Cisco Switching/Routing :: WS-X4548-GB-RJ45 Frequent Input Errors Of Module Interface

Oct 21, 2012

I have been making effort to solve frequent input errors of module interface(WS-X4548-GB-RJ45) in our Backbone Switch(Cat4506).Let me show you show interface information.Rx-No-pkt-buff value is increased continuously even though traffic rate of interfaces is lower than 20Mbps.We have two Backbone Switch which is operated by HA via HSRP.What bring buffer shortage to our network ? [code]

View 2 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Input Errors On Many Interface WS-C3750G-12S

Apr 16, 2013

We are facing since one month in our two Cisco WS-C3750G-12S on many interfaces input errors when data transer or ping (ICMP) increase input erros. Not only port 1 but many interface has same issue, i have change new IOS but still same issue, once i have erase startup config but same issue we are facing and finaly i have replace same new switch with the same IOS it's working fine.(c3750-ipservicesk9-mz.122-55.SE4.bin) [code]

View 11 Replies View Related

Cisco Switching/Routing :: Etherchannel Limitations WS-X4548-GB-RJ45

Dec 13, 2011

Any limitation on building an etherchannel on the abovementioned linecard, when bundling more than one port on the same card? The 4506 is using a 6L-E supervisor engine 12.2(54)SG1.
 
If it's done on a 6500 with a WS-X6148-GE-TX linecard it effectivley can only reach 1gb throughput.

View 2 Replies View Related

Cisco Switching/Routing :: Module Ws-x4548-rj45v+ And 4506 Switch

Oct 4, 2012

I have a problem with a newly bought ws-x4548-rj45v+ i've plugged in the module but when i do show modules all , it show as unsupport
 
Power consumed by backplane : 0 Watts
Mod Ports Card Type                              Model              Serial No.---+-----+--------------------------------------+------------------+-----------1     2  Supervisor IV 1000BaseX (GBIC)         WS-X4515           JAE1048GAXQ2    48  10/100/1000BaseT (RJ45)                WS-X4448-GB-RJ45   JAB064806WN3    48  10/100/1000BaseT (RJ45)                WS-X4448-GB-RJ45   JAB063005DB4     0  Unsupported module                     WS-X4548-RJ45V+    JAE1545056U
M MAC addresses                    Hw  Fw           Sw               Status--+--------------------------------+---+------------+----------------+---------1 0007.0e64.f880 to 0007.0e64.f881 5.2 12.2(20r)EW1 12.2(46)SG       Ok2 000b.5fa4.da20 to 000b.5fa4.da4f 1.0                               Ok3 0009.e844.d760 to 0009.e844.d78f 1.0                               Ok4 ccef.4815.9bf0 to ccef.4815.9c1f 2.0                               Unsupport

View 2 Replies View Related

Cisco Switching/Routing :: Install Line Cards (WS-X4548-GB-RJ45 / Chassis WS-C4510R-E) On Chassis Ws-6504-E?

May 15, 2012

we need to install a line cards (WS-X4548-GB-RJ45, chassis WS-C4510R-E), on a chassis Ws-6504-E.where I can find information about compatibility?

View 2 Replies View Related

Cisco WAN :: Input Errors On 1841 LAN Interface

Nov 4, 2011

I use an 1841 router as an internet facing firewall with a 10MB MetroE connection.  Lately users started reporting slow internet download speeds and web pages timing out.  Bandwidth reports do not show the link as being saturated so I looked at the interfaces on the 1841.   The interface connected to the provider shows OK as far as errors but the LAN side of the router shows steadily increasing input errors.  It doesn't show any other errors, no CRC, frame, runts, giants or overruns, just generic input errors.  What type of errors are those?  Nothing is being logged on the console.
 
I moved the connection to another switch ports and the errors continue.  I switched it down to 10MB and also changed the switch and the errors slow down but don't stop.  Interestingly, the switch side never shows any errors.  What can I do here?  I guess it can be a bad interface but that is such a rare thing that I am hesitant to replace the router.

View 11 Replies View Related

Cisco Switching/Routing :: CRC And Input Errors On WS-C2960-24TT-L?

Jul 1, 2012

I am not sure why the CRC and input errors are increasing in fastethernet port...This port is used as Intradomain cross connect to Data Center service provider for LAN extension between two Data Centers in different locations... The link is 100 MB. The switch port is directly connected to patch panel of DC provider and I believe they have some L3 switch or some other device that is providing LAN extension...
 
