Cisco Switching/Routing :: Can Stack C3560x To C3750g
Jan 11, 2012
Currently there are three stacked WS-C3750G-24TS-1U on data centre. I am going to buy a WS-C3560X-48T-L to use 10GbE module. Is it possible stack this switch "WS-C3560X-48T-L" to current switches "WS-C3750G-24TS-1U" ?
View 1 Replies
ADVERTISEMENT
Feb 3, 2012
can i stack cisco (ws-c3750G-12s) with (ws-c3750X-24p-poe-s) with (ws-c3750-48p-10/100 poe) i mean even a switch is 10/100 and the other switch is 10/100/1000?
View 3 Replies
View Related
Apr 20, 2013
I have two Switches which i need to put in a same stack - WS-C3750E-48TD and WS-C3750G-48TS . Possible to do so and also which IOS to put in both the switches as WS-C3750G-48TS is having lower RAM and flash.Whether can i put following IOS in these switches and connect them in a stack as i have read that IOS -- 15.0.1. SE are compatible with both the switches.
a . c3750e-ipbasek9-mz.150-1.SE.bin in switch - WS-C3750E-48TD
b. c3750-ipbasek9-mz.150-1.SE.bin in switch -- WS-C3750G-48TS
View 8 Replies
View Related
Jan 27, 2013
I do have C3750G-12s switch which is not able to boot as of the expected. Every time when I break the stack and try to use console i got a weird output from my console output. we need the stack to be break and use those switch separtally .
[code]....
View 1 Replies
View Related
Jan 1, 2012
I have 8 switch stack consisting of six WS-C3550-48P and two WS-C3750G-16TD running software vesrion 12.2(25) SEB1. When I added new C3750v2-24PS (running image 12.2(50) SE5) in stack so I up-graded the image of existing 8 switches with latest veriosn 12.2(50) SE5. Once I have done with the upgrade then all ports of my stack switches went down after around five minuts. Is it image compatibility issue with existing switches or something else?
View 7 Replies
View Related
Nov 2, 2011
I have a situation. I am running two-switch 3750-stack and it crashed this morning. IOS version the switches is: "flash:c3750-ipservicesk9-mz.150-1.SE.bin"
SRPRSRGBYA#
Log Buffer (10000 bytes):
3:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan104, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan201, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan202, changed state to up
M-1-CRASHED: (SRPRSRGBYA-1)
Nov 3 13:18:13.336: %PLATFORM-1-CRASH(code)
View 3 Replies
View Related
Jan 23, 2013
We have a cisco stack with 5 ws-c3750-24p 12.2)55)SE3 c3750-ipbasek9-m switches. Can i add a switch to the stack that is the following model: ws-c3750g-48ts 12.2(25)see3 c3750-ipbase-m
View 3 Replies
View Related
Jun 11, 2013
I'm trying to stack 3750G & 3750X. As discussed in previous threads I am aware of that the version need to match.
Here the switch details:
Switch Ports Model SW Version SW Image
------ ----- -------------- ----------
* 1 24 WS-C3750G-24T 12.2(55)SE7 C3750-IPBASEK9-M
---------------------------------------------------------------------------------------------------------------
* 1 54 WS-C3750X-48 12.2(55)SE7 C3750E-IPBASEK9-M
I have changed the universal IOS on the 3750X to IP base..but they still wont come up as a stack. On the 3750X I don't see any log entry, on 3750G (major version mismatch).
View 4 Replies
View Related
Jan 30, 2012
WS-C3750G-24TS-S1U switch stack with high CPU utilization. 3 switches are stacked and using PBR on that. I am attaching the show cpu process as an attachment.The current template is "desktop routing" template.The selected template optimizes the resources in the switch to support this level of features for 8 routed interfaces and 1024 VLANs. [code]
View 0 Replies
View Related
Sep 11, 2012
I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not.also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Master switch has new boot path but unable to change in slaves.
View 1 Replies
View Related
Jul 16, 2012
Im trying to find an affordable Cisco switch with similar capabilities and features as the WS-C3560X-48T-S (L2/L3 routing as in IP Base, dual power supply, etc.).
View 2 Replies
View Related
Jul 31, 2012
I got a pair of new C3560X-24T-S switches with C3KX-NM-10G modules, and am trying to get a long distance 10G link up using 3rd party SFP-10G-ER SFPs (XGIGA with Cisco coded IDPROMs)I've enabled use of unsupported transcievers with the following commands:service unsupported-transceiver no errdisable detect cause gbic-invalidAfter that the switches accepts the SFPs but I get no light (sh int trans shows Tx -40), but if I insert a supported SFP first and then switches to my ER SFPs I get them to start transmitting, however I still don't LINK on the interface.I've tried with both 12.2(55)SE3 (that the switches came with) and 15.0(1)SE3 with same results.I know SFP-10G-ER SFPs are not supported on these switches, but are scheduled for the 15.0(2) release, but I was under the impression that they should already work using the above commands to enable the use of unsupported SFPs.So my question is basically: Is the new code in 15.0(2) really needed to make ER SFPs work, so I should just wait for that release, or are my 3rd party SFP simply broken/un-compatible with these switches?Also, could reprogramming them to look like SFP-10G-LR SFPs, which are supported, make any difference, or should it already have worked now with service unsupported-transceiver enabled if they were compatible?
