Cisco Switching/Routing :: Can WS-C3750E-48TD And WS-C3750G-48TS Be In Same Stack
Apr 20, 2013
I have two Switches which i need to put in a same stack - WS-C3750E-48TD and WS-C3750G-48TS . Possible to do so and also which IOS to put in both the switches as WS-C3750G-48TS is having lower RAM and flash.Whether can i put following IOS in these switches and connect them in a stack as i have read that IOS -- 15.0.1. SE are compatible with both the switches.
a . c3750e-ipbasek9-mz.150-1.SE.bin in switch - WS-C3750E-48TD
b. c3750-ipbasek9-mz.150-1.SE.bin in switch -- WS-C3750G-48TS
View 8 Replies
ADVERTISEMENT
Feb 13, 2012
Is that possible add WS-C3750-48TS-E to ws-c3750e-48td stack?
View 4 Replies
View Related
Oct 31, 2012
I was wondering if I can stack WS-C3750E-48TD with WS-C3750G-12S together to created a single logical switch.
View 3 Replies
View Related
Dec 20, 2012
7x stack WS-C3750E-48TD-E orignal code 12.2.35...i wanted to get it to 15.0.1 so as a test i disconnected top switch (not the master ) and installed via archive download-sw /allow upgrade 15.0.1.tar. and it worked away fine...
so i moved onto the stack, issued the same command, image loaded rebooted and stack hung..Consoled in and switch was unable to boot..looping on trying to load flash. [code]
View 8 Replies
View Related
Jan 23, 2013
We have a cisco stack with 5 ws-c3750-24p 12.2)55)SE3 c3750-ipbasek9-m switches. Can i add a switch to the stack that is the following model: ws-c3750g-48ts 12.2(25)see3 c3750-ipbase-m
View 3 Replies
View Related
May 2, 2012
My question is about WS-C3750E-48TD-S and WS-C3750E-24TD-S Switches
What are the limitations of the mapping of VLANs on this device? Is it limited by number or by interface? Does the configuration of an interface has spread all interfaces ?
View 1 Replies
View Related
Feb 21, 2013
I have a problem with Total Output Drops, it's increase and decreases on WS-C3750E-48TD-E.
SWCIACTCT05#sh int gi1/0/47 | i Total output drops:
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 6487344
SWCIACTCT05#sh int gi1/0/47 | i Total output drops:
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 6487344
SWCIACTCT05#sh int gi1/0/47 | i Total output drops:
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 6487344
[code]....
I checked and found two registered bug id: CSCtq86186 / CSCso81660.I would like to know what is the best IOS version to update my switch, IOS 15.0.2 SE2 or 12.2.58 SE2, by the way, my environment is very critical (data center) and the version 15.0.2 SE2 is very recent, but its stable ?In both versions the problem are fixed?
View 3 Replies
View Related
Aug 12, 2012
Situation: Currently WS-C3750G-48TS-(S or E) switches are on stack. Now these units will soon EOL on Jan. 30, 2013 and Cisco recommends that
WS-C3750X-48T-S or WS-C3750X-48T-E will be used.
The question is: Will the new SKU works together in a stack with the old ones? Will there be no changes on the type of stacking cable to be used?
View 7 Replies
View Related
Sep 10, 2012
I would like to know if Catalyst WS-C3750G-48TS-E recognizes and understand Cisco VSS ( Virtual Switching System) . Is there a List available which tells us which Old Catalyst Switches or current switches understand Cisco VSS?
View 3 Replies
View Related
Dec 16, 2012
I have a Cisco WS-C2960S-48TD-L with 12.2(55)SE2.This is a standalone switch, not in stack, and with no order it reboots itself looking for a new master election. On logging i have nothing, but connected with console cable i see the following after 2 minutes of not showing anything:
Waiting for Stack Master Election...
...
The switch reboots and:
...
*Mar 1 00:00:12.289: Read env variable - LICENSE_BOOT_LEVEL =
[URL]
After searching online i have no seeing nothing about disable the feature of the stack so i configure the priority for the "switch 1" to 15 and configure it the switches 2, 3 and 4 to no provision, although this switches don´t exist:
SW_ACCESS(config)#switch 1 priority 15
Changing the Switch Priority of Switch Number 1 to 15
Do you want to continue?[confirm]
New Priority has been set successfully
[URL]
With this new configuration the switch has rebooted again.Why on a standalone switch the stack is rebooting my system?Is it any feature to disable the stack?
View 8 Replies
View Related
Jan 11, 2012
Currently there are three stacked WS-C3750G-24TS-1U on data centre. I am going to buy a WS-C3560X-48T-L to use 10GbE module. Is it possible stack this switch "WS-C3560X-48T-L" to current switches "WS-C3750G-24TS-1U" ?
