Cisco Infrastructure :: Catalyst 4006 - Enable Http Login To Switch?
Apr 12, 2005Is it possible to enable login by http (web interface) to catalyst 4006 switch with WS-C4006 Software, Version NmpSW: 6.3(5) ?
View 21 RepliesIs it possible to enable login by http (web interface) to catalyst 4006 switch with WS-C4006 Software, Version NmpSW: 6.3(5) ?
View 21 RepliesI have a Catalyst 4006 with Supervisor II engine. I have 48 port 10/100/1000 blades installed in it for connection to my servers. I am having a lot of problems with performance when connecting servers that are using 100 MB NICs. The speed of the connection is really bad. I have attempted setting the ports and NICs to 100MB Full duplex instead of auto-detect, but still get the same results.
I also have a 10/100 quad-port card installed in a NetApp filer. All four ports are trunked together and connect to 4 ports in the Catalyst. The ports in the Catalyst are trunked using the Port Channel feature of the CatOS. When I look at the port statistics on 3 of the 4 ports from the quad-card, there are a ton of runts and errors (both transmit and receive). The 4th port is fine, no errors.
I have a Catalyst 4006 switch in production and a spare switch of same model. I have to quickly copy the configuration from production switch to spare switch (both L2 and L3 configurations) How do I do that?
View 6 Replies View RelatedI have been trying to get the http server enabled so I can access Cisco Network Assistant. I have my interfaces configured but for some reason the server in not running, port 80 is still closed. [code]
View 2 Replies View Relatedi have a problem with a 4006 switch, when the poer goes out and comesback, the switch doesn't boot, you have to get in the console and type boot, the config register is 0x102, i try to change it but it did not let me, said somethong like usage, what can i do to configure the booting automatically
View 1 Replies View RelatedMy existing 4006 chassis is using Supervisor III (WS-X4014). I have another 4506 chassis using Supervisor IV (WS-X4515) and a Net flow Services Card (WS-F4531) build on top of it.
I need Net flow Services Card in 4006, so can I just replace the Supervisor IV (WS-X4515) used in Cisco 4006? Is it compatible with 4006?
My switches is still operating but when i ping the switch, there isn't any reply. No icmp reply from catalyst 2950 switch
View 6 Replies View Relatedwe got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]
View 1 Replies View RelatedI have set up an ACL on my 3750 switch to deny icmp from PC A on our inside network to PC B on a different VLAN on our inside network using the following ACLs:
deny icmp host 10.1.17.15 host 10.3.10.4
deny icmp host 10.3.10.4 host 10.1.17.15
-- or --
deny icmp host 10.1.17.15 host 10.3.10.4 echo-replydeny icmp host 10.3.10.4 host 10.1.17.15 echo-reply
These ACLs belong to an access-list that also limits ip traffic to a few specific machines.When I try pinging from PC A I receive a reply message back from PC B. Shouldn't this configuration block any ICMP from PC A to PC B and from PC B to PC A? I would have expected the first ACL statement to block any packets associated with ICMP and when that didn't work I tried the second configuration.
In my ongoing project i need to monitor cisco 3750-X port status (uplink/downlink) i.e. whenever there is some problem at a specific port. I need to monitor it through an OPC server and right now what i am doing is as follows: i am using Kepserver and i have added SNMP driver in it for that purpose i am not a networking expert but what i have learnt till now is that SNMP agent (that resides in switch) delivers the status of MIBs to SNMP manager ( which in my case is kepserver (opc server)) for the above purpose i am adding IF-MIB to monitor OID 1.3.6.1.2.1.2.2.1.8 (which shows port statuses) but when i add that in OPC server then it indicated that this OID is not available in the Switch ( it might be disabled) so i need to ask if there is any way to enable OID's in a switch,
View 0 Replies View RelatedI have several 2960s and 3750s and two 6506 (ws-cac-3000w) recently move to new location The power outlet is the same ,but Volt is different current 2960/3750 use this(one phase 3 wire) 220v and new location change to (from 3 phase 4 wire -> one phase 220v)6506 current using(one phase 3 wire) and will be change to (from 3 phase 4 wire -> one phase 220v)
I had search doc about power supply /cable , only show support single phase 220 v ,but not description vlot between each wire !!Does new location power outlet suit for 2960/3750s power and 6500 ws-cac-3000w ?!? Do I need chane power outlet back to current using?
I have been facing High CPU Utilization issue with few of my Cisco 4006 Switches together from last one month. Out of which 1 switch issue sorted out auto after 2 days however the problem is still exists with rest 3 switches.They are 6-7 year old and having one SUP engine and other are switch port modules.
View 5 Replies View RelatedIn CLI we have users log in at priv 1 and use "enable" to increase privilege and do configurations. This allows "accounting" of command history. On the AIR-AP1121G-A-K9 (12.3(8)JED1) I cannot duplicate this for http login.
I can log in as a user at priv 1. When I try to go to a privileged link like "Security" I get prompted for a second login/pw. Nothing works here unless I have a second user defined at priv 15 and enter that login/pw. The problem is - that login/pw can be used to log in via http in the first place which bypasses accounting of the actual user. It also allows login to the CLI at priv 15 which I cannot permit.
username test1 secret 5 abcdxxx
username test2 privilege 15 secret 5 efghxxx
enable secret 5 ijklxxx(code)
how to enable inspect http on ASA 5510, so that URL information populate in the syslogs?
View 2 Replies View RelatedAny benefit to enable https with in the gui instead of using the default http?
View 1 Replies View RelatedI have upgraded NCS 1.1.1.24 to PI 1.2 lately. The installation process completed successfully.But now i am not able to log in to the GUI anymore as root. After entering the password all I get is a blank site (undefined).I get the same result with all known browsers. Rebooting or restarting NCS does not change anything.
View 12 Replies View Relatedhow can i access the backup SUP from telnet/console while it's in the standby state?
View 3 Replies View Relatedcisco WS-C6509-E Core switch with IOS "s72033-ipservicesk9_wan-mz.122-18.SXF11"
i have 2 question
Q.1 i want to upgrade this switch what is the latest IOS ver. supported by this module ?
Q.2 i need to enable http server on this switch when i run this comman it's accsebt but i cant get http work
I am unable to login to switch c3560 through Hostname but able to login through IP address. when i am putting the command : login authentication telnetpwd
getting the below message:
AAA: Warning authentication list "telnetpwd" is not defined for LOGIN.
how to enable RSTP in the switch (Let's say in 2950 switch).
Or do you have RSTP running in now-a-days switches?
We`re using a WLC 5508 with SW 7.2.103.0.The most things are working fine, but i have a problem with the web auth.
Setup:
- Max Concurrent Logins for a user name is set to 1
- Max-Login Ignore Identity Response is set to enable
- Web Authentication Type is set to customized
The Problem:
- the user "test" is logged in at device1 (working), the same user "test" try to login at device 2 (is not working, fine!) -> login is not accepted, WLC redirects to the INTERNAL Web Login Page.The problem is the redirect to the internal web login page after failed login. If i try to login with a not existing user, the redirect is working perfect to the customized web login.
I configured the below config in Routers it is working good , but when i do the same in SWITCH-2960 , i am getting a problem not able to login to enable mode ... i am getting the basic login only ....
Error msg : % Error in Authentication.
Need to be configured at TAFE Network Devices: Code...
We are facing an issue with the NAM3.Version: 5.1(2-patch4)
we can not login using the GUI. when we try to login we are getting the following warning:
Initializing database. Please wait until initialization process finishes.(see attachment)
we have rebooted the NAM3 module but the issue is not solved. the NAM3 module is running on 6500 Series Switch.(Cisco Catalyst 6500 Series Network Analysis Module (NAM-3)
Can we enable ssh on 3500 /3600 APs along with use radius for login authentication? idea here is to that ssh will provide another method to access the AP for troubleshooting purposes.I know with autonomous mode APs this should not be an issue but not sure with lightweight APs.
View 2 Replies View RelatedI want to configure a bsc network with a cisco 2901 router, but bstun commands are not enabled. I've already found a lot of tutorial about "How to configure bstun network" but none about how to enable it.
"show bstun", "show bsc", "bstun peer-name", etc. return "% Invalid input detected at '^' marker."
Here my "show version" :
Router#show version
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.1(4)M2, RE)
Technical Support: [URL]
Copyright (c) 1986-2011 by Cisco Systems, Inc.
[Code].....
We have a switch Cisco Catalyst 2900 Series XL Model WS-C2924-XL-EN. 8 MB DRAM 4 MB FLASH
I already tried the discussions regarding flash_init dir_flash: boot and the likes.
By the way, I already downloaded the IOS for our switch through Cisco Website. Settings are default through Hyper Terminal
Here's the thing:
Whenever I transfer the .bin file using XMODEM, it prompted an error "Transfer cancelled by remote computer"
i have few catalyst switches (2960, 3750) and i can't upload to them any files by tftp from my laptop, but i can download from them, and this bug don't appears on two routers.I was change tftp server, type of connection (wifi, cable), turn off firewall on win7, but no dice.
View 2 Replies View RelatedI need to do one Catalyst 5500 as a TFTP server.Can I do it?Is the catalyst available to be a tftp server?
View 4 Replies View Related I need to configure on a cisco catalyst 6509 two VACL. On cisco 6509 there are already two SPAN ports configured, there are problems configuring other two VACL?
These VACLs send traffic to a Traffic Analyzer (SIEM), there are particular configurations to facilitate the operation?
I have a customers Catalsyt 2950 switch come in for the configuration to be cleaned to factoy default, using the link below removed the customers banner and login information whitch worked
[URL]
When i restart the switch and enter Enable mode I'm prompted with the password which i used when following the link above,
I want to remove all passwords so when the switch is redeployed to the next site who ever the engineer is that is going to be reconfiguring the switch is able to access privlage mode with out the password promt.
I'm having trouble with a Cisco Catalyst 2950 Series Switch where by I'm following the procedure from Cisco's web site to remove the Banner and login information, url..
Each command is being accepted by the switch from following the information given within the help sheet above,the problem i have now is when i turn the power off then turn the switch back on I'm still getting the banner and login information even though i have follwed Cisco's help correctly.
lets you catalyst 3560 & 2960 remote login with a secure protocol
View 4 Replies View RelatedI want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)