I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not. Also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Any other way to update it. Master switch has new boot path but unable to change in slaves.
We recently connected a RPS 2300 to our switch WS-C3750G-48PS-E with IOS c3750-ipservicesk9-mz.122-53.SE2.bin.However i do not see any RPS details in the"show env" output.I believe i should get the RPS Name and its Serial and the port number in the output, but i am not finding it in the output. I did reload the switch but still couldnot get this udpated.
I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not.also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Master switch has new boot path but unable to change in slaves.
I want to upgrade the IOS version of 3750 48PS switches. these stacks are located on different building some of the them having 2 members and some have 3 members in a stack.step by step to upgrade the IOS of these switches.
I recently removed a catalyst 2950 switch code version: c2950-i6q4l2-mz.121-13.EA1 ?I had an ASA 5505 connected as a switchport access to the 2950 on port 44. We will call the VLAN that the ASA sits on: VLAN 404. The 2950 had a trunk to our catalyst 6509 distribution switch carrying that VLAN 404. We also have a another VLAN for computers that sits on: VLAN 129, this is a standard DHCP vlan and it accounted for the rest of the switchports. The 2950 also has this trunked to our 6509 distribution switch.
Everything was working fine with that setup.After replacing the 2950 with a 3560 we started running into problems. The 3560 was configured the same exact way as the 2950. What was happening is that computers that sat on VLAN 129 started experiencing packet loss and were unable to work. It's as though the ASA was taking over the switch.
Is there a protocol that is enabled by defult on the 3560 that would do this?
I would like to know if Catalyst WS-C3750G-48TS-E recognizes and understand Cisco VSS ( Virtual Switching System) . Is there a List available which tells us which Old Catalyst Switches or current switches understand Cisco VSS?
We had some problems with 3560G-48PS-S switches and PoE for our phones. IOS is 12.2(50)SE3. There were some problems after power outage. The switches didn't reboot because we have two eletric circuits. But after the problems we had no PoE on all ports.
The switches logged to following syslog message:
%ILPOWER-3-CONTROLLER_PORT_ERR: Controller port error, Interface Gi0/17: Power Controller reports power supply VDD under voltage
I can't find any informations in the error message decoder for that. But there was another thread here with quiet the same message, but another problem regarding RPS2300.
After reloading the device all works fine again. The workaround with the commands "power inline never" and "power inline auto" I didn't know till today.
Some information about that syslog message?
My guess is that there was a voltage swing and the switch powered down its supply? Is that possible?
In my office we bought 7 cisco 3750X - 48PS switches. We configured Data Stacking between those switches. We also want to configure Power Stacking between those 7 devices.
I found in the Data Sheet that we can only configure 4 devices in power stacking at a time. If it is like that how to configure the rest of 3 devices. Need configuring power stacking between those devices in a better way..
power stack cable part no we have is CAB-SPWR-30CM
We are using WS-C3560G-48PS connected via UPS power supply. Whenever raw power supply gets fluctuates few of the IP phones (Alcatel) gets reset although switch is remain up and running. We checked the same by disconnecting the raw power supply but we didn't found any packet loss from the node which are connected through this switch. But few IP phone gets reset. What could be the reason
I have a 3750-48P when plugged in has fans that spin up, but no lights on the front of the chassis. Does this mean the power supply is bad? If its bad, why do the fans power up? Also, i am not receiving any data through the console.
I have a switch 3560v2 with an IOS 12.2(50) SE1.All the lights ON and console error message below:POST: inline power post failed for port 0 up to port 15.Then, the system hanged and all lights (indicator) ON.
I need to replace an older 3560 with a new 2960-S and am wondering if the SX SFPs I already have will be compatible with the 2960-S. [code] I cannot find any way to get the part numbers of the SFPs.
Currently there are three stacked WS-C3750G-24TS-1U on data centre. I am going to buy a WS-C3560X-48T-L to use 10GbE module. Is it possible stack this switch "WS-C3560X-48T-L" to current switches "WS-C3750G-24TS-1U" ?
I have a process whick take all the CPU on two differents Stack of WS-C3750G in version 12.2.53(SE2):
XFRPALSN02R#sh proc cpu sorted CPU utilization for five seconds: 97%/3%; one minute: 95%; five minutes: 95% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 307 5450059 4167397 1307 86.74% 83.63% 83.35% 0 hulc nrgyz PD di XFRPALSN02R#sh proc cpu sorted CPU utilization for five seconds: 96%/3%; one minute: 96%; five minutes: 96% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 307 7779608 5947379 1308 86.26% 85.75% 85.30% 0 hulc nrgyz PD di
#show version Cisco IOS Software, C3750 Software (C3750-IPSERVICES-M), Version 12.2(52)SE, RELEASE SOFTWARE (fc3) Copyright (c) 1986-2009 by Cisco Systems, Inc. Image text-base: 0x01000000, data-base: 0x02C00000 ROM: Bootstrap program is C3750 boot loader BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(44)SE5, RELEASE SOFTWARE (fc1)
[code]...
I have downloaded c3750-ipservicesk9-mz.150-1.SE2.bin and I want to upgrade iOS to this image.
I have a few questions related to this:
1. Is my switch model compatible with this iOS version?
2. Do you recommend the upgrade? Does it bring some notable features?
3. Can I upgrade for free or do I need to buy some license?
4. I also want to upgrade/add the crypto image, can I add crypto for free or some license is required?
5. I have remote access to my switch via the console cable which plugged into machine1. But machine1 is connected to network via the same switch. I am accessing machine1 via SSH, and then the switch via console cable (minicom on CentOS). Is there an upgrade procedure for this kind of situation that also has some fall back (like reboot in X minutes and load the previous image) if the upgrade goes wrong?
I have configured DHCP snooping on a WS-3560G-48PS running IOS 12.2(58)SE2 ipservicesk9 variant.When I enable DHCP snooping clients don't get IP addresses, when DHCP snooping is disabled, everything works fine.I have set up a SPAN port and run a capture (attached) on the traffic. Wireshark notes the Seconds elapsed field appeared to be encoded in little-endian but only on some packets. Apart from that, I can see nothing wrong with the DHCP Offer responses from my DHCP server.Attachment config.txt contains the interesting parts of the configuration. Please note g0/32 has been set to ARP inspection trust as without working DHCP snooping it would require a static bind.Is there any way of figuring out which option can't be parsed? Is there a way to force forwarding of unparsable DHCP packets while still running DHCP snooping?
I had a strange issue yesterday when onsite installing a new access switch.Port capacity full on a two switch stack of 3750 x48 PS switches (WS-C3750- 48PS-E)- New 2960 x48 PS - WS-C2960S-48FPS-L racked, with the plan of using it just as an edge switch via SFP Stacking cable.Setup the two connecting ports with simple initial config: - switchport mode trunk- no encapsulation option on the 2960, default dot1q- dot1q set on 3750 port- no shut on both sides.Connected the SFP Stacking cable but it didnt work:- %PHY-4-SFP_NOT_SUPPORTED: The SFP in Gi1/0/1 is not supported
This is ok as I had a backup:- Next step tried using 2 x Short Haul SFP SX GBIC's with LC - LC OFNP 50/125 fibre patch lead - no joy- Extra backup of 2 x Long Haul SFP LX GBIC's with the same fibre patch - no joy- Checked the fibre and it was not a cross over so transmit and receive going down the same side, switchedand still would not come up.- Used Fibre as a straight through and still the same.In all cases there was no indication of any life in the connection.It is pointing to a faulty fibre patch lead but I know it has worked in the past. Could it be something to do with the config or device incompatibility? Or any setting I need to activate?
I have a c3560 that on Port 1 I can not get any device to talk to the DHCP server.Previously there was a client connected to this port however over the weekend he stated he lost connectivity.
In my troubleshooting I have connected that client to another port and now he is good to go...I connected my laptop and tried to connect to the network however I could not.I checked the logs and did not see anything that lead me to think it was having problems.
Is there another way to shut this down and hopefully start it back up without having to restart the entire switch?
We are facing since one month in our two Cisco WS-C3750G-12S on many interfaces input errors when data transer or ping (ICMP) increase input erros. Not only port 1 but many interface has same issue, i have change new IOS but still same issue, once i have erase startup config but same issue we are facing and finaly i have replace same new switch with the same IOS it's working fine.(c3750-ipservicesk9-mz.122-55.SE4.bin) [code]
I currently have a C3750G connected to a C3560G with default auto-negotiation settings. Ports are up and connected a-100 and a-full. I am trying to change the ports speed to 1G, and have tried all possible combinations of "speed 1000" and "duplex full" setting on both ends to no avail. What should port settings be for 1G speed between the two switches?
Here are the current port settings:C3750G: interface GigabitEthernet1/0/1 switchport trunk encapsulation dot1q
i have a Layer3 Switch Cisco WS-c3750G -24T , initially i have a IOS version c3750-Ipbase , recentely i have upgraded my IOS to c3750-Ipservices-M to enable to PBR for my network , i have created all the acl and tried to give the route-map with PBR , the command was initiallying but i am not able to see the applied route-map in my policy route , i have gone through the blog and enabled SDM prefer routing , but no luck .
can i stack cisco (ws-c3750G-12s) with (ws-c3750X-24p-poe-s) with (ws-c3750-48p-10/100 poe) i mean even a switch is 10/100 and the other switch is 10/100/1000?
I'm having trouble stacking a new WS-C3750X-24P with existing switches WS-C3750G-24PS ?I can see the license is on the new WS-C3750X-24P:
switch#sho lic Index 1 Feature: ipservices Period left: 8 weeks 4 days License Type: Evaluation License State: Active, Not in Use, EULA not accepted License Priority: None
[code].....
I could put on the c3750e-ipbasek9-mz.122-55.SE1 image, but I may need to get the license sorted still, but not sure if that will work or how to add it if i got one.....
After powering up a WS-C3750-48PS switch, Normal POST LED flashing of lights does not happen, instead the switch is stuck in SYST Mode on the front panel. My attempt to hold down the mode button upon powering up for 15 sec fails to reboot the switch. I cannot console to the switch. Is this switch unrecoverable? Should I RMA with TAC?
I have issue about Wireless controler , i have 2x WS-C3750G-24WS and 1x AIR-CT5508-50-K9 , i have max 50 access point license and i can't upgrading because WS-C3750G-24WS is and of life , can i use AIR-CT5508-50-K9 with 3750G to work together? , mobility and everything....
I have two Switches which i need to put in a same stack - WS-C3750E-48TD and WS-C3750G-48TS . Possible to do so and also which IOS to put in both the switches as WS-C3750G-48TS is having lower RAM and flash.Whether can i put following IOS in these switches and connect them in a stack as i have read that IOS -- 15.0.1. SE are compatible with both the switches.
a . c3750e-ipbasek9-mz.150-1.SE.bin in switch - WS-C3750E-48TD
b. c3750-ipbasek9-mz.150-1.SE.bin in switch -- WS-C3750G-48TS
I do have C3750G-12s switch which is not able to boot as of the expected. Every time when I break the stack and try to use console i got a weird output from my console output. we need the stack to be break and use those switch separtally .
I have 8 switch stack consisting of six WS-C3550-48P and two WS-C3750G-16TD running software vesrion 12.2(25) SEB1. When I added new C3750v2-24PS (running image 12.2(50) SE5) in stack so I up-graded the image of existing 8 switches with latest veriosn 12.2(50) SE5. Once I have done with the upgrade then all ports of my stack switches went down after around five minuts. Is it image compatibility issue with existing switches or something else?