#sh interfaces fastEthernet 0/23
FastEthernet0/23 is up, line protocol is up (connected)
  Hardware is Fast Ethernet, address is 0019.3050.1497 (bia 0019.3050.1497)
  Description: ASA_VPN_TO
  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,

[code]....

View 26 Replies View Related

Cisco Switching/Routing :: CRC And Input Errors On WS-C2960-24TT-L

Oct 2, 2012

I am not sure why the CRC and input errors are increasing in fastethernet port...This port is used as Intradomain cross connect to Data Center service provider for LAN extension between two Data Centers in different locations... The link is 100 MB. The switch port is directly connected to patch panel of DC provider and I believe they have some L3 switch or some other device that is providing LAN extension...
 
#sh interfaces fastEthernet 0/23
FastEthernet0/23 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0019.3050.1497 (bia 0019.3050.1497)

[Code].....

View 3 Replies View Related

Cisco Switching/Routing :: ASR 1002X Receiving Runt And Input Errors

Mar 15, 2013

I have an ASR 1002x connected to a 6513.  Connection is from ASR Gig Copper SFP to 6513 Copper 10/100/1000 port.  The ASR is recevinig Runt and input errors.  I have removed the negotiation auto command on both boxes and hard coded the speed etc and still errors occur.  I have also added the negotiation auto to both devices and also removed it with out hard coding the speed at and same results.  Everytime I have seen these errors is has been to collision caused by a duplex mismatch.

View 4 Replies View Related

Cisco Switching/Routing :: 3560G Input And Crc Errors Only On Built In Ports?

Mar 11, 2013

I have an odd situation where I cannot get a device connected to a built in switchport with out input and crc errors.  When connecting to a GLC-T sfp it works fine.Here is my test layout
 
Outdoor wireless AP --- 10' of cat6 cable --- Gigabit POE injector --- 10' Cat6 cable --- 3560G port 48.  (input and crc errors)
 
When I do this there are input and crc errors on the switch port.  This has been confirmed on three different switches and three different outdoor AP's.  We though at first it was the injector, but when we run the same setup, but instead connect the device to port 49 with a GLC-T sfp there are no errors.
 
Outdoor wireless AP --- 10' of cat6 cable --- Gigabit POE injector --- 10' Cat6 cable --- 3560G port 49 (GLC-T).  (No errors)
 
I have upgraded the 3560G to the latest ios and still it has the same problem.  If I run the same setup to a 2960 there are no errors at all.
 
Outdoor wireless AP --- 10' of cat6 cable --- Gigabit POE injector --- 10' Cat6 cable --- 2960 port g0/1  (No errors)
 
I have also tried manually setting the speed on the 3560G with no success. 

View 9 Replies View Related

Cisco Firewall :: How To Clear Input Errors In ASA5540 Interface

Feb 26, 2013

My Expertise with Cisco ASA is Very less. I have observed Input errors in a Couple of Interfaces in Cisco ASA 5540 Firewall.   [code] I need to Clear the Input errors on this particular Interface.Will Clear interface GigabitEthernet 0/0 will work?

View 4 Replies View Related

Cisco Security :: ASA5540 Interface Input Errors - Overrun

Nov 16, 2009

Why packets overrun are incrementing on the ASA even when I've only 40Mbps of throughput traffic?All interface are 1000- Full Duplex, both on ASA and on Catalyst3750.I've test the ASA5540 generating GET HTTP, about 40Mbit of traffic.When I use one ingress interface and one egress interface, interface input overrun counter is zero.When I use the same traffic with 3 ingress interfaces(slot0) and 3 egress interfaces(slot1), interface input overrun counter increase(60k overrun in only 2 minutes).

View 4 Replies View Related

Cisco WAN :: Input Errors On Fastethernet Interface Router 2811

Feb 22, 2012

I have this output from show interfaces command for the fastethernet interface on a 2811 router.
 
find the causes of the crc and the ignored input errors on the interface?
 
The interface  configuration is:
 
interface FastEthernet0/0description VLANS_CHILE
no ip address

[Code]....

View 6 Replies View Related

Cisco Firewall :: 5580-40 - Input Errors / Overruns And Reset Drops On 10Gig Interface?

