Cisco Switching/Routing :: SFP 10G-LR Module Data Sheet Shows Two Values For Transmit Power
Jun 2, 2013
I am using 10Gig link to connect distribution and access switches. Since we are terminating the cables at multiple locations, we are also doing the link budgeting. The CISCO SFP 10G-LR module data sheet shows two values for the transmit power one of which is maximum power .5dBm and another is minimum power -8.2 dBm. Which value should I choose for the link budgeting.
View 1 Replies
ADVERTISEMENT
Feb 22, 2012
Cisco c4948e switch log is showing :
COMPACTFLASHNOTREADY: Compact flash is not ready
Feb 24 00:28:22.338 UTC: %C4K_FLASH-4-COMPACTFLASHNOTREADY: Compact flash is not ready
COMPACTFLASHNOTREADY: Compact flash is not readyFeb 24 00:28:22.338 UTC: %C4K_FLASH-4-COMPACTFLASHNOTREADY: Compact flash is not ready
Checked the data sheet and is not supported. Why we get this log from the switch? is it cosmetic?
AME: "Linecard(slot 1)", DESCR: "10/100/1000BaseT (RJ45), 10GE (SFP+) Supervisor with 48 10/100/1000BASET ports and 4 10GE SFP+ port"PID: WS-C4948E , VID: V01 , SN: CAT1425S0NZ
NAME: "TenGigabitEthernet1/49", DESCR: "SFP-10Gbase-SR"PID: SFP-10G-SR , VID: V02 , SN: AGD132134ER
NAME: "TenGigabitEthernet1/50", DESCR: "1000BaseLH"PID: Unspecified , VID: , SN: FNS141203YF
[code]...
View 3 Replies
View Related
Apr 21, 2012
I need data sheet ( technical sheet) for Cisco3660-MB-2FE router.
View 6 Replies
View Related
Apr 16, 2012
i have one of my switch modules that shows PwrDown when i issue the command show mod.
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 9 Supervisor Engine 32 8GE (Active) WS-SUP32-GE-3B SAD09120263
2 48 48 port 10/100/1000mb EtherModule WS-X6148-GE-TX SAL1029VWZ5
[Code]....
i tried disabling the diagnostic monitor for the module, did a power enable module command and then reset it but it still fails. this is the third blade that i am replacing in a few weeks and i still get the same error. i am persuded that it is not a hardware since it is the third blade in a matter of weeks. after the module reset, i receive this error % module 3 is operationally off (FRU-power failed)
could an ios upgrade solve this issue? are there any ios related bugs?
View 10 Replies
View Related
Jan 10, 2006
Any data sheet or a brochure with the ASA5510 MTBF?
View 3 Replies
View Related
Apr 28, 2012
We have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".
View 4 Replies
View Related
Feb 12, 2012
Cisco IP phones attached to a Moduke in one of my Cat6500 access Switches suddenly went down. Upon closer inspection of the Switch Sys log, I observed the following Sys log error messages: [Module 9 is experiencing the following error: Inline Power Module - PS Voltage bad. ]A sh Mod output indicates the PoE daughter card and Main Module are "ok" - see attached output. It appears issue is related to the the actual Power Supply module and not the blade module and installed PoE Daughter card. I am inclined to open a TAC case for a PS replacement, but wanted to see if this can be resolved without a hardware replacement. At this time all 48 IP phones attached to this module are out of Service.
View 2 Replies
View Related
Apr 7, 2012
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command:
Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
View 6 Replies
View Related
Jan 5, 2012
I have a client(C) and a server(S) nodes plus an intermediate node(I). Each node has a public IP. What I want to do is to transmit some data(whatever) from C to S but this data to go through I. So C ---> S will become C ----> I ----> S. I read something to create a tunnel(ip add tunnel) between C and I and add a route between them ? I tried different examples but did not work at all.
View 2 Replies
View Related
Dec 15, 2011
With firmware 2.06 my DIR-600 had transmit power choices 100%, 50%, 25% and 12,5%.(even 12,5% gave me excellent strength on all my devices, what is really the difference)But after updating to firmware 2.11 (via 2.10, othervise my DIR-600 refused to use 2.11)the choices for transmit power is now only "High", "Medium" and "Low". know the percentage values for those three settings?
View 2 Replies
View Related
Jun 10, 2012
I will be doing a site survey using the client's Cisco 1262 with only 1 radio (g/n), 3 antennas. What is the maximum transmit power, 20dBm or 23dBm? I need to set the transmit power in the Airmagnet to 50% or 3dBm down as recommended by Cisco.
