Cisco Switches :: SG300 Optical Monitoring Snmp-mib?
Apr 10, 2012
I was positively surprised to find the optical transmit/receive values using the show fiber-ports optical-transceiver detailed command on a SG300-10.
Now I'm wondering if there is also a SNMP-MIB to query these values? I've already tried the CISCO-ENTITY-SENSOR-MIB used by the larger devices running Cisco IOS, but this didn't work.
View 3 Replies
ADVERTISEMENT
Feb 5, 2012
We have C7206VXR NPE-G2 platform with transceiver which support DOM.Could we monitor DOM tx/rx level statistic through snmp for 7206 platform?In CLI result of command "sh interf GigabitEthernet0/1 transceiver" give some information.We tried search for some MIB In "MIB locator" on cisco.com.
View 2 Replies
View Related
Jun 9, 2011
I have two SG300-20 Switches and buy two MGBLX1 Modules for the Switches.
I plugedin the Modules but the Modules didn`t work and in the WebConsole i can´t see the Modules.
Is there any configuration to enable the SFP Modules? or is it a problem from my Switches
View 3 Replies
View Related
Aug 7, 2011
Any snmpset commands to add, modify and delete vlan table entries on SG300-10 switches? I checked url... however this information is apparently only valid for catalysts. The latest firmware is installed and the provided MIB files are used.
View 8 Replies
View Related
Feb 3, 2013
how to configure SNMP on the Cisco SG300 switches? I have the SG300-10P. I am not fully familiar with the new command line interface on this device, it was easy on the IOS but finding it a nightmare on this one.
I put the following command in but it didnt work.
snmp-server view Interfaces interfaces included
snmp-server community ACB123 ro 10.x.x.x view default
I tried to follow the guidelines on the cisco website but thats all Web interface based, i can only access the switch remotely via CLI.
View 3 Replies
View Related
Sep 4, 2011
Any snmpset commands to modify port vlan membership on SG300-28 switches? I checked [URL] however this information is apparently only valid for catalysts.
The latest firmware is installed and the provided MIB files are used.
View 5 Replies
View Related
May 24, 2013
I've got an SG300-10 connected back to back (trunked) with a Cisco 3560X switch, across a fibre link and am seeing some big inconsistencies in terms of unicast data transferred across the ports between them.
During a night time window of 4am - 6am I run backups which involves a large copy of files, that almost saturates a GigE link - we can see from the 3560X end that the link is running at a bit over 800MBit/sec of throughput, sustained. The duration of this transfer is consistent with the size of the files being transferred (ie just over an hour, and is what I'd expect for a data transfer of about that amount). Back-of-the-envelope calculations indicate that the 3560X is measuring this data throughput correctly.
However on the SG300 end of the link, which is also being polled by the same application (Cacti), I'm observing spikey counts of only around 20MBit/sec during that window. These counters are very obviously incorrect - there's a huge amount more data moving across the port than that. The incorrect calculations are showing on both the trunk port out of the SG300 (uplink) as well as the interface where the NAS is connected in (which is an access port).
Cacti is polling the OID: .1.3.6.1.2.1.2.2.1.16.57 which translates to IF-MIB::ifOutOctets.57 = Counter32.I'm running version 1.3.0.62 but this problem is not new to this release - previous releases and 1.2 based releases also had this problem.
It looks like multicast traffic may be being counted correctly (that's only a suspicion though), however what I am certain of is that there is a very large discrepancy with the unicast traffic counts.Is this OID the correct one to be using for this switch?
View 2 Replies
View Related
Apr 3, 2012
We currently have a few 5505s installed at client sites which are connected via s2s ipsec VPN to our datacenter's 5510. We are using Nagios to monitor the local data center and remote client infrastructure (over the VPNs) which has been working well.
We would like to also monitor the remote 5505s using SNMP over the s2s tunnels but it doesn't seem to be working, the connection is timing out. We've configured the remote 5505s with the same snmp statement we used on the 5510 (snmp-server host inside <remote datacenter IP> poll community ***** version 2c) yet the Nagios SNMP check cannot connect to the remote 5505s. We've also tried the command using 'outside' without any luck, not sure how to get SNMP to route over the VPN.
View 15 Replies
View Related
Jan 27, 2013
I am trying to poll the 5 minute average CPU utilization of my Cisco Aironet 1252 (IOS version 12.4(25d)JA) using SNMP OID .1.3.6.1.4.1.9.2.1.58.0.However for some reason I am not getting any response back from the aironet. Note I am able to retrive the memory utilization without a problem.
View 1 Replies
View Related
Mar 26, 2012
I am trying to add ACS 1121 (ver 5.3) to monitoring and seems that MIB are missing. Need MIB for this device which I can use in monitoring tool.
View 1 Replies
View Related
Jun 15, 2011
how snmp monitoring works when we have WLC in the networking.Before the WLC 5508 instalation, we had the Nagios monitoring each Access Point in the networking. Today, the Nagios still monitoring the networking, but the Nagios cannot get the same information of the APs (CPU, status interface, memory, etc).Now, the WLC controls each AP, the IP address, netmask, community (of all AP) are the same before the WLC instalation. I have tried to configure the SNMP information in Management>>SNMP>>Communities, but these configuration are from WLC and not from each AP.
How can I configure the SNMP setting in my AP to still use the Nagios to monitoring the networking?
View 1 Replies
View Related
Aug 13, 2012
I have 5 installations of ACS appliances (ACS 1121 running ACS 5.3). Is there a way to monitor them via SNMP? The AD client keeps dying on one of them, and even with the newest patch it's not up. Also, i want to monitor them up/down, CPU, memory... basic network monitoring to make sure my devices are healthy.
Any one know if that can be configured? I figured i'd ask here before opening a TAC.
View 2 Replies
View Related
Oct 3, 2006
I am building a few 3750 stacks, I want to be able to poll/monitor each individual switch in the stack but as it only has 1 ip associated with the stack how can I do this. I am polling the uplink interfaces but as I only have uplinks on the top and bottom switch I am blind to a switch going down in the middle of the stack.
View 4 Replies
View Related
May 23, 2011
I'm a C# programmer and as part of my software I need to monitor some Cisco Catalyst 3560V2 24 switches using SNMP (By reading MIB/S data).Apparently this switch supports more than 50 different MIBs.My question is which MIB/MIBS contains general health data (parameters) that may determine if the switch is OK, Degraded or Malfunctioned.
View 0 Replies
View Related
Mar 27, 2008
I am trying to monitor my ASA 5505. This asa is connect via a ip-sec tunnel to our network. I have no problems with snmp monitoring devices behind the ASA, but when trying to monitor the asa itself I do not get a SNMP response.
View 2 Replies
View Related
Oct 21, 2012
I have two 6509E's configured with VSS. In this configuration, is it possible to monitor the CPU and memory of each switch independently using SNMP?
View 1 Replies
View Related
Nov 5, 2011
I'm running 12.2(33)SXJ1 on a 6500 with several IPv6 BGP peers. Is there any way to monitor the BGP status of IPv6 peers? I've been through the BGP4 mib and cant seem find a way to check the status of IPv6 peers.
View 4 Replies
View Related
Jun 19, 2012
Is temperature monitoring via snmp supported on Cisco 2801 routers? when i perform a snmpwalk i donot get the associated value for the oids.
View 2 Replies
View Related
Oct 7, 2011
I whish to connect the two switches shown below.The distance between them is 50m (~54 yards), one floor apart, and I would like to link them with the cheapest optical solution possible.I have been given a solution with 19inch patch panel, splitter, pigtail cords, patch cords, SC connectors, i.e., the lot.Not being an expert in networking, I feel that is an overkill solution.
Servers______________________________________ Devices/Other Switches
| ___________________________________________________|
| ___________________________________________________|
V ___________________________________________________V
(SLM2048-EU-SFP port) <----------------------> (GBIC port-CISCO 2950 Series)
^
|
|
SAN
View 12 Replies
View Related
May 1, 2012
I am using ASA 5510 Firewall and i have established VPN tunnels too , now i want to Monitor the bandwidth utilization , i have installed PRTG Monitor application and want to add the firewall , how to enable the SNMP in ASA .
View 1 Replies
View Related
Aug 29, 2011
These are our first switches and seems like GUI is lot different than the online. Out intervlan routing is o not working. I am absolutely sure that I setup the switch in L3 mode since it allows me to create mutiple interfaces. I am hoping that this GUI issue is related to interVLAN routing.
Below is the blog I started for InterVlan issue [URL]
This is the link for online simulator and what I see in its IP tab. I know this switch is not SG300. [URL]
This is what I see on our switch.
Our switch version
switchd64684#show version
SW version 1.1.0.73 ( date 19-Jun-2011 time 18:10:49 )
Boot version 1.0.0.4 ( date 08-Apr-2010 time 16:37:57 )
HW version V01
View 1 Replies
View Related
May 26, 2011
1) I have a Cisco SG300-28P. I plan to add a SG300-52. Would it be possible to manage the new switch through the SG300-28P web browser ?
2) There are 2 fans in the POE model SG300-28P. How many fans are they in the non POE switch SG300-52 ?
View 2 Replies
View Related
Apr 4, 2013
I'm currently implementing Microsoft System Center 2012 Operations Manager, the curent stage of the project is to add the network devices to SCOM via SNMP in order to monitor them, I am able to add them all and monitor; however, my ASA 5510, although SCOM discovers the ASA via SNMP and adds it to the network monitoring list, it loses SNMP connectivy every 30 minutes, and 15 later it reconnect with SCOM, then after another 15 minutes it loses the connection again, and so on and so for.
View 1 Replies
View Related
Feb 14, 2013
We have a scenario where we want to connect 14 access layer 2950 switches to Core switch 3750 via optical fiber in a LAN.What model of 3750 Switch should we use to tackle this situation.I have learnt that WS-C3750X-24P should support it.Isnt it?
Can we use optical fiber SFP module to connect 2950 switches to core switch?Does Cisco 2950 Switch support optical fiber sfp module?
View 2 Replies
View Related
Oct 4, 2012
We have an SG300 managed switch located in a small business of less than 10 PCs. There has been an ongoing issue with Internet speed. Is there any way that I can monitor the router for traffic so that I can see what might be causing the problem? I would like to focus on the WAN port and Internet activity particularly.
View 1 Replies
View Related
Feb 8, 2012
Can I connect a single Cat5e cable between two SG300-28 and link them? If so what must I configure?
View 1 Replies
View Related
Jul 25, 2012
I have SG300-28P that I am using as layer-3 switch. Recently I ran in to SG300-52 switch and even though loading same firmware doesn't give me option to do layer-3 switching. For SG-300 I see options in GUI to create vlan interfaces under IP information section, while SG300-52 has IP information option only under the management section.let me know if these are 2 different hardware types and L3 is not possible on SG300-52. If its possible to enable L3 switching on SG300-52?
View 2 Replies
View Related
Sep 7, 2011
How I can actively monitor the interfaces and overall status of 2 x ASA 5500s in an Active/Standby configuration?
I can setup monitoring of the interfaces on the Active member but I'm not sure how to manage the Standby member?
View 1 Replies
View Related
May 22, 2012
I'm setting up an SNMP poller to retrieve the ARP table (ipNetToMediaPhysAddress) from my SF300 switches. I can retrieve the table from SF300-24P and SF300-48P switches running Firmware Version 1.0.0.27, but get garbage for the MAC address when retrieving that same table on the same model switches running Firmware Version 1.1.1.8. Is there an outstanding defect on this code level? How can I retrieve the table showing the IP address to MAC address mappings?
View 1 Replies
View Related
Nov 21, 2011
I'm replacing 2 3COM 4500 Swithes with the SG300-52 Cisco switch. We have 3 VLANs, 10, 20, 100. The switch is set for Layer 3 and I have setup DHCP relay. what settings i should set on the Cisco for the following setups:
3COM Setup
#
interface GigabitEthernet1/0/1
[Code].....
View 2 Replies
View Related
Jan 1, 2013
We have several of the SG300 Serices switches. We use them to route VLAN traffic to Remote Offices, Internet Connections, and WiFi Access Points.In one remote office we have a SG300-10 setup to route the HQ Network and the remote Office Subnet. The SG300 is Connected to HQ via Fiber and has multiple Tagged VLANs on it. If I do speed tests over the Fiber Link on the Incoming Tagged Netwotk I get Decent performance, 80Mbs. If I switch to a networtk that is not priginating from HQ, and have the SG300-10 route packet, I get dismal performance. 15-20Mbs.
I Fireded up a New SG300-28P FW v1.2.7.76. Added a the HQ VLAN 101 and new VLAN 1025 . Mapped some Tagged and untagged ports for each. Switch was connected to HQ Network as untagged VLAN 101. I put a laptop on an Untagged VLAN 101 port. Ran some tests, cam back with 750-850Mbs. Great. Put the same laptop on a Tagged 101 Port, Configured the NIC for Tagged VLAN 101, Same test, same Speeds, 750-850Mbs.I then Configured laptop for Tagged VLAN 1025. Connected to tagged VLAN 1025 port. Ran speed tests, resuts were 15-20Mbs!
I then Configured laptop for Untagged VLAN 1025. Connected to unagged VLAN 1025 port. Ran speed tests, resuts were 15-20Mbs!It was only the Laptop and the Connection to the HQ net on the SG300-28P. Why is the performance of this unit soooooo poor when it needs to route?Other Switches have FW v1.0.0.27 or FW v1.1.2.0. They have Similar speed issues. All Configured for Layer 3.
View 10 Replies
View Related
Dec 18, 2011
does the SG300 switches can be used with Microsoft NLB in Multicast mode?I know on traditional Catalyst switches you can statically "map" IP's to mac's and then to multiple ports but this doesn't seem to work correctly on the SG switches - it gives an error about the mac not being not Unicast?
View 2 Replies
View Related
Aug 20, 2012
I'm going to have several SG300-28P switches to setup. I'll need to create multiple vlans for data, voice, and wireless traffic. I have the following questions in setting up this configuration:
VLAN 1 Management
VLAN 100 Data
VLAN 200 Wireless
VLAN 300 Voice
1) For managing the switches via IP, will LAN1 be the default management network? Should I create a seperate VLAN for managing the switches?
2) For uplinking the switches together, I plan to trunk a port to connect the switches together. What's the configuration on the trunk port to forward all vlans from one switch to another?
3) On some ports, I want to configure a trunk for two vlans (Data and Voice) where the phone has a pass through for PC. The phone supports tagging for the PC and the VoIP traffic. For example on port 10, would VLAN 100 and 300 be set to tagged?
View 3 Replies
View Related