Cisco Switching/Routing :: Get C2960-8tc-L Linked To Sge2000p Via The Gbic Ports?
Dec 7, 2011
I am trying to get a C2960-8tc-L linked to a sge2000p via the Gbic ports using GLC-SX_MM gbics but having no luck.Are these compatible and should I need to configure anything?
View 1 Replies
ADVERTISEMENT
Apr 8, 2012
I want to know what is the different between IOS of the catalyst WS-C2960-48PST-S and the IOS of catalyset WS-C2960-48PST-L.a want to upgrad the IOS of a WS-C2960-48PST-S with the IOS of WS-C2960-48PST-L (because this reference has a LANBASE version of IOS).
View 4 Replies
View Related
Apr 24, 2012
Is it possible to configure LACP etherchannel to a Catalyst 3750? Playing around with the SMB switches for the first time.
I know how to do it on the 3750 but am having trouble figuring out the sge2000p.
View 2 Replies
View Related
Nov 7, 2011
I have an interesting problem. I have a 6509 that I'm trying to swap the GBIC on. The switch is already using a GLC-SX-MM GBIC and it is up/up and passing traffic, but we are getting some errors and suspect it may be faulty.
I want to replace the GBIC with one of the identical model - a GLC-SX-MM. It was brand new, never been opened. When the new GBIC is plugged in the link light on the switch goes completely off (not amber) and the port goes into a down/down (not connect) state. There are no messages in the logs at all. It's like it doesn't even see it. If you plug the old GBIC back in then the link comes back up. I tried a different port with the same results.Thinking that the new GBIC may be faulty (even though it was brand new) I tried a second GLX-SX-MM, also new. That one does the same thing.
At that point I thought there might be a problem with that switch, so I tried the GBICs on the other 6509 in that pair. The other 6509 is running the same hardware and software. The GBICs will not work there either. If you move the old, suspected faulty GBIC from 6509-2 to 6509-1 then that it works.
The solution would seem to be that I have two faulty GBICs, but I'm having trouble persuading myself that I have two new ones, straight out of the package, that are both bad. Are there any other things to check on the switch? Here's the pertinent information:
switch#show ver
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXI3, RELEASE SOFTWARE (fc2)
<snip>
cisco WS-C6509-E (R7000) processor (revision 1.3) with 458720K/65536K bytes of memory.
Processor board ID SMG1109N3BK
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
[code]...
View 15 Replies
View Related
Mar 27, 2013
I faced with a strange behavior of ME3600.For testing purposes I linked Cat3550 and ME3600 switches via trunk mode. All interfaces are in Up state. But I couldn't ping SVI200 of Cat switch from ME3600 and vice versa. [cde]
This scheme perfectly works with another L3 swithes. For example Catalist3750. I know that ME doesn't support VTP, DTP and so on. Also, I've tried latest software.
View 0 Replies
View Related
Oct 22, 2012
I've inherited a network. It looks to have been setup as 10/100 originally, using Netgear FSM726S switches with fibre connecting the switches. The fibre to copper conversion is mainly achieved with 10/100 media convertors rather than GBICs - not sure why - though there are some GBICs in use. Some of the "key" switches have been upgraded to Cisco Catalyst 2960G switches, but nothing else has been touched, so most of the network still runs at 100MB.
View 1 Replies
View Related
Mar 11, 2013
is there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies
View Related
Nov 6, 2012
i have a cisco switch CISCO Catalyst 2960S 48 GigE, 4 x SFP LAN Base WS-C2960S-48TS-L for this i need a 1GB GBIC Connector. need right GBIC connector module and ather details
View 1 Replies
View Related
Aug 27, 2012
I have a sge2000p to install with a uc520. I have all data traffic passing ok but voice will not work. Phones to not get ip etc.
View 4 Replies
View Related
Apr 24, 2012
I have a Cisco WS-C6513 switch, with a couple of GBIC module cards in it. I am trying to display the part number (or model number) of the modules which are inserted into this module card. How to do that? I don't want to schedule down-time to pull the module(s) - just to read the label! :-)
This shows me info for the "module card": sh module 9 But this doesn't work: sh module 9/6
View 4 Replies
View Related
Jun 17, 2012
I am having problems configuring a 4900. I have entered the following commands:
hw-module module 2 port-group 1 select gigabitethernet
hw-module module 2 port-group 2 select gigabitethernet
hw-module module 2 port-group 3 select gigabitethernet
hw-module module 2 port-group 4 select gigabitethernet
However no matter what I try, it never sees the GLC-SX gbics I have in the TwinGig converter.
PERSW001#sh interfaces status mod 2
Port Name Status Vlan Duplex Speed Type
Te2/1 inactive 1 full 10G No X2
Te2/2 inactive 1 full 10G No X2
Te2/3 inactive 1 full 10G No X2
[code]....
View 8 Replies
View Related
Nov 9, 2011
Is there any command to display the GBIC in the switch because I need to replace 3550 but I have no exact part number
the model is WS-C3550-24-SMI
and try
sh inventory
sh hardware
sh diag
sh module
View 1 Replies
View Related
Dec 14, 2011
Everything is in the title...When I plug a GBIC adapter on a port, my switch reload automatically..! Is it normal, because I did it during production and It disconnects some users.
View 0 Replies
View Related
Jul 18, 2012
The module WS-X4306, support fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?
View 1 Replies
View Related
Jun 25, 2012
I am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps. When connected together they do not enable. Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?
View 2 Replies
View Related
Dec 26, 2012
We have a customer who uses about 20 x c2960's switches for access layer and 2 x c3560e for distribution layer. C2960's uses C2960-LANLITEK9-M , Version 12.2(58)SE1. Everything was working fine. Now we got information, that sometimes there are problems with connectivity. Customer tries to reach internet.
SW11#sh int fa0/18
FastEthernet0/18 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is e8ba.806a.4412 (bia e8ba.806a.4412)
[Code].....
View 7 Replies
View Related
Jan 29, 2012
I am having problem in upgrading Cat2960 because I deleted the flash in this switch already and now I need installing an IOS image? [code]
View 1 Replies
View Related
Mar 12, 2013
I am trying to configure RSPAN for one of my client. They have Server-Client VTP architecture. Voice Recording Server is connected to C4507. Agents are connected to C2960 and C3750. I got 2 sessions configured and the connectivity is a as follows:
1. Voice Recording Server-----C4507-----C2960-----C2960-----Agent IP Phones (Session 1)
2. Voice Recording Server-----C4507-----C3750-----Agent IP Phones (Session 2)
Recording works with Session-2 but not with Session-1. I understand the problem could be due to multiple reasons: 1.1. C2960 is working in client VTP mode so i cannot add remote span command under the vlan configuration. 1.2. C2960 has LANLITE IOS image which i am not sure if it supports Remote Span.
View 2 Replies
View Related
Apr 23, 2013
I have a C2960-24TT-L Switch with the following problem:When the Power Cord is plugged in the Switch, all switch indicator LEDs go on very briefly. Then SYST LED blinks very briefly, goes on steady and remains at this state without any indication at the console.Tried the reset by holding the MODE button while plugging in power but I still get no indication at the console. All is fine with console, meaning that if I take out the cable and plug it in another switch, then I see all that there is there to be seen.My question: Is the switch beyond repair or is there something that can be done to get the switch to run POST and boot at rommon so that I can reload SW and configs?
View 3 Replies
View Related
Apr 26, 2012
I have two WS-C2960-24TC-L Switch with Software Ver 12.2(25r)SEE6 with image c2960-lanbase-mz.122-35.SE5.bin and 12.2(25r)SEE1 with image c2960-lanbase-mz.122-25.SEE2.bin currently on it.
I want to enable SSH connections on the switches and believe I need to import the cryto image onto the switch. I would like to upgrade it to new version that can also support ssh connection but not sure which image to download from cisco. The switches are now live.
System image file is "flash:c2960-lanbase-mz.122-35.SE5/c2960-lanbase-mz.122-35.SE5.bin"
cisco WS-C2960-24TC-L (PowerPC405) processor (revision H0) with 61440K/4088K
[Code].....
View 5 Replies
View Related
Feb 7, 2012
I've got a C2960 (sw01) and a C2948. (sw02) The sw02 switch is trunked with sw01, and is meant to serve as an extension to the VLANs (1-4) that exist on sw01. It is trunking properly, however, how would I go about giving the sw02 an IP so that I can access it via SSH? Would I have to create a VLAN specifically on sw02 with an ip and switchport an interface to use it? I know that a VLAN can only have a single IP, but I'd like sw02 to have an IP on VLAN1 (192.168.1.0 subnet), is that possible?
View 5 Replies
View Related
Feb 14, 2012
i am trying to upgrade the firmware in my C2960 switch to 15(1) SE2, and i get the error:Failed to execute the command archive download -sw /overwrite /http iosFile
View 2 Replies
View Related
Jul 1, 2012
I am not sure why the CRC and input errors are increasing in fastethernet port...This port is used as Intradomain cross connect to Data Center service provider for LAN extension between two Data Centers in different locations... The link is 100 MB. The switch port is directly connected to patch panel of DC provider and I believe they have some L3 switch or some other device that is providing LAN extension...
#sh interfaces fastEthernet 0/23
FastEthernet0/23 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0019.3050.1497 (bia 0019.3050.1497)
Description: ASA_VPN_TO
MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
[code]....
View 26 Replies
View Related
Oct 2, 2012
I am not sure why the CRC and input errors are increasing in fastethernet port...This port is used as Intradomain cross connect to Data Center service provider for LAN extension between two Data Centers in different locations... The link is 100 MB. The switch port is directly connected to patch panel of DC provider and I believe they have some L3 switch or some other device that is providing LAN extension...
#sh interfaces fastEthernet 0/23
FastEthernet0/23 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0019.3050.1497 (bia 0019.3050.1497)
[Code].....
View 3 Replies
View Related
May 19, 2013
I have an issue with one of our switches, switch model WS-C2960-24TC-L, i am not able to display switch temperature as below,
Switch#sh verCisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 15.0(2)SE2, RELEASE SOFTWARE (fc1)Technical Support: URL ) 1986-2013 by Cisco Systems, Inc.Compiled Tue 05-Feb-13 12:41 by prod_rel_team(code)
View 2 Replies
View Related
Jan 8, 2012
We just purchased (3) WS-C2960-24CT-S and (1) 3750G, what's the proper way to cascade this switches? Do I need to use crossover cables from port to port? Do I need to change the mode for the ports to use?
View 6 Replies
View Related
Nov 9, 2012
I am facing high memory utilization in Cisco 2960 switch having IOS version 12.2(55)SE3.
The error we are getting is:
A "LiveHealthAlarm" event has occurred, from SwCiscoIOS device, named Switch2960. eHealth Alarm Start Time - Fri 09 Nov,2012 - 03:02:48 eHealth. Switch2960-RH-MemoryPool-Processor-Processor-1.Memory utilization high-Threshold set at 70%SPECTRUM ALARM ID|22233284 I have attached the logs also.
View 3 Replies
View Related
Aug 14, 2012
Yesterday I tried to install c2960-lanbasek9.mz.12.55.SE4.bin onto my router. When I changed the boot commands, I did not leave the 2nd option in there and the old firmware has an .ex3 extension. After trying to boot to this new image, we receive a looping error message that continues to reboot and go through the same process.Basically the error is "ERROR: firmware not supported by hardware"I have power cycled it a few times but durning bootup, I never see the ################## which would allow me to BREAK sequence and get into rommon. The device simply waits about 30-40 seconds after boot and goes right back to the looping reboot sequence and the error message. Is there any hyper term or putty settings to change on this?
View 1 Replies
View Related
Sep 15, 2008
I'm trying to configure the GigabitEthernet interface of the WS-C2960 switch to have a full duplex. Unfortunately, there is no option to configure this neither is the speed of that interface. But these options are present in FastEthernet ports. Is there a bug in SW version 12.2(35)SE5 that explains this abnormality?
View 6 Replies
View Related
Apr 15, 2013
I have an inquiry about a configuration I deploy in a C2960 switch. I have configured a ether channel with 8 ports, the load balanced method is source mac address. The bundling protocol is LACP.
I have found the ether channel is not balanced as I expect. One of the eight interfaces is congested.
Code...
View 2 Replies
View Related
Dec 8, 2011
I want to know is there is an license for upgrading the C2960-48PST-S to the "L" version (Lan Base).
View 2 Replies
View Related
Apr 4, 2013
Customer has a Catalyst WS-C2960-48PST-L. and in some ports we have VoIP phones with PoE company Aastra. If I use first config we have problem when phone boot up.
First config:
description tp-11-voip
switchport access vlan 250
switchport mode access
switchport voice vlan 201
switchport port-security maximum 2
switchport port-security(code )
The MAC shown here is from a voip Phone. After the phone boot up, the p, because it must boot first in vlan 250 (access vlan). On the port you can only see the MAC from vlan 201. With the second config the phone can boot without problems:
interface FastEthernet0/48
description tp-11-voip
switchport access vlan 250
switchport mode access
switchport voice vlan 201
is there a reason, why it is the problem with the first config on cat2960 ? The same first config works with an Cat2950 without problems.
View 3 Replies
View Related
Jan 29, 2013
Switch A is: WS-C2960-48TC-S
Switch B is: SG 300-10MP
Neither switch supports a similiar transceiver module. We are looking at transceiver GLC-SX-MM for Switch A, and MGBSX1 for Switch B all the Layer-1 information (SX / wavelength, Multi Mode, etc.) I am able to find out about the two transceivers seems to match, so would there be any issue by having these 2 "different" transceivers at either end?
View 1 Replies
View Related