View 5 Replies
View Related
Sep 9, 2012
Let me start with some infrastructure details ...
Cisco C2901 as our Main Router
Cisco UC520 as Communication Platform
Cisco C3560x as Core-Switch
VLAN 10 : Data
VLAN 100 : VOICE
Everything is working but i m not sure if the switchport config is right in that way.
As an example :
interface GigabitEthernet 0/6
switchport access vlan 10
switchport mode access
switchport voice vlan 100
spanning-tree portfast
When we connect an Cisco 7971g and an pc everything is working fine. But when i start wireshark on the pc behind the phone you see a lot of UDP Traffic source UC520 destination 239.10.16.8 or 239.10.16.16. At this point i m getting confused. So i start looking for the cisco phone config, VLAN ID on the phone is 100 (i think that is ok) but the PC-VLAN part is empty?
The main thing is, how can i stop this cisco-sccp traffic on the pc port (prtg shows me a average of 200 kbit/s) i think it is an config fault.
View 4 Replies
View Related
Feb 17, 2013
I have a Switch model WS-C3560X-24P with SW Version 12.2. (55) SE5 and SW Image C3560E-UNIVERSALK9-M. Now I get messages from 3 ports that:% ILPOWER-5-IEEE_DISCONNECT: Interface Gi0/12: PD removed. The strange thing is that there is nothing connected to these ports and they are like "notconnect»
An excerpt of the log looks like this:
1469058: Feb 18 09:08:33.945 CET: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi0/12: PD removed 1469060: Feb 18 09:08:49.279 CET: %ILPOWER-5-POWER_GRANTED: Interface Gi0/12: Power granted 1469061: Feb 18 09:08:50.310 CET: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi0/12: PD removed 1469063: Feb 18 09:09:02.280 CET: %ILPOWER-5-POWER_GRANTED: Interface Gi0/12: Power granted 1469064: Feb 18 09:09:03.413 CET: %ILPOWER-5-[Code]....
View 5 Replies
View Related
Aug 7, 2011
Is it possible to have a WS-C3750G-12S-S and a WS-C3750X-24T-L in the same stack, if so do they need to both be running the same software version/IOS.
View 6 Replies
View Related
Dec 12, 2011
I have recently installed 4 3560 (WS-C3560X-48T-S) Switches. At first the switch comes up, indicating all connected ports with a green LED. Whenever i unplug a cable and plug it back in, the status LED will stay off. The same thing happens when I push the mode button and cycle throgh the different modes, i lose certain LEDs.
I'm using 12.2(53)SE2, another user reported the same issues under 12.2(55)SE1 .
View 4 Replies
View Related
Jul 5, 2012
I would I upgrade this from a LAN base to ip services?
View 2 Replies
View Related
Jan 19, 2012
Does the Cisco WS-C3560X-24P-S switch supports ip flow export?
View 1 Replies
View Related
Sep 6, 2011
I have running a Stack with two C3750G-24TS-S1U with the IOS c3750-ipbasek9-mz.122-50.SE3.Now I want put a new C3750X-24T-S in the existing stack. I have read this is possible. I have running a other mixed stack with a C3750G-12S and an C3750E-48TD. Its running fine until I want to make an IOS update. The update was done with the CW LMS 3.1. After the automatic update and restart only the C3750E had an new IOS the C3750G doesn't have any IOS. Do I have the same problem with the mixed Stack C3750G and C3750X?Do I have to upgrade the IOS by copying the different IOS Versions ( c3750-ipbasek9-mz.122-50.SE3 / c3750e-ipbasek9-mz.122-50.SE3) to every switch ?
View 5 Replies
View Related
Apr 24, 2013
I have a WS-C3560X-24 and attached to that are some 9 acces switches, for some weeks now my 3560 reboots some time what couse that the other 9 switches are down for some minuts as well and i dont want this of course. the reboot happens at random times and some times one week not and then like yesterday afternoon it rebooted again.
when i check the Flash directory there is no crash file and when i look at the logging its clean and just shows the startup. it's not the powersuply it's redundend and more L3 switches are attached to this power source and they dont reboot.
L3_AIM#sh versionCisco IOS Software, C3560E Software (C3560E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)Technical Support: [URL] Copyright (c) 1986-2011 by Cisco Systems,
[Code]......
View 3 Replies
View Related
Oct 31, 2012
I was wondering if I can stack WS-C3750E-48TD with WS-C3750G-12S together to created a single logical switch.
View 3 Replies
View Related
Feb 27, 2013
Is there a stacking cable that is "bent"?Im using this cable:"CAB-STACK-50CM", "Cisco StackWise 50CM Stacking Cable".But it takes up to much room in the back of the switch, is there such a thing as "bent" stacking cable.
View 1 Replies
View Related
Oct 31, 2012
I have 3 switches in my 3750 X stack. I am getting the following error in the logs: %PLATFORM_STACKPOWER-4-PRIO_CONFLICT: Switch 1's power stack has conflicting power priorities. Not sure what I should do next. Below is my Stack-power configuration:
Power stack name: Powerstack-1 Stack mode: Power sharing Stack topology: Ring Switch 1: Power budget: 735 Low port priority value: 20 High port priority value: 10 Switch priority value: 2 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: c464.1308.7900 Neighbor on port 2: e8b7.4827.e680
Switch 3: Power budget: 729 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd9.9f00 Neighbor on port 2: 2894.0fd8.e200
Switch 2: Power budget: 690 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd8.e200 Neighbor on port 2: c464.1308.7900
Each switch has its own 715W power supply in it and all check out OK.
View 3 Replies
View Related
Sep 24, 2012
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
View 8 Replies
View Related
Sep 10, 2012
I would like to know if Catalyst WS-C3750G-48TS-E recognizes and understand Cisco VSS ( Virtual Switching System) . Is there a List available which tells us which Old Catalyst Switches or current switches understand Cisco VSS?
View 3 Replies
View Related
Sep 11, 2012
I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not. Also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Any other way to update it. Master switch has new boot path but unable to change in slaves.
View 2 Replies
View Related
Dec 7, 2011
We recently connected a RPS 2300 to our switch WS-C3750G-48PS-E with IOS c3750-ipservicesk9-mz.122-53.SE2.bin.However i do not see any RPS details in the"show env" output.I believe i should get the RPS Name and its Serial and the port number in the output, but i am not finding it in the output. I did reload the switch but still couldnot get this udpated.
View 3 Replies
View Related
May 29, 2012
I have a process whick take all the CPU on two differents Stack of WS-C3750G in version 12.2.53(SE2):
XFRPALSN02R#sh proc cpu sorted CPU utilization for five seconds: 97%/3%; one minute: 95%; five minutes: 95% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 307 5450059 4167397 1307 86.74% 83.63% 83.35% 0 hulc nrgyz PD di XFRPALSN02R#sh proc cpu sorted CPU utilization for five seconds: 96%/3%; one minute: 96%; five minutes: 96% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 307 7779608 5947379 1308 86.26% 85.75% 85.30% 0 hulc nrgyz PD di
View 2 Replies
View Related
Feb 17, 2012
I have the following switch:
#show version
Cisco IOS Software, C3750 Software (C3750-IPSERVICES-M), Version 12.2(52)SE, RELEASE SOFTWARE (fc3)
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Image text-base: 0x01000000, data-base: 0x02C00000
ROM: Bootstrap program is C3750 boot loader
BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(44)SE5, RELEASE SOFTWARE (fc1)
[code]...
I have downloaded c3750-ipservicesk9-mz.150-1.SE2.bin and I want to upgrade iOS to this image.
I have a few questions related to this:
1. Is my switch model compatible with this iOS version?
2. Do you recommend the upgrade? Does it bring some notable features?
3. Can I upgrade for free or do I need to buy some license?
4. I also want to upgrade/add the crypto image, can I add crypto for free or some license is required?
5. I have remote access to my switch via the console cable which plugged into machine1. But machine1 is connected to network via the same switch. I am accessing machine1 via SSH, and then the switch via console cable (minicom on CentOS). Is there an upgrade procedure for this kind of situation that also has some fall back (like reboot in X minutes and load the previous image) if the upgrade goes wrong?
View 6 Replies
View Related
Apr 16, 2013
We are facing since one month in our two Cisco WS-C3750G-12S on many interfaces input errors when data transer or ping (ICMP) increase input erros. Not only port 1 but many interface has same issue, i have change new IOS but still same issue, once i have erase startup config but same issue we are facing and finaly i have replace same new switch with the same IOS it's working fine.(c3750-ipservicesk9-mz.122-55.SE4.bin) [code]
View 11 Replies
View Related
Aug 29, 2012
I currently have a C3750G connected to a C3560G with default auto-negotiation settings. Ports are up and connected a-100 and a-full. I am trying to change the ports speed to 1G, and have tried all possible combinations of "speed 1000" and "duplex full" setting on both ends to no avail. What should port settings be for 1G speed between the two switches?
Here are the current port settings:C3750G:
interface GigabitEthernet1/0/1
switchport trunk encapsulation dot1q
[Code].....
View 8 Replies
View Related
Apr 22, 2012
i have a Layer3 Switch Cisco WS-c3750G -24T , initially i have a IOS version c3750-Ipbase , recentely i have upgraded my IOS to c3750-Ipservices-M to enable to PBR for my network , i have created all the acl and tried to give the route-map with PBR , the command was initiallying but i am not able to see the applied route-map in my policy route , i have gone through the blog and enabled SDM prefer routing , but no luck .
View 1 Replies
View Related
Feb 9, 2012
I have Catalyst C3750G switch
with configured route to subnet 192.168.201.0/24
ip routing
ip route 192.168.201.0 255.255.255.0 192.168.160.13
192.168.160.13 is accessible
[Code].....
View 5 Replies
View Related