We have just replaced a 4507R for a 4507R-E but I can't RME to manage it. I also can't get Cisco View to work. We appear to have packages installed (see attachments).
I'm trying to use a Sup6-E to do some intelligent shaping. I'm getting an error and I think its because of the architecture of the 4500 QoS. Most likely this type of QoS is not supported so how to implement this QoS policy.
! class-map match-any PRIORITY-QUEUE match dscp ef match dscp cs5 match dscp cs4 ! class-map match-any CONTROL-MGMT-QUEUE
Is it safe to manage an 891 router across the Internet using Cisco Configuration Professional 2.4? If so, a few pointers on enabling and configuring it. If not, I assume setting up a VPN to the router then using CCP across the VPN would be the preferred approach.
I have setup WCS logins to be managed by ACS 4.2 . I was looking over the docs and I appear to be missing something because I can't find any documentation on doing the same to the controllers. I did successfully lock myself out of the WiSM in the lab during some testing. I had to pull the plug on the lab ACS to allow local login.
We have a new 4507R-E Switch which RME keeps reporting as "CONFIG_CHANGE" each evening. When you click to see the change, the only thing that has changes is the "ntp clock-period".
However, we have configured "ntp clock-period" as an exclude command in RME Config Managment.
We have 694 units Cisco Catalyst 4507R plus E swithes accross the network. LMS 4.1 can discover it no problem however, i cannot extract inventory information for these switches. I get the this "Number of devices that do not have inventory collected data" on the report.installed System image file is "bootflash:cat4500e-entservicesk9-mz.150-2.SG1.bin"
i saw this supported version:
150-1.XO (or) 03.01.00.SG <<--- should i have the exact image or higher version will do? [Inventory Config and Image Management]
Reference: [URL]
Is the image installed on my switches not supported? seems like I have higher version.
I'm having issues getting the ports g3/5 and g4/5 from inactive to notconnect.
I have tried the hw-module uplink select all in the global configuratio, but it's not working, getting a : % Invalid input detected at '^' marker. Message every time.
This what I have:
Power consumed by backplane : 40 Watts Mod Ports Card Type Model Serial No. ---+-----+--------------------------------------+------------------+----------- 1 48 10/100/1000BaseT (RJ45) WS-X4548-GB-RJ45 JAE152101QK
I have a 4507R-E chassis with Supervisor IV running IOS 12.2(50)SG. I am trying to configure "auto qos voip trust" on some of the uplink ports. When I try to configure it on a port that is in a channel group, I get the error "AutoQoS Error: AutoQoS can not be configured on member port(s) of a port-channel". I have also tried configuring it on the channel interface, but it is not an available command under the channel interface. Is there a way to do auto qos on the channel interfaces or their member ports or does it have to be configured manually?
sup: WS-X4516-V ios version: cat4500-entservices-mz.122-54.SG.bin ! show process cpu CPU utilization for five seconds: 97%/1%; one minute: 97%; five minutes: 97%
I installed LMS 4.0 succesfully, but when i go to topology, can view all network, but the "AswitchA" Core 4507R+E be displayed as "?"
And it can not display this "AswitchA" into CISCO VIEW, display this messaje :
"Cannot find applicable device package for ... This error could be due to one of the following:
- The device package for this device type is not installed. - Device support for this device type is not available. - You are trying to open a component inside a device.
To correct the problem, either install a device package for the device type, or open the parent device to manage the component."
My customer is having Cisco 4507R switch with IOS version 122.31-SG1 which deosnt supports NAC - L2 IEEE 802.1x but supports NAC - L2 IP.What is the difference between these features and which features is required for proper authentication and posture assesment.
what I have are 2 x 7204VXR (Gateways), 1 x 4507R-E (Coreswitch), and our ISP have 7609.Got some issues with redundancy with our ISP.
7609 I I I I 7204-A 7204-B | | | vrrp | | | -4507R-E- | | internal network
Both outside interfaces of 7204 gateways are connecting to 7609 with different public ip block.I used VRRP for my internal nework and failover have been tested working.Even tried to remove link of 7204-A and 7609, the failover works perfect.But somehow we're facing a problem:
- If I shutdown/ remove the link between my 4507R-E and 7204-A (primary gw_higher vrrp priority), vrrp redundancy/failover still works but internal network's internet connection goes down.
I asked our ISP and the route commands they put in their 7609 are as of follows: ip route 3.8.8.0 255.255.255.0 3.4.4.4 name TO CUSTOMER LINK 1 ip route 3.8.8.0 255.255.255.0 3.3.3.3 2 name TO CUSTOMER LINK 2
And if they're trying to use Reliable Static Routing Backup Using Object Tracking, the internal network's internet connections is intermittent....alternate 4 ping reply and 4 timeout.
