Cisco WAN :: 6509 What GBIC Is Installed On Sup2 Right Now Where Fiber Cable Is Connected

Feb 7, 2011

We have a 6509 Sup2 at our ISP edge with fiber connection to ISP. I am planning on replacing the 6509 either with 7206VXR-GE2 or ASR 1002.
 
How do I find out what GBIC is installed on my Sup2 right now where Fiber cable is connected?What GBIC/SFP will be compatible for this on 7206VXR or ASR1002?If I use SFP do I need to change the cable connector?

View 5 Replies


ADVERTISEMENT

Cisco Switching/Routing :: 6509 / Layer 3 Port Channel Between Sites Connected Over Dark Fiber?

May 21, 2013

Has anyone configured Layer 3 port channel on Cisco 6509 switches which are connected over dark fiber between two buildings?

View 3 Replies View Related

Cisco Switching/Routing :: WS-X4306 What GBIC Is For Fiber Single Or Multi Mode

Jul 18, 2012

The module  WS-X4306, support  fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?

View 1 Replies View Related

Cisco Switching/Routing :: Upgrade SUP2 To SUP32 On 6509?

Sep 18, 2012

I am going to upgarde SUP2 to SUP32 on my 6509 by next week. right now I have 2 SUPs on the 6509 in redundant mode.

View 5 Replies View Related

Cisco Switching/Routing :: 6509 / Sup2 To Sup32 Upgrade?

Oct 7, 2012

I need to upgrade 2xsup2 module to 2xsup32 on my cisco 6509. I just found out that I can not have the CISCO WS-X6500-SFM(Cisco Switch Fabric Module switch) with Sup32 and I have to remove 2 xCISCO WS-X6500-SFM2 modules from the switch.I am using this switch as a access switch and most of the ports are 100Mbps.
 
let me know if the upgrade would be safe or not as far as the bandwidth?

View 2 Replies View Related

Cisco Switching/Routing :: Connect SF200-48 Switch Via Mini-GBIC MGBLX1 Fiber Module To 3750?

Jun 25, 2012

I am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps.  When connected together they do not enable.  Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?

View 2 Replies View Related

Cisco Switching/Routing :: GBIC On 6509

Nov 7, 2011

I have an interesting problem. I have a 6509 that I'm trying to swap the GBIC on. The switch is already using a GLC-SX-MM GBIC and it is up/up and passing traffic, but we are getting some errors and suspect it may be faulty. 

I want to replace the GBIC with one of the identical model - a GLC-SX-MM. It was brand new, never been opened. When the new GBIC is plugged in the link light on the switch goes completely off (not amber) and the port goes into a down/down (not connect) state. There are no messages in the logs at all. It's like it doesn't even see it. If you plug the old GBIC back in then the link comes back up. I tried a different port with the same results.Thinking that the new GBIC may be faulty (even though it was brand new) I tried a second GLX-SX-MM, also new. That one does the same thing. 

At that point I thought there might be a problem with that switch, so I tried the GBICs on the other 6509 in that pair. The other 6509 is running the same hardware and software. The GBICs will not work there either. If you move the old, suspected faulty GBIC from 6509-2 to 6509-1 then that it works. 

The solution would seem to be that I have two faulty GBICs, but I'm having trouble persuading myself that I have two new ones, straight out of the package, that are both bad. Are there any other things to check on the switch? Here's the pertinent information: 

switch#show ver
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXI3, RELEASE SOFTWARE (fc2)
<snip>
cisco WS-C6509-E (R7000) processor (revision 1.3) with 458720K/65536K bytes of memory.
Processor board ID SMG1109N3BK
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
[code]...

View 15 Replies View Related

Cisco Switching/Routing :: Fiber Link Between Nexus And 6509 Not Working

Apr 27, 2013

I have the following connectivity :Nexus(7004) - M1 8Port card with  x2-10GB-SR <---------------------->  6509 -- 6704 card -- xenpak-10GB-SR  ,The fiber link is not coming up.

