Cisco Switching/Routing :: 6513 - Mod 9 Recycling Power - 10 Gig 6704 Card

Feb 26, 2012

I have 2 6513's between floors that have a port channel between them using 2 10 gig interfaces on 6704 cardsThis weekend I lost the port channel for about 4 mins and then it came back up. Unfort at the time I had logging turned off so was unable to get any info as to why. But I turned on debugging that eve and this morn it happened again.
 
Looks like Mod 9 is being power recycled, 6704 is about a year old and had been running for a month or so without issue.The only thing I have upgraded in the last few weeks was I put in a pair of 6000w supplies..But I am not having any other issuesother than mod 9. In hind sight a better design would be to spread this port channel across 10 gig cards. I'll work on that next.
 
2w2d: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled 'Off (Module Reset due to exception or user request)'2w2d: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set Off (Module Reset due to exception or user request)*Mar 1 00:00:02.331: DaughterBoard (Centralized Forwarding Card)

[Code].....

View 3 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Module Power Down On 6513 Switch?

Apr 28, 2012

We have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".

View 4 Replies View Related

Cisco Switching/Routing :: 6513 Power Showing Wrong Wattage?

Oct 26, 2011

I just upgraded my power supply's from 2500Watts to 4000watts, however the show power still shows 2500watts.how do i make the 6513 recongize the change? I do have 250volts at 30 amps connected to each power supply.
 
system power redundancy mode = redundant
system power total =     2331.00 Watts (55.50 Amps @ 42V)
system power used =      1741.74 Watts (41.47 Amps @ 42V)
system power available =  589.26 Watts (14.03 Amps @ 42V)

[code]...

View 1 Replies View Related

Cisco Switching/Routing :: 6513 Switch Giving Module 11 In Power Down State

Apr 7, 2012

After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command:
Power enable Module 11 was issued and returned the following:  %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.

View 6 Replies View Related

Cisco Switching/Routing :: 8700W Enhanced AC Power Supply With 6513 Chassis

Mar 6, 2013

I understand that 8700W enhanced AC power supply is Compatible with 6-, 9-, and 13- slot chassis
 
Based on 8700W Enhanced PS datasheet, it can be installed into existing Cisco Catalyst 6500 Series Switch chassis: both E- and non-E series Cisco Catalyst 6500 Series Switch chassis.

Can we use 8700W enhanced AC power supply with 6513 externally / internally (within one of the chassis slots like 6513-E ?

View 1 Replies View Related

Cisco Switching/Routing :: 10G Card On Cat 6513 - Fan Tray No Support

May 8, 2013

I have just buy a 10G card for Cat 6513, these are information: PDCMSFC-1>sh module

Mod Ports Card Type                              Model              Serial No.
--- ----- -------------------------------------- ------------------ -----------
  2   16  SFM-capable 16 port 1000mb GBIC        WS-X6516A-GBIC     SAL08373Z37
  7    2  Supervisor Engine 720 (Active)         WS-SUP720-BASE     SAD08330322
 
Mod Sub-Module                  Model              Serial        Hw     Status
--- --------------------------- ------------------ ------------ ------- -------
  7 Policy Feature Card 3       WS-F6K-PFC3A       SAD083207AL   2.4    Ok
  7 MSFC3 Daughterboard         WS-SUP720          SAD0832037Y   2.3    Ok
 
About card: WS-X6716-10G-3C

When I install this card on Cat 6513, has a message: " fan tray no support"

View 5 Replies View Related

Cisco Switching/Routing :: Added X6704 Card To 6513 Switch / Not Working Correctly

Mar 7, 2012

I just added a X6704 card to our 6513 switch, and it is not working correctly. We are running 12.2(33)SXI5. [code]

View 5 Replies View Related

Cisco WAN :: Different Voltage In Line Card Ws-6704?

Apr 24, 2011

I see differrent voltage in line card ws-6704. Iam afraid of something went wrong with my 6500 switch. two 6500 switch is redundant.

View 3 Replies View Related

Cisco Switching/Routing :: 10 Gig Distance Limitation Between 6704's

Jan 26, 2012

Looking to link up to 6513 chassis via 6704 10 gig cards.
 
I have a 6513 on the 8th floor and one on the 3rd floor in same building. Distance would be approx 150' max. New 10 gig cabling was installed between these floors.
 
I would like to use 2 10 gig ints on each 6704 to form a port channel (LACP) between the 2 environments.
 
So far I have been unable to get the links up between 6704's.

View 2 Replies View Related

Cisco Switching/Routing :: 6513-E / 6513 And WS-X6748-GE-TX Compatibility

Oct 29, 2012

we have a chassis 6513-E and a module WS-X6748-GE-TX, I'd like to know if could I put this module in any slot, since the documentation from Cisco says that any slot from a chassis 6500-E Series can support this module. And then in the documentation of WS-X6748-GE-TX says that this module is not compatible in the slots 1-8 of the 6513 chassis, only from 9th to 13th slots, in those slots from the 6513-E we already have 4x WS-X6748-GE-TX, and we'd like to know if could we put the module in the rest of the slots. The 6513, and 6513-E is kind of confusing.

View 4 Replies View Related

Cisco Switching/Routing :: 3750 - Power Stack Has Unbalanced Power Supplies

Jun 9, 2013

I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
 
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)

211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:

[Code]....

View 1 Replies View Related

Cisco Switching/Routing :: Stack-power 3750x / FRU Power Supply Is Not Responding

Sep 4, 2012

After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
 
Config  : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
 
Only: LMS prime /inventory/cisco-view/configure/power supply status  result :  some power supply's are marked as disabled.with the command  > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
 
Looks like SNMP en IOS difference from opinion.
 
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
 
Software
15.0(2)SE
C3750E-UNIVERSALK9-M

View 5 Replies View Related

Cisco Switching/Routing :: WS-C3560-48PS-S Show Power Inline But No Power Available

Apr 14, 2013

We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
 
Here is some output.
 
Hostname#show power inlineAvailable:0.0(w)  Used:0.0(w)  Remaining:0.0(w)
Interface Admin  Oper       Power   Device              Class Max                            (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1     auto   off        0.0     n/a                 n/a   15.4Fa0/2     auto   off        0.0     n/a                 n/a   15.4Fa0/3     auto   off        0.0     n/a                 n/a   15.4Fa0/4     auto   off        0.0     n/a                 n/a   15.4Fa0/5     auto   off        0.0     n/a                 n/a   15.4Fa0/6     auto   off        0.0     n/a                 n/a   15.4Fa0/7     auto   off        0.0     n/a                 n/a   15.4Fa0/8     auto   off        0.0     n/a                 n/a   15.4Fa0/9     auto   off        0.0     n/a                 n/a   15.4Fa0/10    auto   off        0.0     n/a                 n/a   15.4(code)

View 1 Replies View Related

Cisco Switching/Routing :: 6500 - Power-Redundancy Mode Combined And Power Fail

Feb 28, 2011

I have a 6500 chassis with 2 power supplies. At the moment  I am using the default configuration:
 
power-redudancy mode redundant
 
The problem is that an inserted module is in "power deny" state due too insufficient power.
 
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
 
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
 
The 6500 config guide states:
 
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
 
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?

View 3 Replies View Related

Cisco Switching/Routing :: 3750X Stand Alone Secondary Power Supply Act As Pool Of Power

Apr 4, 2012

In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)?  I understand there is no stack involved here but I'm curious if this functionality is possible.

View 1 Replies View Related

Cisco Switching/Routing :: 6513 - SSO Functionality

Jan 31, 2012

Well I have been back and forth on this a while now...I have a 6513E chassis that is getting prepped for prod. I am currently testing sso functionality and I can only get it to work using the following images on both Sup Cards.  

s72033-adventerprise_wan-mz.122-33.SXI5.bin
 
If I try any other image, smaller or bigger in size...it forces my Sup card in mod 8 to recycle " proxy request from peer ". I have tried K9 images and non K9 images. Here is an output from sh redundancy.

Redundant System Information :  Available system up time = 4 minutes Switch overs system experienced = 0  Standby failures = 0 Last switchover reason = none [code]...

View 2 Replies View Related

Cisco Switching/Routing :: 6513 CatOS Config To IOS

Jul 31, 2012

I have a new 6513 with 2 sup32's with IOS. This chassis will replace a working 6513 with 2 sup2's with CatOS.I need to pull the running config from the CatOS chassis and make it work on the IOS chassis. i can do this manually but was wondering if there are any trade secrets on doing this.

