Cisco Switching/Routing :: 3750 C3kx-nm-1g - Network / Copper Module For It
Oct 18, 2012
For the c3kx-nm-1g network module it looks like it will take the standard sfp's for fiber but I need copper rj45 connections, is there a copper sfp for this?
View 1 Replies
ADVERTISEMENT
Aug 14, 2012
I know that the C3KX-NM-10GT network module has two (copper) ports that support speeds of 1Gps or 10Gps. Could this module work with one port at 1Gb and the second port at 10gb simultaneosly? It's possible to work each port of the module with different speed (one port working on 1Gb mode and the other working on 10Gb mode)?
View 1 Replies
View Related
Feb 20, 2012
confirm the C3KX-NM-10G module is hot-swappable.i have checked the cisco's website and it says " Although network modules are hot-swappable, we recommend installing a network module before powering the switch"
What steps i need to follow to install the module?
View 5 Replies
View Related
Dec 29, 2011
A product I could have used a number of times is a expanded version of the C3KX-NM-1G device module. To include 2 or maybe 4 more SFP ports. From the layout behind the faceplate there is plenty of space which additional circuit boards could be placed, (which is used in the 2 port 10GB version). I don't need the 12 port fiber switch that Cisco has, because I need a few RJ45 connection at that location, which I would then have to buy additional Fiber to coper Gbics for a few connections where the switch is at. The reason I need something like this is I have a few locations which I get a main feed from the City fiber, then it gets sent out to a number of local buildings on my fiber. Maybe another option is to take the 12port switch, and have an option for 6 rj45 and 6 sfp connections.
View 8 Replies
View Related
Dec 19, 2012
I was trying to get a visio stencil for C3KX-NM-1G module but it doesn't seem to exist. It indeed does not exists or I just can't find it.
View 2 Replies
View Related
Jul 29, 2012
I have a 3750-x switch with module C3KX-NM-10G. In slots 1 and 3 I have GLC-T inserted, no problem. When I try to insert GLC-T into slots 2 or 4, I receive the log messages that are listed below. I can swap/mix and match different GLC-T's in slots 1,2,3, and 4, the SFP's are recognized every time in slots 1 and 3, and are never recognized in slots 2 or 4.
Slots 2 and 4 also double as the Ten Gig interfaces, which we are not using right now.Is there some trick to getting the switch to recognize SFPs in slots 2 and 4? [code]
View 6 Replies
View Related
Mar 19, 2012
In my Cisco 3750 get rebooted and now the SFP module is not working.
It showing the following error message.
05:13:22: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP inte
rface Gi1/0/26
05:13:22: %GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for GB
IC in port Gi1/0/26
What is the error message indicating and what is the solution for this.
View 1 Replies
View Related
Aug 22, 2012
As I understand Cisco Catalyst 3750-x supports stackwise and stackpower technology.Do I need to purchase a seperate module to enable stackwise and stackpower? Or are stackwise and stackpower modules included be default on the switch already?
View 4 Replies
View Related
Sep 17, 2012
I've been researching the 3750-x Netflow support but I'm not 100% sure of how much support it has. From what I've read the only way to get NetFlow support is to install a specific module that provides NetFlow. I also heard about how it might support s-flow but I haven't found out for sure.
View 8 Replies
View Related
Jun 25, 2012
I am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps. When connected together they do not enable. Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?
View 2 Replies
View Related
Jul 17, 2012
I have connected 2 SG500x switches using an SFP-H10GB-CU1M SFP+ Copper Cable module. Since the port shows as a 10G port, I would expect the speed to show as 10G as well. However, it shows as "Unknown". This doesn't leave me with confidence that it is being recognized properly. The link is working properly, but I haven't run tests to verify if I'm getting full 10G throughput or not. Shouldn't it show 10G as the link speed?
View 12 Replies
View Related
Sep 3, 2012
We need to deploy a 3750X switch with 10 Gb module. The pb is what SFP to choose ? The 10 Gb ports will be attached to an ethernet 10 Gb RJ-45 Server port. The 10 Gb connection has to be copper (not fiber). Is this reference ok : SFP-H10GB-CU3M= (version 2) ? I mean is it a copper cable with an attached SFP.
View 5 Replies
View Related
Jun 4, 2013
I have C3750X with C3KX-NM-10G, and have-T SFP in slot 3 ( means it is not in SFP+ slot ).I need to set speed&duplex hard to 100/Full, but if I do the link goes down. I have the same settings on the other side, only IOS version is different.I tried other speeds - 10 and 1000, but no one works with Full. When I change duplex to Auto it works fine.The reason why I am doing this on C3KX-NM-10G is because I need to use NetFlow and cannot use the chassis' copper port. At the moment the ports are connected through a copper patch cord, but in full production there will be a radio link in between that requires 100M/Full to be set hard.I am trying to search for any document that would describe this limitation, but cannot find any. Also port capabilities do not indicate duplex could not be set to full:
show interfaces g1/1/3 capabilities
GigabitEthernet1/1/3
Model: WS-C3750X-48P
Type: 10/100/1000BaseTX SFP
Speed: 10,100,1000,10000,auto
Duplex: half,full,auto
Trunk encap. type: 802.1Q,ISL
[code]....
View 5 Replies
View Related
Mar 5, 2012
Is the C3KX-PWR-1100WAC= compatible with the WS-C3750X-24P-S?
View 1 Replies
View Related
May 12, 2012
I am trying to connect tow 3560X using a fiber cable (MM)I have C3KX-NM-10G in both switches (4 ports module)I have GLC-SX-MM in both switches (connected to G1/1)both switches are able to see & recognize the NM as well as the SFP.
Fiber Cable is tested Fiber Patch Cord also tested both ports configured as a trunks but also the switches are not able to see each other (even when I removed the trunks configuration from both of them)CDP neibour is showing nothing no links & no LED blink in any switch both switches are running c3560e-universalk9-mz.122-55.SE3 IOS?
There is no any other configuration in both switches.
View 5 Replies
View Related
Oct 2, 2012
I have a Catalyst WS-C3750X-24T-S with two power supply C3KX-PWR-440WDC, each of these power supply have two input to deliver 440 W, my question is: Can I use only one Input in each power supply to power up the switch?, I know that I dont going to get the total power of 440W, but the power delivers by the supply with one input circuit is enough to power up the switch condidering that the switch are not PoE and only have 24 ports?.
View 3 Replies
View Related
Oct 26, 2011
I've put a C3KX-NM-1G module into a 3750x but can only get ports 1,3 to stand up, ports 2 and 4 dont operate. ports 2,4 are not shutdown and dont come up with working SFPs etc in another switch.
View 1 Replies
View Related
Jan 14, 2013
I need Know what connection is using on Cisco 2811 router.I have this interface in Cisco 2811, I need Know if this port is connected to Fiber or Copper. I think is copper with RJ45 but I see 100 base TX/FX so this make me doubt about it because TX its for copper link and FX for fiber. [code]
View 5 Replies
View Related
Aug 9, 2012
We have WS-C3750-24FS switches stacked supporting users on our LAN. I want take advantage of the netflow capabilities of the WS-C3750X using the C3KX-SM-10G card.
Would I be to see netflow data coming from the WS-C3750's if I stacked it with the WS-C3750X?
Also I read that the C3KX-SM-10G card would support a 1G SFP is that correct?
View 1 Replies
View Related
Feb 4, 2012
I have a situation where two of my CGS-2520-16S-8PC switches are not applying POE power to the copper ports, but showing power inline, two ports are showing power applied. Shutting down the port and re-enabling it will return the port to normal and the phone will connect.
I'm running cgs2520-lanbasek9-mz.122-58.EY2 after using 122-58-se1. Happening on both, but i have more switches running EY2 with no issues at the moment. Using DC power supply averaging around 53v.
View 9 Replies
View Related
Sep 5, 2012
our network is spread over 15 floors and each floor we have 5-6 switches. we are planning to purchase cat3750-x 24 ps poe with C3KX-NM-10G network modules. Each floor has two up links to the core switch with single mode fiber and other being the multimode.Suppose if we are purchasing 75 switches do we have to purchase 75 C3KX-NM-10 G modules.? or can we limit our purchase with 15 C3KX-NM-10G sothat two uplinks from each floor can be made? since network modules are optional cost factor is invovled. Or any issue with stacking ? the SFPs will be LR and LRM MODULES.looking for an answer ? whether the new usb type console cable comes bundled with cat350x or shall we have to order separately?
View 7 Replies
View Related
Dec 19, 2011
Is there a switch that handle its 24/48 ports at 10 Gbps with copper?. I have checked 3750 X but just handle 2 SFP with 10 Gbps.The requirement is to use this switch as CORE and connect 12 switches (access) using its uplinks at 10 Gbps with copper ( in this case 3750 X can be used).using copper at 10 Gbps the distance is still 100 m?
View 9 Replies
View Related
Jan 5, 2012
I need to connect one sw3750E with two 3750X , with Uplinks at 10 GBps. My doubt is the next:
Switch 3750E has two TwinGig Adapter Converting 10 Gigabit Ethernet X2, phisically each twinGig adapter has 2 slots for SFP modules. Can I install sfp+ If I want to use copper for Uplink at 10 Gbps, I just need to install one SFP-H10GB-CU5M transceiver ???? the other SFP slot is disabled automatically?
in the other side 3750X in order to support copper at 10 Gbps a C3KX-NM-10G network module is considered, this will be connected to SW3750E by means of SFP-H10GB-CU5M.
