Cisco Switching/Routing :: Connect SF200-48 Switch Via Mini-GBIC MGBLX1 Fiber Module To 3750?

Jun 25, 2012

I am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps.  When connected together they do not enable.  Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?

View 2 Replies


ADVERTISEMENT

Cisco Switching/Routing :: WS-X4306 What GBIC Is For Fiber Single Or Multi Mode

Jul 18, 2012

The module  WS-X4306, support  fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?

View 1 Replies View Related

Cisco Switching/Routing :: 2960 - 1GB GBIC Connector Module

Nov 6, 2012

i have a cisco switch CISCO Catalyst 2960S 48 GigE, 4 x SFP LAN Base WS-C2960S-48TS-L for this i need a 1GB GBIC Connector. need right GBIC connector module and ather details

View 1 Replies View Related

Cisco Switching/Routing :: WS-C6513 - Display GBIC Module Info From Within IOS?

Apr 24, 2012

I have a Cisco WS-C6513 switch, with a couple of GBIC module cards in it.  I am trying to display the part number (or model number) of the modules which are inserted into this module card.  How to do that?  I don't want to schedule down-time to pull the module(s) - just to read the label!  :-)
 
This shows me info for the "module card": sh module 9 But this doesn't work: sh module 9/6

View 4 Replies View Related

Cisco Switching/Routing :: C3560 100mb Fiber Module?

Sep 4, 2012

I have a c3560 switch that has two gig fiber modules in it.  I need to uplink fiber to one of these at 100mb.  This is because this port will be rate limited to 20mb and 10 percent is the lowest you can go with the rate limiting command.  Is there a 100mb fiber module i can insert in the 3560

View 1 Replies View Related

Cisco Switching/Routing :: Switch 3550 - Command To Display GBIC In It?

Nov 9, 2011

Is there any command to display the GBIC in the switch because I need to replace 3550 but I have no exact part number

the model is WS-C3550-24-SMI
and try
sh inventory
sh hardware
sh diag
sh module

View 1 Replies View Related

Cisco Switching/Routing :: 3750G (WS-C3750G-24TS-E1U) - Fiber Module Options?

Mar 17, 2012

Got 2 of these switch stacked and there is some changes that we are going to undertake which will require us to utilize the whole 8 or 4 (2 from each switch) SFP ports. Just need some adivce on which particular fiber modules should I procure. Does this switch support 10GB of SFP ?

View 7 Replies View Related

Cisco Switching/Routing :: Catalyst 6506 And 10 GB 16 Port Fiber Module Compatibility

Sep 4, 2012

We have a core switch with the following ios and supervisor engine. Can we add a16 port LR (x2)or  LRM(X2)  ON  the core switch?if not what modifications has to be done?if an ios upgrade is necessary is it a costly affair?At present we have two 1gb up link modules in single and multimode fiber .
 
#sh moduleMod Ports Card Type  Model  Serial No.--- ----- -------------------------------------- ------------------ -----------  1   16  SFM-capable 16 port 1000mb GBIC        WS-X6516A-GBIC     SAL0803T308  2   48  SFM-capable 48 port 10/100/1000mb RJ45 WS-X6548-GE-TX     SAD07500600  5    5  Supervisor Engine 720 10GE (Active)    VS-S720-10G        SAL1439UMZK
#sh versionCisco IOS Software, s72033_rp Software (s72033_rp-IPBASE-M), Version 12.2(33)SXI4a, RELEASE SOFTWARE (fc2)Technical Support: [URL] Copyright (c) 1986-2010 by Cisco Systems, Inc.Compiled Fri 16-Jul-10 19:51 by prod_rel_team
ROM: System Bootstrap, Version 12.2(17r)SX7, RELEASE SOFTWARE (fc1) uptime is 1 year, 27 weeks, 4 days, 23 hours, 30 minutesUptime for this control processor is 1 year, 27 weeks, 4 days, 22 hours, 58 minutes(code)

View 6 Replies View Related

Cisco Switching/Routing :: Switch C3508G-XL Reboot After Plugging A GBIC Adapter

Dec 14, 2011

Everything is in the title...When I plug a GBIC  adapter on a port, my switch reload automatically..! Is it normal, because I did it during production and It disconnects some users.

View 0 Replies View Related

Cisco Switching/Routing :: Possible To Connect SF200-48 To 300Series At 1G Speed Over Ethernet

Jan 15, 2013

I have in my office switch Cisco Small business series SG300 with 50 x 1G ethernet ports. Now I wanna enlarge my network. I want to buy Cisco SF200-48 with 2 x combo Gigabit SFP . My question: is it possible to connect SF200-48 to 300Series at 1G speed over ethernet? Can I use ethernet port on combo Gigabit SFP on SF200 like uplink and connect it to any port in 300Series?

View 1 Replies View Related

Cisco Switching/Routing :: WS C3560E 12SD - Connect Server To Switch Through FC Cable With SPF Module

May 6, 2012

Recently I have faced following problem in my office, We have purchased two new Dell Server Power Edge R910 with built-in 10GB FC Network card. Service tag of this two servers are given bellow.
1. 7D94C2S
2. 6D94C2S
You can can Check specification of this two server from dell website{ URL}
 
We have two CISCO switch and model is given bellow:
Brand: CISCO
Model: WS-C3560E-12SD

We want to connect server to switch through FC cable and both switch have SPF module. But when we connect server to switch, link do not establish even switch and server port light become off.
Then we have tested the following things:
1. Connect server to server through FC cable, it is okay.
2. Connect switch to switch through same FC cable, it is okay.
 
I don't understand why it is not working.

View 5 Replies View Related

Cisco Switching/Routing :: Connect WS-C2960S-48TD-L Switch To WS-X6708-10G-3CXL Module In WS-C6503-E?

Jun 1, 2012

I want to connect WS-C2960S-48TD-L switch to WS-X6708-10G-3CXL module in Cisco WS-C6503-E switch. WS-X6708-10G-3CXL is C6K 8 port 10 Gigabit Ethernet module with DFC3CXL which requires X2 module. on the otherhand, WS-C2960S-48TD-L requires SFP+. Now is it possible to interconnect these two switch interfaces if I use LIU in between. or does WS-X6708-10G-3CXL module supports CVR-X2-SFP+ to use SFP+ transceivers.

View 2 Replies View Related

Cisco Switching/Routing :: 3750 - Fiber Uplink Between Switches

Nov 3, 2011

I have three switches:
 
primary - Cisco Catalyst 3750G-24TS-24
and two SG300-28
 
I need to apply uplinks as follows:
 
3750G-24TS-24 SFP (1) -> SG300-28 (first) mini-GBIC (1)3750G-24TS-24 SFP (2) -> SG300-28 (second) mini-GBIC (1)SG300-28 (first) mini-GBIC (2) -> SG300-28 (second) mini-GBIC (2) 
 
I would like to know, What type of mini-GBIC and SFP and cable I should use for SX Multimode?What max speed rate I will get?  

View 8 Replies View Related

Cisco Switching/Routing :: 3750 - Way To Connect Another Switch

Dec 9, 2012

is it generally possible to connect another switch, such as a 3750 to a port of a fabric extenders (C2232PP-10GE)?

View 1 Replies View Related

Cisco Switching/Routing :: 3750 Switches With All Optical Fiber Ports?

Feb 14, 2013

We have a scenario where we want to connect 14 access layer  2950 switches to Core switch 3750 via optical fiber in a LAN.What model of 3750 Switch should we use to tackle this situation.I have learnt that WS-C3750X-24P should support it.Isnt it?
 
Can we use optical fiber SFP module to connect 2950 switches to core switch?Does Cisco 2950 Switch support optical fiber sfp module?

View 2 Replies View Related

Cisco Switching/Routing :: 3750 Using Fiber Connection Using Patch Panel

Apr 2, 2013

I have a 6500 connected to 3750 using fiber connection using patch panel.on the gig port of the 6500 give of error in Input errors, CRC and FRAME.There is no error from the 3750 gigport.