Is-it possible to manage Cisco phone by web interface? (Manage transfertdiversion... of IP phone)When i go to http://ip_cisco7961 and i give permissions in settings of user (web Access: Enabled)I have only information in read only.
is it possible to manage a air-ap1262n with a controller like wlc 5500 or wlc 2500? the official cisco support could not answer me this question for sure. i have found this old guide to upgrade ap´s to lap´s, but there is hothing about the 1260 in it. [URL]
i am a little bit confused!
the cisco documents tells: "at_a_glance_c45-636090.pdf"
A wireless network with standalone access points offers a low-cost, entry-level solution that does not require a controller. It is ideal for small-scale networks with less than 20 access points, and offers base-level wireless functionality with the flexibility to scale and add services over time by adding a controller.
I would like to as you that i have swiches 2960 (10Unit) and switches 3560 ( 3 unit) and router 2821 ( 1 unite) and AP( 10 unit).So do you know software can manage all those product? Like monitor switch up or down, manage configure, check performance.
Setting up SNMP on my Cisco AP's (1242AG Lightweight). How do I manage these via SNMP? It doesn't appear there is any settings within each AP for SNMP but only on the 4400 controller. What I am trying to do is setup Solarwinds Alerts, so when an AP goes down, I get notified of it. How or where this gets setup on the 4400 or the AP. I'm guessing there is something probably on the 4400 that I setup.
I received an replacement supervisor from Cisco to swap out the failed standby supervisor. I wanted to check if I can pull out the failed supervisor supervisor and insert the replacement supervisor while the switch is still on. In other words, is it hot swappable? Also, will this operation cause interruption of switching inside the 4507R switch?
We are planning for the office move and I need to estimate how much power we need to run a fully populated Cat4507R switch. The chassis include 2 Sups, one 6-port fiber line card, two 48-port Gig and two 48-port FastEthernet line cards. The switch also has redundant power supply (4200ACV 1400W). According to Cisco Power Calculator [URL], I need 49.5 amp 110-120V circuit. It seems to be too much higher than real world. How many 20amp circuit we would need when all the ports are fully utilized?
how to upgrade firmware on 4507 6L-E Sup. There is only 1 Sup on the switch. is there any special requirement to update the firmware when switch not running on redundancy mode?
-core-1#show redundancy states my state = 13 -ACTIVE peer state = 1 -DISABLED Mode = Simplex Unit = Primary Unit ID = 3 Redundancy Mode (Operational) = Stateful Switchover Redundancy Mode (Configured) = Stateful SwitchoverRedundancy State = Non Redundant [Code] ......
I have a bootflash in 4507R with the size of 60MB. I upgraded the ios from cat4500-ipbasek9-mz.122-37.SG1.bin (12.8MB Size) to cat4500-entservices-mz.122-37.SG1.bin (13.8 MB SIZE) and deleted the previous IOS.But previous IOS is still getting shown in sh bootflash: command. Furthermore, dir bootflash: commands shows there is only one IOS , which is running. How I can free the space from bootflash , as I again have to upgrade the another new IOS ( of 16MB), which I tried through solarwinds tftp and couldn't upload successfully because of its limitation. Now, If I try to upload the new IOS through FTP, it gives me memory space error. How I can free the space captured by old IOS and also how I can delete the 3rd unknown entry of IOS (shown below output of commands)?
I am looking at upgrading our 4503 to the 4507R+E. Just going through the configurations and a couple of commands seemed to have dropped off this release.
1. I can no longer specify encapsulation type on a trunk. Does the 4507 auto sence encapsulation and apply it dynamically? 2. I had dscp trust configuration as below on the 4503, whats the equivilent on the 4507?
My CORE Switch 4507R Suddenly restarted (Powe is good) , and gets the business down for 30 Mts,my boss came to me and asks why it has restarted , what is the root cause of this restart, i dont have any syslog or NMS enabled in my network to be informed
We have a Cisco 4507R switch with sup V. This switch fan tray has partial problem .No light in fan tray. We got another fan tray. Can any one tells me is it hot swappable?
What procedure should I flow without any interruption our live network?
Is there some kind of trick to getting the fastethernet 0 management port to come up? My adjacent switch is up/up, but fe0 is down/down. I dont' see how this could be possible. I am getting all my info remotely, but I am pretty sure it's wired up correctly.
I have a requirement to guarantee 100Mb of bandwidth over my WAN for a particular protocol.I've noticed on the 4507R (running 12.2(54)) that I am unable to config a class-map with "match port" (my protocol is not listed so i cant use match protocol").
So instead I've created an ACL with the source of the traffic I wish to guarantee. Next, I've created a policy-map, only to find that I am unable to specify "bandwidth".
tell me how I could create a QOS profile, on a 4507R with SupIVs running 12.2(54), in order to guarantee 100Mb to a specific subnet (or vlan, or ideally specific protocol).
Configuring a 4507R classic chassis with redundant Sup 6L-E? TAC told me the Supervisor 6LE was only supported on the 4507R+E or 4507R-E chassis but I have found in Cisco documentation several places that indicate that the Sup 6LE is supported in the classic chassis.
I'm unable to pass the required vlans networks to my firewall I have different vlans configured for each floor of the building, All these floors have Nortel switches which are connected to the core switch through fiber link.