On my 6509-E, all the modules show this:
Region F1: INVALID
Region F2: INVALID
Currently running ROMMON from S (Gold) region
Is this alright? Is the Gold region like a default region where ROMMON is always installed. And are F1 and F2 just storage partitions that are available to hold backup copies of the ROMMON? From what I read, it sounds like I can copy ROMMON images to F1 and F2, either the same version as the Gold region or different versions. Is that correct? Why would I want to copy different ROMMON versions to F1 and F2?
View 3 Replies
ADVERTISEMENT
Feb 22, 2012
I had a sw/reset on my 6509 switch. The info in the crashinfo file pointed me to bug CSCso89550.
The workaround for this issue is to disable the gold diagnostics tool.
View 1 Replies
View Related
Jul 26, 2012
I have always done my port monitoring (SPAN) on Cisco layer 3 switches with no issues. This time I am trying to do this on a Cisco 2901 router:
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.1(4)M2, RELEASE SOFTWARE (fc1)
System image file is "flash0:c2900-universalk9-mz.SPA.151-4.M2.bin
I need to have the source port gig0/0 and destination port gig0/1. There is something about the gig port enumeration (slot/port#) that makes the command rejected. It is self explanatory:
#sh ip int brie
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 xxx.xxx.xxx.xxx YES NVRAM up up
GigabitEthernet0/1 unassigned YES NVRAM up up
Serial0/0/0:0 unassigned YES unset up up
[code]....
It doesn't matter what slot or port number I use, it is always rejected. The command is rejected for Both destination and source gig interfaces. I tried a wide variety of slot/port numbers. To my best understanding the complete port names are: GigabitEthernet0/0 and GigabitEthernet0/1, so why does it think there has to be another digit after 0/0 or 0/1? Does it have anything to do with the Embedded-Service-Engine0/0 being administratively down?
View 4 Replies
View Related
Apr 30, 2012
I have a new 6509E with 2 sup 2T cards. The 10GE ports on both sup cards will connect to 2 5548s. Can i connect the management interface on the new 6509E to the old 6509 until i free up space to bring the line cards over?
View 2 Replies
View Related
Dec 9, 2012
I have a couple of 6509-E combined in a VSS system. I need to upgrade them to support 8 (or 16 at max) 10G uplinks. I already used the two built-in VS-S720-10G fiber connectors for VSL links. Which Ethernet modules do you suggest to use? are there any related upgrades that I have to do?
supervisor used: VS-S720-10G
Chassis: WS-C6509-E
View 2 Replies
View Related
Aug 7, 2012
I want to migrate a Cat 6503-E VSS to Cat 6509E VSS. We plan to use the same supervisor that we have on the Cat6503E, for minimizing the configuration change on the Doing this, the vss link will need to be changed, due to the fact that the supervisor slot will change with the Cat 6509, slot 5 instead of 1.
Question: is there a way to just change the vsl-link interface on a existing VSS ?
View 3 Replies
View Related
Oct 1, 2012
I have a pair of Core VSS 6509E SUP 2T. Two different LANs, two diff. Subnets. larger LAN has been connected to the VSS pair usng normal SVI and Post-Channles (has lots of closets 3750 stacks) and no problem. Second LAN, two closets, stacked and connected to each other via Port channel and trunk + SVI interfaces. Now, I have SVI interfaces for both LANs on teh VSS pair and that is causing traffic from one LAN to jump over to the other VLAN and rightly so because the VSS pair see both subnets as directly connected subnets. I was wondring if I delete the SVI for the second LAN and only keep the L2 VLAN this will be resolved> The reason for the second LAN to connect to the VSs pair is only that It has to go through the VSS pair to get to the WAN router (both LANs will go out through this Same WAN router) but WAN router is not my concern at this time. I need to isolate these two LANs/subnets traffic so no one VLAM traffic jumps over the other.I have also thought about VRF but at this point I am not sure if teh 3750 stacks supports VRF and if it does how to implement VRF on the second and samller LAN to just allow it go through the VSS pair in order to get to the WAn router.