May 10, 2012

I have an issue with input errors, overruns, and input reset drops on the inside interface of an 5580-40 (v8.2.5: Transparent mode)  The box is not stressed at all according to the 'show' commands in the Cisco troubleshooting performance document for PIX/ASA v8.2.5.  Nothing stands out because is pretty much normal, nothing (processes, RAM, blocks, IO...) really being highly utilized.  I have replaced the 10Gig card and that seemed to work because the rate of errors has gone down tremedously.  The next step is to RMA the whole box.My question is what would be the cause of the inside interface to stop processing traffic (I say that because the syslog server stops receiving messages) for some periods of 30 seconds periodically throughout the day and clients lose their connections (ie Outlook, IBM Sametime, Oracle, MSSQL..etc).  Can the issue be somewhere related to the overruns and input errors?

View 2 Replies View Related

Cisco Switching/Routing :: RJ45 - Getting Expanded C3KX-NM-1G Module?

Dec 29, 2011

A product I could have used a number of times is a expanded version of the C3KX-NM-1G device module.  To include 2 or maybe 4 more SFP ports.  From the layout behind the faceplate there is plenty of space which additional circuit boards could be placed, (which is used in the 2 port 10GB version).  I don't need the 12 port fiber switch that Cisco has, because I need a few RJ45 connection at that location, which I would then have to buy additional Fiber to coper Gbics for a few connections where the switch is at.  The reason I need something like this is I have a few locations which I get a main feed from the City fiber, then it gets sent out to a number of local buildings on my fiber.  Maybe another option is to take the 12port switch, and have an option for 6 rj45 and 6 sfp connections. 

View 8 Replies View Related

Cisco Switching/Routing :: CAT 4500E Installed With WS-X4648-RJ45-E Module

Jun 29, 2012

I have cat4500 with subject module. There is strange behaviour over module installed in 3rd slot only, some ports are connected, UP & working fine. But If I am connecting new ports over same module, are not coming UP.Duplex/speed settings already checked & are fine. If i connect same machine to any other module, it perfectly comes up & operation is fine.

View 3 Replies View Related

Cisco Switching/Routing :: 6509 Module Results Show Pass And No Errors In The Logging

Sep 18, 2012

We have a design of two 6509 running in a VSS with dual supervisor each having fthree 10/100/1000mb etherner modules. We have diagnosed a wierd problem that none of the switchports in module 1 and 2 on either switches are having layer2/layer 3 connectivity.
 
Tried everything from changing the cables to changing the end device but no luck with it.
 
Module results show pass and no errors in the logging.

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 4506 Count Interface Input / Output Rate Always 0

Jan 20, 2013

Our customer get the problem that the switch count the 5mins input/output rate of connected traffic interface always ZERO.The problem only occur in the module 3,4 and 5 interface, module 2 has no problems.
 
-------------------------------------------------------------------------------------------------
Catayst 4506E
12.2(52)SG
 Chassis Type : WS-C4506-E
Power consumed by backplane : 0 Watts
Mod Ports Card Type                              Model              Serial No.---+-----+--------------------------------------+------------------+-----------1     6  Sup 6-E 10GE (X2), 1000BaseX (SFP)     WS-X45-SUP6-E       2    48  10/100/1000BaseT (RJ45)                WS-X4548-GB-RJ45   3    48  10/100/1000BaseT (RJ45)                WS-X4648-RJ45-E    4    48  10/100/1000BaseT (RJ45)                WS-X4648-RJ45-E    5    48  10/100/1000BaseT (RJ45)                WS-X4648-RJ45-E   

[code]....+

View 2 Replies View Related

Cisco Switching/Routing :: 2921 / Catalyst 3560 - Router Interface Input Queue Drops?

Nov 6, 2011

i have an 2921 connected to an Catalyst 3560. My router interface shows quite a lot of input queue drops. Load is not too much max 5/255.

View 1 Replies View Related

Cisco Switching/Routing :: 2911 - Assign IP To Interface In Module?

Jul 25, 2012

I need to configure a Cisco 2911. I need to give an interface in this module (VWIC3 - 4MFT-T1/E1) an IP address. My question is, how to assign an IP to an interface in this module.
 
My purpose is to get connectivity via T1 line to another router.

View 16 Replies View Related

Cisco WAN :: Output Drops And Input Errors On 7204 With NPE 300

May 11, 2011

My router, a Cisco 7204 with NPE 300, is experiencing output drops and input errors on a fastethernet interface. I have a 100Mbps connection with less than 15Mbps utilization at peak times.
 
FastEthernet1/0 is up, line protocol is up  Hardware is DEC21140, address is 0014.a985.1a1c (bia 0014.a985.1a1c)  Internet address is 38.102.66.134/30  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,     reliability 255/255, txload 3/255, rxload 1/255 

[Code]....

View 17 Replies View Related

Cisco :: 3560 Not Showing CRC And Input Errors In Logging

Oct 21, 2012

I ran into a problem a few weeks ago and am still trying to figure out why either the 3560 switch or our Cacti syslog server did not alert us when one of our ports was experiencing heavy CRC and Input errors. 
 
I had upgraded the IOS to 12.2(55)SE6 and rebooted the switch.  About a week later, someone was troubleshooting why print jobs were having problems printing to a high speed printer.  When I looked at the interface it showed a few thousand CRC and Input errors.  I cleared the counters and had them print again and watched as the CRC and Input errors went up.  When I did a "show log" there were no error messages.  Looking at our Cacti Syslog there were also no errors present for the past 6 months.
 
We found that the device on the port was set to auto speed and duplex and the switch port was at 100/Full.  Once we got them to match the problem was resolved, but we were left wondering why we never got any alerts.
 
We also have some 3548 and 3550 model switches that Cacti picks up %LINK-4-ERROR for any ports that show CRC and Input errors.  I did some research and it appears that the 3560 switches do not have the LINK facility code.  I believe it has been replaced with a PHY link code but I'm not sure.  We do have some "%PHY-4-EXCESSIVE_ERRORS: Excessive FCS, data, or idle word errors found" but they are all for 3750 switches.  I could not find any 3560 that had alerted for that error or the LINK error.
 
I also tripped port security on the 3560 switch just to make sure that it was reporting correctly to Cacti and that alert did show up. 
 
My question is how do I get a 3560 switch to alert in the logging buffer for CRC/Input/FCS errors?  Also, how I can generate CRC and Input errors on purpose for testing?  I tried mismatching the speed/duplex/Auto and only got collissions, no CRC or Input errors.

View 2 Replies View Related

Cisco WAN :: 1812 Input Errors On Fast Ethernet Increasing

Dec 5, 2011

I'm using a Cisco 1812 to route traffic from a small location with 10 users.. Users are complaning about packet loss, and programs with live database connection is freezing..On the router i've checked one of the Fastethernet interfaces, and I can see that the input errors are increasing constantly. [code]

View 5 Replies View Related

Cisco Firewall :: 5540 ASA Interface Input Error On Outside Interface

May 28, 2013

We are having Cisco ASA 5540 having Cisco Adaptive Security Appliance Software Version 8.0(5)23 at certain time of moment daily wer are facing latency and packetdrop wherin when I checked for ASA Interface which gives me " Input Errors" on outside interface ,so can any one tell me what are the causes to get input errors on cisco asa outisde interface.

View 2 Replies View Related

Cisco Switching/Routing :: Frequent High CPU Load In 7609 Routers?

May 3, 2012

we have a pair of 7609 routers working in Active Standby mode. The version of routers are :- Cisco IOS Software, c7600rsp72043_rp Software (c7600rsp72043_rp-ADVIPSERVICESK9-M), Version 12.2(33)SRD4, RELEASE SOFTWARE (fc2)
 
Quiet frequently we are getting High CPU load problems on our router and this load comes down below 10 % automatically.
 
I am attaching the Show tech support for your kind consideration.
 
Similar issue was reported yesterday as well for which i have attached SH tech suppot.

View 2 Replies View Related

Cisco Switching/Routing :: Does WS-X4748-RJ45-E Support The 802.1x

Nov 10, 2011

this module WS-X4748-RJ45-E able to support 802.1x?

View 1 Replies View Related

Cisco Switching/Routing :: 4900M - Facing High Frequent Interfaces Flaps

Feb 18, 2013

We are facing issue with highly frequent interface flaps on Cisco 4900M switch only for module WS-X4920-GB-RJ45. Strange thing is no complaint from the users/server teams for any traffic interruption.
 
Switch: Cisco WS-C4900M

Line card: WS-X4920-GB-RJ45

IOS image is cat4500e-ipbase-mz.122-53.SG4.bin
 
There are several other smilar model & linecard/inventory of switches with exactly same IOS image, however there are no issues with them.

View 5 Replies View Related

Cisco Switching/Routing :: Additional RJ45 Port Required On 1941 ISR

Nov 16, 2012

One of branch locations has a Cisco 1941 Router . The port details are as follows
 
-Gi0/0 - ISP line
-Gi0/1 - Inside Network ( To a 2960 Switch)
 
Now they have procurred another line from ISP through which  MPLS based VPN to the Main location is configured. What are the options I have , to terminate it on the Router ? As all the On board LAN ports are filled I guess I wont be able to do anything with the current setup .Are Switching modules available ? What is the Embedded-Service-Engine0/0 port that I see on #sh ip int b output ?

View 4 Replies View Related

Cisco Switching/Routing :: 3750-E - High CPU Due To ARP Input

Feb 4, 2013

my 3750-E Core Stack is connected to the Provider Router and is the DG for the internal LAN. I saw that the CPU is very high also in the night, but I found not the problem. I use an SVI to connect the provider due to HA reasons. I sniffered the network but saw no ecessive broadcaststorms. There was a PBR configured but I deleted it wihtout any success..
 
switch Version
15.0(1)SE1 
10#sh proc cpu so

[Code]......

View 6 Replies View Related

Cisco WAN :: RJ45 - Interface Still Marked As Up Even Cable Unplugged

Dec 29, 2010

my senario is:
 
f0/1(dialer 0)<----RJ 45----->ADSL Modem<------>ISP
 
but even I unpluged the RJ 45 cable, the dial 0 still marked as up (interface and protocol), the f0/1 was marked as line up and protocol down.

View 2 Replies View Related

Cisco Switching/Routing :: 4900M WS-X4908-10G-RJ45 Port Startup Delay

Mar 4, 2013

We have recently purchased 2 x 4900M switches with the following configuration:
 
2 x X2-10GB-SR installed in port te1/1, 1/2 (optical)
 
1 x 20 x 1GB RJ45 installed in the top left of chasis ge2/1 - 2/20
 
1 x WS-X4908-10G-RJ45 8 port 1/2 card in the top right of chassis te3/1 - 3/8
 
We have te1/1 connecting the 2 switches, and various vlan's and connections on the 1GB RJ45's with no problems.
 
However, we have a number of 10Gbps BaseT connections te3/1 - te3/5 which are causing us issues. On a reload of the switch or removal / re-install of the cable it can take anywhere up to an hour for the port to become active again. So when we reload the switch, we may get a connection come up after say 3 mins, but the port next to it may not come up for 15-60 min. The cabling is all the same (CAT6 and has been tested/verified) and all connections go to Broadcom 10Gb cards in Dell 820 servers running vmware. We have the following set on the ports:
 
switchport mode access
spanning-tree portfast
 
No speed or duplex can be set on these ports - these options are not available in the config.
 
Once a link is finally established, it will hold the link solid with no problems, but this is a problem for us, we can't have a reboot take an undetermined amount of time for the link to come back.

View 15 Replies View Related

Cisco Switching/Routing :: RP / Input Drops On 6500 Sup 720 10GE

Jun 17, 2012

What does RP drops entail? We are experiencing 0.23 % drops on an vlan int on one of our 6500. This interface is an L3 to a server-subnet. Doing a sh int vlan 238 switching shows 30935411 RP (Route Processing) drops.It was a bit unclear to me in the thread "Input queue drops on 6500 vlan interface" if RP drops was through the router, or to the router(mgmnt)?I can do a netdr to see what traffic goes to it. It should not generate CPU load, but I think I will wait until after hours before I try that command.

- do NETDR:
-- debug netdr cap rx vlan 238
-- show netdr cap

View 5 Replies View Related

Cisco Switching/Routing :: Cat 6509E 6Kw PS AC Input Level Verification

Oct 27, 2011

I have a 6509E switch with dual 6Kw power supply that is logging "Power supply 1 input has changed.  Power capacity adjusted to 2671.20W" then will bounce back to normal at random times from 1sec to 10sec. Is there a command to check what each input level of the power supply to try to identify possibly which source is causing the problem? The power supply input lights remains green while this is occuring.

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved