My CORE Switch 4507R Suddenly restarted (Powe is good) , and gets the business down for 30 Mts,my boss came to me and asks why it has restarted , what is the root cause of this restart, i dont have any syslog or NMS enabled in my network to be informed
Router is Airport. Interference to all am radios (in both cars, transister radio, and plugged in clock radios) within 10 m radius of our house. Have had router for two years, but problem started suddenly last Sunday morning. Figured it was the router by turning it off (no interference) then on again (interference returned).
I'm having issues getting the ports g3/5 and g4/5 from inactive to notconnect.
I have tried the hw-module uplink select all in the global configuratio, but it's not working, getting a : % Invalid input detected at '^' marker. Message every time.
This what I have:
Power consumed by backplane : 40 Watts Mod Ports Card Type Model Serial No. ---+-----+--------------------------------------+------------------+----------- 1 48 10/100/1000BaseT (RJ45) WS-X4548-GB-RJ45 JAE152101QK
I installed LMS 4.0 succesfully, but when i go to topology, can view all network, but the "AswitchA" Core 4507R+E be displayed as "?"
And it can not display this "AswitchA" into CISCO VIEW, display this messaje :
"Cannot find applicable device package for ... This error could be due to one of the following:
- The device package for this device type is not installed. - Device support for this device type is not available. - You are trying to open a component inside a device.
To correct the problem, either install a device package for the device type, or open the parent device to manage the component."
I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
SWITCH-4507#sh ver Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version 12.2(25)EWA8, RELEASE SOFTWARE (fc1) Technical Support: [URL] Copyright (c) 1986-2007 by Cisco Systems, Inc. Compiled Wed 24-Jan-07 15:28 by pwade
I'm in the process of upgrading my 4507R core to a new 4507R-E. The old switch has Sup IV engines (WS-X4515) running IOS 12.2(40)SG and the new switch has Sup 6L-E engines running 15.1(2)SG. I'm trying to "move" my configuration from the old switch to the new. Below shows the commands configured in the old switch. I'm trying to determine how to implement the same configuration on the new switch since these commands are no longer available.
last day i went to one client for the installation of C(WS-C4507R+E)
current ios :cat4500e-ipbase-mz.122-53.SG2.bin
there is only one sup engine installed and redundant slot is empty.
I installed one ethernet module in the slot 6 and it get detected working fine. I also want to install one fiber module but that module is only supported by 12.2 54 sg or later ios version.so i need an ios upgrade.
For the ios upgrade I decide to do it through svi interface For that i igive an ip address to vlan 1 (192.168.1.2) and plug cable in gigabit 6/1 and added that port into valn 1.
my laptop's ip is 192.168.1.1 @ this point i faced a rare problem the PING IS NOT WORKING.(switch is directly connected to my laptop).
Then i create another VLAN (2) and add that port into vlan 2 still ping is not getting.last thing i tried is that making that gigabit port into a routed port and result is same.
We made an IOS doBlades on switch 4507R keep block after an IOS downgradewngrade. Before to do it, the equipment comes with blades 1, 2, 3, 4 and we insert "X4418" and "X4548" on blades 5 and 6.[code]
After we made an IOS downgrade to a cisco 4507R from "cat4500e-ipbasek9-mz.122-54.SG.bin" to "cat4500e-entservicesk9-mz.122-53.SG2.bin" (comes with a redundancy supervisor blade WS-X45-SUP6L-E) the standby supervisor keep disable.We tried with the command "Switch(config)#boot system flash cat4500e-entservicesk9-mz.122-53.SG2.bin" then save configuration and "reload" comand but the switch runs with the "...54.SG.bin" IOS.
We erase the configuration with the command "erase/all non-default", before to apply the reload command insert the "entservicesk9-mz. 122- 53. SG2.bin" using the tftp command.The standby supervisory remains on disable state but the active supervisory runs with the desire IOS. In order to downgrade the IOS to the standby supervisory the active supervisore was removed temporarely (previously the switch was off) to make the standby as active, after that made the same procedure with command "erase/all non-default", "copy tftp://(....122-53.SG2.bin), and "reload" command.
The switch was off and re-insert the active supervisory and turn on the switch, after we made the procedure the blade "WS-X4548-RJ45" marks a fault as follows: [code]
The blades were reset but don't have access to them.
I read quite a few documents on configuring SPAN on a cisco switch but none of them mention any limitations or any kind of CPU load it can have on a switch. I need to configure this on one of our switches and would like to know if there are any implications related to SPAN.
We are using CISCO 4507R-E switch as our core/distribution switch. Out of the 7 available slots, 3 are currently being used. Descriptions is as follows:
Slot 1: 6 Port Fiber Line Card
Slot 2: 6 Port Fiber Line Card
Slot 3: Supervisor Engine
Slot 4: Empty
Slot 5: 48 Port Copper Line Card
Slot 6: Empty
Slot 7: Empty
We want to add extra 10 Gbps fiber links (approximately 12) using slot 6 and 7.
We got a switch issue here for 4507R-E with two sup6l-e supervisor running sso redudant. and we found that sometimes client can't ping through the local vlan ip add on the switch , can't logon the cli by telnet too. In the direct connected network device such as access switch and ASA , can't ping or telnet the 4507R too. when we made a forceswitch to sso standby supervisor from console , the problem solve and everything get fine . after that, we switch angin back to the origin supervisor , fine too.
before we made the supervisor forceswitch , we had check the system cpu usage is 15 - 20 % from console . also we had creat a new vlan 200, attach the notebook to 4507's vlan 200 port , the notebook can't ping or telnet the vlan 200 ip interface too.
I have one cisco 4507R+E.My question is if the IOS of the acive SUP crushed and the switch is running through it's second SUP then how to restore the IOS of the first SUP.Also how to access the ROMON mode of the crushed SUP when switch is running through second SUP.
In my Company there is a core Switch 4500 series , to which in the 1st module servers are connected and in the second module 2960 , 3750 series Switches are connected, problem is that the Utilization of Core switch is very high and the core gets hanged. the configuration of the senerio is VTP domain i.e core is Server and the rest are Clients....
there are more than 15 servers which include xen,esx,vmware,also san etc..which are connected to L3 core switch directly. And vlans are created for each.....xen,iscsi,vmware,xen,server. wanted to know is there any other technology other than directly connecting servers to core switch and assigning vlans that can be used in place?
We have a L3 core switch with multiple VLANs setup. Is there a way to place an IPS so as to monitor the traffic passing between, lets say, VLANS 1-3 and VLANs 4-10?
I am facing issue with LMS 4.0. The Core Switch is showing in RED color,and device type as UNKNOWN. It was working fine but some how it is showing this problem.
I want my core switch auto failover to other route if the primary route is link down it will go to the secondary route
example ip route 0.0.0.0 0.0.0.0 1.1.1.1 ip route 0.0.0.0 0.0.0.0 2.2.2.2 100
if my core switch detect next-hop 1.1.1.1 it will re-route and go to the 2.2.2.2 for the next-hop my core switch using static route and cant support ip sla
I am getting following error in Cisco 6509 switch.BUt there is no impact in the switch.
: %MAC_MOVE-SP-4-NOTIF: Host 0000.0c07.ac01 in vlan 694 is flapping between port Te8/1 and port Te7/1 29:33.959: %MAC_MOVE-SP-4-NOTIF: Host 0000.0c07.ac01 in vlan 269 is flapping between port Te7/1 and port Te8/1
I tried to implement WLC5508 in my network but when I came to connect it to the switch core which is a Catalyst 4000 the link didn't get up. This switch module is a fastethernet, I wonder if that might be the problem since I also tried connecting my laptop to the WLC and the link got up.
If that might be the cause, is it possible to get WLC to 100 Mbps?
I got new task moving WS-3560X24 port layer 3 core switch from one branch to be moved to my branch and connect WS3560 layer 3 core switch my site network. Both core switch has got 3-4 cisco 2960 switch underneath and lots of vlan offcourse. I am thinking about creating etherchannel between these two switch.
I have a L3 core switch with multiple VLANs setup. Is there a way to place an IPS so as to monitor the traffic passing between, lets say, VLANS 1-3 and VLANs 4-10?
i have configure new ACE 30 module on top of 6500 core switch , the issues am facing whenver i want to access to https://ACE_IP and after i enter the user name and the password , it's forwared me to the follwoing page: is there anything should i configure to avoid this page ?
i configure the uplinks as etherchannel, i configure two svi interface on core switch int vlan 51(192.168.51.1) and int vlan 50(192.168.50.0) for this two svi int i configured two dhcp pool , when any of the pc is requesting for dhcp add i am getting dhcp request failed/
I'm trying to decide what switch to use as a core for 500 users. I'm currently looking at either 2 x 3750X stacks or 2 x 4500s with dual SUPs and PSUs, both options will provide the number of switchports required without the need for additonal access layer swiches. Which switch option is best to go for here? All of our services will be located in our data centre which will be connected using 2 1000Mbps MPLS circuits. I wont need any advanced L3 features and we are not likley to scale over 450 users. Also is it ok to use the dual switch stacks or chassis to provide the collapsed core/access layer or is it best to have a dedicated core (using one of the above options with less switchports) and having a dedicated accesss layer using 2960Gs for example. Our structured cabling terminates in a single comms room so we wont need to distribute switches throughout the office.
we have Core-Siwtch 4503 in the main building which is connected to another Core 4503-E in another building ,, now our PCs connected to the 4503-E ,,, any XP M/C can pick an Dhcp-ip but and M/C run Win.7 Cannot !!
action taken :
1st we try to connect our win 7 pc in the node which was connected to xp M/C ,, and it didnot take ip from the DHCP . ,, 2
2nd we ensure from the core-switch configuration and its normal with no mistake
3rd trying to use tool from Microsoft Fix-it Center whih name is ( Microsoftfixit 50475 ) which is just .msi file but the problem face us is that this tool donnot accept to run on win 7 cause its made for vista .
4th after some researchs we notic that there is some modifications have to be performed on registery by disabling the dhcp broadcast flag we did it but nothing change yet
5th now we are waiting to perform another action which is Disable the IP Helper service in win 7
I am doing an evaluation of LMS 4.0. I have loaded the system on Windows and manually added my core 3750 switch into the system. Device availability is showing the device as available. However, the other pollers like link utilization, error count, etc. all show that there is no data. When I go into the poller config, the pollers for link utilization and errors show 0 devices associated and a status of "instance not found". The CPU and availability pollers show active with my one device added. I have verified the credentials and if I go into Inventory -> Port and module and select my 3750 I do get a list of all the interfaces and the descriptions so LMS is connecting to the switch and pulling data.
So how do I get the pollers for link utilization and errors to start populating data?
Second question, during install I did configure the software update section and it said there was an LMS 4.0.1 available which I told it to download. Now I have a psu_download directory and some more directories like cm, cmf, etc. but I don't see any file on what to do with them. What do I need to do to install the new package files that were downlaoded to psu_download?
At our site we have a 4510 core switch and 3750x switches in our IDFs. The 3750 switches are connected to the core via DOT1Q trunks in a server client setup. We are putting in an Informacast/Berbee server witch will send pages and text to the cisco phones. We also have 1 3750 switch connecting to the core via a layer 3 port channel. If we put the Informacast server on the phones vlan would I just need to enable ip pim sparse-dense mode on that vlan only and enable multicast routing, ip multicast routing?