View 1 Replies
View Related
Feb 3, 2012
can i stack cisco (ws-c3750G-12s) with (ws-c3750X-24p-poe-s) with (ws-c3750-48p-10/100 poe) i mean even a switch is 10/100 and the other switch is 10/100/1000?
View 3 Replies
View Related
Jan 27, 2013
I do have C3750G-12s switch which is not able to boot as of the expected. Every time when I break the stack and try to use console i got a weird output from my console output. we need the stack to be break and use those switch separtally .
[code]....
View 1 Replies
View Related
Jan 1, 2012
I have 8 switch stack consisting of six WS-C3550-48P and two WS-C3750G-16TD running software vesrion 12.2(25) SEB1. When I added new C3750v2-24PS (running image 12.2(50) SE5) in stack so I up-graded the image of existing 8 switches with latest veriosn 12.2(50) SE5. Once I have done with the upgrade then all ports of my stack switches went down after around five minuts. Is it image compatibility issue with existing switches or something else?
View 7 Replies
View Related
Nov 2, 2011
I have a situation. I am running two-switch 3750-stack and it crashed this morning. IOS version the switches is: "flash:c3750-ipservicesk9-mz.150-1.SE.bin"
SRPRSRGBYA#
Log Buffer (10000 bytes):
3:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan104, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan201, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan202, changed state to up
M-1-CRASHED: (SRPRSRGBYA-1)
Nov 3 13:18:13.336: %PLATFORM-1-CRASH(code)
View 3 Replies
View Related
Jun 11, 2013
I'm trying to stack 3750G & 3750X. As discussed in previous threads I am aware of that the version need to match.
Here the switch details:
Switch Ports Model SW Version SW Image
------ ----- -------------- ----------
* 1 24 WS-C3750G-24T 12.2(55)SE7 C3750-IPBASEK9-M
---------------------------------------------------------------------------------------------------------------
* 1 54 WS-C3750X-48 12.2(55)SE7 C3750E-IPBASEK9-M
I have changed the universal IOS on the 3750X to IP base..but they still wont come up as a stack. On the 3750X I don't see any log entry, on 3750G (major version mismatch).
View 4 Replies
View Related
Jan 30, 2012
WS-C3750G-24TS-S1U switch stack with high CPU utilization. 3 switches are stacked and using PBR on that. I am attaching the show cpu process as an attachment.The current template is "desktop routing" template.The selected template optimizes the resources in the switch to support this level of features for 8 routed interfaces and 1024 VLANs. [code]
View 0 Replies
View Related
Sep 11, 2012
I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not.also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Master switch has new boot path but unable to change in slaves.
View 1 Replies
View Related
May 3, 2013
Any replacement fan for the WS-C3750G-48TS-S switch that runs quieter than the one originally built into this router? I've searched a number of web sites and found plenty of replacement fans available but none of them show noise level specifications.
particular manufacturer/model combination that works in this router that will drop the noise level down while maintaining air flow. This switch is in a short network rack in an small office that also includes people. The current noise level isn't defining like some servers, but is loud enough to be distracting.
View 6 Replies
View Related
Aug 7, 2011
Is it possible to have a WS-C3750G-12S-S and a WS-C3750X-24T-L in the same stack, if so do they need to both be running the same software version/IOS.
View 6 Replies
View Related
May 31, 2012
I have a C3750E-24TD-S on which I just loaded new firmware. When I boot up I see this:Loading "c3750e-universalk9-mz.150-1.SE2.bin"...c3750e-universalk9-mz.150-1.SE2.bin: no such device
Error loading "c3750e-universalk9-mz.150-1.SE2.bin"
Interrupt within 5 seconds to abort boot process. Loading "flash:/c3750e-universalk9-mz.150-1.SE2.bin".
View 13 Replies
View Related
Jun 1, 2012
I want to connect WS-C2960S-48TD-L switch to WS-X6708-10G-3CXL module in Cisco WS-C6503-E switch. WS-X6708-10G-3CXL is C6K 8 port 10 Gigabit Ethernet module with DFC3CXL which requires X2 module. on the otherhand, WS-C2960S-48TD-L requires SFP+. Now is it possible to interconnect these two switch interfaces if I use LIU in between. or does WS-X6708-10G-3CXL module supports CVR-X2-SFP+ to use SFP+ transceivers.
View 2 Replies
View Related
Nov 29, 2011
As above, I got a problem with C3750e, ios c3750e-universalk9-mz.122-58.SE1.bin, when send AF41 traffic passing through it. My topolygy is as following
WAN link <----------> G0/0/2.100 - ASR1002 - G0/0/5 <---------> G1/0/1 - C3750e - G1/0/3 <--------> G0/0/1 - ASR1004
On this C3750e, I turned on mls qos, trust dscp on both G1/0/1 and G1/0/3 and no else is configured. ASR1002 G0/0/2.100, i applied the CB shaping fror AF41 traffic.
C3750e#sh mls qos
QoS is enabled
QoS ip packet dscp rewrite is enabled
C3750e#sh mls qos int g1/0/3
GigabitEthernet1/0/3
trust state: trust dscp
[code]....
Then, from ASR1004, i send ICMP traffic with TOS set to AF41 (136) and i found out that
1. The traffic is dropped on c3750e
sh mls qos int g1/0/3 statistics
GigabitEthernet1/0/3 (All statistics are in packets)
30 - 34 : 63 63 48 86 1534
2. The traffic never get hit into AF41 class in ASR1002 ? Why C3750e dropped this AF41 traffic? and what can I do to fix it?
View 1 Replies
View Related
Sep 6, 2011
I have running a Stack with two C3750G-24TS-S1U with the IOS c3750-ipbasek9-mz.122-50.SE3.Now I want put a new C3750X-24T-S in the existing stack. I have read this is possible. I have running a other mixed stack with a C3750G-12S and an C3750E-48TD. Its running fine until I want to make an IOS update. The update was done with the CW LMS 3.1. After the automatic update and restart only the C3750E had an new IOS the C3750G doesn't have any IOS. Do I have the same problem with the mixed Stack C3750G and C3750X?Do I have to upgrade the IOS by copying the different IOS Versions ( c3750-ipbasek9-mz.122-50.SE3 / c3750e-ipbasek9-mz.122-50.SE3) to every switch ?
View 5 Replies
View Related
Mar 9, 2012
Recently on two switches, both being same cisco WS-C3750E-24PD, running with same IOS c3750e-universalk9-mz.122-58.SE2.bin got noticed that the license state of one switch is showing incorrectly as shown below [code] I will not be able to execute any changes/modifications on switch as of now.
View 9 Replies
View Related
Jun 13, 2012
Can I upgrade my 3750 48TS-S to the EMI software or does it need to be a 48TS-E?
View 2 Replies
View Related
Mar 7, 2012
This switch randomly reboots throughout the day. I checked the stacks info and reported it was using crashinfo_12 (report below). I have access to the switch throughout the day if more config info needs to exported.
Cisco IOS Software, C3560 Software (C3560-IPBASEK9-M), Version 12.2(50)SE1, RELEASE SOFTWARE (fc2)
Copyright (c) 1986-2009 by Cisco Systems, Inc.
[Code].....
View 1 Replies
View Related
Jun 12, 2012
My old switch software version is c3750-ipbase-mz.122-35.SE5 and model number is WS-C3750-48TS-S and my new switch Software version is c3750-ipservicesk9-mz.122-50.SE5.bin and model number is WS-C3750V2 . I want a compatible (prefer same) version of IOS which works on both the switches as both the switch will be in a stack..
View 4 Replies
View Related
Feb 27, 2013
Is there a stacking cable that is "bent"?Im using this cable:"CAB-STACK-50CM", "Cisco StackWise 50CM Stacking Cable".But it takes up to much room in the back of the switch, is there such a thing as "bent" stacking cable.
View 1 Replies
View Related
Oct 31, 2012
I have 3 switches in my 3750 X stack. I am getting the following error in the logs: %PLATFORM_STACKPOWER-4-PRIO_CONFLICT: Switch 1's power stack has conflicting power priorities. Not sure what I should do next. Below is my Stack-power configuration:
Power stack name: Powerstack-1 Stack mode: Power sharing Stack topology: Ring Switch 1: Power budget: 735 Low port priority value: 20 High port priority value: 10 Switch priority value: 2 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: c464.1308.7900 Neighbor on port 2: e8b7.4827.e680
Switch 3: Power budget: 729 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd9.9f00 Neighbor on port 2: 2894.0fd8.e200
Switch 2: Power budget: 690 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd8.e200 Neighbor on port 2: c464.1308.7900
Each switch has its own 715W power supply in it and all check out OK.
View 3 Replies
View Related
Sep 24, 2012
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
View 8 Replies
View Related
Feb 28, 2013
I've got two two 3560s switchs, (WS-C3560G-48TS-S) that I'm trying to connect to each other using the GB ports over Fibre. We purchased the following GBICs, SFP 1000SX Transceiver and when we put them in the port it shows (err-disabled). Below is some information I pulled from one of the ports, but doesn't matter what port I use they all say the same thing.
ProdSwitchSW1#show run int g0/51
Building configuration...
Current configuration : 37 bytes
!
interface GigabitEthernet0/51
end
[code]....
Configuration register is 0xF
View 3 Replies
View Related
Oct 4, 2012
May I know why my 2960S-48TS-L takes 10 minutes to boot and start, some just take 1 minute, but one of them take up to 10 minutes, but after that it works fine, why?
View 2 Replies
View Related