As part of a DC deploy, aI have to install 2 x ASA5580. My surprise was the missing connection bolts (or place) on the chassis for the grounding cable. All othes equipments (ASR, 6500, Nexus 7K) have a grounding connection on their chassis.
The Installation manual alerts and requests a good gorundid for it. But where should I put it??Note that the rack where it's installed on is already grounded.
I need to estimate the installation and configuration time of Cisco NAC (NAC Network Module spare for 2800, 3800 ISR) and Cisco NAC Manager(NAC Appliance 3315 Manager -max 3 Servers. There is some Cisco tool to estimate the installation and configuration time?
I was trying to search for cisco vpn client version 5.x for MAC OS but only saw the latest version at 4.9. If version 5 is out for MAC? Also, what the latest possible version of the vpn client is for MAC that is compatible with both the vpn 3080 concentrator and asa5580?
I'm trying to test Anyconnect VPN but after configuring the required configuraiton I'm not getting Anyconnect client downloading and it just log into the clientless webvpn. Below are my basic required configuration. I have tried with few other ASA the same configuration but it worked fine. I'm using the default SSL VPN base license (02) with the ASA5580 code running 8.2.2
I have a laptop having wifi & a desktop .I have purchased a "D-link WIRELESS N 150 USB ADAPTER" for desktop.some time ago my both pc are connected by LAN cable..but now i want to connect them via wireless..
I'm facing the following doubt regarding the AC Power Connector on the 1522 AP.We are powering up the AP through PoE, so the AC Power Connector is not used.BUT,do i have to seal/protect the connector or leave it as is?
I have a router 3600 with a power connector kind RPS but I don't have a RPS system, Do it exist a kind of wire that I can connect directly from my router to AC?
Anyway, here's the situation I'm trying to configure several VLANs on my ASA to uniquely allocate to contexts, the VLANs will be trunked from my VSS. Unfortunately I'm not clear on how to achieve this, the configuration guide for 8.4 talks about multiple contexts and routed setups all which don't appear to apply exactly. I've configured the port channel at both ends and I've configured sub-interfaces on the port channel and assigned VLAN IDs. These sub-interfaces are then allocated to the contexts to set 'ip address' etc. I've not been able to successfully test this configuration and I am concerned that it is incorrect..
I am having issues with PXE boot images for PCs cannot be loaded from remotely.The diagnosis revealed that SunRPC & TFTP were being inspected by ASA causing drop of packets.So I excluded these two inspections for the particular server behind the firewall. It seem to resolve the issue for instance but it crawled back again.
Is there a way that the inspection can be turned off for that particular server at the IP level?
I just need to add new connectors and I'm good to go. The PCs have cabinets with Ethernet sockets in them and these will also need re-wiring with a RJ45 jack then a faceplate mounting as they are totally bare at the minute.Also, I think I need to learn this as a whole, it will become a regular thing, do I need the following tools to do the basics of cabling ?RJ45 Network Crimp Tool 10 Boots & Ends Crimping Kit Play.com - Buy RJ45 Network Crimp Tool 10 Boots & Ends Crimping Kit online at Play.com and read reviews. Free delivery to UK and Europe!|cat:3516420|prd:3516420[CODE]
I have a long 2 pair cat 5 cable which I want to use to connect a ADSL modem to my desktop (located in a different room). I took the cable to few local computer dealers but none of them could connect an RJ-45 connector to it. They can only connect a 4 pair cat 5 cable. Connect a 2 pair cat 5 Ethernet cable to a RJ-45 connector. Kindly use simple language. I have attached an image of the cable for your reference. [URL]
Trying to replace 3Com Superstack II Switches (3C16980) with 100Base-FX Modules (3C16970) with a Cisco solution. Existing Fiber connector in Network closet on both ends is an SC connector (picture attached). What Modules, adapter cables do I need to connect to an SRW2048 switch at one end an SRW2024 switch at the other? Will this solution provide a Gigabit connection over the Fiber ?
I am looking at using SRW2048-K9-NA with MGBSX1 module at one closet and SRW2024-K9-NA with MGBSX1 module in the other closet at the other end of the Fiber cable.
I found an adapter cable that will convert an SC male to an LC Male and it looks like it will work but I have no experience with fiber. I attached a picture of this adapter as well. It is listed on line as - 1ft Fiber Optic Adapter Cable LC (Male) to SC (Female) Multimode 62.5/125 Duplex
We have an active-active pair of cisco ASA5580-20 with software version 8.4(1)9. There are 8 contexts on it (including admin and system). 1 context is active on Primary node and other 7 are active on Secondary node. User traffic is going through this 1 context (2 interfaces - inside to users, outside to internet) and there are peaks to 1.16M concurrent connections, max bandwidth is 1.25Gbps. CPU usage for this context in peak hours is 63%, but we noticed that when we run "show cpu usage context all" from system it shows that system context is using 25% of CPU and "Total CPU utilization" (form output of show cpu detailed - on system context) is 88% which is bad. In non peak hours - user context use 33.6% CPU, system use 14.5%, total CPU usage is 50.5% So, is it normal this cpu utilization on system context (system on Primary node)?
Running ASDM V6.3 connecting to a couple of ASA5580's V8.2. After initial configuration everything seemed to work great, however, as of a few days ago I can no longer view statistical information. I can attach to the devices without a problem, view and edit all configuration information but the dashboard applets do not pull or display any statistical info. Resource, Interface, and Traffic status all time out with the error "Lost Connetion to Firewall". The syslog info is not display rather the error "Syslog Lost Connection". My first thought was a java issue on the client. I have ripped out and reinstalled even back-revisioned to no avail. I'm to the point where a dumpe of the management workstation is the next step. I'd like to avoid that extreme if possible.
i have a cisco switch CISCO Catalyst 2960S 48 GigE, 4 x SFP LAN Base WS-C2960S-48TS-L for this i need a 1GB GBIC Connector. need right GBIC connector module and ather details
customer has a server which located in inside interace. and an outside interface connected to ISPA. cu config a static nat map inside server address to ISPA address, one day customer install a new outside interface to ISPB, cu config new static nat ,map same server inside server address to ISPB address. the server will allways be vistited from outside interface and reply, custome want traffic coming from ISPA will return to ISPA, traffic coming from ISPB will return to ISPB. but i found it is difficult implement this on ASA5580. i want use route-map on static nat, but it will not satisfy customer's request.
i have a problem customer has a server which located in inside interace. and an outside interface connected to ISPA. cu config a static nat map inside server address to ISPA address one day customer install a new outside interface to ISPB, cu config new static nat ,map same server inside server address to ISPB address. the server will allways be vistited from outside interface and reply, custome want traffic coming from ISPA will return to ISPA, traffic coming from ISPB will return to ISPB. but i found it is difficult implement this on ASA5580. i want use route-map on static nat, but it will not satisfy customer's request.
I am looking for the way to define an idle timeout for specific flows on an ASA5580 by using Cisco security manager. For ex I needed to define a specific idle timeout for connections beetween specific devices (Devices in vlan1, Device2 in vlan2).To test it I did following changes by CLI and it works fine. access-list L1 extended permit ip <@IP1> <mask1> host <@IP2> class-map CM1 match access-list L1 policy-map PM1 class CM1 set connection timeout idle 02:00:00
I try do do the same configuration with CSM in order to be able to manage each changes only by using CSM.So I defined Access control list, Traffic flow and then I define timeout in CSM --> PIX/ASA/FWSM Platform --> Service Policy Rules --> IPS, QoS and Connections Rules -> connections settings -> Traffic flow idle time-out. The problem is that each time I deploy the configuration with CSM I loose the timeout config line which is the most important for my application..
I have a 'DSL-2640U WIRELESS G ADSL2+ 4-PORT ROUTER'.I was using a DSL connection earlier, now I have moved to a ADSL connection.And I have been told by the service provider to get a different router with an ADSL input port.Can I use the same router for the ADSL connection using any converter or connector.
I come across to use the Catalyst Switch 2955 and it has two Relay Connector with one Major (MAJ) and one Minor (MIN) as below picture.There is command line to trigger these two Relay Connectors. As below command to set the Relay Connector to minor for monitoring the power supply: alarm facility power-supply relay minor
1. My questions are when there is power-supply faulty, the Minor Relay Connctor (right picture) will be short-circuited, right?
2. If we connector the two ports (ports 4 & 5 at the left picture) with a normal cable to drive an Alram Bell (in short-circuiled or closed loop situation), do we need an external power supply to the Alram Bell? Or there will be power supply from Catalyst 2955 to the Alram Bell as well?
On the WAN port, there are 4 pins that are traced to the internal serial traces. Where can we get the cable that will fit into the WAN RJ-45 port and have a serial connector on the back end. It may be called a Cisco Debug Adapter, but we haven't been able to find?
I cannot utilize my Ethernet connection when my Dell Latitude D630 is connected to a docking station. I have tried this on two different docking stations. I also have another Dell laptop that I have used in the one of the same docking stations and the ethernet connection is fine. I'm looking for assistance to troubleshoot this (even just determining if I can replace the connector and how I determine what type I need)
I'm trying to install LMS 4.0 on a 2008 R2, I got a message saying that this is not supported. Going through Cisco documentation I read the following:
Caution If you want to upgrade the operating system from Windows 2003 or Windows 2008 to Windows 2008 R2, you must first complete upgrading the operating system, and then install the LMS 4.0.x Windows 2008 R2 patch.
I'm a bit confused because i'm not upgrading the operating system, this is a fresh install.
I tried to run this in compatibility mode, selected 2008, and running it as an Admin, this time I'm getting a Locale error stating that this is only supported in US English or Japanese. I've changed the system locale to US English, still getting the same error.
I have router cisco 2821 wit IOS version 12.4(25d) I also have Cisco AIM-VPN/SSL-2 Encryption Module for this router.I inserted this module in AIM slot 0 but can not see it. [code] What should I have to change to enable this module?
I just got two Prime NCS Servers for my system and they came with 1.2. My management wanted to run the lastest IOS which is 1.3. So as soon as I set the physical equipment up, I downloaded the latest 1.3 IOS for the site and burned it on a DL DVD and reimaged the appliance.
We've just purchased the a VM Version of MSE (L-MSE-C3-W25) installed on vSphere.Have followed the guide, gone to add this to WSE and it wont connect.Looking at the console it says to type /init.d/msed.start, I get -bash: /init.d/msed: No such file or directory Then type getserverinfo returns Health Monitor is not running.
Any info concerning the installation of CW LMS 4.0.1 on Solaris 10!
The installation keeps on failing when it is checking for packages. Also the second time when we downloaded the software once more.
ERROR: AddProperty called with invalid package name: CSCOmd.
I have also attached the install log files.
The system is Solaris 10 with zones:
bash-3.00# more /etc/release Solaris 10 10/09 s10s_u8wos_08a SPARC Copyright 2009 Sun Microsystems, Inc. All Rights Reserved. Use is subject to license terms. Assembled 16 September 2009 121133-02, 125503-02, 126897-02, 127127-11, 127755-01, 138866-01 Incompatibles: [Code] .....