Cisco Infrastructure :: IOS For 4507R

Mar 24, 2013

I need to use:
 
track 1 ip sla 1 reachability
 
In my 4507R core switch. Need to know which IOS should I use for this command as now I am using
 
cat4500-entservices-mz.122-46.SG.bin
 
In this when I am using

(config)#track 1 ip ?
  route  IP route

View 1 Replies


ADVERTISEMENT

Cisco WAN :: 4507R With Sup6-E QoS?

Feb 11, 2012

I'm trying to use a Sup6-E to do some intelligent shaping. I'm getting an error and I think its because of the architecture of the 4500 QoS. Most likely this type of QoS is not supported so how to implement this QoS policy.
  
!
class-map match-any PRIORITY-QUEUE
match dscp ef
match dscp cs5
match dscp cs4
!
class-map match-any CONTROL-MGMT-QUEUE

[code]....

View 1 Replies View Related

Cisco :: 4507R-E - Cannot RME To Manage It

Jul 14, 2011

We have just replaced a 4507R for a 4507R-E but I can't RME to manage it. I also can't get Cisco View to work. We appear to have packages installed (see attachments).
 
Is there anything I can do to troubleshoot?

View 3 Replies View Related

Cisco :: 4507R-E And RME Config Change Report?

Aug 22, 2011

We have a new 4507R-E Switch which RME keeps reporting as "CONFIG_CHANGE" each evening. When you click to see the change, the only thing that has changes is the "ntp clock-period".
 
However, we have configured "ntp clock-period" as an exclude command in RME Config Managment.

View 1 Replies View Related

Cisco :: Catalyst 4507R Plus E Can't Extract Inventory From LMS 4.1

Feb 20, 2012

We have 694 units Cisco Catalyst 4507R plus E swithes accross the network. LMS 4.1 can discover it no problem however, i cannot extract inventory information for these switches. I get the this "Number of devices that do not have inventory collected data" on the report.installed System image file is "bootflash:cat4500e-entservicesk9-mz.150-2.SG1.bin"
 
 i saw this supported version:
 
150-1.XO (or) 03.01.00.SG <<--- should i have the exact image or higher version will do? [Inventory Config and Image Management]  

Reference: [URL]
 
 Is the image installed on my switches not supported? seems like I have higher version.

View 3 Replies View Related

Cisco WAN :: Inactive Ports On 4507R-2 Switch?

Nov 14, 2012

I'm having issues getting the ports g3/5 and g4/5 from inactive to notconnect.
 
I have tried the hw-module uplink select all in the global configuratio, but it's not working, getting a : % Invalid input detected at '^' marker. Message every time.
  
This what I have:
 
Power consumed by backplane : 40 Watts
Mod Ports Card Type                              Model              Serial No.
---+-----+--------------------------------------+------------------+-----------
1    48  10/100/1000BaseT (RJ45)                WS-X4548-GB-RJ45   JAE152101QK

[Code].....

View 2 Replies View Related

Cisco Switching/Routing :: Auto QoS On 4507R-E?

Mar 15, 2010

I have a 4507R-E chassis with Supervisor IV running IOS 12.2(50)SG.  I am trying to configure "auto qos voip trust" on some of the uplink ports.  When I try to configure it on a port that is in a channel group, I get the error "AutoQoS Error: AutoQoS can not be configured on member port(s) of a port-channel".  I have also tried configuring it on the channel interface, but it is not an available command under the channel interface.  Is there a way to do auto qos on the channel interfaces or their member ports or does it have to be configured manually?

View 12 Replies View Related

Cisco Switching/Routing :: 4507R - CPU Utilization 90%?

Dec 15, 2011

I am facing high CPU utilzation for cisco4507R,

sup:
WS-X4516-V
ios version:
cat4500-entservices-mz.122-54.SG.bin
!
show process cpu
CPU utilization for five seconds: 97%/1%; one minute: 97%; five minutes: 97%

[code]....

View 8 Replies View Related

Cisco :: LMS Cannot Display Image Switch 4507R+E

Aug 23, 2011

I installed LMS 4.0 succesfully, but  when i go to topology, can view all network, but the "AswitchA" Core 4507R+E be displayed as "?"

And it can not display this "AswitchA" into CISCO VIEW, display this messaje :
 
"Cannot find applicable device package for ... This error could be due to one of the following:

- The device package for this device type is not installed.
- Device support for this device type is not available.
- You are trying to open a component inside a device.

To correct the problem, either install a device package for the device type, or open the parent device to manage the component."