The second 3750X will be connected to second twinGig Adapter of 3750E using another SFP-H10GB-CU5M transceiver.
View 7 Replies
View Related
Mar 17, 2013
Is it possible to connect 3750X with C3KX-NM-10G to X2 10G port on sup2t in 6500E switch.There is Cisco OneX Converter Module, but I could not find that it is supported on sup2t.
View 2 Replies
View Related
Jun 9, 2013
I have a problem between two switches with ether channel configured:
Model number : WS-C2960S-24TS-L
System image file is "flash:/c2960s-universalk9-mz.122-58.SE2/c2960s-universalk9-mz.122-58.SE2.bin"
Gi1/0/23 ETH-CH_1_SW-EDGE01 err-disabled trunk auto auto 10/100/1000BaseTX
Gi1/0/24 ETH-CH_2_SW-EDGE01 connected trunk a-full a-1000 10/100/1000BaseTX
Po1 Trunk_SW-EDGE01 connected trunk a-full a-1000
[code]...
I already change the wire without success, and already restart sw-edge02. With "u dld port disable" the link is working correctly.
I have two another switches working with SFP Cable:
Gi0/25 ETH-CH_1_SW-CORE02 connected trunk a-full a-1000 1000BaseCX SFP Cable
Gi0/27 ETH-CH_2_SW-CORE02 connected trunk a-full a-1000 1000BaseCX SFP Cable
Po1 Trunk_SW-CORE02 connected trunk a-full a-1000
Model number : WS-C3560G-24TS-S
System image file is "flash:c3560-ipbase-mz.122-50.SE1/c3560-ipbase-mz.122-50.SE1.bin"
View 8 Replies
View Related
Oct 23, 2012
know if it is supported connecting the SUP7L-E 10GE ports to a C3KX-NM-10G, using a SFP-H10GB-CU5M (or shorter).
View 3 Replies
View Related
Dec 14, 2011
i have question about router 2811, for now, all HWIC in 2811 is full,
Slot 0 : VIC2-2E/M
Slot 1 : VIC2-2E/M
Slot 2 : WIC-1T=
Slot 3 : HWIC-1FE
But we need add more 2 module VIC3-2E/M. can we use Network Module ? example : add one NM-HD-2V + two VIC3-2E/M ?
Can we do that? and whether it is the same as we use the VIC2-2E / M on HWIC slots
View 2 Replies
View Related
Apr 9, 2013
Is it possible to mix 1 and 10 Gigabit links on a 1/10Giga Network Module of the Cat3750X? I mean porte GE1/1/1 and GE1/1/2 used with SFP and port TE1/1/2 used with SFP+; that makes TE1/1/1 not available as GE1/1/3 and 1/1/4
View 7 Replies
View Related
Aug 7, 2012
how we can select a network module for 2811 router?gigabit or ethernet Hwic?
View 1 Replies
View Related
Apr 16, 2013
can i use any downlink port of the C4500-X switch as uplink without the need of the network module?i need to connect that switch to C6500E backbone without getting the network module, is that OK or i must get the network module?
View 1 Replies
View Related
Mar 25, 2013
I am considering running stacked 3750 L3 switches as the edge of the network, which will connect to the ISP. The ISP would hand off two lines with one to each switch and two lines to each client zone. Does running HSRP, running port channels, or running routing protocols seem like the best option for redundancy?
Lastly, will the 3750 provide all the QoS I should need for restricting each client zone's bandwidth both up and down? Could I get away with a lower model and still get these features?
View 3 Replies
View Related
May 21, 2012
we have three separated network segments going to one Cisco 3750 switch all is L2 .. from this switch is 100 mbit uplink.we need to apply some Qos mechanism not to saturate line by traffic from one network.. Configuration from various reason CANNOT be done on switch where 100Mbit line is terminated.. so all must be done on SW1,2,3..Correct me if iam wrond but as switches doesnt see traffic from other network iam affraid only think we can do is limit bandwidth on links going into SW1,2,3 to 33 Mbit.I found commad srr-queue bandwidth limit.But links going to SWs are 1Gbit so if i force bandwidth to 10% (minimum what command allows) its 100 Mbit..If I force speed on those links to 100Mbit and than apply srr-queue bandwidth limit to 30% doest it work.??. Will srr-queue bandwidth limit speed to 30Mbit?? Or srr-queue bandwidth limit is calculated from maxim speed of interface?
View 1 Replies
View Related
Feb 13, 2012
Currently we have an Ava ya IP Office switch running on the same network as our PC clients. I would like to seperate the two network into 2 V LAN's.
We have a mixture of Catalyst 3750 switches and some older 3500 models.Where do I start? Should I leave the PC's and servers on the default V LAN and just move the IP handsets?
View 6 Replies
View Related