Cisco Switching/Routing :: 2960 - 1GB GBIC Connector Module
Nov 6, 2012
i have a cisco switch CISCO Catalyst 2960S 48 GigE, 4 x SFP LAN Base WS-C2960S-48TS-L for this i need a 1GB GBIC Connector. need right GBIC connector module and ather details
View 1 Replies
ADVERTISEMENT
Apr 24, 2012
I have a Cisco WS-C6513 switch, with a couple of GBIC module cards in it. I am trying to display the part number (or model number) of the modules which are inserted into this module card. How to do that? I don't want to schedule down-time to pull the module(s) - just to read the label! :-)
This shows me info for the "module card": sh module 9 But this doesn't work: sh module 9/6
View 4 Replies
View Related
Jun 25, 2012
I am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps. When connected together they do not enable. Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?
View 2 Replies
View Related
Mar 6, 2012
We have supplied Cisco Swtch 2960 with gig SFP modules. It is working fine. However, when I do a show inventory it show proper part no. for the switch chassis but for the GLC T module it shows as unspecified in the PID column.
View 1 Replies
View Related
Sep 2, 2012
My Cisco 2960 Switch hanging problem (does not work or LED light), when i removed SFP module slots its working fine.
View 1 Replies
View Related
Feb 6, 2012
I come across to use the Catalyst Switch 2955 and it has two Relay Connector with one Major (MAJ) and one Minor (MIN) as below picture.There is command line to trigger these two Relay Connectors. As below command to set the Relay Connector to minor for monitoring the power supply: alarm facility power-supply relay minor
1. My questions are when there is power-supply faulty, the Minor Relay Connctor (right picture) will be short-circuited, right?
2. If we connector the two ports (ports 4 & 5 at the left picture) with a normal cable to drive an Alram Bell (in short-circuiled or closed loop situation), do we need an external power supply to the Alram Bell? Or there will be power supply from Catalyst 2955 to the Alram Bell as well?
View 1 Replies
View Related
Nov 7, 2011
I have an interesting problem. I have a 6509 that I'm trying to swap the GBIC on. The switch is already using a GLC-SX-MM GBIC and it is up/up and passing traffic, but we are getting some errors and suspect it may be faulty.
I want to replace the GBIC with one of the identical model - a GLC-SX-MM. It was brand new, never been opened. When the new GBIC is plugged in the link light on the switch goes completely off (not amber) and the port goes into a down/down (not connect) state. There are no messages in the logs at all. It's like it doesn't even see it. If you plug the old GBIC back in then the link comes back up. I tried a different port with the same results.Thinking that the new GBIC may be faulty (even though it was brand new) I tried a second GLX-SX-MM, also new. That one does the same thing.
At that point I thought there might be a problem with that switch, so I tried the GBICs on the other 6509 in that pair. The other 6509 is running the same hardware and software. The GBICs will not work there either. If you move the old, suspected faulty GBIC from 6509-2 to 6509-1 then that it works.
The solution would seem to be that I have two faulty GBICs, but I'm having trouble persuading myself that I have two new ones, straight out of the package, that are both bad. Are there any other things to check on the switch? Here's the pertinent information:
switch#show ver
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXI3, RELEASE SOFTWARE (fc2)
<snip>
cisco WS-C6509-E (R7000) processor (revision 1.3) with 458720K/65536K bytes of memory.
Processor board ID SMG1109N3BK
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
[code]...
View 15 Replies
View Related
Oct 22, 2012
I've inherited a network. It looks to have been setup as 10/100 originally, using Netgear FSM726S switches with fibre connecting the switches. The fibre to copper conversion is mainly achieved with 10/100 media convertors rather than GBICs - not sure why - though there are some GBICs in use. Some of the "key" switches have been upgraded to Cisco Catalyst 2960G switches, but nothing else has been touched, so most of the network still runs at 100MB.
View 1 Replies
View Related
Mar 11, 2013
is there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies
View Related
Dec 7, 2011
I am trying to get a C2960-8tc-L linked to a sge2000p via the Gbic ports using GLC-SX_MM gbics but having no luck.Are these compatible and should I need to configure anything?