View 3 Replies View Related

Cisco Switching/Routing :: Replacing A Backup Sup 720 On 6513

Nov 21, 2011

I am replacing a faulty sup720 on a 6513. It s the backup/hot not the active sup. It has the same IOS on it. Is it correct that all I need to do is remove the faulty and replace it with  the new sup and do a wr mem? Fromwat I have read their should be no down time all connectivity should remain stable?

View 6 Replies View Related

Cisco Switching/Routing :: Unable To Console / Ssh To 6513

Aug 9, 2012

I have a 6513 with redundant sup 720-3B's that I cannot get onto.  In short, one of the power supplies failed, it still passes traffic but I can't console or ssh to the box.  Other than the two sup 720's, I have a 4 port 10gig card, a 16 port GBIC Card and an IDS module.  I have tried removing the 10Gig, IDS and one of the sup's but still don't get anything on the console.  I have rebooted the entire chassis and don't get anything on my console while booting.  I have tried changing the speed of my terminal to every setting available incase someone has changed it at some stage but to no avail. I have tried swapping sup's, using only one at a time in the chassis but not getting anything. Is there anything else I can try to get onto this chassis?  The power supply is a 3000w with a 32amp input.  The failed power supply had tripped a switch, when i brought it back up, the power supply came out but the output failed LED is on. My #questions are, is there anything else I can do to try get onto the console, and is the power supply goosed when the RED LED is lit?  I have reseated the power supply also but the same result.

View 2 Replies View Related

Cisco Switching/Routing :: 6513 / 6509 E - EOL Notices

Apr 18, 2013

Are there any EOL notices out for the Catalyst 6513, 6509 etc E chassis? I cant find anything on the internet for the E variant, so assume this hasn't had a notice published yet.

View 2 Replies View Related

Cisco Switching/Routing :: VSS Configuration On 6513 Switches

Mar 10, 2013

My question is regarding VSS configuration on Cisco  6513 switches. My understanding is that the hardware and software  configuration on the devices must be exactly the same for the VSS to  function correctly. Do the Bootstrap versions also have to be identical?
 
The production switch is running Bootstrap Version 12.2(17r)SX5, while the new switch is running Bootstrap Version 12.2(17r)SX7.

View 3 Replies View Related

Cisco Switching/Routing :: 6513 Removing AAA Command

May 16, 2012

I was working on adding a Cisco 6513 to TACACS but ran into trouble.  While I work on the issue offline (recreate and test another switch), I wanted to place this switch on radius temporarily.
 
For some reason i cant undo/delete the AAA commands in order to point to my radius server.  Below was done via console: [code]

I disabled my telemetry port on the Cisco 6513 as a precaution.  The IOS im using is "s72033-advipservicesk9_wan-mz.122-33.SXI5.bin".how to remove the AAA authentication statement.  Hope its not intrusive cause i have a customer on the box.

View 8 Replies View Related

Cisco Switching/Routing :: Catalyst 6513 NAM Module

Aug 24, 2012

i have a cisco Netowtk Analysis module installed on a 6513 core  switch which is NAM-1, the version on the NAM is 5.1 and we need to  upgrade to the latest version which is 5.1(2)

View 1 Replies View Related

Cisco Switching/Routing :: 6513 Span Session Limit?

Jul 12, 2012

I have a need to capture some traffic but my core 6513's are already using the limit of 2 span sessions. I can't edit any of the sessions either because I want to source traffic from vlans and you can only do one or the other. Is using a VACL with 'switchport capture' on the destination interface an option ? E.g. I want to source traffic from vlan 10,20,30,40 and send the all to interface Gi10/10 ? Is there any caveats ? I dont need to be too granular with the ACL's but just capture all traffic in those vlans.

View 2 Replies View Related

Cisco Switching/Routing :: 6513 - Switch To SP Mode After Reboot

Mar 20, 2013

Need your expert input in sorting out the below problem.I have a cisco 6513 switch which is going into SP mode after a reboot whci i have done during BCP activity in my organization.Below are the log for your reference.
 
Code...

View 1 Replies View Related

Cisco Switching/Routing :: 6513 Switch Boot To ROMmon

May 9, 2012

i have a Cisco 6513 it is used one, i have tryed to boot it but it did not work, it alwayes go to rommon mode and i am not able to know what is the issue,
 
when it boot i get the below outpot from the switch.
 
System Bootstrap, Version 8.1(3)
Copyright (c) 1994-2004 by cisco Systems, Inc.
Testing lower main memory - data equals address

[Code].....

View 3 Replies View Related

Cisco Switching/Routing :: 6513 Compatibility With 10GE Blades

Jun 4, 2012

I am getting conflicting info about this, and need to get confirmations.Is the older 6513 (non E) model compatible with WS-X6407-10GE blade?The switch we're getting this for have WS-SUP720-3B, 6000W power supply, and WS-C6K-13SLT-FAN2.From what I read they are compatible if entered in slot 9-13, but I also heard that 10GE modules are not compatible with the non E chassis.

View 1 Replies View Related

Cisco Switching/Routing :: Lost Port Channel Between 6513

Feb 24, 2012

We have 2 6513's that are linked via 2 10 gig interfaces, using an LACP channel.I received an alert this aft stating that the far 6513 was unreachable and the port channel int PO3 had gone down, the 2 10 gig interfaces had also gone down on either side. 5 mins later PO3 had resestablished itself and has been fine since. [code]

View 4 Replies View Related

Cisco Switching/Routing :: 6513 VTP Pruning Disabled During IOS Upgrade

Jul 11, 2011

We have a pair of 6513s and upgraded the IOS version to 12.2(33)SXI4a. After the upgrade we noticed VTP Pruning was disabled: [code] Is there any effect to production we need to to consider when re-enabling? (In other words, do we need to wait until a maintenance window to enable?)Also, we are using VTP v2 (and v1...) on our VTP Client 3560 access switches.

View 2 Replies View Related

Cisco Switching/Routing :: 6513 - Transmit Discards On Certain Interface

Feb 25, 2012

We have a Cisco 6513 Switch.  During some parts of the day it is having large amounts of transmit discards on a certain interface because of the amount of data we are pushing.  We have determined it is a link problem and not a problem with the switch.  The link cannot handle the amount of packets the switch is pushing out.  I was wondering if there is a way to create a buffer or a way to regulate the maximum amount of packets that can leave that interface without losing any packets? 

View 5 Replies View Related

Cisco Switching/Routing :: Catalyst 6513 - Scalability Of Multicast?

Aug 1, 2007

I am running a network comprising of Catalyst 6513's with SUP7203B's. at present we have 800 VLAN's as we make use of a VLAN per access layer switch model.
 
I know have a problem that as soon as I enable multicast routing my SUP720's CPU runs at 100% and the system goes into a slowdown.where I can find information on the scalability of Multicast?

View 15 Replies View Related

Cisco Switching/Routing :: 6513 Brought Down By Bridge Mode On NIC

Mar 29, 2012

We have a 6513 with about 8 switches in it. I installed a Intel Pro PT NIC in a Dell PE2850 and setup the Team setting which created a bridge in the network connections.
 
10 minutes later, every server connected on that 'blade' went down and rebooted.
 
This happened once before to another tech here (I didn't know at the time it would do this but after he saw it he pointed it out)

View 2 Replies View Related

Cisco Switching/Routing :: 6509 To 6513 Migration Required

Jan 9, 2012

We currently run 1 Cisco 6509 (CatOS) for our production network. It has multiple vlans which feed distribution switches on each floor in 2 buildings. Essentially each floor is its own vlan. Each floor switch is connected back to the 6509 via fiber connections. We also have several production vlans that our VMware and AIX environments connect to.
 
I would like to phase out the the 6509 and replace it with a new 6513 chassis, sup720's etc. Currently it is sitting next to the 6509 in the rack. I need to limit downtime as much as possible but can get one shutdown window over a weekend. However I dont think it would be enough time to move all of the existing etherconnections etc etc
 
So I am looking to run them both at the same time and slowly migrate over to the 6513 over the next few months.My solution was to use the 6513 (IOS) in L2 mode only for now and trunk it back to the 6509 via 4 1 gig connections in a LACP config.
 
So the 6509 would still be handling all of the L3 routing for now.Once I had moved all of the fiber and ethernet connections over to the 6513, I would use the shutdown weekend to configure the 6513 for L3 and essentially turn off the 6509 at that point.
 
My questions are
     - Is there a better way to do this ?
     - By trunking the 6513 to the 6509 do I need to worry about any loop issues ?
     - I am aware of the oversubscription issue for the port channel and have spread the 4 interfaces over the different groups of asics.

View 6 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved