all cables
3. switch on the new chassis, witing to come up in VSS
I'm not sure of having to set the switch number for VSS (is that in the Sup?; configuration? or part of the chassis-memory?)
I've looked up cisco for some hints, but don't found anything.
View 5 Replies
View Related
Oct 18, 2012
Are there any physical characteristic differences between the 6509 and 6509-E chassis?
View 4 Replies
View Related
Dec 9, 2012
I have multiple 6509 vss switch. and i notice when the standby chassis reboot I didn't get any snmp trap, but I got when the active one reboot. my question is is there any mib out there for detecting and got a trap when standby reboot?
View 2 Replies
View Related
Jan 8, 2012
Client has Cisco 4507R+E chasis with SUP- 7L-E and he has WS-X4418-GB line card in stock can this line card work with E series chassis
View 2 Replies
View Related
Nov 29, 2010
I have a heck of a time finding this kind of information on the cisco site...Is the WS-SUP720-BASE line card a fully supported module in the 6509-E chassis?
View 4 Replies
View Related
May 24, 2012
I need to configure a 4507 chassis with two SUP 7 installed. I havenot done SUP redundancy comnfiguration and i was owndering
View 9 Replies
View Related
Sep 25, 2012
Any have experience on triggered failover on VSS deployment with 1 VS-720-10G-3C in each chassis? I tried using "redundancy force-switchover" but after that the 20G VSL is flapping up & down and cannot be up normally, we got 1 FWSM in each chassis, any configuration need to fit in this kind deployment? BTW, if I shutdown the power source of VSS active chassis, both FWSM & VSS can failover normally.
View 3 Replies
View Related
May 1, 2012
I'm seeing several error messages like these in the logs of my Nexus 5548UP switches.
2012 Apr 24 16:39:41.470 SSV_5K_SW2 %LLDP-5-SERVER_ADDED: Server with Chassis ID aaaa.bbbb.cccc Port ID mgmt0 management address X.X.X.X discovered on local port mgmt0 in vlan 0 with enabled capability Bridge
2012 May 2 05:05:00.627 COR_CCO-NX-5548-UP_01 %LLDP-5-SERVER_REMOVED: Server with Chassis ID aaaa.bbbb.cccd Port ID aaaa.bbbb.cccc on local port Eth1/1 has been removed
2012 May 2 05:06:40.328 COR_CCO-NX-5548-UP_01 %LLDP-5-SERVER_ADDED: Server with Chassis ID aaaa.bbbb.cccd Port ID aaaa/bbbb.cccc management address NIL discovered on local port Eth1/1 in vlan 0 with enabled capability None
I will say that these 5548s are serving as the distribution layer for a UCS chassis (2x 6120 FIs) but didn't know what kind of visibility the Nexus would have into that - the chassis keyword is what's alluding to this in my mind, and I'm seeing these messages whenever interfaces that connect downstream to the fabric interconnects are brought up or down.
View 2 Replies
View Related
May 27, 2012
We currently have a WS-C6506 chassis with a line-card WS-X6408A-GBIC. Currently we need to replace the chassis by a Ws-6504-E and also the line-card. My question is: What must buy line-card and meets the same specifications of WS-X6408A-GBIC?.
View 4 Replies
View Related