View 1 Replies
View Related
Jun 17, 2012
I am having problems configuring a 4900. I have entered the following commands:
hw-module module 2 port-group 1 select gigabitethernet
hw-module module 2 port-group 2 select gigabitethernet
hw-module module 2 port-group 3 select gigabitethernet
hw-module module 2 port-group 4 select gigabitethernet
However no matter what I try, it never sees the GLC-SX gbics I have in the TwinGig converter.
PERSW001#sh interfaces status mod 2
Port Name Status Vlan Duplex Speed Type
Te2/1 inactive 1 full 10G No X2
Te2/2 inactive 1 full 10G No X2
Te2/3 inactive 1 full 10G No X2
[code]....
View 8 Replies
View Related
Nov 9, 2011
Is there any command to display the GBIC in the switch because I need to replace 3550 but I have no exact part number
the model is WS-C3550-24-SMI
and try
sh inventory
sh hardware
sh diag
sh module
View 1 Replies
View Related
Dec 14, 2011
Everything is in the title...When I plug a GBIC adapter on a port, my switch reload automatically..! Is it normal, because I did it during production and It disconnects some users.
View 0 Replies
View Related
Jul 18, 2012
The module WS-X4306, support fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?
View 1 Replies
View Related
Feb 7, 2012
I have an existing stack of 4 x 2960-S switches connected by stack cables.I would like to add another 2960-S switch to the stack but am unable to as the 2960-S will only allow 4 x 2960-S switches per stack.how I would add the 5th 2960-S switch to the existing stack of 4 x 2960-S switches.
View 12 Replies
View Related
Feb 11, 2013
I have a 24 port 2960-S that is not communicating with a 2960-LST that it is directly connected to over fiber. The link is up on the LST but will not come up on the -S. What command should I use to bring up this link? I have tried no shut from the (Config-if)# prompt.
View 3 Replies
View Related
Feb 8, 2013
tell if a 2960S switch has a stacking module in it, aside from physically looking at it?
View 2 Replies
View Related
Jun 10, 2013
i have a cisco router (3900 series) and a add on module (4 x 1 Gig port module). For some reason i cant seem to port channel them and cant do routing (can set an ip address on those ports). I can do port channel and routing on on-board ports. Do i have to enable any commands to do this ?
View 3 Replies
View Related
Jan 17, 2013
My management has tasked me to give them a high level overview of the different switching we can choose for our new building.
This is what I know so far.4 Closets, each closet has 450 ports,One MDF room that is will contain one UCS Chassis and a Nimble iSCSI SAN.
I am working on the spreadsheet and it looks like this (Not totally filled):
2960s3560x3750x45064510Approx cost (Each, 48PORT, POE+, 10G uplink, Dual PS, IP BASE)
6K7K8K45K75KMax Capacity192432432192384Backplane speed206464520520ProLeast ExpensiveStackable to 9Stackable to 9ProDual PSDual PSDual PSDual PSDual PSProLayer 3 opt
Layer 3 optDual SupsDual SupsConExpensiveExpensiveConNo Dual PSConLayer 2 OnlyCannot stack more than 4
For the MDF I would like to use 2 Nexus 5548's with FEX's, and the layer 3 daughter board. For the IDF's I was thinking of two 4010's.
View 12 Replies
View Related
Jun 24, 2012
Was wondering if anyone has ever hot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?I looked at the H/W install guide and it does not mention anything.
View 3 Replies
View Related
Dec 3, 2011
My C6506 USING ws-sup720-3B, i upgrade the IOS to the latest release of 12.2(33) SXJ1 IOS version. After upgrade and reload the machine got one module cannot be detect..WS-X6416-GE-MT, 16 port 1000mb MTRK ethernet module. The version of this are:
-HW 1.0
-FW 5.3 (1)1
-SW 8.5 (0.46) RFW
Question 1: Any tools available on cisco to check out the hardware/software compabiity feature?
Question 2: Any release note, compability matrix table etc resources.
