Cisco Switching/Routing :: FSM726S - GBIC Compatibility
Oct 22, 2012
I've inherited a network. It looks to have been setup as 10/100 originally, using Netgear FSM726S switches with fibre connecting the switches. The fibre to copper conversion is mainly achieved with 10/100 media convertors rather than GBICs - not sure why - though there are some GBICs in use. Some of the "key" switches have been upgraded to Cisco Catalyst 2960G switches, but nothing else has been touched, so most of the network still runs at 100MB.
View 1 Replies
ADVERTISEMENT
Nov 7, 2011
I have an interesting problem. I have a 6509 that I'm trying to swap the GBIC on. The switch is already using a GLC-SX-MM GBIC and it is up/up and passing traffic, but we are getting some errors and suspect it may be faulty.
I want to replace the GBIC with one of the identical model - a GLC-SX-MM. It was brand new, never been opened. When the new GBIC is plugged in the link light on the switch goes completely off (not amber) and the port goes into a down/down (not connect) state. There are no messages in the logs at all. It's like it doesn't even see it. If you plug the old GBIC back in then the link comes back up. I tried a different port with the same results.Thinking that the new GBIC may be faulty (even though it was brand new) I tried a second GLX-SX-MM, also new. That one does the same thing.
At that point I thought there might be a problem with that switch, so I tried the GBICs on the other 6509 in that pair. The other 6509 is running the same hardware and software. The GBICs will not work there either. If you move the old, suspected faulty GBIC from 6509-2 to 6509-1 then that it works.
The solution would seem to be that I have two faulty GBICs, but I'm having trouble persuading myself that I have two new ones, straight out of the package, that are both bad. Are there any other things to check on the switch? Here's the pertinent information:
switch#show ver
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXI3, RELEASE SOFTWARE (fc2)
<snip>
cisco WS-C6509-E (R7000) processor (revision 1.3) with 458720K/65536K bytes of memory.
Processor board ID SMG1109N3BK
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
[code]...
View 15 Replies
View Related
Mar 11, 2013
is there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies
View Related
Nov 6, 2012
i have a cisco switch CISCO Catalyst 2960S 48 GigE, 4 x SFP LAN Base WS-C2960S-48TS-L for this i need a 1GB GBIC Connector. need right GBIC connector module and ather details
View 1 Replies
View Related
Apr 24, 2012
I have a Cisco WS-C6513 switch, with a couple of GBIC module cards in it. I am trying to display the part number (or model number) of the modules which are inserted into this module card. How to do that? I don't want to schedule down-time to pull the module(s) - just to read the label! :-)
This shows me info for the "module card": sh module 9 But this doesn't work: sh module 9/6
View 4 Replies
View Related
Dec 7, 2011
I am trying to get a C2960-8tc-L linked to a sge2000p via the Gbic ports using GLC-SX_MM gbics but having no luck.Are these compatible and should I need to configure anything?
View 1 Replies
View Related
Jun 17, 2012
I am having problems configuring a 4900. I have entered the following commands:
hw-module module 2 port-group 1 select gigabitethernet
hw-module module 2 port-group 2 select gigabitethernet
hw-module module 2 port-group 3 select gigabitethernet
hw-module module 2 port-group 4 select gigabitethernet
However no matter what I try, it never sees the GLC-SX gbics I have in the TwinGig converter.
PERSW001#sh interfaces status mod 2
Port Name Status Vlan Duplex Speed Type
Te2/1 inactive 1 full 10G No X2
Te2/2 inactive 1 full 10G No X2
Te2/3 inactive 1 full 10G No X2
[code]....
View 8 Replies
View Related
Nov 9, 2011
Is there any command to display the GBIC in the switch because I need to replace 3550 but I have no exact part number
the model is WS-C3550-24-SMI
and try
sh inventory
sh hardware
sh diag
sh module
View 1 Replies
View Related
Dec 14, 2011
Everything is in the title...When I plug a GBIC adapter on a port, my switch reload automatically..! Is it normal, because I did it during production and It disconnects some users.
View 0 Replies
View Related
Jul 18, 2012
The module WS-X4306, support fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?
