Cisco Infrastructure :: 2960s / 3750s / 6506 - AC Power Outlet On Catalyst Switch

Apr 15, 2011

I have several 2960s and 3750s and two 6506 (ws-cac-3000w) recently move to new location The  power outlet is the same ,but Volt is different current 2960/3750 use this(one phase 3 wire) 220v and new location  change to (from 3 phase 4 wire -> one phase 220v)6506 current using(one phase 3 wire) and will be change to (from 3 phase 4 wire -> one phase 220v)

 I had search doc about power supply /cable ,  only show support single phase 220 v ,but not description  vlot between each wire !!Does new location power outlet suit for 2960/3750s power and 6500 ws-cac-3000w ?!? Do I need chane power outlet back to current using?

View 1 Replies


ADVERTISEMENT

Cisco :: Memory Utilization OID For Catalyst 6506 Switch

Dec 26, 2012

We have one Catalyst 6506 ( with WS-SUP720-3B, IOS is 12.2(18)SXF14 ) and one Catalyst 6509 ( with WS-SUP720-3B, IOS is 12.2(18)SXF17a ). We used WhatsUP to collect I/O & process memory utilization for both switches. The memory utilization for Catalyst 6509 was ok, but it seems not correct for Catalyst 6506 ( show proc memory displayed the total memory is 512MB, but the WhatsUP displayed only 64MB only )

View 1 Replies View Related

Internet Through Power Outlet?

Apr 7, 2011

I've been offered a position for an at home call center agent, one stipulation is that my office is upstairs from my router and I cant use wifi, so has anybody used that device where you plug an adapter into 2 of your electrical outlets, on one end you connect your router and the other you connect your computer, so anybody know of a good brand at a good price

View 1 Replies View Related

Cisco :: 2960S Catalyst Access Switch From VPN

Dec 10, 2012

I have a 2960S Catalyst switch in my LAN, with the firewall and the servers in the same VLAN (vlan 3).All the servers and the firewall are in the vlan 3 are in the "192.168.19.0/24" subnet, the firewall has the IP "192.168.19.1".I can land on the firewall with a VPN (192.168.130.0/24) which has a complete view on the subnet 19/24.I can access, manage and get SNMP information of the Catalyst from the servers but I can't do the same from the VPN.Is there some feature I need to enable on the switch in order to allow 192.168.130.0/24 to access it?

View 4 Replies View Related

Cisco Infrastructure :: Converting WS-C3560G Switch To DC Power?

Apr 15, 2013

What needs to be done to convert a WS-C3560G-24TS-E to DC power? 

View 2 Replies View Related

Cisco Infrastructure :: 3550 - Limiting Power Allocation To 15.4 W On Pre-POE Switch?

Jan 2, 2013

I'm using a Catlyst 3550 to supply power to a IP network surveliance camera.  By default, the predecesor to POE, Cisco Inline Power allocates 15.4 W of power to a port ... What is the process for reducing this power output?
 
"For an IEEE device, the switch always allocates 15.4 W to the port. The switch does not display the IEEE class type in the show power inline privileged EXEC command output. Instead, it displays n/a."

View 2 Replies View Related

Cisco Infrastructure :: No Icmp Reply From Catalyst 2950 Switch

Nov 15, 2005

My switches is still operating but when i ping the switch, there isn't any reply. No icmp reply from catalyst 2950 switch

View 6 Replies View Related

Cisco Infrastructure :: Blocking ICMP On Catalyst 3750 Switch Vlan?

Apr 7, 2011

I have set up an ACL on my 3750 switch to deny icmp from PC A  on our inside network to PC B on a different VLAN on our inside network using the following ACLs:
 
deny icmp host 10.1.17.15 host 10.3.10.4
deny icmp host 10.3.10.4 host 10.1.17.15
 
-- or --
 
deny icmp host 10.1.17.15 host 10.3.10.4 echo-replydeny icmp host 10.3.10.4 host 10.1.17.15 echo-reply

These ACLs belong to an access-list that also limits ip traffic to a few specific machines.When I try pinging from PC A I receive a reply message back from PC B. Shouldn't this configuration block any ICMP from PC A to PC B and from PC B to PC A? I would have expected the first ACL statement to block any packets associated with ICMP and when that didn't work I tried the second configuration.

View 6 Replies View Related

Cisco Infrastructure :: Catalyst 4006 - Enable Http Login To Switch?

Apr 12, 2005

Is it possible to enable login by http (web interface) to catalyst 4006 switch with WS-C4006 Software, Version NmpSW: 6.3(5) ?

View 21 Replies View Related

Cisco :: Catalyst 3560s / 3750s - EEM And TCL Script To Disable Inactive Ports

May 4, 2013

I've browsed around to the other  support strings to make sure I didn't miss anything, but I can't seem to  get this to work.  I have the latest sl_suspend_ports.tcl and  tm_suspend_ports.tcl created by Joseph Clarke from strings that verified they worked as planned.   Here are the commands I issued to register the scripts -
 
 
Directory of flash:/policies/ 
9  -rwx        3101   May 3 2013 07:58:03 +00:00  sl_suspend_ports.tcl
10  -rwx        4669   May 3 2013 07:58:44 +00:00  tm_suspend_ports.tcl
 conf t
event manager directory user policy flash:/policies
event manager policy sl_suspend_ports.tcl
event manager environment suspend_ports_days 1

[code].....
 
It doesn't appear to work though.  Essentially, we have a  need to make sure all computers are always on and all ports not active  for >24 hours to be shutdown and moved to a designated vlan (I added  the 'lappend' statement to the script to specify the additional command of assigning the vlan) I'm running 12.2(55)SE7 on Catalyst 3560s and 3750sIs there a way to manually run the script?  Did I miss anything in the configuration?

View 19 Replies View Related

Cisco Infrastructure :: 6506 CatOS Unable To Bootup

Nov 29, 2011

I have a 6506 with SUP1, no MSFC running CatOS.
 
Module 1: Removed
Module 2: WS-X6K-SUP1A-2GE
Module 3: WS-X6348
Module 4: WS-X6348
Module 5: WS-X6408A-GBIC
Module 6: WS-X6408A-GBIC
 
However, it doesn't seems to be able to bootup properly. Could this be an hardware issue? What should I do?

View 5 Replies View Related

Cisco Infrastructure :: 6506 To N7K Some Device Change Its IP Address Configuration

Jul 25, 2012

we just replace 6500 with N7K, after migration there're some device (server,pc,printer) change its ip address configuration (subnet and gateway) by it self. can N7K did it?

View 6 Replies View Related

Cisco WAN :: 3750s / Switch Stack Or HSRP?

May 9, 2011

I just inherited a network which has 7 switches (3750s) as a Stack. In there, there are 5 SVI (switch virtual interfaces) and in each of these VLANs, HSRP is configured.
 
Question:Is HSRP really needed in a Stack configuration?If so, what are the benefits?Can I simply clean-up the config and remove HSRP? 

View 14 Replies View Related

Cisco Switching/Routing :: 10 Gbase-T Module For Catalyst 6506

Sep 2, 2012

i want to know if 1port of the 16 10Gbase-t Module (WS-X6716-10T-3C) for the Catalyst 6500E Series, can be connected to a 1Gbase Port of a 2900 ISR Routers, are they gonig to work at 1Gbps or, simply, they are not compatible?
 
If it is true, can i create a 4ports etherchannel between them? of course using the 16 1Gbase-T switch module on the Router.

View 7 Replies View Related

Cisco Switching/Routing :: Catalyst 6506 Vlan-based Qos Configuration?

Feb 12, 2012

I was unable to configure vlan-based qos on Cisco IOS Software, s72033_rp Software (s72033_rp-IPSERVICESK9-M), Version 12.2(33)SXH6, RELEASE SOFTWARE (fc1) Seems to me my configuration is not working. Here is the output of the interface:
 
sh int G1/6 | i rate
Queueing strategy: fifo
30 second input rate 25231000 bits/sec, 4282 packets/sec
30 second output rate 46940000 bits/sec, 9257 packets/sec
 
And here is my configuration:
 
interface Vlan3
ip address 192.168.1.1 255.255.252.0
service-policy input TEST_IN_PMAP
service-policy output TEST_OUT_PMAP

[code]....

Why I can't see matches in ACLs? I've double checked the direction and seems to me it is correct. I can't see matches even I configure something like this:

10 permit ip host 192.168.1.168 any 
20 permit ip any host 192.168.1.168

Why my output rate is higher than 30M? Is it bacause there is no matching traffic here in ACLs? I'm absolutely shure that this host with such ip connected to this interface:

#sh arp | i 192.168.1.168
Internet  192.168.1.168           0   feed.beef.f00d  ARPA   Vlan3
#sh mac address-table |  i feed.beef.f00d
*    3  feed.beef.f00d   dynamic  Yes          0   Gi1/6

View 9 Replies View Related

Cisco Switching/Routing :: Multicast Traffic Not Forwarded On Catalyst 6506 VSS Supervisor

Nov 30, 2009

I have two Catalyst 6506 in VSS mode with VS-S720-10G running 12.2(33)SXI1 IP SERVICES.I have two firewalls that communicate on to the other through a dedicated VLAN created on Catalyst 6506.
 
One firewall is able to ping the other one on this dedicated VLAN but if I send multicast traffic from firewall-1 I didn't receive it on firewall-2.I found a bug related to multicast issues on Cisco WS-C6509-E with VS-S720-10G. The bug ID is CSCtc59038.

View 9 Replies View Related

Cisco Switching/Routing :: Catalyst 6506 And 10 GB 16 Port Fiber Module Compatibility

Sep 4, 2012

We have a core switch with the following ios and supervisor engine. Can we add a16 port LR (x2)or  LRM(X2)  ON  the core switch?if not what modifications has to be done?if an ios upgrade is necessary is it a costly affair?At present we have two 1gb up link modules in single and multimode fiber .
 
#sh moduleMod Ports Card Type  Model  Serial No.--- ----- -------------------------------------- ------------------ -----------  1   16  SFM-capable 16 port 1000mb GBIC        WS-X6516A-GBIC     SAL0803T308  2   48  SFM-capable 48 port 10/100/1000mb RJ45 WS-X6548-GE-TX     SAD07500600  5    5  Supervisor Engine 720 10GE (Active)    VS-S720-10G        SAL1439UMZK
#sh versionCisco IOS Software, s72033_rp Software (s72033_rp-IPBASE-M), Version 12.2(33)SXI4a, RELEASE SOFTWARE (fc2)Technical Support: [URL] Copyright (c) 1986-2010 by Cisco Systems, Inc.Compiled Fri 16-Jul-10 19:51 by prod_rel_team
ROM: System Bootstrap, Version 12.2(17r)SX7, RELEASE SOFTWARE (fc1) uptime is 1 year, 27 weeks, 4 days, 23 hours, 30 minutesUptime for this control processor is 1 year, 27 weeks, 4 days, 22 hours, 58 minutes(code)

View 6 Replies View Related

Cisco Infrastructure :: 2960S Upgrading A Customer Network

Mar 9, 2013

We are upgrading a customer network and have found that users of a particular application [which is very bursty/bandwidth hungry] have experienced a marked performance drop. I see lots of output drops on the interfaces. This is only happening on 2960S-48 the rest of the users on 2960PSTL [all PoE] are not having nearly as bad a time.I have tried various QoS configs with little success. I have seen on some other blogs that the 2960S has less buffers than the rest of the family.
 
Removing QoS or upping the users to 1Gb cures the performance problem.

View 6 Replies View Related

Cisco Infrastructure :: 2960S-48FPD - ROMmon Not Responding To Keystrokes?

May 23, 2013

I have a Cisco 2960S-48FPD that someone was trying to do an upgrade, loaded c2960-lanbasek9-mz.150-2.SE2.bin instead of c2960-universalk9-mz.150-2.SE2.bin.  To try and fix it they deleted both but before they could put the proper ios on, another person dropped power.  Now the switch will boot into rommon, HOWEVER it won't respond to any keystrokes.  It's stuck at "..... flash_init boot " and the switch: prompt.  I have tried using both putty and SecureCRT, the settings are correct, the usb-serial works on another c2960S.  I can read the output when it goes into rommon so it's not a baud rate issue.

View 8 Replies View Related

Cisco :: IP SLA Responder On Catalyst 2960S Stacked?

Oct 19, 2011

I have a pair of switches stacked:
 
Switch Ports Model                          SW Version          SW Image
------     -----     -----                             ----------                 ----------
     1    52      WS-C2960S-48FPS-L  15.0(1)SE             C2960S-UNIVERSALK9-M
*    2    52      WS-C2960S-48FPS-L  15.0(1)SE             C2960S-UNIVERSALK9-M
 
When I try to enable ip sla responder on the stack I get: 
 
%SYS-3-HARIKARI: Process IP SLAs Responder top-level routine exited
 
I have been able to find a bug in the toolkit. Should ip sla responder be supported on the stack as above?

View 6 Replies View Related

Cisco :: Catalyst 2960S Series Switches Supported In LMS 2.6

Jul 25, 2011

I have a CiscoWorks LMS 2.6 and i would like to know if the new Switches Catalyst 2960-S Series are supported with this LMS version?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S IOS 15.0.2 IPv6 Don't Work

Aug 8, 2012

Just I have upgraded some 2960S to IOS 15.0(2)SE from a IOS 15.0(1)SE3 and the catalyst don't switch any IPv6 traffic. Don't work any RA and also don't work any unicast IPv6 traffic from any interface. I can see some references to IPv6 changes in the FHS (First Hop Security) in the Release Notes, but no any reference to changes in the configuration.
 
The switches don't have any IPv6 specific configuration and the sdm is the default templata. Returning to 15.0(1)SE3 everything work ok.
 
On Catalyst 2960, and 3560E this IOS version seem to work fine with IPv6.

View 1 Replies View Related

Cisco AAA/Identity/Nac :: Configuring 802.1x Authentication On ACS 5.1.0.44 / Catalyst 2960S Switches?

Mar 22, 2012

configuring 802.1x authentication on ACS 5.1.0.44 & Catalyst 2960S switches.All the documents i have found seem to have incorrect screen shots or missing steps.I have found a doc external to Cisco [URL]however this just hangs when attempting to complete the task in figure G.The other docs are for configuring IBNS & assume that 802.1x is already configured.

View 1 Replies View Related

Cisco Switching/Routing :: Upgrade Catalyst 2960S And 3560x

Jun 20, 2012

i want upgrade my catalyst 2960S and 3560x at midnight, but i am worried about config loss.  If i upgrade my switch throught web interface, will need I reconfigure the switch?

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S Stack Required

Dec 1, 2010

I have a new problem with Catalyst 2960S. We have four switch in a stack and now I get the message:
 
“%PLATFORM_RPC-3-MSG_THROTTLED: RPC Msg Dropped by throttle mechanism: type 37, class 14, max_msg 32, total throttled 73968 (hostname1-2)”
 
Traceback= 13A686C 160862C 160E0B4 15E2088 184FD48 18467B8
 
sh switch de
Switch/Stack Mac Address : 68bd.abc9.0000
H/W   Current
[Code]....

View 36 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S For IPTV Backbone

Nov 26, 2011

we have Catalysts 2960S for switching in our Wireless high capacity backbone network. As agregation switch we are using 3560x.
 
I just need to know, if are these 2960S good solution for igmp snooping for whole IPTV stream. It put only a range from backbone and put out on another port. But just specified multicast addresses.
 
Imput will be 239.128.0.10 to 239.128.0.20 on Gi 0/1,Output wil be 239.128.0.10 - 15 on Gi 0/24
 
IPTV will be separated on different VLAN for eg VLAN 20,Is needed any priorization configured od switches?,The capacity for IPTV is around 500 mbps

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S Format Flash Failure?

Jan 3, 2013

I recently tried to manually format the flash on a model WS-2960S-48TS-L switch running IOS version 15.0(2)SE.  While executing the operation I got the following error - mifs[8]: Failed to create superblock  %Error formatting flash (I/O error).As a result the flash is no longer accessible by the switch.  I spoke with Cisco and they indicated that a switch reload would remount the flash and make it accessable again but the .bin file would need to be reloaded using the xModem recovery procedure (what a pain).The next IOS version 15.0(2)SE1 will supposedly fix this bug but it has not been released yet.  In the meantime if you are running 15.0(2)SE you may want to hold off performing a "format flash:" function on a 2960S.

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S - Protected Port But Allow Specific MAC?

Nov 5, 2011

We are using catalyst 2960S Lan Base IOS on Radio towers. We just bought 50 Accest points, thas are GPS synchronized. Problem is the APs need to be connected on L2-mac betwen each other. But at this time we are using port isolation on each switch (tower) by protected port function to isolate clients from each other.
 
My question is, is possible to specifi a Mac addresses in specific vlan thats can comunicate betwen protected ports? On tower is one Master unit and others are slave. I thing there is only 1 dirrection comunication - from master to slave.

View 2 Replies View Related

Cisco WAN :: Receive Full BGP In 6506 Switch?

Mar 13, 2013

I want to receive full BGP in my switch 6506 with the follow characteristics: cisco WS-C6506-E (R7000) processor (revision 1.2) with 458720K/65536K bytes of memory and Supervisor Engine 720.When I configure the session BGP in my router with me peer the switch begins to work slow and restarts.

View 2 Replies View Related

Cisco WAN :: Bootloader Backup Of 6506 Switch

Aug 17, 2011

I am little confused of how to take bootloader backup of cisco 6506 switch with WS-C6506-1300A CHASSIS and WS-X6K-SUP2-GE sup I am  pesting a the part of sh run to show you the image files for the switch.

!
boot buffersize 522200boot system sup-bootflash:c6sup22-jsv-mz.121-8b.EX5boot bootldr bootflash:c6msfc2-boot-mz.121-8b.EX5enable password !
redundancymain-cpu  auto-sync standarddiagnostic level complete
 
take backup two files in a tftp server.

View 1 Replies View Related

Cisco Switching/Routing :: 2960S - Internal Power Supply Show Unavailing When Running Off RPS?

Feb 13, 2012

I have a 2960S connected to an RSP 2300.  The 2960S is currently running off of the RPS, and I would like to switch it back to the internal power supply.  Can I just run "power supply 1 on"?  Will this cause the switch to reboot?  Also I am concerned because when I do a show env power it shows: [code]
 
 Is it normal for the internal power supply to show Unavail when running off RPS?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S / Downgrade 10GB Twinax CU SFP Cable To 1GB?

Oct 30, 2012

specifying Cisco devices and I've made an error.I have 2 Catalyst 2960S switches (C2960S-24PS-L).Based on this snippet of web copy from the Cisco website:What's new for the Cisco Catalyst 2960-S Series Switches with LAN Base Software: # 10 and 1 Gigabit Ethernet uplink flexibility with Small Form-Factor Pluggable Plus (SFP+), providing business continuity and fast transition to 10 Gigabit Ethernet I bought a cable assembly "SFP-H10GB-CU3M" (3 meter copper twinax cable with 10GB SFPs on each end).  Unfortunately, it appears after more careful reasearch that my specific model 2960S's are not directly compatible.  , can I force these 10GB SFPs down to 1GB and get them to work with my switches or do I need to return and repurchase?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S Port-Based Address Allocation?

Sep 27, 2012

I just bought a Catalyst 2960S to test out the feature "Port-Based Address Allocation" which is required for our factory. I followed the instruction from Cisco IOS and did all the steps but I could not get it to work, my network client did not received the expected IP address that I configured.

View 8 Replies View Related