View 1 Replies
View Related
Sep 4, 2012
Recently we ha a Nexus 7010 with a module frozen that was OIR (Online Remote and Insert) but do not work until reload the Nexus 7k.The command "show tech-support" has the following:
exception information --- exception instance 64 ----
Module Slot Number: 1
Device id : 147
Device Name: 0x93
Device Errorcode: 0x9329201
[code].....
Was is Excessive Interrupt Events? Can this "Minor Error" frozen the system?Is the port 42 on module 1 affected? o was 42 ports?
View 2 Replies
View Related
Jun 25, 2012
Can the encryption module (DES/ 3DES/AES/SSL VPN Encrytion/compression) for Cisco Router 3845 able to support the external connection from other high end router, for example cisco 7200? What is the maximum bandwidth, load and concurrent connection it can support?
View 1 Replies
View Related
Feb 3, 2013
why is not possible to put a WS-X4712-SFP+E - module into an R-E chassis?The module has the same connection to backplane as the WS-X4748-UPOE+E and this one works in a R-E chassis.I know the restriction of Cisco that the 4712 is only supported in 4503-E, 4506-E,4507+E and 4510+E, but why?Are there hardware-restrictions, is the backplane different?
View 2 Replies
View Related
Sep 10, 2012
I have a pair of 6509-E Switches running VS-720 Supervisors. We are planning to add Ace Module onto the 6509-E. Will IP Base Image suffice the requirement? Will Ace Module work with only IP Base Image?
View 1 Replies
View Related
Dec 16, 2012
Hot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?
View 2 Replies
View Related
Jan 6, 2013
Do you have any document that states whether WS-X4606-X2-E module is hot swappable or not?
View 2 Replies
View Related
Feb 20, 2012
confirm the C3KX-NM-10G module is hot-swappable.i have checked the cisco's website and it says " Although network modules are hot-swappable, we recommend installing a network module before powering the switch"
What steps i need to follow to install the module?
View 5 Replies
View Related
Apr 12, 2012
Using the new SUP-2T, need to clarify one query. If we are using the new SUP-2T in VSS mode, will the new ASA service module and NAM-3 are supported? From Cisco site, ASA module FAQ:
Q. Will the ASA Services Module support the Cisco Catalyst Virtual Switching System (VSS) at FCS?
A. Yes, depending on which supervisor you use. The ASA Services Module supports VSS either as a single firewall or as a failover pair of firewalls, when used with the Supervisor 720-10G (VS-S720-10G-3C and VS-S720-10G-3CXL). Transparent and multi- context modes also work with the VSS in this configuration. However, though the SUP 720-3B (WS-SUP720-3B and WS-SUP720-3BXL) is supported by the ASA Services Module, it is not capable of supporting the VSS. No reference to Supervisor-2T.
View 2 Replies
View Related
May 4, 2013
switch 6506 E with supp 720 does it support 10 GIG module ?
View 3 Replies
View Related
Jan 4, 2012
I have a client whom has a 4900M switch as their SAN switch. They are getting ready to upgrade their SAN to use 10G.I had quoted them a price for an X2 module, but I am unclear based on pictures I have seen of the part number
X2-10GB-SR
whether or not the X2 module plugs into the X2 slot on the switch, AND then also has to have a transceiver put in it to receive the SC ends of the Fiber jumper, or whether the SC ends of the fiber jumper plug into the X2 module directly.
View 5 Replies
View Related
Mar 4, 2012
I have a switch Cisco WS-C6509-E WS-X6716-10G-3C module ( module for 10 GB) , i have the IOS s72033-ipservicesk9-mz.122-18.SXF9.bin. I want to know if this IOS can support this module or not ? or , if i must do a upgrade , is that the IOS : "s72033-ipservicesk9_wan-mz.122-33.SXH8" work fine ?
View 7 Replies
View Related
Aug 24, 2012
i have a cisco Netowtk Analysis module installed on a 6513 core switch which is NAM-1, the version on the NAM is 5.1 and we need to upgrade to the latest version which is 5.1(2)
View 1 Replies
View Related