View 4 Replies
View Related
Jan 27, 2013
I upgraded my 3602i survey ap the other day to the public image the other day and I have to say.. I've got it up and going of course, but I have a concern on the transmit power settings. Originally, the only option it gave me was MAX and -4, which I hadn't seen before, interesting.. -4 of what? 20? 17 probably or I though? At any rate, I went into the CLI to set the power manually, no issues there, though my options are not what I expected, maxing out at 25mw basically, which is fine but.. in setting it manually in CLI, the web interface reports an Error on transmit power. So.. does this work or not? Any survey with this image to verify it's power settings? 15.2(23c)
View 3 Replies
View Related
Apr 16, 2012
I have a WS- C2924C-XL switch that I would like to upgrade the IOS version on. The IOS version in question can only be installled on an 8MB version of this switch, I have tried to confirm the amount of memory present in the device but I am getting conflicting values depending on where I look.The model number would indicate that this device is a 4MB version, therefore not compatable with the upgrade.Running the show version command from the CLI shows Processor having 8192K/1024K bytes of memory.Accessing the switch via the VMS management interface displays a value of 4MB.
View 5 Replies
View Related
Apr 29, 2012
I've been working on a 3560 that doesn't seem to map dscp values to a new value: mls qos map dscp-mutation ToR1 22 24 to 46
[Code]....
On the router on the other side, I created an acl that matched on dscp 46, but it doesn't match on it. I've tried moving the mutation map to the ingress interface and I've tried setting dscp with a service policy instead of marking COS and using internal dscp. Where is the mutation map supposed to be placed: ingress or egress? Also, I added an entry in the acl on the router to see if I was mapping to dscp 24, and I am:
[Code]....
So it seems like the mutation map is being ignored completely. Any reason why?
View 7 Replies
View Related
Feb 4, 2010
We have a C4500 with 2 sup V which is showing high CPU values sometimes.When this occures, the switch shows 95-100% for total cpu for a few hours at a time.show proccesses cpu shows process Cat4k Mgmt LoPri with an unusual cpu value of 65% The show platform heath command gave me a high reading for K2FibFC DelFlow which is about 50% at this peak but is normaly around 1%?
what the process K2FibFC DelFlow means and what could be the cause of this peak?
View 12 Replies
View Related
Feb 25, 2012
We have a Cisco 6513 Switch. During some parts of the day it is having large amounts of transmit discards on a certain interface because of the amount of data we are pushing. We have determined it is a link problem and not a problem with the switch. The link cannot handle the amount of packets the switch is pushing out. I was wondering if there is a way to create a buffer or a way to regulate the maximum amount of packets that can leave that interface without losing any packets?
View 5 Replies
View Related
Apr 9, 2013
Cisco 4500-X do not support egress queing on VLAN interfaces (SVI) which means cannot do a traffic-shapping, is there a work around via policing? I can police the traffic and then on the trunk interfaces do "per-port-per-VLAN" QoS but again only the policing not shapping so I was wondering what is the effect of "exceed-action transmit" command
policy-map SHAPE
class class-default
shape-average 8000000
Versus...
policy-map POLICE
class class-default
police 8000000 4000 conform-action transmit exceed-action transmit
View 10 Replies
View Related
Mar 20, 2012
I've been having a debate with a colleague about QOS COS values. My colleague says I need to use COS values across layer 2 trunk links between access layer switches and core switches. My argument is if phones are marking packets with DSCP values I don't need to be concerned with Cos.The reason I ask is we're implementing a new phone system, the ip phones will mark RTP traffic wih dscp value EF and Call signaling with DSCP value of CS3. If my understanding is correct I can trust the dscp values of the phones. We are using Cisco 4507 switches which I believe automatically trust dscp values so I would just need a class-map to match the dscp values and apply the output policy map on the egress interfaces as follows? [code]
View 3 Replies
View Related
Oct 14, 2012
We have a 4500 series switch that is running around 39% cpu utilization but seems to be dragging a bit. I did a show platform health and GalChassisVp-review has a target of 3% but an actual of 17%. All other actual values were at or below target values. I then went to show platform cpu packet statistics and in the "Packets received by Packet Queue" all queue packet values at 5 sec, 1 min, 5 min and 1 hour avg were either 0 or 1 with the exception of Esmp - that averaged 351/377/317 and 313 respectively. I then checked show platform hardware acl input entries static and the entry type InputEsmpToCPU had a whopping 10121370 hit count. All other entry types were well under that number.
View 2 Replies
View Related
Oct 26, 2011
I'm working on a catalyst c3750 and for my work i need to prioritize certain streams independent of their bandwith usage.
The streams are the following:
- voice
- video
- data
I created policy maps based on vlans like below:
policy-map VOICE
class class-default
set precedence 5
policy-map VIDEO
[Code]...
View 7 Replies
View Related
Dec 13, 2011
After opening up Solarwinds NPM, I noticed that a few of my interfaces had lots of discards (who knows how long it's been sets the counters were reset)
interface GigabitEthernet1/0/25description Etherchannel to MamaCassswitchport trunk encapsulation dot1qswitchport mode trunkswitchport nonegotiatepriority-queue outchannel-group 4 mode on
interface GigabitEthernet2/0/25description Etherchannel to MamaCassswitchport trunk encapsulation dot1qswitchport mode trunkswitchport nonegotiatepriority-queue outchannel-group 4 mode on
interface Port-channel4switchport trunk encapsulation dot1qswitchport mode trunkswitchport nonegotiate,It looks as if priority-queue was configured outbound on these interfaces, could this be the cause of the transmit discards which are now up to 79,835, I just reset the counters on the interfaces a little while ago.
I'm not the best in the world when it comes to QoS, we do have some VoIP phones, but they are only a specific network, and do not travel outside, since there are used mainly for VoIP training. I do know both interfaces are running the default of FIFO.
View 1 Replies
View Related
Oct 19, 2011
I have a stack of 4 Cisco WS-C2960S-48FPS-L switches running c2960s-universalk9-mz.122-58.SE1 code. One of our network monitoring tools is indicating discards on a certain port on the switch. Upon further investigation I am seeing the Total output drops values change in a very odd manner.
The numbers seem to go from 573 to 1146 to 1719 then back down to 573 and it starts the same pattern over: [code]
The port utilization is quite low, the highest I've seen over the past 7 days is 3.5% with a polling period of every 30 seconds using Statseeker. Yet the discards are bouncing all over the place.
I've searched though the bugs for 12.2(58)SE1 and didn't see anything.
View 13 Replies
View Related
Jan 8, 2013
What are the best values for "mac address-table aging-time" and "arp timeout" by following scenarios?:- single sg300-10 as layer3-switch with a maximum of 10 local (direct connected) hosts - and a 3750x-stack with 100 local hosts + hsrp with a other stack of the same sort or for asa 5520 as internet gateway for 500 clients?I use at the moment a mac aging-time from 300 seconds and a arp timeout from 3600 seconds.
View 6 Replies
View Related
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 14, 2013
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
View 1 Replies
View Related
Feb 28, 2011
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
View 3 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Jul 23, 2003
Running WLSE 1.3 and it shows No Data Available. Checked the task history for Inventory collection and it is not collecting. All the processes are running. Unable to gather data. SNMP community strings are configured and devices are accessible (AP350's).
View 3 Replies
View Related
Apr 5, 2011
I am monitoring my WRVS4400N with SNMP and create graphs by MRTG. Problem is that data about traffic are strange, very low. I have 50 MB line but max traffic shown on graphs is about 8000 bits per second. Also the "shape" of graph does not correspond with real traffic.
View 1 Replies
View Related
Jul 17, 2012
I have connected 2 SG500x switches using an SFP-H10GB-CU1M SFP+ Copper Cable module. Since the port shows as a 10G port, I would expect the speed to show as 10G as well. However, it shows as "Unknown". This doesn't leave me with confidence that it is being recognized properly. The link is working properly, but I haven't run tests to verify if I'm getting full 10G throughput or not. Shouldn't it show 10G as the link speed?
View 12 Replies
View Related
May 23, 2013
We have a Nx5548up pair connected to FI6248 via a vPC. We had to reboot a FI (in order to configure more FC ports) ; following that reboot, we meet many issues.The first log shows the vPC down showing the FI rebbot.2013 May 23 12:31:45 sw-n5kup-fr-eqx-01 %ETH_PORT_CHANNEL-5 PORT_INDIVIDUAL_DOWN: individual port Ethernet1/2 is down
View 1 Replies
View Related
May 20, 2012
I have installed a WS-X4448-GB-RJ45 on a 4503 chasis. I could not get input or output rate, just shows 0 bit/seg wether or not is forwarding traffic. I would like to know if I have to make any configuration or workaround. The IOS version is 12.2(37)SG1.
View 1 Replies
View Related