View 4 Replies View Related

Cisco Switching/Routing :: Add Another Fiber Redundant Link Between 6509 And 2960 Stack?

Jan 6, 2012

below is the current config of link that is already up. I need to add another fiber redundant link between 6509 and 2960 stack. How to work on config Spanning side by not taking 6509 down after the change. 6509 is in distribution.
 
---------------X-ALPHA-IDF-1FORMS-2960S-0# (SIDE)
!interface GigabitEthernet1/0/52description X-ALPHA-F-6509-0 uplinkswitchport trunk native vlan 18switchport mode trunksrr-queue bandwidth share 1 50 30 19priority-queue out mls qos trust dscpmacro description cisco-routerauto qos trust spanning-tree portfast disablespanning-tree guard loopip dhcp snooping trust!
 
-----------------X-ALPHA-F-6509-0# (SIDE)
!interface GigabitEthernet3/10description 1st floor POC2 Forms IDFswitchportswitchport trunk encapsulation dot1qswitchport trunk native vlan 18switchport mode trunkno ip addressmls qos trust dscpspanning-tree guard loop!

View 1 Replies View Related

Cisco Switching/Routing :: 3750X / 6509 - Trunking Over Single Mode Fiber

Oct 26, 2011

I'm having a problem with some new gear and can't seem to figure it out.  I have a 3750X-48P-S with a C3KX-10G-NM using SFP-10G-LR transceivers and I'm trying to trunk that with a 6509 that has a X2-10G-LR transceiver over single mode fiber.  This is not working.  Cisco TAC says the SFP+'s that we just got brand new are both bad and we need to order new ones.  I find that hard to believe but who knows.
 
The switch recognized the module and I tested all 4 ports in gigabit mode using GLC-SX-MM transceivers, all worked great.  I have the SFP+'s in tengig1/1/1 and 1/1/2 as they should be.  There are no other SFP's in the module either.
 
When I do a sho int tengig1/1/1 and 1/1/2 the media type doesn't show the transceiver that is installed like it does for the GLC-SX-MM ones.  Maybe it's not supposed to or maybe it just doesn't recognize them and it's a hardware issue.

View 5 Replies View Related

Cisco Firewall :: FSWM Active / Standby Installed In 6509-E Core Switches

May 9, 2011

I have FSWM active/standby installed in 6509-E core switches running following FWSM Firewall Version 3.1(3) Device Manager Version 5.0(2)F..I want to upgrade to latest FWSM version as well as ASDM, I downloaded asdm-622f.bin and c6svc-fwm-k9.4-1-5.bin from cisco portal. When i checked the show version of FWSM, it says..The Running Activation Key is not valid, using default settings: Running Activation Key: 0x00000000 0x00000000 0x00000000 0x00000000
 
I have gone through threads on CSC about how to upgrade FWSM in failover mode, now my concern is, Do i have to take care about activation key or keep as it is ? I have maintenance contract with cisco for all devices.

View 3 Replies View Related

Cisco Switching/Routing :: 2811 Port Is Connected To Fiber Or Copper

Jan 14, 2013

I need Know what connection is using on Cisco 2811 router.I have this interface in Cisco 2811, I need Know if this port is connected to Fiber or Copper. I think is copper with RJ45 but I see 100 base TX/FX so this make me doubt about it because TX its for copper link and FX for fiber. [code]

View 5 Replies View Related

Mix Fiber Optics And Cable In A Home?

Sep 3, 2012

I have had fiber optics for phone, TV, and internet (30/30 speed). They upped the price 80%! I would like to keep my internet on fiber optics but drop TV and phone to cable which is cheaper. Can I have both systems simultaneously? Also, we have a Sony L-series TV/Computer. IT's a TV and computer in one. Can we have both fiber optics and cable attach to it at the same time?

View 2 Replies View Related

Cisco :: Conditioning Cable For Multimode Fiber Link?

Feb 12, 2013

An external company is going to deploy multiple fiber links on my campus.Link distances vary from 120 to 400 meters.I already have the switches in production with spare SFP gigabit ports on the locations.The backbone is gigabit, so I asked them to use GLC-LH-SMD SFP modules.So, they just called me and according to them, the minimum distance for MMF links with that SFP module is 550 meters. I checked Cisco's website and it says "up to 550m"?

View 6 Replies View Related

Cisco LAN :: 6506 How To Connect Fiber Cable To Switch

May 14, 2012

The core switch is a 6506 and one of the modules is the 48port POE module. The 6506 resides in the main building and we need to interconnect two other annexes to the main building via fibre. is it possible to have just 2 sfp ports on the 48 port module or how to connect the fibre cable to the switch?
 
 Also, if the existent network is made up of Cat5e cables would it be of anyuse to use Cat6 cables for uplink for the switches on each segment to the core switch. I feel basically the Cat5e would nullify the speed of the Cat6 or am i  wrong and this would make uplink speed faster.

View 10 Replies View Related

Linksys Cable / DSL :: How To Connect Fiber Box To X3000

Apr 2, 2013

I have X3000 home gateway and very happy with this device. Use it now as ADSL modem/wifi router. Everything works fine but there is something I do not understand about this device.It has 4 LAN ports and a Cable port. Suppose, I am upgraing from a copper service to fibre. Fibre providers comes and installs their fibre box which is kind of a "modem" for fibre technology. how do I connect fibre box to X3000? Do I use Cable port or a LAN port?
 
As far as I understand the 4 LAN ports work as switch ports (work at OSI level 2, provide access strictly within same subnet, all devices connected to these ports share the same default gateway), and Cable port gets a different IP address via DHCP or another protocol from the fibre box, or directly from ISP (if we have PPPoE or IPoE service as an example). And there would be no point in plugging WAN link into a LAN port as X3000 would not be able to communicate to the gateway on the other end of the cable.

View 1 Replies View Related

Cisco Routers :: RV016 Unable To Get Cable Nor Fiber Services

Feb 9, 2013

We recently moved to a new office and currently have three ISPs(DSL, SAT, 4G) because we are unable to get Cable nor Fiber services.  We have anywhere between 7-20 Remote Desktop connections(with lot of file transfers) and 8 VOIP lines.  Basically, we need to bind certain services to specific WAN links in order to make everything work somewhat decent because of the limited bandwidth and/or latency of each ISP.
 
I would like to double check if the bindings are working for the specific services, and it has been difficult to verify if the settings in the RV016 are working.  I believe it's not working 100%, and I need a way to check and make sure that my settings are being followed.
 
What would be the best way to check the current connections to see if the service is being routed via the WAN link specified in my setting?  My RV016 is HW ver 3, but not the latest firmware.  Purchased about 2 months ago.

View 4 Replies View Related

Cisco Switching/Routing :: WS-C2960S-24TS-S / What Type Of Fiber Optic Can Be Connected To New Switches

Jan 16, 2012

find out which types of fiber optic that i can connect to three types of switches. the setup that i have that there are:8 access switches (WS-C2960S-24TS-S), in each one there is two SFP connections.2 aggregate switches WS-C3750X-24T-S, in each one there is four SFP connections.and one core switches that has SFP card  WS-X4624-SFP-E? Note that the fiber optic that we have coming from filed are multimode.

View 2 Replies View Related

Ethernet Cable Not Detected After New Service Installed?

May 14, 2012

I switched from DSL to cable about a week ago, I have two desktops connected via ethernet cable to the modem. One works fine, the second stays connected for 5 seconds, disconnected for 5 seconds, connected, again, etc until the system is on for 45 minutes or so and then it stays connected. I feel like it is probably a setting and that the system is trying to detect something during that time. Problem is I have no idea where to start and Comcast is totally useless. I have already replaced the cable because that's what they said the issue was, it wasn't.

View 2 Replies View Related

Linksys Cable / DSL :: What Chipset Is Installed In X3000

Sep 26, 2012

What chipset is installed inside linksys X3000 router? I tried, but i can't find this:/

View 2 Replies View Related

Cisco Switching/Routing :: WS-X6816-10G-2 Connecting SMF Fiber Cable To A MMF Port

Dec 12, 2012

I have a WS-X6816-10G-2T module with X2-10GB-SR modules. I will be getting a SMF hand off and the length of the termination is around 100 meters. (I will be getting another hand off for Inter-DC link for which I have X2-10GB-LR module). The question is can I connect this SMF hand off (short length) on the SR module?

View 2 Replies View Related

Cisco Switches :: Minimum Fiber Patch Cable Length For MGBSX1

Dec 14, 2011

I want to "stack" a couple 300 series gigabit switches with fiber using a pair of MGBSX1 GBICs and a single LC to LC patch cable.Is there a minimum supported patch cable length in this configuration?

View 2 Replies View Related

Cisco Switching/Routing :: 2960 - Connecting Two Switches Using Fiber Cable

May 25, 2013

I need to connect 4 Floor Building with 4 Cisco 2960 - 48 ports switch each other and it needs to be through a fiber. So all PCs connected to each switch would reach the LAN/WAN from the other switch. (attached is the image here with)
 
I see that the 2960 has 2 SFP ports each port of each switch should connect each other or how?
 
My simple question is:
 
1. What cable / patch code I have to use = Single-mode or Multimode? ( distance for each switch will not more then 25 mts)

2. Do I have to use SFP or SFP+ module?

3. What kind of SFP/SFP+ module I have to use = Single-mode or Multimode?

4. What kind of connector should patch code have = LC / SC or ?

5. How to connect each switch with redundancy like ...each switch should be interconnected with each other or I have to choose Cisco 3750G which has more then 2  SFP ports (option#1 & opetion#2 = attached here with) =

Best practice for connecting cisco switches over fiber.

View 10 Replies View Related

All Substations Is Link With Fiber Optic Cable Throw Switches?

Jan 24, 2012

I have 4 workstation at 4 different power substations. Each substation have switches. All substations is link with fiber optic cable throw switches. Each substation has 100 relay (IED) with different IP address it connect with substation switches. The IP address of substation is[CODE]

View 1 Replies View Related

Cisco Switching/Routing :: Connect PC With Fiber Cable On Supervisor WS-X45-SUP6L-E Of 4500E?

Feb 23, 2012

I have a problem connecting a PC in a TwinGig Convertors (GLC-LH-SM). I want to connect a PC with a fiber cable on the supervisor WS-X45-SUP6L-E of my Switch 4500E.
 
The default configuration mode is X2. As I want to deploy Gigabit interfaces (that is, use TwinGig Convertors), then I configured the associated port-group:
 
Switch(config)#hw-module module 1 port-group 2 select gigabitethernet
*Feb 24 06:18:37.125: Port Te1/2: TwinGig Converter inserted: vendor: CISCO
 Switch(config)#do sh int status mod 1                     
 Port      Name               Status       Vlan       Duplex  Speed Type

[code]....
 
I noted that the Swicth set up automatically 'switchport mode trunk', so i put the command 'swicthport mode access' because i want to connect only a PC. But the status is the same, I can not achieve connectivity. i just want to know how connect a PC in the interface GigabitEthernet1/4 of the supervisor engine of my Switch.

View 3 Replies View Related

Linksys Cable / DSL :: Configuration Of WAG54G2 On Etisalat Adsl Fiber Optic?

Sep 30, 2011

correct settings > Configuration of WAG54G2 on etisalat adsl fiber optic

View 1 Replies View Related

Linksys Cable / DSL :: WAG320N With 100 Mbps Fiber Is Not Establishing Full Duplex Connection

Feb 26, 2011

I have 100 mbps fiber connection. I bought 320N today I bought 320N and here is the problem:
 
We have a switch in the building. I am getting connection via CAT5. So I choosed "Use as WAN Port" from Ethernet settings. There is not much you can do here. I just used PPPoE and connected internet without any problem. The problem is I am only getting 32mbps. When I connect CAT5 cable directly to my computer I am getting 92mbps.
 
Maybe WAG320N is not establishing a full duplex connection.

View 3 Replies View Related

Cisco Wireless :: 6509 IPads Not Staying Connected To APs

Apr 19, 2012

All, I am the wireless administrator for a rather large school district in Oregon, and we are seeing numerous issues with iPad's connecting and staying connected to our lightweight AP's in an HREAP configuration.  Our iPad carts have about 20 iPads a piece and an AIR-LAP1142 supporting them.  We have no issues with getting non-Apple products to connect and stay connected, but for some reason the iPads are creating a major issue.  We currently run 8 4400 WISM blades via two 6509's, running code 7.0.116.0.Our AP's are running 7.0.116.0 as their primary software and their IOS is 12.4(23c)JA2.

View 12 Replies View Related

Cisco Infrastructure :: 2 6509-E Switches Connected Directly To Each Other While Using VRF-lite (Sup 2T)?

Apr 11, 2013

I am trying to test (if possible) the idea of having 2 6509-E switches connected directly to each other while using VRF-lite (Sup 2T). The idea is to have 3-4 separate networks. For example Net-A, Net-B,Net-C, Net-D. There is no PE router*, just these two switches. Also, there sin't any other access layer switches. All users connect directly to the 6509-E's via switch 48 port switch blades.  
 
Net-A and Net-B on separate VRF's, but able to talk to each other. Net-C and Net-D* on separate VRF's without being able to talk to any other. Net-D* will have a PE since it comes from an external network. This is something I would like to test in a lab environment, but I am not familiar with VRF's.

View 1 Replies View Related

Cisco Switching/Routing :: Load Led Indicator On WS-X6k-SUP2-2GE

Oct 29, 2011

I have cisco catalyst 6509 with 2 x WS-X6k-SUP2-2GE. on the supervisor module is a switchload led indicator . I switch has never load according to load indicator.
 
Do i need to enable this in the switch config. The switch is running catos

View 2 Replies View Related

Cisco Switching/Routing :: L2 Tunneling 4503 SUP2+TS?

Sep 16, 2012

I need to implement over an ethernet link L2 tunnel because I want to isolate another VLANs domain.On the first side I can use the command : sw mo dot1q-tunnel on a new C4503 on the other side I cannot configure the command : sw mo dot1q-tunnel.
 
the other side is an old C4503 we upgrade the flash with a compact flash to upgrade to a new IOS v15 but the command doesn't exist also.I red the cisco feature navigator feature and I am sure the dot1Q-tunnel is available on my image : cat4500-ipbasek9-mz.150-2.SG.binso I don't know why I can use it.

View 1 Replies View Related

Installed AVG 2011 And AVG PC Tune-up 2011 - Connected Internet But Can't Use

Feb 21, 2011

I recently Installed AVG 2011 and AVG PC tune-up 2011. When i just start my computer the internet is working fine, but after a open my game Flyff, The internet is still connected but cannot use it.

View 2 Replies View Related

Cisco Switching/Routing :: 6500 - WS-X6K-SUP2-2GE - TCAM Exhaustion?

Nov 11, 2012

we have a WS-X6K-SUP2-2GE running CATOS software, we are facing a TCAM exhaustion.I would like to know the following:

1. during an exhaustion, based on what ACLs will be kept in hardware or moved to software? the name or number gives any precedence to an ACL over another ACL?

2. If the TCAM's utilisation was on the limit and we increased ACEs to a specific ACL, all the ACL will be moved to software or only the new entries?

View 1 Replies View Related