View 13 Replies
View Related
Oct 27, 2011
I have a 6509E switch with dual 6Kw power supply that is logging "Power supply 1 input has changed. Power capacity adjusted to 2671.20W" then will bounce back to normal at random times from 1sec to 10sec. Is there a command to check what each input level of the power supply to try to identify possibly which source is causing the problem? The power supply input lights remains green while this is occuring.
View 3 Replies
View Related
Feb 27, 2013
Trying to find documentation on the proper procedure for installing a second sup720 into our 6509-E chassis for sup redundancy. I have found documents that tout how 'cool' and 'awesome' NSF/SSO, and all that is, but haven't found any docs on installing a second sup720 into a chassis that is currently in production and is only running one sup720. In all the years that this chassis has been out, there must me a documented procedure out here to explain this.I have been through the following pages, and have found nothing to this effect.
View 1 Replies
View Related
Jul 2, 2012
upgrade experience with the 6509E on what IOS version to use. This is a new install, so I want the most current version that supports SSH and works with dual supervisors.
Here is some information:
WS-C5609-E with 983008K/65536K bytes of memory
Current version 12.2(18)SXF17b
Slot 5 Supervisor 720 (Active)
Slot 6 Supervisor 720 (Hot)
Just need a strong base code, no advanced services. Let me know if you any additional information.
View 2 Replies
View Related
Dec 29, 2011
Looking at the specs for WS-X6704-10GE, it shows the port buffers at 16M per port. This doesn't seem like very much for a 10G port. Is this upgradable or related to how much RAM is in the blade?
View 4 Replies
View Related
Feb 6, 2012
We are experiencing with high CPU input due to ARP input between 20:30 and 22:30 every day At this time we have a lot of backup operations. When I look the netflow report, I can't see anything anormal.
We are changing our backup server's NIC card from 1gig to 10Gig. The backup operation's traffic is high (approx 2Gbps level) but 6509 has to be handle this size of traffic.
We are using two 6509E in VSS mode and our image version is s72033-adventerprisek9_wan-mz.122-33.SXJ.bin
20:00
show ip arp summary
--------------
2588 IP ARP entries, with 166 of them incomplete
[Code].....
View 16 Replies
View Related
Nov 7, 2012
I have to upgrade two Cisco Catalyst 6509E from Catos to IOS. I would want to know the requirements hardware or software for upgrading. Which are the recommended images I must download? From cat6000-sup32pfc3k9.8-4-5 to the latest stable version of IOS, is it recomended to pass to another previously version before?
I have viewed the following links,[URL]but, it doesn`t mention anything about that. The image below is the result of the "show version" command of one of our Cisco Catalyst.
WS-C6509-E Software, Version NmpSW: 8.4(5)
Copyright (c) 1995-2005 by Cisco Systems
NMP S/W compiled on Aug 3 2005, 13:13:36
[code]....
View 2 Replies
View Related
Nov 2, 2011
we are seeing network latency problems and our cpu on the 6509e is spiking and have a above average % for the past week or so. When we do see these spikes it seems that snmp and apr input is high
CPU utilization for five seconds: 75%/53%; one minute: 17%; five minutes: 14%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 9 1636168 95505 17131 4.19% 0.36% 0.34% 0 Check heaps =======>
12 478096 1011864 472 3.07% 0.12% 0.12% 0 ARP Input =====> 52 30420 436000 69 0.07% 0.07% 0.07% 0 Per-Second Jobs
53 317496 7789 40762 0.87% 0.10% 0.06% 0 Per-minute Jobs
220 55380 87807 630 0.07% 0.06% 0.07% 0 Compute load avg
[code]....
we recently upgraded our 3560 switches to the new 12.2-55 ios version but have not upgraded our 6509 because its ios is on 12.2(33)SXJ1. Not sure if this is related or not but it seems that after we upgraded to the later ios that the latency started.over the last 24 hours the spike is several times an hour and at least one a day that it hits the 90 - 100 % mark.is there a way that we can limit what snmp view but would not effect functionality or network?
View 2 Replies
View Related
Oct 18, 2012
Are there any physical characteristic differences between the 6509 and 6509-E chassis?
View 4 Replies
View Related
May 22, 2012
What is the cause of having a huge number ( 875349) of total output drops on one of my gigabit utp port gi 2/12 which is connected to Cisco 1841 fa0/0 router by mean of cat5e cable.I did change the cable from cat5e to cat 6 and tried to increase hold queue to 4096 and to tweak wrr queue bandwidth
View 4 Replies
View Related
Sep 11, 2012
I have two Core 6509E SUP2T configued as VSS and has two 48 ports fiber blades. I have two 3750s, I have two gig on each 3750 port-channle to po1 and connected to both the core, one link to each core.Now, I was asked ot add two more links on each 3750 switch to make it a total of 4 gigs on each 3750s (all 4 gig ports/uplinks will be in used an dtwo links to core one an dtwo links to core 2).when i added two additional links on 3750s and bundled them to po1, I created another port channel on core and bundeled the additional two gigs on each core to accomodate for the two additional links (ports on core switches are not consequtives).
adding these two additional ports makes the 3750 switches flap between managemnet vlan and po1.now, i am not sure if I must have added the two additional links on the core to teh current port-channel or core!? I have created another port-channel on core to accomodate for this currently!?
View 26 Replies
View Related
Apr 3, 2013
we have two 6509E, as our core switches. Recently I noticed that on some connections I have a high output queue drop rate.
These 4 x 2 interfaces (gigabit) are connected to our blade encolure, consisting of 4 x WS-CBS3120X-S. The utilization of the links is really quite low, when I see the increase of the drops. (~=60Mbps). All the links are fiber (SFP) and the distance between the core switches and the enclosure is about 15-20m.
I am not aware of any service degradation on the part of the servers. No CRCs, collisions etc, on the interfaces, apart from the drops.
The line card is a WS-X6748-SFP, but other interfaces don't seem to be experiencing any problems.
View 2 Replies
View Related
Oct 21, 2012
I have Catalyst 6509 E with redudant SUP720-3B (and MSFC3) running 12.2(18)SXF6 IP Services Lan Only IOS (this IOS requires 512MB DRAM and 64MB of flash) SUP has 512MB DRAM (458720K/65536K) and 512MB sup-bootdisk:, but, there is65536K bytes of Flash internal SIMM (Sector size 512K).
My question is can I put 12.2(33)SXJ3 IP Services Lan Only IOS to this 6500 because this IOS requires 512MB DRAM and 512MB od flash?This is "sh ver" and "dir all-filesystems" of my 6500:
cat6500#sh verCisco Internetwork Operating System Software IOS (tm) s72033_rp Software (s72033_rp-IPSERVICESK9-M), Version 12.2(18)SXF6, RELEASE SOFTWARE (fc1)Technical Support: [URL] Copyright (c) 1986-2006 by cisco Systems, Inc.Compiled Mon 18-Sep-06 23:59 by tinhuangImage text-base: 0x40101040, data-base: 0x42D90000
ROM: System Bo
View 6 Replies
View Related
Nov 29, 2012
I have a Cat6506. There were 2 Sup 720 in it for redundancy. They told me they had problems with this thing in the past needing to go out and reboot the machine. I need to go out periodically because it goes into ROMMON. I type boot and it comes back up. One time though neither one would reboot. I had to take a third one out there and reconfigure it. Now it is starting to do the same thing. One thing I did notice is they never connected it to an UPS. It is plugged strait into the wall with power going to two outlets. I am beginning to think there are spikes in the power occurring and this is sending it into ROMMON.
View 6 Replies
View Related
Sep 2, 2010
I upgraded four 3560E, 12.2(44) to 12.2(55)SEThree 3560 works fine, the last one stops after 17-18 seconds with a solid green LED. I cant get into ROMmon, the switch doesn't boot up. its like "dead but still alive"
My TS:
1: Removed all SFPs.
2: Reset PSU and fan modules.
3: Replace PSU and fan modules.
4: Try to get into ROMmon.(pushing mode button and break seq.)
Startup LED:0-1 seconds: SYST: Amber RPS: Amber STAT: Green DUPLEX: Green SPEED: Green
1-17 seconds SYST: Blinking Green RPS: OFF STAT: OFF DUPLEX: OFF SPEED: OFF
18 s--> (only testet up to one hour) SYST: Solid Green RPS: OFF STAT: OFF DUPLEX: OFF SPEED: OFF
A working 3560EStartup LED information. If I compare a working switch with the faulty switch I can see about 18 seconds into bootingSYST change very fast from green to amber and continues with booting,this doesnt happened on the faulty switch (solid green 18 seconds). Pushing MODE button, doesn't get me in to ROMmon, this works for all the other switches.On a normal 3560 it takes around 40 seconds before I get in to ROMmon. With this faulty switch it stops after 18 seconds(solid green) and it doesnt respond.
View 7 Replies
View Related
Jun 4, 2012
Could not find a valid file in BOOT environment variable. BOOT variable can be set from IOS. To find currently setRom Monitor variables, type 'set' command.
Choosing a boot method, type 'confreg' command.rommon 1
>setPS1=rommon ! >RommonVer=15.0(1r)SG5SupportedFeatures=1ConsecPostPassedCnt=2DiagMonitorAction=NormalCONFIG_FILE=bootflash:cat4500e-
[Code].....
View 11 Replies
View Related
Mar 3, 2013
configuring EtherChannel between 3750-X cross-stack and 6509E switch. I use two ports on 3750s, and two ports on 6509. I just need it as a trunk. For some elusive reason one port on 3750 keeps being err-disabled, and one on 6509 notconnected.
Here is what I did so far.
3750
!
interface GigabitEthernet1/0/22
description ***VSS-RNOC-link***
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 2
[code]....
Problem with :
GigabitEthernet1/0/22 is down, line protocol is down (err-disabled)
GigabitEthernet2/1/29 is down, line protocol is down (notconnect)
I tried shutting them down, then no shutting them again. Didn't work.
View 11 Replies
View Related
Apr 6, 2013
we have two 6509E which are configured in VSS mode with the following modules in each:
1 48 CEF720 48 port 10/100/1000mb Ethernet
2 8 DCEF2T 8 port 10GE
3 4 CEF720 4 port 10-Gigabit Ethernet
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G
I need to know if the temperature of the attached modules are normal or there is a problem?
the status of one of the supervisor engines is "MajFail" as shown below:
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Major Error
View 3 Replies
View Related
Jun 11, 2012
I have an issue that I am trying to track down. When I have 2 servers on the same VLAN on my AS pair, all is good because nothing leaves the switch. Where the issue is, is when I have 2 servers on different VLAN's and it requires a hop across the Core router pair. This hop drops the throughput rate by about 20-25% (from 44M to 35-36M)I think I know the issue, but want some input to from other to make sure I am not off-base. I have a pair of 6509E chassis' running Sup720 (VS-S720-10G) with CEF720 (X6748-GE-TX) modules. This is my Access Pair running VSS to look as 1 switch.
These tie into the Core pair of 6500E chassis' running Sup720 (Sup720-3B). This issue I see is that the core has a CEF720 card (6724-SFP), but the AS pair does not connect to the core on that card, they connect on a RJ45 Ethermodule (6148A-GE-TX) card. Would the fact that the AS pair does not connect to the core on the CEF7220 module on the core, cause the traffic to not make use of the CEF features of the Core and make each packet then have to be processed by the core instead of Express Forwarded?
View 1 Replies
View Related
Oct 28, 2012
I have one Catalyst 6509E chassis and two SUP720. The bootup sequence on SUP 720 (standby hot) failed . Messages that appear on SUP 720, on the console port indicate o software crash. I don't have a flash card in SUP720.
This is the bootup process:
System Bootstrap, Version 8.5(3)
Copyright (c) 1994-2008 by cisco Systems, Inc.
Cat6k-Sup720/SP processor with 1048576 Kbytes of main memory
[code].....
View 1 Replies
View Related
Dec 10, 2011
I'm currently pursuing to take my CCNA and am currently studying for it, but have recently encountered a problem with one of my 1760 routers that I can not solve.Yesterday I went to boot up my router like normal, however when I went into hyperterminal I noticed the router was in Rommon mode. Thinking I could change the configuration registry, I tried to bypass the NVRAM by using confreg 0x2142. However this still causes the router to go into Rommon mode. I am getting an error that states that there is insufficient memory to load the IOS image. [code]
I have used the dir flash: command and can see the IOS image, and try to boot from it (boot flash:iosimagename) but it will still go back into rommon mode. I also just swapped the RAM from my other 1760 into this 1760 and it booted up and went into normal configuraiton mode without any issues. However, the other router now will not load it's IOS image and I get the exact same error.I'm at a loss here, and have searched to figure out where or how I can just wipe the router clean to try and start fresh, but cannot get out or Rommon mode. The only thing I can think of is that the RAM went bad since it wont boot up either machine.
View 1 Replies
View Related
Apr 11, 2013
I have an issue with a customers 6503 with Sup-2T cards, where we are locked out of the console due to an authentication configuration error. So tried several times to get the card into rommon, with no success.
Checking through the various documents on CCO I dont find any reference to rommon on this card, but do find information on using the CMP to support the supervisor. I logged into the CMP but couldn't find a way from there to do a password reccovery either.So, is the `normal' IOS rommon/password recovery method supported.
View 2 Replies
View Related
Jul 24, 2011
I am facing a problem with a cisco 6509 that goes into rommon every time i restart. If i give the command
rommon 1> boot
it will pick up the IOS on the sup-bootdisk: or bootdisk: and boots up but i dont understand why on reboot it wont pick up this IOS and boot itself and why do i have to write boot command everytime on rommon.
I have also explicitly given the command "boot system bootdisk:IOSNAME.bin" in the startup config file but still no luck.
View 36 Replies
View Related
Jul 3, 2012
An ASA 5505. Device boots to rommon #0> and stays there. The complete boot record follows:
CISCO SYSTEMS
Embedded BIOS Version 1.0(12)13 08/28/08 15:50:37.45
Low Memory: 632 KB
High Memory: 507 MB
[Code]....
View 15 Replies
View Related
Dec 16, 2012
I have 6509 E. Actually what happen it last 3-4 times it reload its self and got stuck in rommon mode, i tried to boot it with boot by connecting a console cable on supervisor 720 2b. What and where is problem and why is stuck in rommon after reload.
View 11 Replies
View Related
Dec 12, 2012
I tired to upgrade the flash memory on my 871. I have tired to send single break and removing the flash card to drop the 871 to rommon. but no luck, all i get is the below error. I have try restart button on the back and get the same results. How to get the router into rommon mode so i can place the IOS on the flash ?
View 5 Replies
View Related
May 9, 2012
i have a Cisco 6513 it is used one, i have tryed to boot it but it did not work, it alwayes go to rommon mode and i am not able to know what is the issue,
when it boot i get the below outpot from the switch.
System Bootstrap, Version 8.1(3)
Copyright (c) 1994-2004 by cisco Systems, Inc.
Testing lower main memory - data equals address
[Code].....
View 3 Replies