Cisco Switching/Routing :: 2950 Switch Booting Through Monitor Mode
Jul 17, 2012I have 2950 switch booting through MOnitor Mode.Analyzed there is no Cisco IOS image in flash.
View 1 RepliesI have 2950 switch booting through MOnitor Mode.Analyzed there is no Cisco IOS image in flash.
View 1 RepliesI have a Catalyst 4506e that works fine but if reload, it boots in rommon mode. I can start it with a boot command, but by default, i must type a command. My config-register is 0x2102.
View 5 Replies View Relatedi facing problem with my switch cisco 3560G, when it power on only System light is green and noting happen. i check with serial cable ( Console) but noting happen no booting.
View 2 Replies View RelatedYesterday I've faced a Problem that is not letting me boot with the new IOS.
Actually I'm planning upgrade IOS which supports SSH. As part of plan I've downloaded the new IOS image and uploaded via TFTP server to the switch.
After uploading to the switch. I've verified image and MD5 hash also. Everthing is fine. Then after I set the boot variable for the newly uploaded Image.
When I'm rebooting the Device it is not taking the new IOS. It's booting with the OLD image. Even It's not showing any error message while rebooting (ACTIVITY FILE ATTACHED FOR YOUR REFERENCE) I can't take risk by deleting the old IOS.
i am facing time daely issues on cisco 2960 s series switch while booting .It is taking time for electing masrer and sleeve for stacking.can i disable the election process for stcking while booting.
View 4 Replies View RelatedI am having 2950 Cisco switch. After completing the boot process LAN Ports are working for few minutes afterwards Ports are going into Orange Signal Mode.
View 1 Replies View RelatedOne of my customer had a problem with A/C and the room temperature reached almost 50 C. We came to the site and saved the configuration, took a backup and shutdown the switch.
After the A/C problem is resolved, we tried to power-on the switch .. and we found that it is going to the rommon.
I put "boot" command to boot from the bootdisk, but I am getting the following error:
Code...
I tried to search it, But it is resulting in that most probably it is a hardware failure on the SUP.
One of my wi-fi site having 2nos cisco 2950 switchs. in that network some D-link unmanageble swithes also there and access points also connected to cisco switchs and D-link switchs.after one or two days i am not able to connect the wi-fi, then i need to restart the access point then only wi-fi is working fine.I upgraded the latest ios also.I connected some access points to the cisco switch ports, those ports are showing crc error messages like below. [code]
View 18 Replies View RelatedAfter setting up the domain name I try to use the crypto key and it is no where to be located. Below is some of the information I copied from TeraTerm
Switch-1(config)#ip domain-name justin.lab.comSwitch-1(config)#crySwitch-1(config)#cry?% Unrecognized commandSwitch-1(config)#crypto key ?% Unrecognized commandSwitch-1(config)#crypto key ^% Invalid input detected at '^' marker.
Switch-1(config)#?Configure commands: aaa
I have cisco 2950 catalyst switch, verson IOS (tm) C2950 Software (C2950-I6Q4L2-M), Version 12.1(20)EA1a, RELEASE SOFTWARE (fc1)
So. for one of my port (FE 0/3) i need to put the bandwith limit 512 kbps, how to configure the above same.
Note:- I configured the below but no effect
1. interface FastEthernet0/3description * CONT TO B-CENTER *switchport access vlan 10switchport mode accessbandwidth 1024speed 10
2. and there is no srr bandwidth limit option for 2950, but the same is working for 2960.
Do they have a default IP assigned to them?
I'm trying to access the CMS administration page from my browser. I've already tried 192.168.0.1 and that brings up my gateway (cable modem from Time Warner).
I upgraded a Catalyst 2950 switch and there wasn't enough room so I deleted the flash. The upgraded went well using tftp. It booted up fine. The I0S version includes crypto. But, I can't access switch via web browser or CNA. Port scan shows port 80 0pen. What am I missing?
Here is the flash.
Directory of flash:/
2 -rwx 112 Mar 01 1993 01:00:48 +00:00 info 3 -rwx 3722814 Mar 01 1993 01:02:58 +00:00 c2950-i6k2l2q4-mz.121-22.EA14.bin 4 drwx 4416 Mar 01 1993 01:03:45 +00:00 html 331 -rwx 112 Mar 01 1993 01:04:19 +00:00 info.ver 332 -rwx [code]....
I am planning to change the management IP (VLAN 5) to one of my Cisco 2950 switch, Here I am creating a new VLAN101 and assign new IP
When I am doing this VLAN 2 is going admin down.
My requirement is that I want to set same console password in 12 switch instantly...
All the 12 switch are connected to a cisco 6500 L3 switch..
So how can i do that.. i have cisco acs 4.1...
can i do that by cisco acs 4.1 if not tell me an software or command ...
I have a cisco 2950 switch, connected with 4Mbps of internet and number of users will access the internet. There is no restraction on bandwidth limit for users, if any body use high download the remaining users are facing the slow browsing problems.
So, if i can put a bandwidth limitation for every users the problem will be solved. how to restract the bandwidth on user bases.
I am trying to configure 802.1x RADIUS Authentication on cisco 2950-24TT-L Switch. I am using following set of command as given below
Switch# configure t
Switch(config)# aaa new-model
Switch(config)# aaa authentication dotx default group redius
Switch(config)# dot1x system-auth-control
Switch(config)# inter fasteth 0/1
Switch(config)#dot1x port-control atuo
I am facing problem dot1x command is not working on interface.
I would like to know if ip helper-address feature is working on a layer 2 switch (2950,2960) or you should use a Layer 3 switch to do that?
View 7 Replies View RelatedWith out using any server, will DHCP be configured in cisco 2950/2960 switch?I man cisco it self should work as a dhcp server also.
View 10 Replies View RelatedI have two 3560G 24 port switches. Each of them connects to some 3560G or 2950 switches. Trunks between 3560G are set as 1000/full. Trunks between 3560G and 2950 are set as 100/full. show int status also shows the interface negotiation is 100/full for trunks between 3560G and 2950. The issue is I keep getting outdiscard errors in trunks between 3560G and 2950. At 2950 switches, I see Recv-errors too. I checked all the trunks traffic. They are totally not high. Only serveal mbps. Most time even lower than 1mbps.
I googled this kind of issue online. I see it could be possibly caused by high volume traffic higher than the capacity. But it appears the traffic there is not high enough to cause this kind of issue. Is there any possiblity that could cause this problem?
The below is 3560G trunk configuration for 2950 switch
interface GigabitEthernet0/10 switchport trunk encapsulation dot1q switchport trunk allowed vlan 1-122,124-4094 switchport mode trunk speed 100 duplex full srr-queue bandwidth share 10 10 60 20 queue-set 2 priority-queue out mls qos trust cos auto qos voip trust
the trunk configuration at 2950 switch: interface FastEthernet0/24 switchport trunk allowed vlan 1-122,124-4094 speed 100 duplex full
As always, the Cisco LMS is keep sending the follwoing high discard error from the Cisco switches WS-C2950T-24:
EVENT ID = 0004SX3
ALERT ID = 00019LF
TIME = Tue 14-Feb-2012 08:56:35 GMT
[Code].....
In my lab, there are some machines that are connected using Cisco 2950 switches. Those machines belong to a VLAN.Now I need to modify the VLAN settings of the machines and as such I also need to modify the VLAN settings on the ports on the Cisco switches.
In order to do this, first I need to login to those switches, but due to a lack of knowledge transfer, I don't have the password. Is the some generic password?Second I will need to modify the VLAN settings on each individual port. How can I do this?
how to recover password and retrive configuration on Cisco switch 2950 and 3560.I know the way to press and hold the mode button and then plug in the power cord can reset the switch to factory default but it will reset everything to nothing. As such, it is not what I want and I want to keep the configuration file and able to use the configuration on the switch.
View 2 Replies View Relatedwe are using 3750 and 2950 switches both of them do not support vlan up to 4000 .we need vlan about 3000 .Whic cisco series switch do support vlan up to 4000.
2950
S-SW1.3(config-vlan)#exi
Proposed configuration has too many VLANs for this platform. Reduce the number of VLANs proposed.
S-SW1.3(config)#end
3750
SW1(config-vlan)#exi
proposed configuration exceeds the limit of 1005 VLANs that can be supported on this platform. Reduce the number of VLANs proposed to be within this limit.
Can a layer 2 cisco 2950 switch be used as a dhcp server with it's own address pool.
View 3 Replies View Relatedcan i configure virtual circuits on cisco layer 2 switch catalyst 2950 ?
View 1 Replies View RelatedI have a lab setup to take my CCNA and CCNP and I'm having issues trying to get WAN connectivity back to a switch at the end of my network. My lab environment consists of 1 - 2950 switch, 1 - 2620 and 1 - 2621XM. I have 1 Ethernet connection from each router to the switch and 1 serial connection from the 2620 to the 2621XM. I have the serial interfaces in a shutdown state right now so there is no loop since I do not have Spanning tree setup on the ports on the switch yet.
Right now using the fast ethernet ports on the routers and I have no issues its when I shut down those Ethernet ports and try using the serial interfaces when I start having issues. So my network layout is Ethernet from switch port f0/4 to port f0/0 on 2620 and serial from s0/1 on the 2620 to s0/2 on the 2621XM. My 2621XM f0/1 is whats connected to the WAN and I have no issues getting to the WAN from my 2621Xm or my 2620 but when I try pinging any website or even my WAN default gateway from my switch I get nothing!
Ive also noticed that when I do a IP NAT translation (after accessing the WAN from my 2620) on my 2621XM the source IP is of my serial connection not the ip of my 2620 router? I have my default gateway on the 2620 as the the IP of my serial interface on the 2621XM and vice versa because my LAN network is 172.16.1.0 and my WAN is 172.16.9.0. I have a /31 setup between my serial connections 172.16.11.0 (s0/1) is on the 2620 and 172.16.11.1(s0/2) is on the 2621XM. I used the SDM (ver 2.5) to setup NAT to have f0/1 with Nat outside and s0/2 as Nat inside. Encapsulation is HDLC between the serial links. Ive attached the running configs of the switch and routers.
Need your expert input in sorting out the below problem.I have a cisco 6513 switch which is going into SP mode after a reboot whci i have done during BCP activity in my organization.Below are the log for your reference.
Code...
We have two 6500 core switches and one(primary) of them is running in VTP transparesnt mode and the other (secondary) one is running in VTP client mode. I would like to change the VTP mode of the second switch to transparent mode. Would it cause any issue. I guess i have to create VLANs onto the switch.
View 7 Replies View RelatedI have found that the Catalyst 2955 series switches do not use an external MODE button for getting a switch into the switch: prompt, but they use a break sequence like routers do to get into Rommon state URL
So I was wondering if there is a similar mecanism that applies to other kind of Catalyst switches, like 2960, 3560 or 3750.
The following discussion is based on cisco cat 6500 switches with two power supplies: p1 and p2. . Both power supplies are running in combined mode .Each power supplies is rated with 500 watts max( I just picked 500 watts for simplicity)Combined mode In combined mode, each power supply provides approximately 83% of its capacity to the chassis. This allows for greater utilization of the power supplies and potentially increased PoE densities
1) Let say our specific 6500 switch's configuration requires 1000 watts. We have two power supplies p1 and p2 ,each with rated power of 500 watts. Both power supplies must operate in combined mode. Will power supplies be able to meet the total load power requirement of 1000 watts?
Here is my understanding :The maximum power delivered by each power supplies is 83 percent of its rated power, assuming power supplies are running in combined mode.
So Maximum power delivered by power supplies
= 83% of p1+ 83% of p2
= 83% of 500 + 83% of 500
= 415 +415
=830 watts
Thus the required load of 1000 watts can not be met by our power supplies in combined mode.
2 )Suppose our switch's switch configuration needs 500 watts. Again our power supplies each rated with 500 watts, are configured for combined mode. How much power is being delivered by each power supply? Is it 83 percent of the total load i.e 500 watts?
Two Cisco 3750X can be stacked together to ensure redundancy.Is the attached topology feasible for access layer redundancy?
View 5 Replies View RelatedI have a 3550 switch that was replaced at a remote site with no IOS. This is a switch not a router so tftpdnld does not work.
[Code]...
The problem is the switches interface never comes up so try to connect to the tftp server. I read on google it can't be done on a switch to copy from tftp to flash in rommon mode on a switch and to use XMODEM. My problem is I do not have access to it, I ssh into a 3640 which is an access server for all devices and that is how I have console to it, how to use XMODEM over ssh.
But I'm fairly certain that there has to be a way to just copy it from tftp? I have a 3550 local and when I put it in rommon mode it stops the port check at port, port 1 goes from green when you plug it in to off then port 2 changes to amber and the rest green. So just by the look of this I would believe tftp would work; you just need to use port 1.
I'm trying to get an IP_ADDR set on the management port in SWITCH: mode but for some reason the port seems disabled. PC shows connection unplugged. MGMT_INIT is not a valid command (not listed under '?' ). Bootloader version is 12.2(53R)SE2 FC1.
View 4 Replies View Related