Cisco Switching/Routing :: C3750-48PS Switch Is Stuck In SYST Mode On Front Panel
Dec 13, 2012
After powering up a WS-C3750-48PS switch, Normal POST LED flashing of lights does not happen, instead the switch is stuck in SYST Mode on the front panel. My attempt to hold down the mode button upon powering up for 15 sec fails to reboot the switch. I cannot console to the switch. Is this switch unrecoverable? Should I RMA with TAC?
View 5 Replies
ADVERTISEMENT
Apr 17, 2013
I have production stack in the following config:
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 52 WS-C3750-48P 12.2(25)SEE4 C3750-IPSERVICESK9-M
2 52 WS-C3750-48P 12.2(25)SEE4 C3750-IPSERVICESK9-M
I want to add 3-rd switch to it:
Switch: WS-C3750G-48PS 12.2(25)SEE3 C3750-IPSERVICESK9-M
Will this configuration work? My main concern is IOS difference?
View 3 Replies
View Related
Mar 3, 2013
I have 3750-48PS-S in production and would like to stack it with C3750G-48PS. Both switches are running code:
c3750-ipservicesk9-mz.122-50.SE3.bin
View 3 Replies
View Related
Feb 16, 2013
I have 2 - WS-C2960-24TT-L switches. Both are experiencing the same issue. Upon booting them up, all lights flash on the mode indicator panel, then it goes directly to a solid green "SYST" light. Nothing registers across the console cable. I have tried different baud rates, cables and computers. None of the ports come up regardless of how long either switch is powered on. Holding the Mode button during boot up produces the same result, nothing. Sounds like they are dead, however, I thought this would be the place to go for ideas. Can I revive these switches?
View 3 Replies
View Related
May 19, 2010
I'm having trouble connecting via ethernet to my WAG200G. Everything was working fine a week ago but now, nothing.The problem is only occurring with one computer and I've tried the troubleshooting guide on the website to no avail.When I connect the ethernet cable from my computer to the modem/router, I don't get a light on the front panel on any of the ports. I've changed cables, ports, disabled ZoneAlarm and firewalls and nothing comes up. I've checked the ethernet connection from the computer to another computer and it's working fine.
On a different computer, I have no trouble connecting to the ports and can confirm that 1-4 are working and the lights come up.
View 6 Replies
View Related
Oct 11, 2012
I have a new building to add to our campus and I have been encouraged to run single mode fiber. All of my other buildings are connected with multi-mode fiber. I just want to make sure i will not have an issue if I run single mode to the new building with SM SFP's.
View 2 Replies
View Related
Dec 6, 2011
I have stacked WS-C3750E-24PD with Ten Gigabit Ethernet ports configured under ether-channel. It has c3750e-universalk9-mz.122-55.SE1.bin IOS installed on it. One of the Ten Gigabit Ethernet ports, goes to err-disable mode with following errors on that specific ports.
%SFF8472-5-THRESHOLD_VIOLATION: Te1/0/2: Tx power low alarm; Operating value: -31.0 dBm, Threshold value: -9.0 dBm.
%SFF8472-5-THRESHOLD_VIOLATION: Te1/0/2: Tx power low alarm; Operating value: -31.0 dBm, Threshold value: -9.0 dBm. (DROmx-1-1)
I have gone through some of CSC forums like {URL}. The workaround is to "Remove the X2 or SFP from the inactive up link port" which is not in my case.
View 9 Replies
View Related
Dec 16, 2012
I have 6509 E. Actually what happen it last 3-4 times it reload its self and got stuck in rommon mode, i tried to boot it with boot by connecting a console cable on supervisor 720 2b. What and where is problem and why is stuck in rommon after reload.
View 11 Replies
View Related
Jan 25, 2013
My Cisco seems to be stuck when it boots up, with the following:
Upgrade ROMMON initalized
And it goes on with self comperessing image then an OK but then it starts loading again all over.
View 13 Replies
View Related
Feb 8, 2012
We've just purchased a WS-C3750-24FS-S, only to find that the 100baseFX ports will not work over Single Mode fibre, backhaul links. Any way or a device that convert from MM to SM?
View 2 Replies
View Related
Jan 16, 2012
I had a strange issue yesterday when onsite installing a new access switch.Port capacity full on a two switch stack of 3750 x48 PS switches (WS-C3750- 48PS-E)- New 2960 x48 PS - WS-C2960S-48FPS-L racked, with the plan of using it just as an edge switch via SFP Stacking cable.Setup the two connecting ports with simple initial config: - switchport mode trunk- no encapsulation option on the 2960, default dot1q- dot1q set on 3750 port- no shut on both sides.Connected the SFP Stacking cable but it didnt work:- %PHY-4-SFP_NOT_SUPPORTED: The SFP in Gi1/0/1 is not supported
This is ok as I had a backup:- Next step tried using 2 x Short Haul SFP SX GBIC's with LC - LC OFNP 50/125 fibre patch lead - no joy- Extra backup of 2 x Long Haul SFP LX GBIC's with the same fibre patch - no joy- Checked the fibre and it was not a cross over so transmit and receive going down the same side, switchedand still would not come up.- Used Fibre as a straight through and still the same.In all cases there was no indication of any life in the connection.It is pointing to a faulty fibre patch lead but I know it has worked in the past. Could it be something to do with the config or device incompatibility? Or any setting I need to activate?
View 1 Replies
View Related
Mar 13, 2011
We have existing stack of 3 units of WS-C3750-48TS-S ( 100 mbps ports with Gigabot uplinks). with IOS as follows, Can we add WS-C3750G-48PS-S in this same stack (this is 48 Gigabit ports)?
View 2 Replies
View Related
Jun 13, 2013
We have several of these WS-C2960S-24PS-L running 12.2(55)SE5 C2960S-universalK9-M and need to upgrade to a better.IOS since we have a sitution where CPU would get to 100% but we have only a few ports connected.Also we have several of WS-C3750-48P running 12.2(55) SE6 C3750-IPBASEK9-M.
View 3 Replies
View Related
Nov 27, 2012
a) I have three C3750-X switch stack together as my SAN switch and running on the new 15.0 release which is 15.0(1) SE.
b) Recently the master switch rebooted without any explanation. Create ticket with TAC and got an answer that it is due to a bug with ID: CSCtr31957.
My question is, which release that should i choose either the 15.0(1) SE3 or the latest 15.0(2)? Will it affect any of my configuration if i change to 15.0(2)?
Finally, what is the best practice to upgrade IOS in a stack whether to upgrade it 1 switch at a time or do it to all at once?
View 3 Replies
View Related
May 19, 2013
Our client having one c3750 with ipbase license switch.They are connected server and end switches to that switch.Our customer want to increase the speed to accessing the server at that time I am told to use etherchannel.Customer happy about this and implement the etherchannel configuration.Now i need to configure etherchannel upto 4 physical link.server are connected on port no Ge1/0/10,they want to bind four phical link GE1/0/10-13.how to configure etherchannel in this switch?
View 1 Replies
View Related
Apr 10, 2012
Is there a way I can downgrade the firmware on a C3750 v2 switch 24TS-S v07 to 12.2(35) SE5. I have added this new switch to an existing stack but the FW is not compatable. I believe the answer is to upgrade the rest but I cannot afford any down time as they are used to run a CCTV securiy network 24/7. I have included details below to assist with my problem. Switch 4 is the one with a version miss match.
LNB-SWI3750-CTR-01#show verCisco IOS Software, C3750 Software (C3750-IPBASE-M), Version 12.2(35)SE5, RELEASE SOFTWARE (fc1)Copyright (c) 1986-2007 by Cisco Systems, Inc.Compiled Thu 19-Jul-07 19:15 by nachenImage text-base: 0x00003000, data-base: 0x01080000
ROM: Bootstrap program is C3750 boot loaderBOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(25r)SEE4, RELEASE SOFTWARE (fc1)
LNB-SWI3750-CTR-01 uptime is 19 weeks, 3 days, 22 hours, 46 minutesSystem returned to ROM by power-onSystem image file is "flash:c3750-ipbase-mz.122-35.SE5/c3750-ipbase-
[code]....
View 5 Replies
View Related
May 31, 2013
I have 3 ws-c3750-48ps in a stack and i'd like to enable dot1x on the stack I entered the commands: [code] I also have dot1x enabled on several interface on the 2nd and 3rd switches in the stack with these commands [code] dot1x successfully works on these ports and I see the logs in acs, heres where the problem comes in when i try to enable dot1x using the above commands on any interface on the first switch in the stack it doesn't work its like the switch doesn't support dot1x. I'm assuming that there is a bug in version 3 but after googling I didn't come up with much.
View 6 Replies
View Related
Jul 27, 2011
Whenever I add devices in CiscoWorks and do not manually specify the device type. CiscoWorks find itself wrong device types for it, For example I have found that mostly it classify WS-C3750-48PS-S as below device types; [code]
Also found that WS-C3560-24PS-S discovered as 7600 series routers.
View 3 Replies
View Related
Nov 12, 2011
Why I cannot ping vlan when no port connect to switch.
View 3 Replies
View Related
Mar 18, 2012
I am using 802.1x authentication with multi-domain ports; Phone and PC connected to phone. The phones are Nortel (Avaya) and the PCs are Dell/HP Laptops. All are configured for Certificate authentication and this works well. However we sometimes get some ports stuck in Guest mode. when a non certificated laptop connects to a phone port and fails authentication, the data port is placed in the Guest VLAN. However when the laptop disconnects the port isn't reset and remains in the guest state. When a subsequent good laptop connects and attempts to authenticate the switch ignores this and leaves the data port in the Guest VLAN. he switch is a 2960S with Version 12.2(58)SE2 IOS.
The port is configured as follows:
!
interface GigabitEthernet1/0/15
description DANS Port
switchport access vlan 1807
switchport mode access
switchport voice vlan 1855
priority-queue out
[code]....
I placed the AAA, dot1x, eap and auth debug on for all events and then connected a good laptop, the only debug message I got were as follows:
Mar 19 16:17:01.391 GMT: AUTH-EVENT (Gi1/0/15) dot1x_switch_is_restrictive_vlan_open_auth:Multi-Host with Guest Vlan/Auth Fail Vlan or open aut
Mar 19 16:17:01.653 GMT: AUTH-EVENT (Gi1/0/15) dot1x_switch_is_restrictive_vlan_open_auth:Multi-Host with Guest Vlan/Auth Fail Vlan or open aut
Mar 19 16:17:02.654 GMT: AUTH-EVENT (Gi1/0/15) dot1x_switch_is_restrictive_vlan_open_auth:Multi-Host with Guest Vlan/Auth Fail Vlan or open aut
[code]....
I would have expected the auth function to have reacted to the EAP packets sent by the good client when it connected and performed eap authentication but it didn't, all it did was say the ports in Guest mode and left the laptop in this VLAN.
View 2 Replies
View Related
Mar 20, 2013
Need your expert input in sorting out the below problem.I have a cisco 6513 switch which is going into SP mode after a reboot whci i have done during BCP activity in my organization.Below are the log for your reference.
Code...
View 1 Replies
View Related
Oct 3, 2011
There is no wireless switch on the front of my Toshiba Satalite A 100-596 Model. How do I turn on Wireless?
View 1 Replies
View Related
Sep 26, 2011
the F8 ket isn't working, but I am sure there is no wireless switch on the front of my tosbhiba satellite laptop.
View 1 Replies
View Related
Oct 14, 2012
We have two 6500 core switches and one(primary) of them is running in VTP transparesnt mode and the other (secondary) one is running in VTP client mode. I would like to change the VTP mode of the second switch to transparent mode. Would it cause any issue. I guess i have to create VLANs onto the switch.
View 7 Replies
View Related
Nov 3, 2012
I have found that the Catalyst 2955 series switches do not use an external MODE button for getting a switch into the switch: prompt, but they use a break sequence like routers do to get into Rommon state URL
So I was wondering if there is a similar mecanism that applies to other kind of Catalyst switches, like 2960, 3560 or 3750.
View 7 Replies
View Related
May 18, 2012
The following discussion is based on cisco cat 6500 switches with two power supplies: p1 and p2. . Both power supplies are running in combined mode .Each power supplies is rated with 500 watts max( I just picked 500 watts for simplicity)Combined mode In combined mode, each power supply provides approximately 83% of its capacity to the chassis. This allows for greater utilization of the power supplies and potentially increased PoE densities
1) Let say our specific 6500 switch's configuration requires 1000 watts. We have two power supplies p1 and p2 ,each with rated power of 500 watts. Both power supplies must operate in combined mode. Will power supplies be able to meet the total load power requirement of 1000 watts?
Here is my understanding :The maximum power delivered by each power supplies is 83 percent of its rated power, assuming power supplies are running in combined mode.
So Maximum power delivered by power supplies
= 83% of p1+ 83% of p2
= 83% of 500 + 83% of 500
= 415 +415
=830 watts
Thus the required load of 1000 watts can not be met by our power supplies in combined mode.
2 )Suppose our switch's switch configuration needs 500 watts. Again our power supplies each rated with 500 watts, are configured for combined mode. How much power is being delivered by each power supply? Is it 83 percent of the total load i.e 500 watts?
View 4 Replies
View Related
Nov 18, 2012
Two Cisco 3750X can be stacked together to ensure redundancy.Is the attached topology feasible for access layer redundancy?
View 5 Replies
View Related
Jul 17, 2012
I have 2950 switch booting through MOnitor Mode.Analyzed there is no Cisco IOS image in flash.
View 1 Replies
View Related
Jan 24, 2012
I have a 3550 switch that was replaced at a remote site with no IOS. This is a switch not a router so tftpdnld does not work.
[Code]...
The problem is the switches interface never comes up so try to connect to the tftp server. I read on google it can't be done on a switch to copy from tftp to flash in rommon mode on a switch and to use XMODEM. My problem is I do not have access to it, I ssh into a 3640 which is an access server for all devices and that is how I have console to it, how to use XMODEM over ssh.
But I'm fairly certain that there has to be a way to just copy it from tftp? I have a 3550 local and when I put it in rommon mode it stops the port check at port, port 1 goes from green when you plug it in to off then port 2 changes to amber and the rest green. So just by the look of this I would believe tftp would work; you just need to use port 1.
View 1 Replies
View Related
Sep 11, 2012
I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not. Also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Any other way to update it. Master switch has new boot path but unable to change in slaves.
View 2 Replies
View Related
Dec 7, 2011
We recently connected a RPS 2300 to our switch WS-C3750G-48PS-E with IOS c3750-ipservicesk9-mz.122-53.SE2.bin.However i do not see any RPS details in the"show env" output.I believe i should get the RPS Name and its Serial and the port number in the output, but i am not finding it in the output. I did reload the switch but still couldnot get this udpated.
View 3 Replies
View Related
Jun 19, 2012
I'm trying to get an IP_ADDR set on the management port in SWITCH: mode but for some reason the port seems disabled. PC shows connection unplugged. MGMT_INIT is not a valid command (not listed under '?' ). Bootloader version is 12.2(53R)SE2 FC1.
View 4 Replies
View Related
Nov 28, 2012
We have a cisco catalyst 6509 with Supervisor Engine . After power outage, the switch always start in Rommon mode. Configuration register is 0X2102, we want to it always start in normal mode. What should i do?
View 3 Replies
View Related