Cisco Switching/Routing :: Hot Add - N55 M16UP Module In NX5548up?
Dec 16, 2012Hot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?
View 2 RepliesHot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?
View 2 RepliesWas wondering if anyone has ever hot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?I looked at the H/W install guide and it does not mention anything.
View 3 Replies View Relatedgive me a link to where I can find the minimum code version for N55-M16UP expansion card for a Nexus 5k?
View 1 Replies View Relatedi have a cisco router (3900 series) and a add on module (4 x 1 Gig port module). For some reason i cant seem to port channel them and cant do routing (can set an ip address on those ports). I can do port channel and routing on on-board ports. Do i have to enable any commands to do this ?
View 3 Replies View RelatedMy C6506 USING ws-sup720-3B, i upgrade the IOS to the latest release of 12.2(33) SXJ1 IOS version. After upgrade and reload the machine got one module cannot be detect..WS-X6416-GE-MT, 16 port 1000mb MTRK ethernet module. The version of this are:
-HW 1.0
-FW 5.3 (1)1
-SW 8.5 (0.46) RFW
Question 1: Any tools available on cisco to check out the hardware/software compabiity feature?
Question 2: Any release note, compability matrix table etc resources.
Recently we ha a Nexus 7010 with a module frozen that was OIR (Online Remote and Insert) but do not work until reload the Nexus 7k.The command "show tech-support" has the following:
exception information --- exception instance 64 ----
Module Slot Number: 1
Device id : 147
Device Name: 0x93
Device Errorcode: 0x9329201
[code].....
Was is Excessive Interrupt Events? Can this "Minor Error" frozen the system?Is the port 42 on module 1 affected? o was 42 ports?
Can the encryption module (DES/ 3DES/AES/SSL VPN Encrytion/compression) for Cisco Router 3845 able to support the external connection from other high end router, for example cisco 7200? What is the maximum bandwidth, load and concurrent connection it can support?
View 1 Replies View Relatedwhy is not possible to put a WS-X4712-SFP+E - module into an R-E chassis?The module has the same connection to backplane as the WS-X4748-UPOE+E and this one works in a R-E chassis.I know the restriction of Cisco that the 4712 is only supported in 4503-E, 4506-E,4507+E and 4510+E, but why?Are there hardware-restrictions, is the backplane different?
View 2 Replies View RelatedI have a pair of 6509-E Switches running VS-720 Supervisors. We are planning to add Ace Module onto the 6509-E. Will IP Base Image suffice the requirement? Will Ace Module work with only IP Base Image?
View 1 Replies View RelatedDo you have any document that states whether WS-X4606-X2-E module is hot swappable or not?
View 2 Replies View Relatedconfirm the C3KX-NM-10G module is hot-swappable.i have checked the cisco's website and it says " Although network modules are hot-swappable, we recommend installing a network module before powering the switch"
What steps i need to follow to install the module?
Using the new SUP-2T, need to clarify one query. If we are using the new SUP-2T in VSS mode, will the new ASA service module and NAM-3 are supported? From Cisco site, ASA module FAQ:
Q. Will the ASA Services Module support the Cisco Catalyst Virtual Switching System (VSS) at FCS?
A. Yes, depending on which supervisor you use. The ASA Services Module supports VSS either as a single firewall or as a failover pair of firewalls, when used with the Supervisor 720-10G (VS-S720-10G-3C and VS-S720-10G-3CXL). Transparent and multi- context modes also work with the VSS in this configuration. However, though the SUP 720-3B (WS-SUP720-3B and WS-SUP720-3BXL) is supported by the ASA Services Module, it is not capable of supporting the VSS. No reference to Supervisor-2T.
switch 6506 E with supp 720 does it support 10 GIG module ?
View 3 Replies View RelatedI have a client whom has a 4900M switch as their SAN switch. They are getting ready to upgrade their SAN to use 10G.I had quoted them a price for an X2 module, but I am unclear based on pictures I have seen of the part number
X2-10GB-SR
whether or not the X2 module plugs into the X2 slot on the switch, AND then also has to have a transceiver put in it to receive the SC ends of the Fiber jumper, or whether the SC ends of the fiber jumper plug into the X2 module directly.
I have a switch Cisco WS-C6509-E WS-X6716-10G-3C module ( module for 10 GB) , i have the IOS s72033-ipservicesk9-mz.122-18.SXF9.bin. I want to know if this IOS can support this module or not ? or , if i must do a upgrade , is that the IOS : "s72033-ipservicesk9_wan-mz.122-33.SXH8" work fine ?
View 7 Replies View Relatedi have a cisco Netowtk Analysis module installed on a 6513 core switch which is NAM-1, the version on the NAM is 5.1 and we need to upgrade to the latest version which is 5.1(2)
View 1 Replies View Relatedwe are planning to implement a VSS solution with a 6500 series switches with sup 2T. We also need to include an ASA service module on the design, however the budget is not enough to buy two asa service modules. So i want to know if is possible run a VSS cluster, whit only one ASA service Module. and also i would like know what happens if the single ASA service module fails? can the switch cluster continue operating just as if there is not a firewall installed?
View 1 Replies View RelatedI have a brand new 3650x switch that I was configuring via console and left it on overnight; this was friday night ( I forgot to keep the air conditioner on). When I returned Sunday afternoon and checked the switch I realized that the SYS and STAT lights on the front were not on, however the Leds on the PS module were still on. I powered it down and turn it on again but still there are no lights on the front. The PS OK and AC OK leds on the PS module are on but I noticed the leds on the two fan modules are not green or even amber; they are off.When I first turned on the switch I remembered distinctly that there were loud noice and if all fans were in overdrive mode for a few seconds then the went to normal. I'm not gettgin this loud noise phenomenom.
View 9 Replies View RelatedCan Nexus 5596 support more than 1 N55-M160L3-V2 layer 3 module?
View 4 Replies View Relatedits a hardware problem or just not get power to module 1 for module WS-X6748-GE-TX? this is the capture from show module and sh log :
------------------ show module ------------------
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX xxx
5 2 Route Switch Processor 720 (Active) RSP720-3CXL-GE xxx
Mod MAC addresses Hw Fw Sw Status
[code].....
Suffered a big outage on the network, the fix was to reload the module 3 on the 6509 switch, we had these errors on the log %CONST_DIAG-SW1_SP-3-HM_PORT_TEST_FAIL: Switch 1 Module 3 TestUnusedPortLoopback Port(s)[24,46] failed. System operation continues.in the end, we reloaded the card and it was all ok. is there anything I can do to check the card / or any deeper logs? would that error cause the card to crash?
View 1 Replies View RelatedWe ordered the wrong part number for a Cisco 4506 non-E chassis, the part number is: WS-X4624-SFP-E and the device is showing "Unsupported module"; What would the part number be for the non-E? WS-X4448-GB-SFP,Catalyst 4500 48-Port 1000Base-X (SFPs Optional) ?
View 1 Replies View RelatedAny doc for installing the a PoE switch module for a 2951? I find alot about the 2951 PoE Power supply but nothing for the switch module.
View 5 Replies View RelatedWe just received a new C2911 G2 ISR and have been trying to configure the EtherSwitch SM-ES2-24-P module on it. Through the router console, I tried assigning an IP address to the router Gi1/1 interface which I assume is the link to the Etherswitch module but all I'm getting is "IP addresses may not be configured on L2 links" - as per the docs, I should be able to assign an IP address on that "logical" interface link. Any other way for me to configure the ports on that switch module?
View 5 Replies View RelatedWe have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".
View 4 Replies View RelatedI'm currently getting a Nexus hardware failure at present.
switch %MODULE-2-MOD_DIAG_FAIL: Module 8 reported failure due to DEVICE POST/DIAG FAILURE in device 48
I'm trying to set up a 2951 with a 24 port switch module. I want the ports to act similiarly to the ports on an 881 router - where I assign the VLANs on the router and I set the VLANs to the switchport interfaces.I would like to be able to create the VLANs on the router portion of the 2951 and then, enter the switch module and configure the Ports to the VLANs but, how do I logically connect router to the switch? Is it an internal logical interface - meaning how are the VLANs getting from the router to the switch?
View 24 Replies View RelatedI have a cisco 6509 (ws-c6509-e) IOS 12.2.(18)SXF6 with the following modules and submodules: [code] I would like to add another module, I have WS-6816-GBIC or WS-6516-GBIC which one will work with my 6509 ? The 6509 has four module slots empty: 4-7-8-9, Can I add the card in one of these slots ?
View 10 Replies View RelatedHow I can shutdown a module when I am running vsl.I can use the following command #hw-module module 2 shutdown.As I have modules in both switch 1 and switch 2 how can I ensure I only shut down module 2 in switch 1.
View 1 Replies View RelatedA product I could have used a number of times is a expanded version of the C3KX-NM-1G device module. To include 2 or maybe 4 more SFP ports. From the layout behind the faceplate there is plenty of space which additional circuit boards could be placed, (which is used in the 2 port 10GB version). I don't need the 12 port fiber switch that Cisco has, because I need a few RJ45 connection at that location, which I would then have to buy additional Fiber to coper Gbics for a few connections where the switch is at. The reason I need something like this is I have a few locations which I get a main feed from the City fiber, then it gets sent out to a number of local buildings on my fiber. Maybe another option is to take the 12port switch, and have an option for 6 rj45 and 6 sfp connections.
View 8 Replies View RelatedWe have a VSS environment with two Cisco 6509-Es. IOS image:s72033-ipservicesk9_wan-mz.122-33.SXI5 when I switch on or reload the Core switches(VSS), I find a Minor Error in the "Show module switch all" command.I also did a "show diagnostic result switch 1 module 5"Switch 1 Module 5: Supervisor Engine 720 10GE (Active) SerialNo : SAL1521E035
Overall Diagnostic Result for Switch 1 Module 5 : MINOR ERROR
Diagnostic level at card bootup: complete
Test results: (. = Pass, F = Fail, U = Untested)
45) TestVslLocalLoopback:
Port 1 2 3 4 5
-------------------
U U U . F
This issue temporarily relieves when reseating the X2 module, but reappears after reloading the switch.
I was trying to get a visio stencil for C3KX-NM-1G module but it doesn't seem to exist. It indeed does not exists or I just can't find it.
View 2 Replies View RelatedWe are looking to purchase some addidtional 48 port swithches for our network. Currently we have the following swtiches setup
2 of 3750 POE-24 (These two are stacked and have our servers plugged into them). Currently no SFP modules.
3 of 3560 POE-24 (These each have two 1000BASE-T SFP modules in them, with UTP connecting back to the 3750 switches above)
We are looking to get 2 of 48 port C2960S-48TS-L switches with two 1000BASE-T SFP modules in each that then will also connect back to the 3750 switches.
I had a few of question about this:
Will the cisco lite version (rather than the more expensive cisco base software) support the 1000BASE-T SFP modules?
The 1000BASE-T SFP modules, are they auto-config? Have you the link for commands we can use, if required?
We don't have budget for stack modules, apart from that would you recommend we change anything with the new setup?