View 1 Replies
View Related
Jun 25, 2012
I am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps. When connected together they do not enable. Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?
View 2 Replies
View Related
Jun 13, 2012
Are 887VAM-W-E-K9 and 800-IL-PM2 compatible? We have got both of them but it seems that router has a 30W power source and module has a 80W power source.
View 1 Replies
View Related
May 13, 2013
I have a WS-X6748-GE-TX with the WS-F6700-CFC daughter card. Is it possible to replace the WS-F6700-CFC daughter card with a WS-F6K-DFC4-AXL to make this compatible with the SUP-2T? Or, are there differences between the CFC and DFC base modules?
View 11 Replies
View Related
Sep 1, 2012
We have connected a single F5 box with dual links to 2 different Cisco Catalyst switches using 802.1Q trunks. F5 is configured with RSTP mode and on Cisco Switch RPVST+ is configured.STP root bridge is hardcoded on the Cisco side. Loop Guard is globally enabled.On F5 STP link type is Auto, STP Edge port is disabled since that port is connected to the cisco switch.When we are failing over the F5 primary link to the secondary link we see 'Loop Inconsistent' on the cisco switch and things dont work after the failover.We have tried configuring the F5 as STP passthrough but that doesn't fix out the issue.I have checked out the forums and found out following recommendations
1. Configuring MSTP bw F5 and Cisco for better compatibility (Not possible from Cisco side because of a major change in large production setup)
2. Configuring VSS in Cisco switches (not possible due to hardware limitation)
3. Connecting F5 using single links to each switch (redundancy compromised)
I am wondering that on which default vlan does the F5 STP instance0 sends the STP BPDUs ? the term used on Cisco side is native vlan and others use PVIDs; that F5 default vlan should match the native vlan on cisco trunk side.
View 2 Replies
View Related
May 31, 2012
we have to upgrade to nxos 5.2(4) but i cannot find same image for epld , i only see a downlable image with version 5.2(3). Do you see any problem if we upgrade kick and system image to 5.2(4) with epld 5.2(3)?
View 3 Replies
View Related
May 27, 2012
The below nexus 5020 nx-os version and type/revision of my GLC-T is compatible with each other? I noticed also the "Transceiver calibration is invalid" when i do show int e1/8 transceiver details , what does it mean?
View 8 Replies
View Related
Feb 7, 2012
We are upgrading two standalone 6509E chassis to a VSS system with new VS-S720-10G-3C cards. The 6509's have WS-X6748-GE-TX card with DFC3B daughter cards (see below). The compatablity matrix (see below) states that 67xx cards are supported but it goes on to state DFC3C or DFC3CXL cards are needed. So does this mean that the existing WS-X6748-GE-TX cards have to be upgraded or will they be supported?
Core #1Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ ----------- 1 48 CEF720 48 port 1000mb SFP WS-X6748-SFP SAL 2 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAD 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL 6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAL 7 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL 8 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL
[code]....
View 3 Replies
View Related
Jan 24, 2013
Just double-confirm that 2811 is compatible with HWIC-2FE based on your experience? Which IOS is compatible with HWIC-2FE? [URL]
View 3 Replies
View Related
Dec 18, 2011
Can a WS-C3750X-12S coexist in an existing stack made up of a WS-C3750G-12S and a WS-C3750G-24TS?
View 7 Replies
View Related
Feb 4, 2012
I have a Cisco 3825 router with a sfp module .(multi mode Cisco sfp ) connected to a Alcatel switch with fiberxon sfp. On a Cisco router the sfp card is been recognized and is seen when i used " show ip int brief " or show inventory commands. However the line protocol is down.
is their any compatibility issue with one side Cisco sfp and other side fiberxon sfp ? we have tested Cisco sfp -------Cisco sfp works fiberxon ----------------fiberxon works .
View 3 Replies
View Related
May 7, 2012
Currently i've a cisco ws-c4506-e edge swith loaded with cat4500e-ipbasek9-mz.122-53.SG4.bin image file. Can i use this image file on a ws-c4503-e as well?
View 1 Replies
View Related
Mar 25, 2012
I would like to confirm if Cisco 3750 and 3750v2 can work in a stack? My Cisco 3750 is working on 12.2(37)se while 3750v2 is working on 12.2(50r)se.
I tried to configure the above on a same stack but seem to have compatibility issue and fail to work.
View 3 Replies
View Related
Mar 13, 2011
We have existing stack of 3 units of WS-C3750-48TS-S ( 100 mbps ports with Gigabot uplinks). with IOS as follows, Can we add WS-C3750G-48PS-S in this same stack (this is 48 Gigabit ports)?
View 2 Replies
View Related
Mar 5, 2012
Is the C3KX-PWR-1100WAC= compatible with the WS-C3750X-24P-S?
View 1 Replies
View Related
Jan 31, 2012
I am looking to see if Nexus 5596UP & Nexus 2248TP GE compatible with SFP-10G-SR? The reason is because a consultant was hired on to "design" the network layout and has decided to purchase Cisco SFP+ Copper Twinax Cables which have a 10M limit. A small handful of the Data Center racks are 10-15M away... just out of reach of the Twinax. I would prefer NOT to move the LAN row so that it is more centered in the room. Can I use the SFP-10G-SR to connect the 2 switches (5596 & 2248) together? This SFP has a 26M reach on standard 10gig fiber, the small cost increase per connection is of no concern.
View 2 Replies
View Related
Jun 4, 2012
I am getting conflicting info about this, and need to get confirmations.Is the older 6513 (non E) model compatible with WS-X6407-10GE blade?The switch we're getting this for have WS-SUP720-3B, 6000W power supply, and WS-C6K-13SLT-FAN2.From what I read they are compatible if entered in slot 9-13, but I also heard that 10GE modules are not compatible with the non E chassis.
View 1 Replies
View Related
Jan 9, 2012
Does Cisco 1921-SEC/K9 support HWIC-4ESW ? I require 4 x 10/100 Ethernet ports
If yes how many ? are there any drawbacks if i use this module instead of a switch?
View 5 Replies
View Related
Mar 28, 2012
Will a WS-X6748-GE-TX work with a Sup 32 in a 6506/6509?
View 2 Replies
View Related
Jun 12, 2012
My old switch software version is c3750-ipbase-mz.122-35.SE5 and model number is WS-C3750-48TS-S and my new switch Software version is c3750-ipservicesk9-mz.122-50.SE5.bin and model number is WS-C3750V2 . I want a compatible (prefer same) version of IOS which works on both the switches as both the switch will be in a stack..
View 4 Replies
View Related
May 22, 2013
I have Cisco Access point AIR-CAP1602I-N-K9 ,My doubt is,is this AP support on WLC AIR-WLC2112-K9
View 1 Replies
View Related
Apr 14, 2013
I wanted to know that in nexus 7009, can i use mix of F2/M1/M2 series line cards ? will they work with each other ? Lets say i have F2 line card and M2 line card, will servers attached to them will communicate with each other ?
View 4 Replies
View Related
Sep 12, 2012
I have a Cisco 3560 connected via fiber to a Nortel 1612G. The connection is up/up, the V LAN's on the switch work as needed, but I can not ping the switch from the Nortel, and as a result I can not remote into the Cisco for management. I see in the configuration for the trunk that it is configured for a native v LAN, but I don't see it defined which v LAN's are allowed, could this be the issue? I will provide some of the config information for the Cisco side, I understand the issue may be on the Nortel end but if the Cisco part looks OK?
Port config for the trunk:
interface GigabitEthernet0/49
description port_6_1612G
switch port trunk encapsulation dot1q
switch port trunk native v LAN 120
switch port mode trunk
Native v LAN config:
interface Vlan120ip address 172.16.120.11 255.255.255.128
View 3 Replies
View Related
May 9, 2013
can I plug power supply from 4500 to 6500? more specifically we have power supply PWR-C45-1300ACV. And we need to place some power supply to 6500, which has only one active module. So 1300 should be enough for it. But we dont know if they are physically compatible, if it is possible to plug. I didnt find this power supply to be officially?
View 4 Replies
View Related