View 2 Replies View Related

Cisco Security :: 4507R - NAC L2 IEEE And IP Differences

May 3, 2011

My customer is having Cisco 4507R switch with IOS version 122.31-SG1 which deosnt supports NAC - L2 IEEE 802.1x but supports NAC - L2 IP.What is the difference between these features and which features is required for proper authentication and posture assesment.

View 1 Replies View Related

Cisco WAN :: 7204VXR / 4507R-E - Redundancy To Single ISP?

Dec 12, 2011

what I have are 2 x 7204VXR (Gateways), 1 x 4507R-E (Coreswitch), and our ISP have 7609.Got some issues with redundancy with our ISP.
 
                                        7609
                                        I     I
                                        I     I
                               7204-A    7204-B
                                    |             |
                                    |    vrrp   |
                                    |             |
                                    -4507R-E-
                                          |
                                          |
                               internal network
 
Both outside interfaces of 7204 gateways are connecting to 7609 with different public ip block.I used VRRP for my internal nework and failover have been tested working.Even tried to remove link of 7204-A and 7609, the failover works perfect.But somehow we're facing a problem:

- If I shutdown/ remove the link between my 4507R-E and 7204-A (primary gw_higher vrrp priority), vrrp redundancy/failover still works but internal network's internet connection goes down.
 
I asked our ISP and the route commands they put in their 7609 are as of follows:
ip route 3.8.8.0 255.255.255.0 3.4.4.4 name TO CUSTOMER LINK 1
ip route 3.8.8.0 255.255.255.0 3.3.3.3 2 name TO CUSTOMER LINK 2
 
And if they're trying to use Reliable Static Routing Backup Using Object Tracking, the internal network's internet connections is intermittent....alternate 4 ping reply and 4 timeout.
 
Note: IP used are sample only

View 6 Replies View Related

Cisco Switching/Routing :: 4507R Switch SUP Cards

Apr 19, 2013

I have two types of 4507 switches

1. 4507R
2. 4507R-E
 
and SUP-V and SUP-6-E.So I want to test both SUP cards on both switches which SUP card support which switch?

View 1 Replies View Related

Cisco Switching/Routing :: Are Cat 4507R Supervisors Hot Swappable

Feb 19, 2013

I received an replacement supervisor from Cisco to swap out the failed standby supervisor.  I wanted to check if I can pull out the failed supervisor supervisor and insert the replacement supervisor while the switch is still on.  In other words, is it hot swappable?  Also, will this operation cause interruption of switching inside the 4507R switch?

View 6 Replies View Related

Cisco Switching/Routing :: Power Consumption On 4507R

Aug 2, 2010

We are planning for the office move and I need to estimate how much power we need to run a fully populated Cat4507R switch. The chassis include 2 Sups, one 6-port fiber line card, two 48-port Gig and two 48-port FastEthernet line cards. The switch also has redundant power supply (4200ACV 1400W). According to Cisco Power Calculator [URL], I need 49.5 amp 110-120V circuit. It seems to be too much higher than real world. How many 20amp circuit we would need when all the ports are fully utilized?

View 3 Replies View Related

Cisco Switching/Routing :: Upgrade On 4507R+E Single SUP?

Mar 3, 2013

how to upgrade firmware on 4507 6L-E Sup. There is only 1 Sup on the switch. is there any special requirement to update the firmware when switch not running on redundancy mode?
 
-core-1#show redundancy states   my state = 13 -ACTIVE peer state = 1  -DISABLED Mode = Simplex Unit = Primary Unit ID = 3
Redundancy Mode (Operational) = Stateful Switchover Redundancy Mode (Configured)  = Stateful SwitchoverRedundancy State = Non Redundant 
[Code] ......

View 1 Replies View Related

Cisco Switching/Routing :: 4507R Bootflash Memory

Dec 28, 2011

I have a bootflash in 4507R with the size of 60MB. I upgraded the ios from cat4500-ipbasek9-mz.122-37.SG1.bin (12.8MB Size) to cat4500-entservices-mz.122-37.SG1.bin (13.8 MB SIZE) and deleted the previous IOS.But previous IOS is still getting shown in sh bootflash: command. Furthermore,  dir bootflash: commands shows there is only one IOS , which is running. How I can free the space from bootflash , as I again have to upgrade the another new IOS ( of 16MB), which I tried through solarwinds tftp and couldn't upload successfully because of its limitation. Now, If I try to upload the new IOS through FTP, it gives me memory space error. How I can free the space captured by old IOS and also how I can delete the 3rd unknown entry of IOS (shown below output of commands)?

