Cisco Switching/Routing :: C3550 - Configure Loop Back Interface On Gigabit Fiber Port
Sep 14, 2012
I am trying to configure a loop back interface like so: [URL], on the following device:
C3550 Software (C3550-IPSERVICESK9-M), Version 12.2(50)SE, RELEASE SOFTWARE (fc1on port gig0/1 which is using a 1000Base-SX adapter. This is for troubleshooting purposes and it does not appear to be a feasible option. Is there another way to accomplish in the IOS?
View 1 Replies
ADVERTISEMENT
Nov 20, 2011
We have Cisco 3524XL switch, Motorola AXS1800 chassis. I am configuring this cisco switch so I can connect AXS1800 traffic thru cisco 3524XL, on switch port gigabit 0/1, I am using cisco Part no. WS-G5486 (1000Base-LX) connector to connect to AXS1800, both port are member of vlan 200 allowed, and configured dhcp-server 192.168.0.1, but still I can't ping any host or host can't get DHCP server.
View 2 Replies
View Related
Dec 26, 2011
We have Cisco 3524XL switch, Motorola AXS1800 chassis. I am configuring this Cisco switch so I can connect AXS1800 traffic thru Cisco 3524XL, on switch port gigabit 0/1, I am using Cisco Part no. WS-G5486 (1000Base-LX) connector to connect to AXS1800, both port are member of v lan 200 allowed, and configured dhcp-server 192.168.0.1, but still I can't ping any host or host can't get DHCP server. I have attached my config file for your review.
View 25 Replies
View Related
Jul 4, 2011
I notice that my Cisco switches have 2 fiber GBIC ports on them each and while i have been around networking for quite some time i have never dug that much into fiber. So after some quick googlefu i learned that there is lots of different types and compatibility problems.
The 2 switches i would like to connect are a WS-C3550-12T and a WS-C3550-48-EM.From what i have read these are 1000-base-fx?
View 7 Replies
View Related
Sep 11, 2012
Trying to configure the Cisco 4948e switch gigabit ethernet port with "switch port trunk encapsulation dot1q", but didn't get the option. Please find below the options got after "swith port trunk"............
SW(config-if)#switch port trunk ?
allowed Set allowed V LAN characteristics when interface is in trunking mode
native Set trunking native characteristics when interface is in trunking mode
pruning Set pruning V LAN characteristics when interface is in trunking mode
SW(config-if)#switch port trunk. Please find below the version of the SW............
SW#sh ver
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500e-LANBASE-M), Versi
on 12.2(54)SG1, RELEASE SOFTWARE (fc1)
Technical Support: {URL}
ROM: 12.2(44r)SG11
Hobgoblin Revision 21, Fortooine Revision 1.22
[code]...
So, whether the command is not supporting on this Cisco switch ? But we have Cisco 4948 Cisco sw where that command is working fine.
View 8 Replies
View Related
Jun 7, 2012
I have a bunch of 3750x switches that each have a 10 gig routed link back to a central 4507 (loopback = 172.30.255.255).We carved up a /24 (of course, the /24 doesn't really exist except in our address tracking spreadsheet) into a bunch of /30's for routed WAN links and /32's for loopback addresses.We started on the low end for /30 subnets (ie 172.30.255.0/30, 172.30.255.4/30, etc.).We started at the high end for the /32 loopbacks (ie 172.30.255.255/32, 172.30.255.254/32, etc.)
Well, when I try pinging 172.30.255.255 from the access layer 3750x switches, the 3750x seems to be treating it as a broadcast ping where it lists each member that responds instead of the regular !!!!! response (this makes think something is odd with the 3750x). Of course, only one member responds (the core). But even the core seems to respond with the other end of the /30 instead of the actual /32 loopback (which makes me think something is odd in the core). I could have sworn that I've setup similar topologies without problems (ie, using 10.0.0.0/32, 10.255.255.255/32, etc as loopbacks) and as long as the mask is a /32, it should work.Also, I can ping/ssh to that loopback if my laptop is on a directly connected subnet. But I can't do it from any of the 3750x switches (which are also directly connected).I've double checked for overlapping subnets, but nope. I don't see any. Routing looks fine. The actual /32 is being propagated everywhere properly.
View 3 Replies
View Related
Aug 18, 2012
The following error was seen on the switch and the Diagnostic Test Loop back failed following a new WS-6748-SFP module installation.Fabric in slot 5 detected excessive flow-control on channel 3 (Module 4, fabric connection 1)
Tried Hard reset of the module and still the error persist.
View 4 Replies
View Related
Nov 17, 2012
I have a couple a questions answers on which i cant google for a period. BTW maybe i simly use wrong aproach to choose keywords.
1) Is it possible to assign same ip address to the same client each time it authenticated, preferably without using DHCP? Im definely sure that it possible but cant find corresponded configuration examples (my device is Cisco 1921 with IOS 15.0.1).
2) Is it possible to assign dynamic crypto map to loopback interface (the purpose to make EASY VPN Server accessible through two interfaces - maybe you recommend other approach instead?) - as i move workingcrypto map from phy int to loopback - i cant connect with reason "Phace1 SA policy proposal not accepted"
View 3 Replies
View Related
Apr 6, 2012
Here is my Lab Setup: 2691 is BGP nei to R4 router and they are not directly connected. 2691 and R4 are in same AS 6500. 2691 Config---router ospf 1 network 3.3.3.3 0.0.0.0 area 0 . Its advertising its loop back IP to OSPF domain.
router bgp 6500
no synchronization
bgp log-neighbor-changes
neighbor 6.6.6.6 remote-as 6500
neighbor 6.6.6.6 update-source Loopback3
[code]...
R4 Router
router ospf 11
log-adjacency-changes
network 6.6.6.6 0.0.0.0 area 0
[ code].....
We can see that 2691 and R4 are BGP neis and 2691 has 200.1.x.x routes in its route table. My question is why from 2691 router i am unable to ping any route learned by BGP from R4?
2691Router# ping 50.1.1.0 Type escape sequence to abort.Sending 5, 100-byte ICMP Echos to 50.1.1.0, timeout is 2 seconds:.....Success rate is 0 percent (0/5)2691Router#ping 200.1.2.0 [ code]...
View 12 Replies
View Related
Feb 19, 2013
I need to NAT a port range spanning from TCP and UDP 50,000 to 59,999 from inside global address 58.96.x.x on loopback2 to an inside local address of 192.168.5.5.Currently all the existing NAT translations are 1-to-1 that map inside global addresses on a wide span of Loopbacks and a Dialer Interface to inside local addresses on few subnets which are fine.I'm using an 1811 with an ADVIPSERVICESK9-M image, version 12.4(6)TS
View 1 Replies
View Related
Jul 4, 2012
How to create loopback cable for gig copper port (cisco 6513).I
View 3 Replies
View Related
Oct 8, 2012
i have a strange problem in my campus network.im trying to run port security on my access switches which they are 3550 with ios c3550-ipservicesk9-mz.122-52.SE when i run the port security with Sticky option, even i put 1000 mac address for just learning on the port but when i issue the switchport port-security command every pc connected to that port loses its connection with network UNTIL i enable dhcp snooping!!! all my client are getting they ip address from DHCP server but strange thing is that how on earth i have to enable DHCP snooping to port security work properly? also when i check the configuration under the interface when dhcp snooping is not yet enabled switch doesnt add any mac address under the interface so no one can work until i enable snooping and then switch adds mac addresses under the interface configuration.is this Bug on this version of IOS?[code]
View 4 Replies
View Related
Jan 12, 2012
how to configure this. I did it in the past but kind of forgot how I did it.I have a stacked 3750 (two physical switches) connecting to a 2960.
I am creating trunk ports with limited access to VLAN 300, 600, and 700.
There is two interfaces connected from the 3750's(one on each physical stack member) to the 2960.I have the physical interfaces configured exactly the same.
3750 Config:
interface Port-channel2
!
interface FastEthernet1/0/46
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1, 300,600,700
switchport mode trunk
speed 100
[code]....
Should I keep the configuration on the physical ports and not configure the Port-Channel Interfaces? Do I need to configure port-channel load balancing? Is the channel-group mode sufficient? Goal is to basically create 2 links to the 2960 to double the bandwidth and provide redundancy.
View 7 Replies
View Related
Oct 26, 2012
we are bringing up new ckt and nexus 7000's interface isn't coming up once telco gave a loop. and wee following msg when I do "sh int eth1/1".
(UDLD Tx Rx loop, port: error)
what does "(UDLD Tx Rx loop, port: error)" it mean?before loop. interface was showing as "Link not Connected".
View 2 Replies
View Related
Jan 16, 2011
is it possible to assign a loopback address to a typical switch port on a 2950 switch? I want to be able to have some devices connected to a switch to test access lists and VLANs.
View 3 Replies
View Related
Oct 26, 2011
We have a number of 3845 routers, some running IOS 12.4(22)T2 and earlier and some running 12.4(24)T4. On the ones with 12.4(22)T2 and earlier, gigabit interface g0/1 shows interface down/line protocol down when there is no cable connected to the interface and the interface is not in shutdown state. On the ones with 12.4(24)T4, gigabit interface g0/1 shows interface up/line protocol down when there is no cable connected to the interface and the interface is not in shutdown state. Interestingly in both cases, the "show controller g0/1" command shows " network link is down (NO CARRIER)" when there is no cable attached. It makes sense to us that the interface status would be down/down when there is no cable attached. It does not makes sense to us that the interace would be up/down. Did Cisco at some point change their philosophy on whether an interface should show down/down or up/down when there is no cable attached, or is this a bug?
View 1 Replies
View Related
Oct 22, 2011
Recently we got a cisco catalyst 4500 and six 2960 access switches. I need assistance on configure spanning-tree and faster convergence on my network to avoid loop.
[code]....
View 10 Replies
View Related
Jan 19, 2012
I have a 3925 Router with a 48 port switch module (part number SM-D-ES3G-48-P). I have no problem accessing the 3925 Router, but when I go into the 48 port, I get an error that reads
Error Hardware not supported by firmware. Try loading a newer software instead. System Resetting...
I know that the wrong IOS is installed on the switch, but the problem is that this is an endless loop. The switch resets then comes back to the same error. How to get the switch out of this loop so that I can load the correct IOS.
View 1 Replies
View Related
Feb 12, 2012
On a 6500 switch running ios 12.2, is there a way of clearing all config settings for a specified interface? I want to avoid going through and having to type "no blah blah etc" for each line.
View 2 Replies
View Related
May 18, 2013
I have a question about speed negotiation process between interfaces. I have 3650X Sw and 2960S-48port. All ports of two are GigabitEthernet, however the link between them is only 100Mb/s, Full duplex. I try to set the speed 1000 Mb/s manually in the interface then the interface never up. Its status is down/down. I must set back to speed auto. I show interface Gigabit0/24 in Sw 3650-X and figure out that there are many output drop (over 600000). I clear counter then after two days the output drop is over 70000. This link is trunk link between two switches, all ports of access SW are Gigabit and connect to PC. First, I thinks the 3650X is throttled somewhere in output direction of trunk link. But there is another trunk link (Gi0/23) to another 2960S-48port and no output drop number in this interface. This Giga 0/23 speed is 1000 Mb/s (auto speed, auto duplex)
Does any outside things impact the speed negotiation process between 2 interfaces? And output drop number may caused by abnormal speed between two Gigabit interface?
View 1 Replies
View Related
Dec 12, 2012
I have a WS-X6816-10G-2T module with X2-10GB-SR modules. I will be getting a SMF hand off and the length of the termination is around 100 meters. (I will be getting another hand off for Inter-DC link for which I have X2-10GB-LR module). The question is can I connect this SMF hand off (short length) on the SR module?
View 2 Replies
View Related
Jan 14, 2013
I need Know what connection is using on Cisco 2811 router.I have this interface in Cisco 2811, I need Know if this port is connected to Fiber or Copper. I think is copper with RJ45 but I see 100 base TX/FX so this make me doubt about it because TX its for copper link and FX for fiber. [code]
View 5 Replies
View Related
Jun 18, 2012
We would like to setup a link to our DR site that is separate from our main network traffic. This link will be used by an EMC VNX SAN for replication traffic. The SAN will be plugged into a fiber port on a 3750 switch and going out from the same switch (going in as multimode, going out as single mode) into a patch panel that runs over to the DR site (about a mile away). At the DR site it will go from the fiber panel into another 3750 switch which ends up going back out of that switch into our DR SAN.
I'm wondering what the best way would be to configure the fiber ports to accomplish this. I'm affraid that the replication traffic will find it's way over through another route and congest our main network unless configured appropriately.
View 4 Replies
View Related
Mar 12, 2012
Brand new 2960. When I plug a cable into the port, nothing happens. The port light doesn't begin negotiation or anything, it just stays dark. The cable works fine--I have it on another switchport with a crossover connector connecting to a little Cisco SOHO switch without problems.
I've done the following:
switchport
switchport mode trunk
switchport trunk allowed vlan 1
no shutdown
In other words, I've fiddled with it. But I don't know why it doesn't light up..
View 1 Replies
View Related
Feb 19, 2012
In one location we have a HP 2510-48 port switch which we need to connect to a Cisco 3560 switch. The problem I have is that we have issues connecting fibre to the HP switch, so I have decided to attached a CAT 5 to Fibre convertor at this end and another to the cisco switch.
My question you can not connect a HP switch to a Cisco switch, is this true or do I just need to confirgure something on the ports.
View 2 Replies
View Related
Sep 4, 2012
We have a core switch with the following ios and supervisor engine. Can we add a16 port LR (x2)or LRM(X2) ON the core switch?if not what modifications has to be done?if an ios upgrade is necessary is it a costly affair?At present we have two 1gb up link modules in single and multimode fiber .
#sh moduleMod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ ----------- 1 16 SFM-capable 16 port 1000mb GBIC WS-X6516A-GBIC SAL0803T308 2 48 SFM-capable 48 port 10/100/1000mb RJ45 WS-X6548-GE-TX SAD07500600 5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1439UMZK
#sh versionCisco IOS Software, s72033_rp Software (s72033_rp-IPBASE-M), Version 12.2(33)SXI4a, RELEASE SOFTWARE (fc2)Technical Support: [URL] Copyright (c) 1986-2010 by Cisco Systems, Inc.Compiled Fri 16-Jul-10 19:51 by prod_rel_team
ROM: System Bootstrap, Version 12.2(17r)SX7, RELEASE SOFTWARE (fc1) uptime is 1 year, 27 weeks, 4 days, 23 hours, 30 minutesUptime for this control processor is 1 year, 27 weeks, 4 days, 22 hours, 58 minutes(code)
View 6 Replies
View Related
Dec 29, 2012
I have a Cisco 2851 router and need an additional gigabit Ethernet port. How to get the part number I need to order?
View 3 Replies
View Related
Apr 12, 2012
Is it possible to reset this switch oif yo uare unable to get into the console or web interfaces?
View 2 Replies
View Related
Jan 7, 2013
We have recently purchased a Cisco 4506 that has several Gigabit Ethernet modules installed.One of the Ethernet Gigabit modules - a WS-X4424-GB-RJ45 - is being picky with who it talks to at Gigabit Ethernet.
If I plug a laptop into one of it's RJ45 ports using a Cat 6 cable, nothing happens. No link light, no notification of link up or down on port statistics, absolutely nothing.If I plug a server into the same port it works fine at Gigabit Ethernet (even using the same Cat 6 cable).I can get the module to recognize a laptop if I fix the speed/duplex on the laptop to 100Mb/Full. I have tried this with other staff laptops from different vendors (HP / Dell / etc.) all with the same result.
The module directly underneath this module - a WS-X4448-GB-RJ45 - works fine for both laptops and servers. We have tried swapping the module positions but to no avail.
View 9 Replies
View Related
May 21, 2013
Has anyone configured Layer 3 port channel on Cisco 6509 switches which are connected over dark fiber between two buildings?
View 3 Replies
View Related
Sep 24, 2012
We recently upgraded the switch to which an old security device was connected. It worked fine on the old switch's FastEthernet port, which was configured for speed 10 and duplex half, as that is what the device required. The new switch is a 3560X with all Gigabit ports, but the security device's port, also configured with speed 10 and duplex half, does not connect properly.As a temporary test, we daisychained another switch that has FastEthernet ports, and the security device works again.Is there anything else that needs to be added to the configuration, when using Gigabit ports at 10/half?
View 4 Replies
View Related
Jun 15, 2012
We have multiple cisco cat 2900 switches. all switches don't have cascade cable port in back panel. i want some sort of solution to manage those switch remotely.
View 9 Replies
View Related
Nov 25, 2012
I have a Cisco 8510msr that is connected back to back with a 7206vxr across a 155Meg connection.I receive lots of Output drops on the 7206vxr interface facing the atm switch. When I do the following command:-
kwdair9#sh atm int atm 1/0Interface ATM1/0:AAL enabled: AAL5 , Maximum VCs: 4096, Current VCCs: 27 Maximum Transmit Channels: 0Max. Datagram Size: 4528PLIM Type: SONET - 155000Kbps, TX clocking: LINECell-payload scrambling: ONsts-stream scrambling: ON797522 input, 881483 output, 203946630 IN fast, 223768062 OUT fast, 0 out dropVBR-NRT : 110288 Avail bw = 44712 <====
I only have 44megConfig. is ACTIVEkwdair9# I only get 44Meg of the available 155Meg.There is no QOS on the router and the only commands I can find that vaguely see that refer to QOS are on the ATM switch:-
atm address 47.0091.8100.0000.0007.0d87.b201.0007.0d87.b201.00atm router pnnino aesa embedded-number left-justifiednode 1 level 56 lowest redistribute atm-static?why this is acting like a DS3 link and not a 155Meg link?
View 4 Replies
View Related