View 6 Replies View Related

Cisco Switching/Routing :: 3750 - How To Isolate Fiber Port Traffic

Jun 18, 2012

We would like to setup a link to our DR site that is separate from our main network traffic.  This link will be used by an EMC VNX SAN for replication traffic.  The SAN will be plugged into a fiber port on a 3750 switch and going out from the same switch (going in as multimode, going out as single mode) into a patch panel that runs over to the DR site (about a mile away).  At the DR site it will go from the fiber panel into another 3750 switch which ends up going back out of that switch into our DR SAN.
 
I'm wondering what the best way would be to configure the fiber ports to accomplish this.  I'm affraid that the replication traffic will find it's way over through another route and congest our main network unless configured appropriately.

View 4 Replies View Related

Cisco Switching/Routing :: Connect Nexus5k With 3750 Switch?

Jan 13, 2013

What is the most cost effective way of connecting a Nexus 5k with a 3750, Apparently we cannot use 7 and 10 meter twinax cables to connect the 3750 switches to Nexus 5Ks.

View 2 Replies View Related

Cisco Switching/Routing :: Single Mode Fiber Support For WS-3750 Switches?

Mar 5, 2012

I'm looking for switches that support single mode fiber connections and would like to know if "WS-C3750-FS-S Catalyst 3750 24 100BaseFX + 2 SFP" and "WS-C3750G-12S-S Catalyst 3750 12 SFP" can serve the purpose?

View 6 Replies View Related

Cisco Switching/Routing :: 3750 Connect Stack Cables To New Switch

Dec 11, 2011

At a customer i've tried to add a new 3750 switch til a running stack.I used the following proccess:
 
1. connect stack cables to the new switch

2. bootup new switch.
 
Normally the new switch will become a member of the stack, but here, the switch says its the stack master. I can see that the stack port from the old switches connecting the new is up.The only way i could make it work was to provisioning the new switch as switch nr x, save, power off and then connect it and boot it up.The IOS i the same on all switches.

View 2 Replies View Related

Cisco Switching/Routing :: Use Both Interfaces On 2921 To Connect To 3750 Stack Switch 1 And 2

Nov 9, 2012

I have a Cisco 2921 and a 3750 stack. I want to use both interfaces on the 2921 to connect to the 3750 stack switch 1 and 2. Is this possible using same ip subnet?

View 2 Replies View Related

Cisco WAN :: 6509 What GBIC Is Installed On Sup2 Right Now Where Fiber Cable Is Connected

Feb 7, 2011

We have a 6509 Sup2 at our ISP edge with fiber connection to ISP. I am planning on replacing the 6509 either with 7206VXR-GE2 or ASR 1002.
 
How do I find out what GBIC is installed on my Sup2 right now where Fiber cable is connected?What GBIC/SFP will be compatible for this on 7206VXR or ASR1002?If I use SFP do I need to change the cable connector?

View 5 Replies View Related

Cisco Switching/Routing :: 3750 Get Rebooted And Now SFP Module Is Not Working

Mar 19, 2012

In my Cisco 3750 get rebooted and now the SFP module is not working.
 
It showing the following error message.
 
05:13:22: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP inte
rface Gi1/0/26 
05:13:22: %GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for GB
IC in port Gi1/0/26
 
What is the error message indicating and what is the solution for this.

View 1 Replies View Related

Cisco Switching/Routing :: Recommendations For A 3508-XL Fiber Switch Replacement

May 22, 2013

This is an easy question for all the architechs and designers out there. I have a stack of 3508-XL switches and one of them failed. we have 2 spares but hese are more than 10 years old and have reaced EoL.What is the equivalent switch of a 3508-xl replacement today?

View 11 Replies View Related

Cisco Switching/Routing :: Is It Normal To Have All Ports 4500 Switch (not Fiber Ones)

Apr 24, 2012

I was checking some things on my Cisco 4500 and spot checking some of the ports. Using CNA it says it is at 10. The web browser to the switch says Full-duplex, 1000Mb/s, link type is auto, media type is 10/100/1000-TX on port 6i/18 The CNA says, so what would cause the difference?

View 3 Replies View Related

Cisco Switching/Routing :: 3750 C3kx-nm-1g - Network / Copper Module For It

Oct 18, 2012

For the c3kx-nm-1g network module it looks like it will take the standard sfp's for fiber but I need copper rj45 connections, is there a copper sfp for this?