View 4 Replies View Related

Cisco WAN :: 4507R+E No Longer Specify Encapsulation Type On Trunk

Feb 19, 2012

I am looking at upgrading our 4503 to the 4507R+E. Just going through the configurations and a couple of commands seemed to have dropped off this release.
 
1. I can no longer specify encapsulation type on a trunk. Does the 4507 auto sence encapsulation and apply it dynamically?
2. I had dscp trust configuration as below on the 4503, whats the equivilent on the 4507?

View 3 Replies View Related

Cisco Switching/Routing :: Config Register On 4507R

Jun 5, 2012

Need to confirm on 4507 R switch should i set config reg to 0x2102  or 0x2101?

View 4 Replies View Related

Cisco WAN :: Core Switch 4507R Suddenly Restarted

Apr 20, 2012

My CORE Switch 4507R Suddenly restarted (Powe is good) , and gets the business down for 30 Mts,my boss came to me and asks why it has restarted , what is the root cause of this restart, i dont have any syslog or NMS enabled in my  network to be informed

View 6 Replies View Related

Cisco Switching/Routing :: Is 4507R FAN Tray Hot Swappable

May 27, 2012

We have a Cisco 4507R switch with sup V. This switch fan tray has partial problem .No light in fan tray. We got another fan tray. Can any one tells me is it hot swappable?

What procedure should I flow without any interruption our live network?

View 4 Replies View Related

Cisco WAN :: DHCP Configuration On Core Switch 4507R

Jul 9, 2011

DHCP configuration on CISCO core switch 4507R switch.With one vlan and multipul vlan both configuration using any ip address range.

View 3 Replies View Related

Cisco Switching/Routing :: Getting 4507R+E FE0 Management Port?

Nov 1, 2012

Is there some kind of trick to getting the fastethernet 0 management port to come up? My adjacent switch is up/up, but fe0 is down/down. I dont' see how this could be possible. I am getting all my info remotely, but I am pretty sure it's wired up correctly.

View 2 Replies View Related

Cisco WAN :: Create QOS Profile On 4507R With SupIVs Running 12.2(54)?

Oct 14, 2011

I have a requirement to guarantee 100Mb of bandwidth over my WAN for a particular protocol.I've noticed on the 4507R (running 12.2(54)) that I am unable to config a class-map with "match port" (my protocol is not listed so i cant use match protocol").
 
So instead I've created an ACL with the source of the traffic I wish to guarantee.  Next, I've created a policy-map, only to find that I am unable to specify "bandwidth".
 
tell me how I could create a QOS profile, on a 4507R with SupIVs running 12.2(54), in order to guarantee 100Mb to a specific subnet (or vlan, or ideally specific protocol).

View 1 Replies View Related

Cisco Switching/Routing :: 4507R Classic Chassis With Sup 6L-E

Jan 4, 2012

Configuring a 4507R classic chassis with redundant Sup 6L-E?  TAC told me the Supervisor 6LE was only supported on the 4507R+E or 4507R-E chassis but I have found in Cisco documentation several places that indicate that the Sup 6LE is supported in the classic chassis.

View 1 Replies View Related

Cisco Switching/Routing :: 4507R-E - Configuration For VLans

Mar 4, 2013

I'm unable to pass the required vlans networks to my firewall I have different vlans configured for each floor of the building, All these floors have Nortel switches which are connected to the core switch through fiber link.

I have a Cisco 4507R-E core switch. Config for the core switch below: what else has to be done in order to pass the vlans to my firewalls. 
 
Current configuration : 18527 bytes
hostname HQ_Prim_Core_Swt
boot-start-marker
boot-end-marker
enable secret 5 $1$xj2Z$TmV9chRtQWCuXYMsCtBVW/
enable password 7 13521317135C0729
[code]....

View 5 Replies View Related

Cisco Switching/Routing :: Multicast Hogging 4507R

May 30, 2013

i tried a stab and multicasting a FOG image to 4 machines the other day, and i had experienced odd and strange issues.
 
here is what i encountered:,100% cpu usage on our core switch,core4507#sh processes cpu hist
 
    9999999999999999999999999999999999999999999999999999999999
    7777888888888877777888888888888887777788888888888888888887
100 **********************************************************
[Code]...
 
pinging the SVI on the core and or pinging on the core to other devices resulted in MAJOR latencies, packet loss due to the cpu usage, etc.... no other network operations were affected, i could communicate with the rest of the network, and under 1-2ms latencies. i noticed it due to my opsview server flagging the core as down (SNMP OID's wouldnt return a value) 
 
it lasted the whole time i was multicasting, i kept a close eye on it.  i highly considered canceling my job, but everything ran smooth.when i looked at the cpu sorted history i saw 2 processes, IP Input, and cat4k mgmnt hipri 

View 1 Replies View Related

Cisco WAN :: New Module 4548 Is Not Working (Fail) In 4507R+E Chassis

Jul 19, 2012

I am experiencing 1 4548 module fail  issue with one of my customer place. unfortunately they are having only 1 4507R+E chassis and 1 4548 module.  however i have replaced the module 4548 and getting the same error even after replacing ...!! but they are having redudant X45-SUP6L-E tried by removing each at one time with no luck. [code]

View 3 Replies View Related

Cisco Switching/Routing :: Configuring 4507R For LACP And Trunking?

Apr 3, 2008

We're trying to configure our Cisco 4507 (Supervisor Engine IV) to allow a new Dell server with a pair of Broadcom 5708 GigE NIC's to aggregate its NIC's to give us a 2gbps link to the switch.
 
So far we seem to have got the team and LACP up and enabled, but the adaptor that the Broadcom Admin Util creates for the team is only showing a 1gbps connection where I would have expected it to show as 2gbps.
 
The individual NICs show as connected at 1gbps. We're not Cisco experts so are struggling on how to get the 2 NICs to aggregate.
 
On the server side we've done nothing other than create a team using 802.3ad LINk Aggregation using LACP.
 
This is what I think the relevent output from "sho conf" is, more available if needed.
 
version 12.2
boot system flash bootflash:cat4000-i9s-mz.122-18.EW1.bin
!
interface Port-channel2

[Code].....

View 3 Replies View Related

Cisco Switching/Routing :: Shutdown 4507r-e And Just Swap Out Blade?

Apr 2, 2012

If i replace a card of the same type in the same slot will I lose the configuration for that card or does it live in the backplane of the device?Is there any special command I need to run to replace the card or can i shutdown the 4507r-e and just swap out the blade?

View 3 Replies View Related

Cisco Switching/Routing :: 4507r / Format Of Flash Caused 100% CPU?

Jul 21, 2012

I had an issue today on a 4507r today where when I formatted the compact flash in slot0: (512mb) it caused the CPU to spike to 100% this took about 1.5 hours and did not cause adjacency loss or any thing, but was worrisome. This was a sup IV  is this normal and should u let it complete like I did?  Also when I copied the os to it from boot flash it caused the same behavior.   I have done this a bunch in 6500 sup 720 without this issue?

View 3 Replies View Related

Cisco Switching/Routing :: 4507R+E / SSO Not Available As Redundancy Mode Option

Oct 31, 2012

Why rpr is the only available redundancy mode option available to me.  I'm running a 4507R+E with twin SUP7-E's.
 
Abbreviated show ver Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.03.01.SG RELEASE SOFTWARE (fc2)Technical Support: [URL]/techsupportCopyright (c) 1986-2012 by Cisco Systems, Inc.Compiled Sun 26-Aug-12 13:45 by prod_rel_team
ROM: 15.0(1r)SG2gp08401 uptime is 6 weeks, 6 days, 4 hours, 59 minutesUptime for this control processor is 6 weeks, 3 days, 2 hours, 21 minutesSystem returned to ROM by RPR SwitchoverSystem image file is "bootflash:/cat4500e-universalk9.SPA.03.03.01.SG.151-1.SG1.bin"Jawa Revision 7, Snowtrooper Revision 0x0.0x1C

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: Secon SUP Engine On 4507R Switch?

Mar 8, 2012

I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
 
SWITCH-4507#sh ver
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version
12.2(25)EWA8, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 24-Jan-07 15:28 by pwade

[code]....

View 4 Replies View Related

Cisco Switching/Routing :: 4507R-E How To Implement Same Configuration On New Switch

Feb 26, 2013

I'm in the process of upgrading my 4507R core to a new 4507R-E. The old switch has Sup IV engines (WS-X4515) running IOS 12.2(40)SG and the new switch has Sup 6L-E engines running 15.1(2)SG. I'm trying to "move" my configuration from the old switch to the new. Below shows the commands configured in the old switch. I'm trying to determine how to implement the same configuration on the new switch since these commands are no longer available.

View 2 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved