How Should Stack Behave During A New Connection
Feb 25, 2013
I an an engineer who inhertited an embedded TCP stack which may be misbehaving. This device serves up web pages and works well in most situations. The embedded server typically sends two 1260 byte packets then receives an ACK for just one packet. Then it sends two more packet and gets one ACK. This soon has the "bytes in flight" up to 60k bytes ahead of the ACKs and then things begin to fall apart. Packets begin to be lost in router(s) and dup ACK's appear. The server responds with a fast recovery but by that time it is somewhat hopeless and the connection "collapses". I have studied RFC 2581 and believe the stack is in compliance.How should the stack behave during a new connection? Should it wait for an ACK before sending the next packet? Any other RFC's or docs that I should look at?
View 5 Replies
ADVERTISEMENT
Jul 12, 2011
Can the ACE appliance behave as a reverse proxy for http and ssl traffic? I would assume it can given how it does SLB but SLB is not a requirement at this time.
View 2 Replies
View Related
Mar 18, 2013
I bought an ESW 540 8-port switch, mainly for the POE capability over all 8 ports, so that we can power some SPA50X phones.The concepts of a "managed" switch are challenging for a newbie.Is there a way to make this device behave like a boring "unmanaged" switch ??We have plenty of bandwidth, and don't need to be troubled by QoS and virtual LAN's, or all the security stuff at this time.Making this device work like an unmanaged switch (aka plug-and-pray).
View 2 Replies
View Related
Feb 27, 2013
Is there a stacking cable that is "bent"?Im using this cable:"CAB-STACK-50CM", "Cisco StackWise 50CM Stacking Cable".But it takes up to much room in the back of the switch, is there such a thing as "bent" stacking cable.
View 1 Replies
View Related
Oct 31, 2012
I have 3 switches in my 3750 X stack. I am getting the following error in the logs: %PLATFORM_STACKPOWER-4-PRIO_CONFLICT: Switch 1's power stack has conflicting power priorities. Not sure what I should do next. Below is my Stack-power configuration:
Power stack name: Powerstack-1 Stack mode: Power sharing Stack topology: Ring Switch 1: Power budget: 735 Low port priority value: 20 High port priority value: 10 Switch priority value: 2 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: c464.1308.7900 Neighbor on port 2: e8b7.4827.e680
Switch 3: Power budget: 729 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd9.9f00 Neighbor on port 2: 2894.0fd8.e200
Switch 2: Power budget: 690 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd8.e200 Neighbor on port 2: c464.1308.7900
Each switch has its own 715W power supply in it and all check out OK.
View 3 Replies
View Related
Sep 24, 2012
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
View 8 Replies
View Related
Jan 22, 2013
We currently have as our stack master a 24 port Non-PoE that we want to replace with a 48 port Non-PoE. The 48 port switch at one time was provisioned as switch 3 in the stack (not the master). Correct me if I am wrong, but theoretically all I should need to do to get this working is to shut off the existing master so it re-elects a master and then provision the 48 port switch as the new switch one and make sure switch 1 has a high priority?
Do I need to write erase the switch that is replacing the current master first?
View 4 Replies
View Related
Mar 24, 2011
I have a cisco 3750v2-48TS connected to a cisco 3750v2-48PS in a stack. The stack ports show up as down/down in the stack.Is there a limitation as to if they can be connected.? I mean can we have a PoE and a non PoE in the stack?
View 1 Replies
View Related
Jun 25, 2011
For protection of any network architecture,use of firewalls (either hardware or software) only at Network ,Transport and Application Layers of TCP/IP stack. Why not at remaining layers?
View 1 Replies
View Related
Jul 10, 2011
this occurs when I am checking my email,and it blocks me what can I do?
View 1 Replies
View Related
Oct 3, 2011
I would like to find out if the Cisco SFE2000p supports Link-Aggregation in a stack. For instance Unit 1 interface 1 and Unit 2 interface 1 in the same LAG?
View 1 Replies
View Related
May 1, 2011
I have been seeing high CPU on a 3750 stack we use for our phone system. I followed the documentation here:
[URL]
This documentation pointed out that the interrupt was very high and so I started looking at the CPU queues to debug. The icmp queue was dropping TONS of traffic.
The debug was full of these:
ICMP-Q:Dropped Not a candidate: Remote Port Blocked L3If:Vlan248 L2If:GigabitEthernet1/0/17 DI:0xB4, LT:7, Vlan:248 SrcGPN:17, SrcGID:17, ACLLogIdx:0x0, MacDA:001a.a1c4.1cd2, MacSA: 0013.192c.bb80 IP_SA:5.1.1.10
[Code].....
View 2 Replies
View Related
Aug 7, 2011
Is it possible to have a WS-C3750G-12S-S and a WS-C3750X-24T-L in the same stack, if so do they need to both be running the same software version/IOS.
View 6 Replies
View Related
Sep 16, 2012
i m using a stack in between below mentioned switch but we are facing a problem at 3750E on port is down.
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
1 28 WS-C3750G-24TS-1U 12.2(50)SE2 C3750-IPBASEK9-M
2 28 WS-C3750G-24TS-1U 12.2(50)SE5 C3750-IPBASE-M
* 3 30 WS-C3750E-24TD 12.2(50)SE2 C3750E-UNIVERSALK9-M
[Code]...
Is there any IOS or any H/W issue???
View 8 Replies
View Related
Sep 11, 2012
I decided to see how my WiFi would stack up against my Cat6 ethernet cable. I subscribe to Comcast's 20 mb/s connection.
View 4 Replies
View Related
Jul 26, 2011
I am trying to use Ciscoworks LMS3.2 with RME 4.3.1. to upgrade many, many Cat3750x stacks we have laying around. The problem I am having is that Ciscoworks downloads the new image to the Stack’s master switch only and not to all switches. When I reload the stack after the download, any switch could become the master. I already set up the priority to always have the same master, but the process is unreliable and more than once I ended up with another switch as a master. In any case if the master is not the switch with the new image, the stack will keep the old image as their running image and the switch with the newer image has problems joining the stack (after a while it downgrades and become stable)I know how to do it manually, but I was hoping Ciscoworks would be able to do this for me. It would make my life much easier.
View 1 Replies
View Related
Apr 16, 2013
We have a current 3-stack 3750 ( 48-P,48-TS & 3750v2-48PS ) running fine. There is a plan to introduce a fourth stack member ( 3750X-48P ) into this stack.as per cisco documentation, it suggests to use 3750X as master for a mixed stack. In this case, we will need to upgrade current other 3 stack switches to a latest version.,Can we do a no-downtime ios upgrade on the existing 3-switch stack?, when this upgrade is done, is there any way to have the new ios pushed down to all three stack members at the same time or do we need to each member upgrade seperately?, for adding the fourth member, is it acceptable if master is ruuning ver eg. 12.2(55) and all rest of the members run ver 12.2(53) ? will this create any issues and will stacking be successful.
View 5 Replies
View Related
Oct 30, 2012
I have 4 switches of 3750. I need toupgrade all the switches, but I can't to disconnect the stack cable.How I can to upgrade the version without to disconnect the stack cable?
View 2 Replies
View Related
Dec 10, 2012
I was thinking of upgrading the IOS of a number of c3750 stack (roughtly about 50-100 stacks around the country)...I would like to know is this feasible?
My CiscoWork NMS is connected with a low bandwidth (2Mbps) management link. I was thinking if I upgrade via CW2k, then RME will take "ages" to push the IOS to the stack, right? Is this feasbile for 100+ stack of switches?
View 5 Replies
View Related
Jun 28, 2012
Can I create lag betwen stack unit to increase speed between units ?? stack connection is only 1Gbit on ports 24/48 if posible lag link must be in trunk mode ?
View 4 Replies
View Related
Oct 4, 2011
I will be installing a new ASA 5510 firewall on our SIP vlan to separate our voice traffic from the rest of the traffic. I'm trying to decide whether or not I should go with an active/active setup or an active/standby. Any insight on the best way to set this up? This install is going in from scratch, and I am going to be connecting to a 3750 switch stack. Should I pair up a link from each switch to each 5510 using etherchannels? Should I use 8.3 or 8.4? Most of the docs I've been able to find say it depends on this, that, or the other.
View 2 Replies
View Related
Mar 8, 2012
I have 3750 stack with 4 switches.I am trying to make change some port to new VLAN, but switch 2 & 3 new change never works, the ports stick with old VLAN. Other two switches works as I expected on new changed VLAN.Tried to reboot, no progress.
#Show VLAN command confirmed the VLAN changes are made.
#show switch detail
Current
Switch# Role Mac Address Priority State
--------------------------------------------------------
1 Member 0019.e752.xxxx 1 Ready
2 Member 0015.f9bf.xxxx 1 Ready
[code]......
View 4 Replies
View Related
Oct 3, 2006
I am building a few 3750 stacks, I want to be able to poll/monitor each individual switch in the stack but as it only has 1 ip associated with the stack how can I do this. I am polling the uplink interfaces but as I only have uplinks on the top and bottom switch I am blind to a switch going down in the middle of the stack.
View 4 Replies
View Related
Nov 1, 2011
I have 3 SLM248G4S switches in a stack (SW1, SW2, and SW3), and want to pull one out and configure it as a stand alone.
If I just disconnect the stacking ports from SW3 and reconnect the bottom stack port from SW2 to the top one of SW1, the two switches continue to function together fine, but SW3 still seems to think it's part of the stack (still shows #3 on the LED screen) and doesn't work at all. I cannot even telnet into SW3.
View 3 Replies
View Related
May 9, 2011
I just inherited a network which has 7 switches (3750s) as a Stack. In there, there are 5 SVI (switch virtual interfaces) and in each of these VLANs, HSRP is configured.
Question:Is HSRP really needed in a Stack configuration?If so, what are the benefits?Can I simply clean-up the config and remove HSRP?
View 14 Replies
View Related
Nov 7, 2012
I have 2 3750x switches connected via a pair of stackwise cables, but I keep seeing error messages about the stack&switch ports going up and down,Performance wise, it seems to work, but I'd like to eliminate this message... Sometimes it will go hours without bouncing, sometimes it does it a few times a minute....
*Mar 4 12:56:57.903: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
*Mar 4 13:16:48.070: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 2 has changed to state UP
*Mar 4 13:16:49.093: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 2 has changed to state DOWN
*Mar 4 13:38:55.802: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state UP
*Mar 4 13:38:56.809: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
[code]...
View 4 Replies
View Related
Jul 15, 2012
I have to setup my first flex stack and wanted to make sure I do it right. I have the physical aspect of the stack down. From what I gathered I have to setup the master switch as the highest priority and then provision the other two switches. But I have configs on the other two switches, do I have to delete them? And do I have to setup individual ips for the two slave switches, because from what I saw the master switch is the only one with an ip address? The master switch is a poe 2960S-48LPS and the two other switches are 2960G-48TD
View 5 Replies
View Related
Apr 20, 2013
We'd had 5 switches in the stack and everything was ok. but then we connected a new 6th switch so I can see periodical short loosing packets. It happened on many hosts connected to these stack at different time. Cpu load is ok and no any errors in logs. Any others debugs?
(From my host)
ping -t 10.8.8.xx
[...]
Reply from 10.8.8.xx: bytes=32 time<1ms TTL=127
Request timeout
Request timeout
Reply from 10.8.8.xx: bytes=32 time<1ms TTL=127
[code]....
View 3 Replies
View Related
Jun 2, 2013
I wonder if i can make a stack with 3 SG500-28.
View 1 Replies
View Related
May 7, 2013
I'm trying to review a QoS setup, and I'd like to make sure I fully understand the current setup before I change anything. I'm seeing output drops on two different queue-thresholds, but not sure how packets are making it to one of the queues.
Switch Version
CORE#show ver
Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
System image file is "flash:/c3750e-universalk9-mz.150-2.SE/c3750e-universalk9-mz.150-2.SE.bin"
cisco WS-C3750X-24 (PowerPC405) processor (revision A0) with 262144K bytes of memory.
Switch Ports Model SW Version(code)
I can find queue4-threshold3 in the mappings, but how are packets getting mapped to queue2-threshold1? The priority queue is disabled for this interface, so I'm not sure how this queue is dropping packets, according to the maps nothing is mapped to 02-01.
View 3 Replies
View Related
Jun 10, 2012
I have a switch stack with three WS-C3750X-48 switches running 12.2(55)SE. Recently, stack member 3 went offline for a few minutes, after being online for over a year. A show version on member 3 reports that the system returned to ROM by power-on.
Stack member 3 shares a UPS with a router that did not lose power and all three stack members have stack power with four 350 WATT power supplies between the three of them. There are no crashinfo files on any of the switches, log files show the stack ports on the other switches going offline then switch 3 being removed from the stack.
Surveillance recordings show there was no one near the switch during the time and AAA accounting shows no clues. Is it possible the switch crashed without leaving a trace in the logs, a crashinfo file and report that it returned to ROM by power-on?
I've read before that loose stack cables can cause stack member reboots. Would such an event generate log messages other than the stack ports changing states to down?
View 6 Replies
View Related
Dec 6, 2011
I have two 3750s stacked and one 3750 standalone all in one data closet. The both have the same versions. I want to combine them to make one stack. How do I force the standalone to be the master? sw 1 priority XX(Higher then the existing stack)? Both the stack and the standalone have management addresses. Would it be ok to delete the stack ip address? That way, the standalone(master's address will be the only management address)?How should I connect the standalone 3750 to the stack? At present, the 3750 stack is connected via a cascade cable going from the stack 1 port of the top switch to the stack 2 port of the bottom switch.
View 19 Replies
View Related
Mar 7, 2013
This 3750X stack (3 members) has some 100% cpu spikes. Is this bad enough to start tracking down the cause(s) or is this somewhat typical and not a reason for concern? I just took this reading. How can you detemine when the 100% and 80% spikes occurred?
2222233333333332222222222444442222222223333322222222222222
7777733333333338888888888000007777777770000077777888887777
100
[Code].....
View 3 Replies
View Related