View 1 Replies View Related

Cisco Switching/Routing :: 4507R-E Switch - How To Add Extra 10 Gbps Fiber Link

Sep 30, 2012

We are using CISCO 4507R-E switch as our core/distribution switch. Out of the 7 available slots, 3 are currently being used. Descriptions is as follows:

       Slot 1: 6 Port Fiber Line Card
 
       Slot 2: 6 Port Fiber Line Card
 
       Slot 3: Supervisor Engine
 
       Slot 4: Empty
 
       Slot 5: 48 Port Copper Line Card
 
       Slot 6: Empty
 
       Slot 7: Empty
 
We want to add extra 10 Gbps fiber links (approximately 12) using slot 6 and 7.

View 6 Replies View Related

Cisco Switching/Routing :: 3560 - Connecting Fiber To HP 2510-48 Port Switch

Feb 19, 2012

In one location we have a HP 2510-48 port switch which we need to connect to a Cisco 3560 switch. The problem I have is that we have issues connecting fibre to the HP switch, so I have decided to attached a CAT 5 to Fibre convertor at this end and another to the cisco switch.
 
My question you can not connect a HP switch to a Cisco switch, is this true or do I just need to confirgure something on the ports.

View 2 Replies View Related

Cisco Switching/Routing :: Cascade A (fiber) Dell Switch To Nexus 5000?

Dec 11, 2011

Is it possible to cascade a (fiber) Dell switch to Nexus5000 as shown above ?

View 4 Replies View Related

Cisco Switching/Routing :: 3750-x / Separate Module To Enable Stackwise And Stackpower?

Aug 22, 2012

As I understand Cisco Catalyst 3750-x supports stackwise and stackpower technology.Do I need to purchase a seperate module to enable stackwise and stackpower? Or are stackwise and stackpower modules included be default on the switch already?

View 4 Replies View Related

Cisco Switching/Routing :: 3750-X Way To Get NetFlow Support Is To Install Specific Module

Sep 17, 2012

I've been researching the 3750-x Netflow support but I'm not 100% sure of how much support it has. From what I've read the only way to get NetFlow support is to install a specific module that provides NetFlow. I also heard about how it might support s-flow but I haven't found out for sure.

View 8 Replies View Related

Cisco Switching/Routing :: Inter Access Switch Fiber Connectivity 2960-48PS

Jan 16, 2012

I had a strange issue yesterday when onsite installing a new access switch.Port capacity full on a two switch stack of 3750 x48 PS switches (WS-C3750- 48PS-E)- New 2960 x48 PS - WS-C2960S-48FPS-L racked, with the plan of using it just as an edge switch via SFP Stacking cable.Setup the two connecting ports with simple initial config: - switchport mode trunk- no encapsulation option on the 2960, default dot1q- dot1q set on 3750 port- no shut on both sides.Connected the SFP Stacking cable but it didnt work:- %PHY-4-SFP_NOT_SUPPORTED: The SFP in Gi1/0/1 is not supported
 
This is ok as I had a backup:- Next step tried using 2 x Short Haul SFP SX GBIC's with LC - LC OFNP 50/125 fibre patch lead  - no joy- Extra backup of 2 x Long Haul SFP LX GBIC's with the same fibre patch - no joy- Checked the fibre and it was not a cross over so transmit and receive going down the same side, switchedand still would not come up.- Used Fibre as a straight through and still the same.In all cases there was no indication of any life in the connection.It is pointing to a faulty fibre patch lead but I know it has worked in the past. Could it be something to do with the config or device incompatibility? Or any setting I need to activate?

View 1 Replies View Related

Cisco WAN :: 3750 - Use Two Core Switch 6500 With Single Mode Fiber As Transport Equipment?

Nov 30, 2012

I have a requirement to connect two 3750 switch with 10G speed between two sites with 150km distance. We will lay-out our own fiber (48 core) between two sites. I just want to consult the following:
 
1. Could i use two core switch 6500 with single mode fiber as a transport equipment?

2. Or i need to use SDH equipment because of the distance concern? If so do i need a repeater?Could i use Cisco Metro Core ONS, which one?

3. Any other option to achieve this requirement?

View 4 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved